{"id":285528,"date":"2025-11-21T11:37:51","date_gmt":"2025-11-21T02:37:51","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/mettler-toredo-slp33xd-iol-smart-load-cell\/"},"modified":"2025-11-21T11:37:51","modified_gmt":"2025-11-21T02:37:51","slug":"mettler-toredo-slp33xd-iol-smart-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/mettler-toredo-slp33xd-iol-smart-load-cell\/","title":{"rendered":"METTLER TOREDO \/ SLP33xD-IOL \/ Smart Load Cell"},"content":{"rendered":"<h4>SLP33xD-IOL Smart Load Cell<\/h4>\n<p><strong><img decoding=\"async\" class=\"alignnone size-medium wp-image-285518\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_1-800x195.png\" alt=\"\" width=\"100%\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_1-800x195.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_1-768x187.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_1-600x146.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_1-64x16.png 64w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_1.png 1349w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/strong><\/p>\n<p><strong>Integrated Connectivity<\/strong><br \/>\nPLC connectivity is integrated in the load cell; no additional device is required. This saves space in the machine and\/or in the control cabinet and reduces complexity, so that you can streamline sensor integration without expert knowledge.<\/p>\n<p><strong>High Precision<\/strong><br \/>\nLoad cells are available with OIML C6 and C3 class. TwinCalTM calibration technology supports loading and unloading applications. Onboard filtering and adjustment for temperature changes enable precise weighing results.<\/p>\n<p><strong>High-Speed Weighing<\/strong><br \/>\nThe load cell provides 200 updates per second (200 Hz), which supports highspeed weighing applications. Machine designs can be optimized for high throughput and increased productivity.<\/p>\n<p><strong>Advanced Intelligence<\/strong><br \/>\nCondition monitoring and Smart5TM alarms ensure the system is performing as expected and allow quick reaction in case of issues. Achieve a new level of confidence in your machine performance.<\/p>\n<p><strong>Technical Specifications<\/strong><\/p>\n<table width=\"100%\">\n<thead>\n<tr>\n<th colspan=\"2\">Parameter<\/th>\n<th>unit of measure<\/th>\n<th colspan=\"15\">Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td colspan=\"2\">Model No.<\/td>\n<td><\/td>\n<td colspan=\"5\">SLP331D-IOL<\/td>\n<td colspan=\"4\">SLP332D-IOL<\/td>\n<td colspan=\"6\">SLP333D-IOL<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated Capacity (R.C.)<\/td>\n<td>kg(lb)<\/td>\n<td>10(22)<\/td>\n<td>20(44)<\/td>\n<td>30(66)<\/td>\n<td>50(110)<\/td>\n<td>100(220)<\/td>\n<td>30(66)<\/td>\n<td>50(110)<\/td>\n<td>100(220)<\/td>\n<td>200(440)<\/td>\n<td>50(110)<\/td>\n<td>100(220)<\/td>\n<td>150(330)<\/td>\n<td>200(440)<\/td>\n<td>300(660)<\/td>\n<td>500(1100)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Noisefree Resolution<\/td>\n<td><\/td>\n<td colspan=\"15\">C3: 100 000\/ C6: 300000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Zero load Output<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"15\">&lt; 1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Combined Error (1)(2)<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"15\">C3\/IIIM n:5: \u2264 0.018 \/ C6\/IIIM n:10: \u2264 0.012<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Repeatability Error<\/td>\n<td>%A.L (3)<\/td>\n<td colspan=\"15\">C3\/IIIM n:5: \u2264 0.01 \/ C6\/IIIM n:10: \u2264 0.005<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Creep, 30 minute<\/td>\n<td>%A.L.<\/td>\n<td colspan=\"15\">C3\/IIIM n:5: \u2264 0.02 \/ C6\/IIIM n:10: \u2264 0.01<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Min. Dead Load Output Return(DR), 30 min.