{"id":285464,"date":"2025-11-20T16:41:45","date_gmt":"2025-11-20T07:41:45","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/mettler-toredo-0782-high-capacity-canister-load-cell\/"},"modified":"2025-11-21T09:12:29","modified_gmt":"2025-11-21T00:12:29","slug":"mettler-toredo-0782-high-capacity-canister-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/mettler-toredo-0782-high-capacity-canister-load-cell\/","title":{"rendered":"METTLER TOREDO \/ 0782 \/ High Capacity Canister Load Cell"},"content":{"rendered":"<h4>0782 High Capacity Load Cell<\/h4>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-285462\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_2-2.png\" alt=\"\" width=\"1216\" height=\"399\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_2-2.png 1216w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_2-2-800x263.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_2-2-768x252.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_2-2-600x197.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_2-2-64x21.png 64w\" sizes=\"(max-width: 1216px) 100vw, 1216px\" \/><\/p>\n<p><strong>Vehicle Weighing<\/strong><br \/>\nUse the 0782 load cell in new truck, rail road track and other heavy capacity weigh bridge applications or as are place ment for cells in an old weigh-bridge to enhance its performance. The 0782 is ideally suited to this application.<br \/>\n<strong><br \/>\nTank Weighing<\/strong><br \/>\nThe capacity range from 20t to 300t allows the weighing of big tanks and silos with ease. The stainless steel design (20t\u2013200t), hermetic sealing and IP68 protection provides the best reliability in tank weighing appli cations.<br \/>\n<strong><br \/>\nGAGEMOUNT Module<\/strong><br \/>\nThe optional METTLER TOLEDO GAGEMOUNT (20t\u2013100t) weigh module adds suspension, checking and anti-tiping to your 0782 load cell and includes top and bottom moun ting plates to simplify installation. Available in nickel plated mild steel or stain-<br \/>\nless steel.<\/p>\n<p>&nbsp;<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td colspan=\"2\"><strong>Parameter<\/strong><\/td>\n<td><strong>unit of measure<\/strong><\/td>\n<td colspan=\"6\"><strong>Specification<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Model No.<\/td>\n<td><\/td>\n<td colspan=\"6\">0782<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated Capacity (R.C.)<\/td>\n<td>t (klb, nominal)<\/td>\n<td>20 (44)<\/td>\n<td>30 (66)<\/td>\n<td>50 (110)<\/td>\n<td>100 (220)<\/td>\n<td>200 (441)<\/td>\n<td>300 (661)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated Output<\/td>\n<td>mV\/V @R.C.<\/td>\n<td colspan=\"6\">2 \u00b1 0.1%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Zero load Output<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"6\">\u2264 1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Combined Error 1)2)<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"4\">\u2264 0.018<\/td>\n<td>\u2264 0.05<\/td>\n<td>\u2264 0.06<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Repeatability Error<\/td>\n<td>%A.L. 3)<\/td>\n<td colspan=\"4\">\u2264 0.01<\/td>\n<td colspan=\"2\">\u2264 0.02<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Creep, 30 minute<\/td>\n<td>%A.L.<\/td>\n<td colspan=\"4\">\u2264 0.0167<\/td>\n<td>\u2264 0.03<\/td>\n<td>\u2264 0.04<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Min. Dead Load Output Return (DR), 30 min<\/td>\n<td>%A.L.<\/td>\n<td colspan=\"4\">\u2264 0.0167<\/td>\n<td>\u2264 0.03<\/td>\n<td>\u2264 0.04<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Temperature Effect on<\/td>\n<td>Min. Dead load Output<\/td>\n<td>%R.C.