{"id":285514,"date":"2025-11-21T11:11:38","date_gmt":"2025-11-21T02:11:38","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/mettler-toredo-sls510-s-type-tension-load-cell\/"},"modified":"2025-11-21T11:11:38","modified_gmt":"2025-11-21T02:11:38","slug":"mettler-toredo-sls510-s-type-tension-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/mettler-toredo-sls510-s-type-tension-load-cell\/","title":{"rendered":"METTLER TOREDO \/ SLS510 \/ S-Type Tension Load Cell"},"content":{"rendered":"<h4>SLS510 S-Type Tension Load Cell<\/h4>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-285503\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLS410_2-800x202.png\" alt=\"\" width=\"100%\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLS410_2-800x202.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLS410_2-768x194.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLS410_2-600x151.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLS410_2-64x16.png 64w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLS410_2.png 1277w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><strong>Tension Weighing<\/strong><br \/>\nUse the SLS510 in tension weighing applications requiring Stainless Steel Load Cells to convert suspended hoppers or other hanging devices into a weighing system. The cell can also be used to convert mechanical scales to electronic. The robust and economical design is suitable for use in industrial environments requiring a higher degree of corrosion protection.<\/p>\n<p><strong>Robust Strain Gauge Design<\/strong><br \/>\nThe SLS510 load cell uses a reliable Strain Gage design with excellent measurement stability. The high sensitivity output enables the use of economic weight indicators, providing a valuable low-cost solution. The wide capacity range offers the optimum selection to maximize signal for your application.<\/p>\n<p><strong>Inch Threads and Lb Capacities<\/strong><br \/>\nThe METTLER TOLEDO SLS510 load cell is available with Inch threads to match the commonly available standards. Due to this common mechanical interface the SLS510 can be easily integrated into most systems.<\/p>\n<p><strong>Tension Weigh Mount<\/strong><br \/>\nThe optional SWS310 Tension Weigh Module provides a complete solution to integrate into your system. Due to the optimized design the best weighing performance is guaranteed. The load cell is electrically isolated from the rods, while the ground strap provides a bypass for current, thus protecting against lightning and welding damage.<\/p>\n<table width=\"100%\">\n<thead>\n<tr>\n<th colspan=\"2\">Load Cell Parameter<\/th>\n<th>Unit of measure<\/th>\n<th colspan=\"9\">Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Rated Capacity (R.C.)<\/td>\n<td><\/td>\n<td>lb<\/td>\n<td>50<\/td>\n<td>100200300<\/td>\n<td>50075010001500<\/td>\n<td>2000<\/td>\n<td>3000<\/td>\n<td>5000<\/td>\n<td>10,000<\/td>\n<td>15,000<\/td>\n<td>20.000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated Output<\/td>\n<td>mV\/V @ R.C.<\/td>\n<td colspan=\"9\">3.000 \u00b1 0.25%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Zero Load Output<\/td>\n<td>% R.C.<\/td>\n<td colspan=\"9\">1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Combined Error2<\/td>\n<td>% R.C.