<\/td>\n<td>%A.L.<\/td>\n<td colspan=\"15\">C3\/IIIM n:5: \u2264 0.0167 \/ C6\/IIIM n:10: \u2264 0.0083<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Temperature Effect on<\/td>\n<td>Min. Dead load Output<\/td>\n<td>%R.C.\/\u00b0C (..\/\u00b0F)<\/td>\n<td colspan=\"15\">C3\/IIIMn:5: \u2264 0.00107(0.0006) \/ C6\/IIIM n:10: \u2264 0.00064 (0.0004)<\/td>\n<\/tr>\n<tr>\n<td>Sensitivity(2)<\/td>\n<td>%A.L.\/\u00b0C (..\/\u00b0F)<\/td>\n<td colspan=\"15\">C3\/IIIM n:5: \u2264 0.0013 (0.0006) \/ C6\/IIIM n:10: \u2264 0.00067(0.0003)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Temperature Range<\/td>\n<td>Compensated<\/td>\n<td rowspan=\"3\">\u00b0C (\u00b0F)<\/td>\n<td colspan=\"15\">-10 ~ +40 (+14 ~ +104)<\/td>\n<\/tr>\n<tr>\n<td>Operating<\/td>\n<td colspan=\"15\">-30 ~ +65(-22 ~ +150)<\/td>\n<\/tr>\n<tr>\n<td>Safe Storage<\/td>\n<td colspan=\"15\">-40 ~ +80(-40 ~ +176)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"9\">OIML \/EuropeanApproval4)<\/td>\n<td>Number, OIML \/ Europe<\/td>\n<td><\/td>\n<td colspan=\"15\">R60\/2017-A-NL1-23.23 \/ NMi TC12619<\/td>\n<\/tr>\n<tr>\n<td>Class<\/td>\n<td><\/td>\n<td colspan=\"15\">C3 \/ C6<\/td>\n<\/tr>\n<tr>\n<td>nmax<\/td>\n<td><\/td>\n<td colspan=\"15\">3000 \/ 6000<\/td>\n<\/tr>\n<tr>\n<td>Y<\/td>\n<td><\/td>\n<td colspan=\"15\">15000 \/ 25000<\/td>\n<\/tr>\n<tr>\n<td>PLC<\/td>\n<td><\/td>\n<td colspan=\"15\">0.8<\/td>\n<\/tr>\n<tr>\n<td>Humidity Symbol<\/td>\n<td><\/td>\n<td colspan=\"15\">none<\/td>\n<\/tr>\n<tr>\n<td>Min. dead load<\/td>\n<td>kg<\/td>\n<td colspan=\"15\">0<\/td>\n<\/tr>\n<tr>\n<td>Z<\/td>\n<td><\/td>\n<td colspan=\"15\">3000 \/ 6000<\/td>\n<\/tr>\n<tr>\n<td>Barometric PressureEffect<\/td>\n<td><\/td>\n<td colspan=\"15\">none<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">NTEPApproval4)<\/td>\n<td>Number<\/td>\n<td><\/td>\n<td colspan=\"15\">882849<\/td>\n<\/tr>\n<tr>\n<td>Accuracy Class<\/td>\n<td><\/td>\n<td colspan=\"15\">III<\/td>\n<\/tr>\n<tr>\n<td>nmax<\/td>\n<td><\/td>\n<td colspan=\"15\">9000 \/ 6000<\/td>\n<\/tr>\n<tr>\n<td>Vmin<\/td>\n<td>g<\/td>\n<td>0.4<\/td>\n<td>0.8<\/td>\n<td>1.2<\/td>\n<td>2.0<\/td>\n<td>4.0<\/td>\n<td>1.2<\/td>\n<td>2.0<\/td>\n<td>4.0<\/td>\n<td>8.0<\/td>\n<td>2.0<\/td>\n<td>4.0<\/td>\n<td>6.0<\/td>\n<td>8.0<\/td>\n<td>12.0<\/td>\n<td>20.0<\/td>\n<\/tr>\n<tr>\n<td>Min. dead load<\/td>\n<td>g<\/td>\n<td colspan=\"15\">0<\/td>\n<\/tr>\n<tr>\n<td>ATEXApproval (4)<\/td>\n<td>Number, cat. 2<\/td>\n<td><\/td>\n<td colspan=\"15\">in preparation<\/td>\n<\/tr>\n<tr>\n<td>IECExApproval (4)<\/td>\n<td>Rating<\/td>\n<td><\/td>\n<td colspan=\"15\">in preparation<\/td>\n<\/tr>\n<tr>\n<td>Factory MutualApproval(4)<\/td>\n<td>Number, USA \/ Canada<\/td>\n<td><\/td>\n<td colspan=\"15\">in preparation<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Insulation Resistance @50VDC<\/td>\n<td>M\u03a9<\/td>\n<td colspan=\"15\">\u2265 2000 (6)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Breakdown Voltage<\/td>\n<td>V AC<\/td>\n<td colspan=\"15\">\u2265 500 (6)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Supply Voltage Non-regulated<\/td>\n<td>Range (nominal)<\/td>\n<td>V DC<\/td>\n<td colspan=\"15\">10 ~ 30<\/td>\n<\/tr>\n<tr>\n<td>Typical<\/td>\n<td><\/td>\n<td colspan=\"15\">12 \/ 24<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Supply Current<\/td>\n<td>Max.<\/td>\n<td>mA<\/td>\n<td colspan=\"15\">60 (6)<\/td>\n<\/tr>\n<tr>\n<td>Typical<\/td>\n<td><\/td>\n<td colspan=\"15\">40 \/ 20<\/td>\n<\/tr>\n<tr>\n<td>Overvoltage Protection<\/td>\n<td>Max. Tested (IEEE4-95)<\/td>\n<td>A<\/td>\n<td colspan=\"15\">2000 no outdoor lightning conditions (6)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Model No.