\/\u00b0C (..\/\u00b0F)<\/td>\n<td colspan=\"6\">\u2264 0.002 (0.001)<\/td>\n<\/tr>\n<tr>\n<td>Sensitivity 2)<\/td>\n<td>%A.L.\/\u00b0C (..\/\u00b0F)<\/td>\n<td colspan=\"4\">\u2264 0.0009 (0.0005)<\/td>\n<td colspan=\"2\">\u2264 0.002 (0.001)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><u>Compensated <\/u> Temperature Range <u> Operating <\/u><br \/>\nSafe Storage<\/td>\n<td>\u00b0C (\u00b0F)<\/td>\n<td colspan=\"6\"><u> <\/u><u>-10 ~ +40 (+14 ~ +104)<\/u><u> <\/u><br \/>\n<u> <\/u><u>-40 ~ +65 (-40 ~ +150)<\/u><u> <\/u><br \/>\n-40 ~ +80 (-40 ~ +176)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"9\">OIML \/ European Approval 4)<\/td>\n<td>OIML Cert. No.<\/td>\n<td><\/td>\n<td colspan=\"4\">R60\/2000-NL-01.04<\/td>\n<td colspan=\"2\" rowspan=\"9\">\u2013<\/td>\n<\/tr>\n<tr>\n<td>European Cert. No.<\/td>\n<td><\/td>\n<td colspan=\"4\">NMi TC5844<\/td>\n<\/tr>\n<tr>\n<td>Class<\/td>\n<td><\/td>\n<td colspan=\"4\">C3<\/td>\n<\/tr>\n<tr>\n<td>nmax<\/td>\n<td><\/td>\n<td colspan=\"4\">3000<\/td>\n<\/tr>\n<tr>\n<td>Y<\/td>\n<td><\/td>\n<td colspan=\"4\">6666<\/td>\n<\/tr>\n<tr>\n<td>PLC<\/td>\n<td><\/td>\n<td colspan=\"4\">0.7<\/td>\n<\/tr>\n<tr>\n<td>Humidity Symbol<\/td>\n<td><\/td>\n<td colspan=\"4\">none<\/td>\n<\/tr>\n<tr>\n<td>Min. dead load<\/td>\n<td>kg (lb)<\/td>\n<td colspan=\"4\">0 (0)<\/td>\n<\/tr>\n<tr>\n<td>Z<\/td>\n<td><\/td>\n<td colspan=\"4\">3000<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">NTEP Approval 4)<\/td>\n<td>Number<\/td>\n<td><\/td>\n<td colspan=\"4\">01-004<\/td>\n<td colspan=\"2\" rowspan=\"5\">\u2013<\/td>\n<\/tr>\n<tr>\n<td>Class<\/td>\n<td><\/td>\n<td colspan=\"4\">III L M<\/td>\n<\/tr>\n<tr>\n<td>nmax<\/td>\n<td><\/td>\n<td colspan=\"4\">10000<\/td>\n<\/tr>\n<tr>\n<td>Vmin<\/td>\n<td>kg (lb)<\/td>\n<td>1.4 (3.0)<\/td>\n<td>2.1 (4.5)<\/td>\n<td>3.5 (7.5)<\/td>\n<td>7.0 (15.0)<\/td>\n<\/tr>\n<tr>\n<td>Min. dead load<\/td>\n<td>kg (lb)<\/td>\n<td colspan=\"4\">50 (100)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">ATEX Approval 4)<\/td>\n<td><u><\/u><u>Number, cat.<\/u> <u>2<\/u><u> <\/u><br \/>\nRating<\/td>\n<td rowspan=\"2\"><\/td>\n<td colspan=\"6\"><u> <\/u><u>KEMA<\/u> <u>02ATEX1249<\/u> <u>X<\/u><u> <\/u><br \/>\nII 2 G Ex ib IIC T4 \u2026 T6<br \/>\nII 2 D Ex ibD 21 IP68 T60\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Entity Parameters<\/td>\n<td colspan=\"6\">Ui=25V, Ii=600mA, Pi=0.57 &#8211; 1.25W, Ci=2.6 &#8211; 6nF, Li=10.25 &#8211; 30\u00b5H<\/td>\n<\/tr>\n<tr>\n<td><u><\/u><u>Number, cat.<\/u> <u>3<\/u><u> <\/u><\/p>\n<p>Rating<\/td>\n<td rowspan=\"2\"><\/td>\n<td colspan=\"6\"><u> <\/u><u>KEMA 06ATEX0122 <\/u> II 3 G Ex nL IIC T6<br \/>\nII 3 G Ex nA II T6<br \/>\nII 3 D Ex tD A22 IP 68 T60\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Entity Parameters<\/td>\n<td colspan=\"6\">Ui = 25V, Ci 2.6 &#8211; 6nF, Li 10.25 &#8211; 30 \u00b5H<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Factory Mutual Approval 4)<\/td>\n<td rowspan=\"2\"><u><\/u><u>Number,<\/u> <u>USA<\/u><u> <\/u><br \/>\nRating<br \/>\n<u> <\/u><br \/>\nEntity Parameters<\/td>\n<td rowspan=\"3\"><\/td>\n<td colspan=\"6\"><u> <\/u><u>3013511<\/u><u> <\/u><br \/>\nIS\/I,II,III\/1\/ABCDEFG\/T4<br \/>\n<u> <\/u><u>NI\/I,II,III\/2\/ABCDFG\/T4<\/u><u> <\/u> Vmax=20V, Imax=600mA, Pi=1.25W<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Ci=4nF, Li=17.7\u00b5H<\/td>\n<td>Ci=6nF, Li=26.5\u00b5H<\/td>\n<\/tr>\n<tr>\n<td>System Drawing No, USA<\/td>\n<td colspan=\"6\">142730<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Excitation Voltage <u> Recommended <\/u>Max.