<\/td>\n<td colspan=\"9\">\u2264 0.02<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Repeatability Error<\/td>\n<td>% A.L.3<\/td>\n<td colspan=\"9\">\u2264 0.01<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Creep, 30 Minutes Use<\/td>\n<td>% A.L.<\/td>\n<td colspan=\"9\">\u2264 0.017<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Temperature Effect on<\/td>\n<td>Min Dead Load Output<\/td>\n<td>% R.C.\/\u00b0C (&#8230;\/\u00b0F0)<\/td>\n<td colspan=\"9\">\u2264 0.0015 (0.00083)<\/td>\n<\/tr>\n<tr>\n<td>Sensitivity<\/td>\n<td>% R.C.\/\u00b0C (&#8230;\/\u00b0F0)<\/td>\n<td colspan=\"9\">\u2264 0.0009 (0.0005)<\/td>\n<\/tr>\n<tr>\n<td>Compensated<\/td>\n<td>\u00b0C (\u00b0F)<\/td>\n<td colspan=\"9\">-10 ~ +40 (+14 ~ +104)<\/td>\n<\/tr>\n<tr>\n<td>Operating<\/td>\n<td>\u00b0C (\u00b0F)<\/td>\n<td colspan=\"9\">-35 ~ +70 (-31 ~ +158)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\">OIML \/European Approval4<\/td>\n<td>European Cert No.<\/td>\n<td><\/td>\n<td colspan=\"9\">D09-08.25<\/td>\n<\/tr>\n<tr>\n<td>Class<\/td>\n<td><\/td>\n<td colspan=\"9\">C3<\/td>\n<\/tr>\n<tr>\n<td>nmax<\/td>\n<td><\/td>\n<td colspan=\"9\">3000<\/td>\n<\/tr>\n<tr>\n<td>Y<\/td>\n<td><\/td>\n<td colspan=\"2\">7000<\/td>\n<td colspan=\"4\">10,000<\/td>\n<td colspan=\"3\">12,000<\/td>\n<\/tr>\n<tr>\n<td>PLC<\/td>\n<td><\/td>\n<td colspan=\"9\">0.7<\/td>\n<\/tr>\n<tr>\n<td>Humidity Symbol<\/td>\n<td><\/td>\n<td colspan=\"9\">none<\/td>\n<\/tr>\n<tr>\n<td>Min. Dead Load<\/td>\n<td><\/td>\n<td colspan=\"9\">0<\/td>\n<\/tr>\n<tr>\n<td>Z<\/td>\n<td><\/td>\n<td colspan=\"9\">3000<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">NTEP Approval4<\/td>\n<td>Number<\/td>\n<td><\/td>\n<td colspan=\"8\">11-020<\/td>\n<td rowspan=\"5\">NA<\/td>\n<\/tr>\n<tr>\n<td>Class<\/td>\n<td><\/td>\n<td colspan=\"8\">Class III, IIIL<\/td>\n<\/tr>\n<tr>\n<td>nmax<\/td>\n<td><\/td>\n<td colspan=\"8\">Class III = 5000,Class IIIL = 10,000<\/td>\n<\/tr>\n<tr>\n<td>Vmin (Class III)<\/td>\n<td>lb<\/td>\n<td>0.002<\/td>\n<td>0.0040.0080.012<\/td>\n<td>0.0200.0300.0400.060<\/td>\n<td>0.080<\/td>\n<td>0.120<\/td>\n<td>0.200<\/td>\n<td>0.400<\/td>\n<td>0.600<\/td>\n<\/tr>\n<tr>\n<td>Min. Dead Load<\/td>\n<td>lb<\/td>\n<td>2<\/td>\n<td>2<\/td>\n<td>551010<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">ATEX Approval4<\/td>\n<td>Number, cat 1<\/td>\n<td><\/td>\n<td colspan=\"9\">FM09ATEX0048X<\/td>\n<\/tr>\n<tr>\n<td>Number, cat 3<\/td>\n<td><\/td>\n<td colspan=\"9\">FM09ATEX0049X<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Rating<\/td>\n<td><\/td>\n<td colspan=\"9\">II 1 GEx ia IIC T4 Ta=-20\u00b0C to +40\u00b0C; IP67<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"9\">II 1 D Ex iaD T73\u00b0C; IP67<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"9\">II 1 G Ex nL IIC T4 Ta=-20\u00b0C to +40\u00b0C; IP67<\/td>\n<\/tr>\n<tr>\n<td>Entity Parameters<\/td>\n<td><\/td>\n<td colspan=\"9\">Ui=20V, Ii=600mA, Pi=6W, Ci=12nF, Li=40\u03bcH<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"9\">FM Approval, USA \/ Canada4<\/td>\n<td>Number<\/td>\n<td><\/td>\n<td colspan=\"9\">3036007 \/ 3036007C<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Rating<\/td>\n<td><\/td>\n<td colspan=\"9\">IS \/ I,II,III \/ 1 \/ ABCDEFG \/ T4<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"9\">I,II,III \/ 2 \/ABCDFG \/ T4<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"9\">Class 1, Zone 0, AEx, ia IIC T4<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"9\">Class 1, Zone 0, Ex, ia IIC T4<\/td>\n<\/tr>\n<tr>\n<td>Rating (USA only)<\/td>\n<td><\/td>\n<td colspan=\"9\">Class 1, Zone 2, GroupIICT4<\/td>\n<\/tr>\n<tr>\n<td>Rating (Canada only)<\/td>\n<td><\/td>\n<td colspan=\"9\">Ex nL IIC T4<\/td>\n<\/tr>\n<tr>\n<td>Entity Parameters<\/td>\n<td><\/td>\n<td colspan=\"9\">Vmax=20V, Imax=600mA, Pi=6W, Ci=12nF, Li=40\u03bcH<\/td>\n<\/tr>\n<tr>\n<td>System Drawing No.