<\/th>\n<th><\/th>\n<th colspan=\"5\">SLP331D-IOL<\/th>\n<th colspan=\"4\">SLP332D-IOL<\/th>\n<th colspan=\"6\">SLP333D-IOL<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated Capacity (R.C.)<\/td>\n<td>kg (lb, nominal)<\/td>\n<td>10(22)<\/td>\n<td>20(44)<\/td>\n<td>30(66)<\/td>\n<td>50(110)<\/td>\n<td>100(220)<\/td>\n<td>30(66)<\/td>\n<td>50(110)<\/td>\n<td>100(220)<\/td>\n<td>200(440)<\/td>\n<td>50(110)<\/td>\n<td>100(220)<\/td>\n<td>150(330)<\/td>\n<td>200(440)<\/td>\n<td>300(660)<\/td>\n<td>500(1100)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Warm-up Time from Cold Start<\/td>\n<td>minutes<\/td>\n<td colspan=\"15\">5<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Communications<\/td>\n<td>Type<\/td>\n<td><\/td>\n<td colspan=\"15\">IO-Link 1.1<\/td>\n<\/tr>\n<tr>\n<td>Protocol<\/td>\n<td><\/td>\n<td colspan=\"15\">COM3<\/td>\n<\/tr>\n<tr>\n<td>Baud rate<\/td>\n<td><\/td>\n<td colspan=\"15\">up to 230.4 kbit\/sec<\/td>\n<\/tr>\n<tr>\n<td>Condition monitoring<\/td>\n<td><\/td>\n<td colspan=\"15\">Smart5\u2122, integrated LED on load cell<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Effective System Update Rate, for one cell,38400 baud rate<\/td>\n<td>Hz<\/td>\n<td colspan=\"15\">up to 200<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">ESD rating<\/td>\n<td>kV<\/td>\n<td colspan=\"15\">8 (6)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Span Stability, typical (peak to peak in 1 min)<\/td>\n<td>ppm<\/td>\n<td colspan=\"15\">&lt; 5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Immunity OIML R60<\/td>\n<td>V\/m<\/td>\n<td colspan=\"15\">10<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Material Spring Element<\/td>\n<td><\/td>\n<td colspan=\"15\">Aluminum, anodized<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Enclosure<\/td>\n<td><\/td>\n<td colspan=\"15\">Silicon potting<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Protection<\/td>\n<td>Type<\/td>\n<td><\/td>\n<td colspan=\"15\">Silicon potting<\/td>\n<\/tr>\n<tr>\n<td>IP Rating<\/td>\n<td><\/td>\n<td colspan=\"15\">IP67<\/td>\n<\/tr>\n<tr>\n<td>NEMA Rating<\/td>\n<td><\/td>\n<td colspan=\"15\">NEMA 6\/6P<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Overload Protection<\/td>\n<td><\/td>\n<td colspan=\"15\">none<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Load Limit<\/td>\n<td>Safe<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"15\">150<\/td>\n<\/tr>\n<tr>\n<td>Ultimate<\/td>\n<td><\/td>\n<td colspan=\"15\">300<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Safe Side Load<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"15\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Safe Dynamic Load<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"15\">70<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Fatigue Life<\/td>\n<td>cycles @R.C.<\/td>\n<td colspan=\"15\">&gt; 1,000,000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Direction of Loading<\/td>\n<td><\/td>\n<td colspan=\"15\">beam<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Deflection @ R.C., nominal<\/td>\n<td>mm (in)<\/td>\n<td colspan=\"5\">&lt;0.35 (0.014)<\/td>\n<td colspan=\"4\">&lt;0.25 (0.01)<\/td>\n<td colspan=\"6\">&lt;0.3 (0.012)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Max. platter size<\/td>\n<td>mm (in)<\/td>\n<td colspan=\"9\">400 x 400(15.75 x 15.75)<\/td>\n<td colspan=\"6\">600 x 600(23.62 x 23.62)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Off-center load error, R76-1<\/td>\n<td>%A.L. \/ cm (%A.L. \/ in )<\/td>\n<td colspan=\"9\">0.0049(0.012)<\/td>\n<td colspan=\"6\">0.0032(0.008)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Weight, nominal<\/td>\n<td>kg (lb)<\/td>\n<td colspan=\"9\">0.31 (0.7)<\/td>\n<td colspan=\"6\">0.91 (2)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Cable<\/td>\n<td><\/td>\n<td colspan=\"15\">M12 industrial, 5-pin, shielded recommeded<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Cable length, max.