<\/td>\n<td>V AC\/DC<\/td>\n<td colspan=\"6\"><u> <\/u><u>5 ~ 15<\/u><u> <\/u><br \/>\n20<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">Terminal Resistance <u> Excitation <\/u>Output<\/td>\n<td rowspan=\"2\">\u03a9<\/td>\n<td colspan=\"4\">1160 \u00b1 10<\/td>\n<td colspan=\"2\">1160 \u00b1 15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">1000 \u00b1 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Insulation Resistance @50VDC<\/td>\n<td>M\u03a9<\/td>\n<td colspan=\"6\">&gt; 5000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Breakdown Voltage<\/td>\n<td>V AC<\/td>\n<td colspan=\"6\">&gt;500<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Material<\/td>\n<td>Spring Element<\/td>\n<td><\/td>\n<td colspan=\"5\">stainless steel<\/td>\n<td>4340<\/td>\n<\/tr>\n<tr>\n<td>Enclosure<\/td>\n<td><\/td>\n<td colspan=\"6\">stainless steel<\/td>\n<\/tr>\n<tr>\n<td>Cable entry fitting<\/td>\n<td><\/td>\n<td colspan=\"6\">stainless steel<\/td>\n<\/tr>\n<tr>\n<td>Cable<\/td>\n<td><\/td>\n<td colspan=\"6\">PVC<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Protection<\/td>\n<td>Type<\/td>\n<td><\/td>\n<td colspan=\"6\">welded<\/td>\n<\/tr>\n<tr>\n<td>IP Rating<\/td>\n<td><\/td>\n<td colspan=\"6\">IP 68<\/td>\n<\/tr>\n<tr>\n<td>NEMA Rating<\/td>\n<td><\/td>\n<td colspan=\"6\">NEMA 6\/6P<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Load Limit <u> Safe <\/u>Ultimate<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"6\"><u> <\/u><u>125<\/u><u> <\/u><br \/>\n300<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Safe Dynamic Load<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"6\">70<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Fatigue Life<\/td>\n<td>cycles @R.C.<\/td>\n<td colspan=\"6\">&gt;1,000,000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Direction of Loading<\/td>\n<td><\/td>\n<td colspan=\"6\">compression<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Restoring Force 5)<\/td>\n<td>%A.L.\/mm (..\/in) 3)<\/td>\n<td colspan=\"2\">0.8 (19)<\/td>\n<td colspan=\"2\">2 (52)<\/td>\n<td>1.6 (40)<\/td>\n<td>2.5 (63)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Max Horizontal Travel 6)<\/td>\n<td>\u00b1 mm (in)<\/td>\n<td colspan=\"3\">4 (0.16)<\/td>\n<td>5 (0.20)<\/td>\n<td colspan=\"2\">6 (0.24)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Deflection @ R.C., nominal<\/td>\n<td>mm (in)<\/td>\n<td colspan=\"4\">0.25 (0.010)<\/td>\n<td>0.32 (0.013)<\/td>\n<td>0.42 (0.017)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Weight, nominal<\/td>\n<td>kg (lb)<\/td>\n<td>2.8 (6.2)<\/td>\n<td>3 (6.6)<\/td>\n<td>3.3 (7.3)<\/td>\n<td>4.5 (9.9)<\/td>\n<td>12.5 (27.6)<\/td>\n<td>21.7 (48)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Cable<\/td>\n<td>Length<\/td>\n<td>m (ft)<\/td>\n<td colspan=\"4\">13 (42.5)<\/td>\n<td>20 (66)<\/td>\n<td>30 (98)<\/td>\n<\/tr>\n<tr>\n<td>Diameter<\/td>\n<td>mm (in)<\/td>\n<td colspan=\"6\">5.8 (0.23)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Barometric Pressure Effect on Zero Load Output<\/td>\n<td>kg\/kPa (lb\/in.Hg)<\/td>\n<td>3 (6.6)<\/td>\n<td>4.5 (9.9)<\/td>\n<td>7.5 (16.5)<\/td>\n<td>15 (33)<\/td>\n<td>30 (66)<\/td>\n<td>45 (99)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>1)\u00a0Error due to the combined effect of non-linearity and hysteresis<br \/>\n2)\u00a0Typical values only. The sum of errors due to Combined Error and Temperature Effect on Sensitivity comply with the requirements of OIML R60 and NIST HB44.<br \/>\n3)\u00a0A.L. = Applied Load<br \/>\n4)\u00a0See certificate for complete information.