<\/td>\n<td><\/td>\n<td colspan=\"9\">175295R<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Excitation Voltage<\/td>\n<td>Recommended<\/td>\n<td>V AC\/DC<\/td>\n<td colspan=\"9\">10<\/td>\n<\/tr>\n<tr>\n<td>Maximum<\/td>\n<td>V AC\/DC<\/td>\n<td colspan=\"9\">18<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Terminal Resistance<\/td>\n<td>Excitation<\/td>\n<td>\u03a9<\/td>\n<td colspan=\"9\">430 \u00b1 60<\/td>\n<\/tr>\n<tr>\n<td>Output<\/td>\n<td>\u03a9<\/td>\n<td colspan=\"9\">351 \u00b1 2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Insulation resistance at 50 VDC<\/td>\n<td>M\u2126<\/td>\n<td colspan=\"9\">&gt; 5000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Breakdown voltage<\/td>\n<td>V AC<\/td>\n<td colspan=\"9\">&gt;500<\/td>\n<\/tr>\n<tr>\n<th rowspan=\"4\">Material<\/th>\n<th>Spring element<\/th>\n<th><\/th>\n<th colspan=\"9\">Stainless Steel<\/th>\n<\/tr>\n<tr>\n<th>Enclosure<\/th>\n<th><\/th>\n<th colspan=\"9\">Stainless Steel<\/th>\n<\/tr>\n<tr>\n<th>Cable entry fitting<\/th>\n<th><\/th>\n<th colspan=\"9\">Stainless Steel<\/th>\n<\/tr>\n<tr>\n<th>Cable<\/th>\n<th><\/th>\n<th colspan=\"9\">Polyurethane<\/th>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Protection<\/td>\n<td>Type<\/td>\n<td><\/td>\n<td colspan=\"9\">Potted with Metal Cover<\/td>\n<\/tr>\n<tr>\n<td>IP Rating<\/td>\n<td><\/td>\n<td colspan=\"9\">IP67<\/td>\n<\/tr>\n<tr>\n<td>NEMA Rating<\/td>\n<td><\/td>\n<td colspan=\"9\">NEMA 6 \/ 6P<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Load limit<\/td>\n<td>Safe<\/td>\n<td rowspan=\"2\">% R.C.<\/td>\n<td colspan=\"9\">150<\/td>\n<\/tr>\n<tr>\n<td>Ultimate<\/td>\n<td colspan=\"9\">300<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Safe dynamic load<\/td>\n<td>% R.C.<\/td>\n<td colspan=\"9\">70<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Fatigue life<\/td>\n<td>Cycles @ R.C.<\/td>\n<td colspan=\"9\">1,000,000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Direction of loading<\/td>\n<td><\/td>\n<td colspan=\"9\">Tension<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Deflection @ R.C., nominal<\/td>\n<td>mm (in)<\/td>\n<td colspan=\"2\">0.18[0.007]<\/td>\n<td>0.22[0.009]<\/td>\n<td>0.29[0.011]<\/td>\n<td>0.37[0.014]<\/td>\n<td colspan=\"2\">0.74[0.029]<\/td>\n<td>0.78[0.031]<\/td>\n<td>0.57[0.022]<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">Weight, nominal<\/td>\n<td rowspan=\"2\">kg (lb)<\/td>\n<td colspan=\"2\">0.45<\/td>\n<td colspan=\"2\">0.7<\/td>\n<td>0.9<\/td>\n<td>1.6<\/td>\n<td>1.8<\/td>\n<td>3<\/td>\n<td>7.3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">[1.0]<\/td>\n<td colspan=\"2\">[1.6]<\/td>\n<td>[2.0]<\/td>\n<td>[3.4]<\/td>\n<td>[4.0]<\/td>\n<td>[6.6]<\/td>\n<td>[16.1]<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Cable length<\/td>\n<td>m (ft)<\/td>\n<td colspan=\"9\">6 (19.7)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Overload protection<\/td>\n<td><\/td>\n<td colspan=\"9\">No<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<ol>\n<li>Error due to the combined effect of non-linearity and hysteresis<\/li>\n<li>Typical values The sum of errors due to Combined Error and Temperature Effect on Sensitivity comply with the requirements of OIML<\/li>\n<li>L. = Applied Load<\/li>\n<li>Refer to\u00a0 certificate\u00a0 for\u00a0 complete\u00a0 information:\u00a0 <a href=\"http:\/\/glo.mt.com\/global\/en\/home\/search\/compliance.html\/compliance\/\">http:\/\/glo.mt.com\/global\/en\/home\/search\/compliance.html\/compliance\/<\/a><\/li>\n<\/ol>\n<p><strong>SLS510<\/strong> <strong>Load<\/strong> <strong>Cell<\/strong> <strong>Dimensional<\/strong> <strong>Drawing<\/strong> <strong>mm<\/strong> <strong>[inch]<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-285512 size-full\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLS510_2.png\" alt=\"\" width=\"687\" height=\"439\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLS510_2.png 687w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLS510_2-626x400.png 626w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLS510_2-600x383.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLS510_2-64x41.png 64w\" sizes=\"(max-width: 687px) 100vw, 687px\" \/><\/p>\n<p><strong>Dimensions (inch [mm]) and Data<\/strong><\/p>\n<table width=\"100%\">\n<thead>\n<tr>\n<th>Capacity<\/th>\n<th>H<\/th>\n<th>H \/ 2<\/th>\n<th>L<\/th>\n<th>L \/ 2<\/th>\n<th>T [2x]<\/th>\n<th>W<\/th>\n<th>W \/ 2<\/th>\n<th>W1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>50 &#8211; 300 lb<\/td>\n<td>2.40 [61.0]<\/td>\n<td>1.20 [30.5]<\/td>\n<td>2.00 [50.8]<\/td>\n<td>1.00 [25.4]<\/td>\n<td>1\/4 &#8211; 28UNF X 0.35 DP<\/td>\n<td>0.46 [11.7]<\/td>\n<td>0.23 [5.8]<\/td>\n<td>0.59 [15.1]<\/td>\n<\/tr>\n<tr>\n<td>500 &#8211; 1,500lb<\/td>\n<td>2.40 [61.0]<\/td>\n<td>1.20 [30.5]<\/td>\n<td>2.00 [50.8]<\/td>\n<td>1.00 [25.4]<\/td>\n<td>1\/2 &#8211; 20UNF X 0.35 DP<\/td>\n<td>0.71 [18.0]<\/td>\n<td>0.36 [9.0]<\/td>\n<td>0.84 [21.4]<\/td>\n<\/tr>\n<tr>\n<td>2,000 lb<\/td>\n<td>2.40 [61.0]<\/td>\n<td>1.20 [30.5]<\/td>\n<td>2.00 [50.8]<\/td>\n<td>1.00 [25.4]<\/td>\n<td>1\/2 &#8211; 20UNF X 0.35 DP<\/td>\n<td>0.96 [24.4]<\/td>\n<td>0.48 [12.2]<\/td>\n<td>1.09 [27.8]<\/td>\n<\/tr>\n<tr>\n<td>3,000 lb<\/td>\n<td>3.90 [99.1]<\/td>\n<td>1.95 [49.5]<\/td>\n<td>3.00 [76.2]<\/td>\n<td>1.5 [38.1]<\/td>\n<td>1\/2 &#8211; 20UNF X 0.55 DP<\/td>\n<td>0.96 [24.4]<\/td>\n<td>0.48 [12.2]<\/td>\n<td>1.09 [27.8]<\/td>\n<\/tr>\n<tr>\n<td>5,000 lb<\/td>\n<td>3.90 [99.1]<\/td>\n<td>1.95 [49.5]<\/td>\n<td>3.00 [76.2]<\/td>\n<td>1.5 [38.1]<\/td>\n<td>3\/4 &#8211; 16UNF X 0.55 DP<\/td>\n<td>0.96 [24.4]<\/td>\n<td>0.48 [12.2]<\/td>\n<td>1.09 [27.8]<\/td>\n<\/tr>\n<tr>\n<td>10,000 lb<\/td>\n<td>3.90 [99.1]<\/td>\n<td>1.95 [49.5]<\/td>\n<td>2.94 [74.7]<\/td>\n<td>1.47 [37.31]<\/td>\n<td>3\/4 &#8211; 16UNF X 0.62 DP<\/td>\n<td>1.21 [30.7]<\/td>\n<td>0.61 [15.4]<\/td>\n<td>1.34 [34.1]<\/td>\n<\/tr>\n<tr>\n<td>15,000 lb<\/td>\n<td>5.50 [139.7]<\/td>\n<td>2.75 [69.9]<\/td>\n<td>3.44 [87.4]<\/td>\n<td>1.72 [43.7]<\/td>\n<td>1 &#8211; 14UNF X 1.06 DP<\/td>\n<td>1.46 [37]<\/td>\n<td>0.73 [18.5]<\/td>\n<td>1.59 [40.4]<\/td>\n<\/tr>\n<tr>\n<td>20,000 lb<\/td>\n<td>7.00 [177.8]<\/td>\n<td>3.50 [88.9]<\/td>\n<td>4.44 [112.8]<\/td>\n<td>2.22 [56.4]<\/td>\n<td>1 1\/4 &#8211; 12UNF X 1.56 DP<\/td>\n<td>1.69 [42.9]<\/td>\n<td>0.845 [21.5]<\/td>\n<td>1.82 [46.2]<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>SLS510 Load Cell Order Information<\/strong><\/p>\n<table width=\"100%\">\n<thead>\n<tr>\n<th>Model Number<\/th>\n<th>Item Number<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SLS510 Load Cell, 50lb<\/td>\n<td>61040268<\/td>\n<\/tr>\n<tr>\n<td>SLS510 Load Cell, 100lb<\/td>\n<td>61040269<\/td>\n<\/tr>\n<tr>\n<td>SLS510 Load Cell, 200lb<\/td>\n<td>61040270<\/td>\n<\/tr>\n<tr>\n<td>SLS510 Load Cell, 3000lb<\/td>\n<td>61040271<\/td>\n<\/tr>\n<tr>\n<td>SLS510 Load Cell, 500lb<\/td>\n<td>61040272<\/td>\n<\/tr>\n<tr>\n<td>SLS510 Load Cell, 750lb<\/td>\n<td>61040273<\/td>\n<\/tr>\n<tr>\n<td>SLS510 Load Cell, 1000lb<\/td>\n<td>61040274<\/td>\n<\/tr>\n<tr>\n<td>SLS510 Load Cell, 1500lb<\/td>\n<td>61040275<\/td>\n<\/tr>\n<tr>\n<td>SLS510 Load Cell, 2000lb<\/td>\n<td>61040276<\/td>\n<\/tr>\n<tr>\n<td>SLS510 Load Cell, 3000lb<\/td>\n<td>61040277<\/td>\n<\/tr>\n<tr>\n<td>SLS510 Load Cell, 5000lb<\/td>\n<td>61040278<\/td>\n<\/tr>\n<tr>\n<td>SLS510 Load Cell, 10,000lb<\/td>\n<td>61040279<\/td>\n<\/tr>\n<tr>\n<td>SLS510 Load Cell, 15,000lb<\/td>\n<td>61040306<\/td>\n<\/tr>\n<tr>\n<td>SLS510 Load Cell, 20,000lb<\/td>\n<td>61040307<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>SLS510\u00a0Load\u00a0Cell\u00a0Cable\u00a0Colors<\/strong><\/p>\n<table width=\"100%\">\n<thead>\n<tr>\n<th>Color<\/th>\n<th>Function<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Red<\/td>\n<td>+ Excitation<\/td>\n<\/tr>\n<tr>\n<td>Black<\/td>\n<td>&#8211; Excitation<\/td>\n<\/tr>\n<tr>\n<td>Green<\/td>\n<td>+ Signal<\/td>\n<\/tr>\n<tr>\n<td>White<\/td>\n<td>&#8211; Signal<\/td>\n<\/tr>\n<tr>\n<td>Bare<\/td>\n<td>Shield<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Use the SLS510 when better corrosion protection is required and weighing performance cannot be compromised. Every SLS510 load cell features:<\/p>\n<p>\u2022 OIML C3 and NTEP approval<br \/>\n\u2022 ATEX and FM approvals<br \/>\n\u2022 Reliable Strain Gauge design<br \/>\n\u2022 Standard mechanical interface\u2022 Robust design, Stainless steel<br \/>\n\u2022 High output signal 3mV\/V<br \/>\n\u2022 Potted; IP67 Protection<\/p>\n","protected":false},"featured_media":285511,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5114],"product_cat":[3368,3388],"product_tag":[5310,5372,5373],"class_list":{"0":"post-285514","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-mettler-toledo","7":"product_cat-s-type-load-cell","8":"product_cat-tension-load-cell","9":"product_tag-mettler-toredo-en","10":"product_tag-s-type-tension-load-cell-en","11":"product_tag-sls510-en","13":"first","14":"instock","15":"taxable","16":"shipping-taxable","17":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/285514","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=285514"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/285511"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=285514"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=285514"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=285514"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=285514"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}