<\/td>\n<td>m (ft)<\/td>\n<td colspan=\"15\">20 (66)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connector, load cell<\/td>\n<td><\/td>\n<td colspan=\"15\">M12 industrial, 5-pin, female ( Class A )<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Mounting Screw<\/td>\n<td>Grade<\/td>\n<td><\/td>\n<td colspan=\"15\">8.8 or higher<\/td>\n<\/tr>\n<tr>\n<td>Size\/thread<\/td>\n<td>mm (in)<\/td>\n<td colspan=\"9\">M6<\/td>\n<td colspan=\"6\">M8<\/td>\n<\/tr>\n<tr>\n<td>Torque,nominal<\/td>\n<td>Nm (ft-lb)<\/td>\n<td colspan=\"9\">10 (7.5)<\/td>\n<td colspan=\"6\">25 (18)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>(1) Error due to the combined effect of non-linearity and hysteresis<br \/>\n(2) Typical values only. The sum of errors due to Combined Error and Temperature Effect on Sensitivity comply with the requirements of OIML R60 and NIST HB44.<br \/>\n(3) A.L. = Applied Load<br \/>\n(4) See certificate for complete information.<br \/>\n(5) Calculate the scale\u2019s minimum increment size by multiplying this value by the square root of the number of load cells. For non Legal-For-Trade Applications<br \/>\n(6) Values are not finalized, subject to change<\/p>\n<p><strong>Load Cell Dimensions mm [in]<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-285520 size-full\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_2.png\" alt=\"\" width=\"1103\" height=\"659\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_2.png 1103w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_2-669x400.png 669w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_2-768x459.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_2-600x358.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_2-64x38.png 64w\" sizes=\"(max-width: 1103px) 100vw, 1103px\" \/><\/p>\n<p><strong>SLP332D Smart Load Cell Mounting Dimensions<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-285522 size-full\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_3.png\" alt=\"\" width=\"1475\" height=\"826\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_3.png 1475w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_3-714x400.png 714w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_3-1400x784.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_3-768x430.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_3-600x336.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_3-64x36.png 64w\" sizes=\"(max-width: 1475px) 100vw, 1475px\" \/><\/p>\n<p><strong>SLP333D Smart Load Cell Mounting Dimensions<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-285524 size-full\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_4.png\" alt=\"\" width=\"1419\" height=\"830\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_4.png 1419w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_4-684x400.png 684w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_4-1368x800.png 1368w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_4-768x449.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_4-600x351.