<br \/>\n5)\u00a0% of Applied Load (A.L.) per mm (in) displacement of the top button relative to the bottom button.<br \/>\n6)\u00a0Maximum horizontal displacement of the top button relative to the bottom button.<br \/>\n7)\u00a0In process, consult factory.<\/p>\n<p><strong>0782 Load Cell Dimensional Drawings mm [inch]<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-285455\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_3.png\" alt=\"\" width=\"1158\" height=\"631\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_3.png 1158w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_3-734x400.png 734w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_3-768x418.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_3-600x327.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_3-64x35.png 64w\" sizes=\"(max-width: 1158px) 100vw, 1158px\" \/><\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td rowspan=\"2\"><strong>Capacity<\/strong><\/td>\n<td colspan=\"10\"><strong>Dimensions<\/strong> <strong>and<\/strong> <strong>Locations<\/strong><\/td>\n<\/tr>\n<tr>\n<td>D<\/td>\n<td>D1<\/td>\n<td>H<\/td>\n<td>H1<\/td>\n<td>H2<\/td>\n<td>H3<\/td>\n<td>L<\/td>\n<td>L1<\/td>\n<td>R<\/td>\n<td>W<\/td>\n<\/tr>\n<tr>\n<td>20 \u201330 t [33\u201366 kIb]<\/td>\n<td>76 [2.99]<\/td>\n<td>37.8 [1.49]<\/td>\n<td>150 [5.91]<\/td>\n<td>112 [4.41]<\/td>\n<td>19 [0.75]<\/td>\n<td>75 [2.95]<\/td>\n<td>33.5 [1.40]<\/td>\n<td>50 [1.97]<\/td>\n<td>160 [6.30]<\/td>\n<td>96 [3.78]<\/td>\n<\/tr>\n<tr>\n<td>50 t [110 kIb]<\/td>\n<td>76 [2.99]<\/td>\n<td>37.8 [1.49]<\/td>\n<td>150 [5.91]<\/td>\n<td>112 [4.41]<\/td>\n<td>19 [0.75]<\/td>\n<td>75 [2.95]<\/td>\n<td>35.5 [1.40]<\/td>\n<td>50 [1.97]<\/td>\n<td>305 [12.0]<\/td>\n<td>96 [3.78]<\/td>\n<\/tr>\n<tr>\n<td>100 t [220 kIb]<\/td>\n<td>102 [4.02]<\/td>\n<td>53.8 [2.12]<\/td>\n<td>150 [5.91]<\/td>\n<td>112 [4.41]<\/td>\n<td>19 [0.75]<\/td>\n<td>75 [2.95]<\/td>\n<td>50.6 [1.99]<\/td>\n<td>64 [2.52]<\/td>\n<td>305 [12.0]<\/td>\n<td>123 [4.84]<\/td>\n<\/tr>\n<tr>\n<td>200 t [440 kIb]<\/td>\n<td>158 [6.22]<\/td>\n<td>80 [3.15]<\/td>\n<td>195 [7.68]<\/td>\n<td>145 [5.71]<\/td>\n<td>25 [0.98]<\/td>\n<td>93 [3.66]<\/td>\n<td>75.25 [2.96]<\/td>\n<td>93 [3.66]<\/td>\n<td>400 [5.75]<\/td>\n<td>180 [7.09]<\/td>\n<\/tr>\n<tr>\n<td>300 t [660 kIb]<\/td>\n<td>192 [7.56]<\/td>\n<td>106 [4.17]<\/td>\n<td>250 [9.84]<\/td>\n<td>192 [7.56]<\/td>\n<td>29 [1.14]<\/td>\n<td>128 [5.04]<\/td>\n<td>99.20 [3.91]<\/td>\n<td>110 [4.33]<\/td>\n<td>900 [35.4]<\/td>\n<td>213 [8.39]<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>0782 Load Cell Receivers mm [inch] 20t\u201350t<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-285457\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_4.png\" alt=\"\" width=\"790\" height=\"706\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_4.png 790w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_4-448x400.png 448w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_4-768x686.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_4-600x536.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_4-64x57.png 64w\" sizes=\"(max-width: 790px) 100vw, 790px\" \/><\/p>\n<p><strong>0782 Load Cell Receivers mm [inch] 100t<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-285459\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_5.png\" alt=\"\" width=\"736\" height=\"558\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_5.png 736w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_5-528x400.png 528w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_5-600x455.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_5-64x49.png 64w\" sizes=\"(max-width: 736px) 100vw, 736px\" \/><\/p>\n<p><strong>0782 Load Cell Order Information<\/strong><\/p>\n<table width=\"100%\">\n<thead>\n<tr>\n<th>Description<\/th>\n<th>Item No.<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Load Cell 0782 \u2013 20t<\/td>\n<td>71201708<\/td>\n<\/tr>\n<tr>\n<td>Load Cell 0782 \u2013 30t<\/td>\n<td>71201709<\/td>\n<\/tr>\n<tr>\n<td>Load Cell 0782 \u2013 50t<\/td>\n<td>71201710<\/td>\n<\/tr>\n<tr>\n<td>Load Cell 0782 \u2013 100t<\/td>\n<td>71201711<\/td>\n<\/tr>\n<tr>\n<td>Load Cell 0782 \u2013 200t<\/td>\n<td>71210093<\/td>\n<\/tr>\n<tr>\n<td>Load Cell 0782 \u2013 300t<\/td>\n<td>71210169<\/td>\n<\/tr>\n<tr>\n<td>Upper Receiver \u2013 up to 50t<\/td>\n<td>61039191<\/td>\n<\/tr>\n<tr>\n<td>Lower Receiver \u2013 up to 50t<\/td>\n<td>61039190<\/td>\n<\/tr>\n<tr>\n<td>0782 Bottom Gasket<\/td>\n<td>68000443<\/td>\n<\/tr>\n<tr>\n<td>Receiver Kit SS 0782 \u2013 100t<\/td>\n<td>72209873<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Bolded entries are stocked<\/p>\n<p><strong>0782 Load Cell Cable Colours<\/strong><\/p>\n<table width=\"100%\">\n<thead>\n<tr>\n<th>Colour<\/th>\n<th>Function<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Green<\/td>\n<td>+ Excitation<\/td>\n<\/tr>\n<tr>\n<td>Black<\/td>\n<td>\u2013 Excitation<\/td>\n<\/tr>\n<tr>\n<td>White<\/td>\n<td>+ Signal<\/td>\n<\/tr>\n<tr>\n<td>Red<\/td>\n<td>\u2013 Signal<\/td>\n<\/tr>\n<tr>\n<td>Yellow<\/td>\n<td>+ Sense<\/td>\n<\/tr>\n<tr>\n<td>Blue<\/td>\n<td>\u2013 Sense<\/td>\n<\/tr>\n<tr>\n<td>Yellow (long)<\/td>\n<td>Shield<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p><strong>Every 0782 high capacity load cell features:<\/strong><br \/>\n\u2022 OIML C3 and NTEP IIILM 10.000d approvals<br \/>\n(20t\u2013100t)<br \/>\n\u2022 ATEX Zone1\/2 and 21\/22 approvals<br \/>\n\u2022 FM Class I,II,III Div 1 approvals<br \/>\n\u2022 Stainless steel (20t\u2013200t)<br \/>\n\u2022 Hermetically sealed design<br \/>\n\u2022 IP68 protection class<br \/>\nThe 0782 is approved for use in various applications in Europe, Asia, America and almost everywhere else in the world. If an approval is required, the 0782 probably already complies.<br \/>\nThe 0782 load cell is even approved for hazardous areas.<\/p>\n","protected":false},"featured_media":285449,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5114],"product_cat":[3391],"product_tag":[5346,5347,5348,5310,5097],"class_list":{"0":"post-285464","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-mettler-toledo","7":"product_cat-canister-load-cell","8":"product_tag-0782-en","9":"product_tag-canister-load-cells-en","10":"product_tag-high-capacity-2-en","11":"product_tag-mettler-toredo-en","12":"product_tag--en","14":"first","15":"instock","16":"taxable","17":"shipping-taxable","18":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>METTLER TOREDO \/ 0782 \/ High Capacity Canister Load Cell - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"Every 0782 high capacity load cell features: \u2022 OIML C3 and NTEP IIILM 10.000d approvals (20t\u2013100t) \u2022 ATEX Zone1\/2 and 21\/22 approvals \u2022 FM Class I,II,III Div 1 approvals \u2022 Stainless steel (20t\u2013200t) \u2022 Hermetically sealed design \u2022 IP68 protection class The 0782 is approved for use in various applications in Europe, Asia, America and almost everywhere else in the world. If an approval is required, the 0782 probably already complies. The 0782 load cell is even approved for hazardous areas.