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_4-64x37.png 64w\" sizes=\"(max-width: 1419px) 100vw, 1419px\" \/><\/p>\n<p><strong>SLP33xD-IOL Smart Load Cell Connector Pin Definition<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>M12 Connector<\/th>\n<th>Pinning<\/th>\n<th>Signal<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"5\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-285526\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_5.png\" alt=\"\" width=\"131\" height=\"131\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_5.png 131w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_5-100x100.png 100w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/SLP33xD-IOL_5-64x64.png 64w\" sizes=\"(max-width: 131px) 100vw, 131px\" \/><\/td>\n<td>1<\/td>\n<td>L+<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>DI\/DQ<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>L-<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>C\/Q<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Not used<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Order Information<\/h3>\n<table width=\"100%\">\n<thead>\n<tr>\n<th rowspan=\"2\">Rated Capacity<\/th>\n<th colspan=\"2\">SLP331D-IOL<\/th>\n<th colspan=\"2\">SLP332D-IOL<\/th>\n<th colspan=\"2\">SLP333D-IOL<\/th>\n<\/tr>\n<tr>\n<th>C3<\/th>\n<th>C6<\/th>\n<th>C3<\/th>\n<th>C6<\/th>\n<th>C3<\/th>\n<th>C6<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>10 kg \/ 22 lb<\/td>\n<td>30801836<\/td>\n<td>30786457<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>20 kg \/ 44 lb<\/td>\n<td>30801837<\/td>\n<td>30786458<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>30 kg \/ 66 lb<\/td>\n<td>30801838<\/td>\n<td>30786459<\/td>\n<td>30801841<\/td>\n<td>30786462<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>50 kg \/ 110 lb<\/td>\n<td>30801839<\/td>\n<td>30786460<\/td>\n<td>30801842<\/td>\n<td>30786463<\/td>\n<td>30801830<\/td>\n<td>30786466<\/td>\n<\/tr>\n<tr>\n<td>100 kg \/ 220 lb<\/td>\n<td>30801840<\/td>\n<td>30786461<\/td>\n<td>30801843<\/td>\n<td>30786464<\/td>\n<td>30801831<\/td>\n<td>30786467<\/td>\n<\/tr>\n<tr>\n<td>150 kg \/ 330 lb<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>30801832<\/td>\n<td>30786468<\/td>\n<\/tr>\n<tr>\n<td>200 kg \/ 440lb<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>30801844<\/td>\n<td>30786465<\/td>\n<td>30801833<\/td>\n<td>30786469<\/td>\n<\/tr>\n<tr>\n<td>300 kg \/ 660 lb<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>30801834<\/td>\n<td>30786470<\/td>\n<\/tr>\n<tr>\n<td>500 kg \/ 1100 lb<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>30801835<\/td>\n<td>30786471<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>High-Quality Aluminum Alloy Single Point Load Cell with IO-Link Connectivity<\/p>\n<p>\u2022 Integrated connectivity saves space, reduces system complexity, and allows quick and straightforward installation.<br \/>\n\u2022 CalFreeTM technology provides factory calibration data, so the load cell is ready to measure.<br \/>\n\u2022 TwinCalTM delivers high accuracy for both loading and unloading applications.<br \/>\n\u2022 Smart5TM intelligent condition monitoring and alarms ensure easy maintenance and high machine uptime.<br \/>\n\u2022 Direct connection to PLCs, DCSs and to other host controllers and the IODD file ensure rapid integration into any kind of machine, thus development time is reduced.<\/p>\n","protected":false},"featured_media":285517,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[3383],"product_tag":[5310,5376,5377],"class_list":{"0":"post-285528","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-beam-type-load-cell","7":"product_tag-mettler-toredo-en","8":"product_tag-slp33xd-iol-en","9":"product_tag-smart-load-cell-en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/285528","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=285528"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/285517"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=285528"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=285528"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=285528"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=285528"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}