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/product\/mettler-toredo-0782-high-capacity-canister-load-cell\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"METTLER TOREDO \/ 0782 \/ High Capacity Canister Load Cell\" \/>\n<meta property=\"og:description\" content=\"Every 0782 high capacity load cell features: \u2022 OIML C3 and NTEP IIILM 10.000d approvals (20t\u2013100t) \u2022 ATEX Zone1\/2 and 21\/22 approvals \u2022 FM Class I,II,III Div 1 approvals \u2022 Stainless steel (20t\u2013200t) \u2022 Hermetically sealed design \u2022 IP68 protection class The 0782 is approved for use in various applications in Europe, Asia, America and almost everywhere else in the world. If an approval is required, the 0782 probably already complies. The 0782 load cell is even approved for hazardous areas.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/product\/mettler-toredo-0782-high-capacity-canister-load-cell\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-21T00:12:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"736\" \/>\n\t<meta property=\"og:image:height\" content=\"751\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/mettler-toredo-0782-high-capacity-canister-load-cell\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/mettler-toredo-0782-high-capacity-canister-load-cell\\\/\",\"name\":\"METTLER TOREDO \\\/ 0782 \\\/ High Capacity Canister Load Cell - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/mettler-toredo-0782-high-capacity-canister-load-cell\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/mettler-toredo-0782-high-capacity-canister-load-cell\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/0782_1.png\",\"datePublished\":\"2025-11-20T07:41:45+00:00\",\"dateModified\":\"2025-11-21T00:12:29+00:00\",\"description\":\"Every 0782 high capacity load cell features: \u2022 OIML C3 and NTEP IIILM 10.000d approvals (20t\u2013100t) \u2022 ATEX Zone1\\\/2 and 21\\\/22 approvals \u2022 FM Class I,II,III Div 1 approvals \u2022 Stainless steel (20t\u2013200t) \u2022 Hermetically sealed design \u2022 IP68 protection class The 0782 is approved for use in various applications in Europe, Asia, America and almost everywhere else in the world. If an approval is required, the 0782 probably already complies. The 0782 load cell is even approved for hazardous areas.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/mettler-toredo-0782-high-capacity-canister-load-cell\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/mettler-toredo-0782-high-capacity-canister-load-cell\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/mettler-toredo-0782-high-capacity-canister-load-cell\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/0782_1.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/0782_1.png\",\"width\":736,\"height\":751},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/mettler-toredo-0782-high-capacity-canister-load-cell\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"METTLER TOREDO \\\/ 0782 \\\/ High Capacity Canister Load Cell\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/product\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"METTLER TOREDO \/ 0782 \/ High Capacity Canister Load Cell - CAS Scale Korea Co., Ltd.","description":"Every 0782 high capacity load cell features: \u2022 OIML C3 and NTEP IIILM 10.000d approvals (20t\u2013100t) \u2022 ATEX Zone1\/2 and 21\/22 approvals \u2022 FM Class I,II,III Div 1 approvals \u2022 Stainless steel (20t\u2013200t) \u2022 Hermetically sealed design \u2022 IP68 protection class The 0782 is approved for use in various applications in Europe, Asia, America and almost everywhere else in the world. If an approval is required, the 0782 probably already complies. The 0782 load cell is even approved for hazardous areas.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/product\/mettler-toredo-0782-high-capacity-canister-load-cell\/","og_locale":"en_US","og_type":"article","og_title":"METTLER TOREDO \/ 0782 \/ High Capacity Canister Load Cell","og_description":"Every 0782 high capacity load cell features: \u2022 OIML C3 and NTEP IIILM 10.000d approvals (20t\u2013100t) \u2022 ATEX Zone1\/2 and 21\/22 approvals \u2022 FM Class I,II,III Div 1 approvals \u2022 Stainless steel (20t\u2013200t) \u2022 Hermetically sealed design \u2022 IP68 protection class The 0782 is approved for use in various applications in Europe, Asia, America and almost everywhere else in the world. If an approval is required, the 0782 probably already complies. The 0782 load cell is even approved for hazardous areas.","og_url":"https:\/\/casscale.net\/en\/product\/mettler-toredo-0782-high-capacity-canister-load-cell\/","og_site_name":"CAS Scale Korea Co., Ltd.","article_modified_time":"2025-11-21T00:12:29+00:00","og_image":[{"width":736,"height":751,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/product\/mettler-toredo-0782-high-capacity-canister-load-cell\/","url":"https:\/\/casscale.net\/en\/product\/mettler-toredo-0782-high-capacity-canister-load-cell\/","name":"METTLER TOREDO \/ 0782 \/ High Capacity Canister Load Cell - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/product\/mettler-toredo-0782-high-capacity-canister-load-cell\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/product\/mettler-toredo-0782-high-capacity-canister-load-cell\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_1.png","datePublished":"2025-11-20T07:41:45+00:00","dateModified":"2025-11-21T00:12:29+00:00","description":"Every 0782 high capacity load cell features: \u2022 OIML C3 and NTEP IIILM 10.000d approvals (20t\u2013100t) \u2022 ATEX Zone1\/2 and 21\/22 approvals \u2022 FM Class I,II,III Div 1 approvals \u2022 Stainless steel (20t\u2013200t) \u2022 Hermetically sealed design \u2022 IP68 protection class The 0782 is approved for use in various applications in Europe, Asia, America and almost everywhere else in the world. If an approval is required, the 0782 probably already complies. The 0782 load cell is even approved for hazardous areas.","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/product\/mettler-toredo-0782-high-capacity-canister-load-cell\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/product\/mettler-toredo-0782-high-capacity-canister-load-cell\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/product\/mettler-toredo-0782-high-capacity-canister-load-cell\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_1.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/0782_1.png","width":736,"height":751},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/product\/mettler-toredo-0782-high-capacity-canister-load-cell\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"METTLER TOREDO \/ 0782 \/ High Capacity Canister Load Cell"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/product\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/285464","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=285464"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/285449"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=285464"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=285464"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=285464"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=285464"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}