{"id":285552,"date":"2025-11-21T11:55:33","date_gmt":"2025-11-21T02:55:33","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/mettler-toredo-mt1022-single-point-load-cell\/"},"modified":"2025-11-21T11:55:33","modified_gmt":"2025-11-21T02:55:33","slug":"mettler-toredo-mt1022-single-point-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/mettler-toredo-mt1022-single-point-load-cell\/","title":{"rendered":"METTLER TOREDO \/ MT1022 \/ Single Point Load Cell"},"content":{"rendered":"<h4>MT1022 Single Point Load Cell<\/h4>\n<p>The MT1022 is the ideal solution for retail scales, small platform scales and packaging and process weighing. Due to the low profile the integration into any system is easy. The low capacity range (3 \u2013 30 kg) allows the construction of highly accurate low-capacity scales.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-285533\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/MT1022_1-800x254.png\" alt=\"\" width=\"100%\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/MT1022_1-800x254.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/MT1022_1-1400x444.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/MT1022_1-768x244.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/MT1022_1-600x190.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/MT1022_1-64x20.png 64w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/MT1022_1.png 1430w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><strong>Retail and Bench Scales<br \/>\n<\/strong>MT1022 provides the best weighing performance with such a low profile design. This saves cost in the scale design and makes an attractive low- profile product possible without com- promising on performance.<\/p>\n<p><strong>Off-Center Compensation<br \/>\n<\/strong>One load cell can be used to support a weighing platform and, due to the off- center load compensation, the MT1022 will weigh within tolerance regardless of load application point.<\/p>\n<p><strong>Robustness<br \/>\n<\/strong>MT1022 allows 50% static overload without compromising the weighing performance. The passivated aluminum provides good corrosion resistance suit- able for many industrial applications.<\/p>\n<p><strong>MT1022 Load Cell Specifications<\/strong><\/p>\n<table width=\"100%\">\n<thead>\n<tr>\n<th colspan=\"2\">Parameter<\/th>\n<th>Unit of measure<\/th>\n<th colspan=\"7\">Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td colspan=\"2\">Model No.<\/td>\n<td><\/td>\n<td colspan=\"7\">MT1022<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated capacity (R.C.)<\/td>\n<td>kg (lb, nominal)<\/td>\n<td>3 (6.6)<\/td>\n<td>5 (11)<\/td>\n<td>7 (15.4)<\/td>\n<td>10 (22)<\/td>\n<td>15 (33)<\/td>\n<td>20 (44.1)<\/td>\n<td>30 (66.1)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated output<\/td>\n<td>mV\/V @R.C.<\/td>\n<td colspan=\"7\">2 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Zero load output<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"7\">\u2264 10<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Combined error 1) 2)<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"7\">\u2264 0.016<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Repeatability error<\/td>\n<td>%A.L. 3)<\/td>\n<td colspan=\"7\">\u2264 0.01<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Creep, 30 minute<\/td>\n<td>%A.L.<\/td>\n<td colspan=\"7\">\u2264 0.0167<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Min. dead load output return (DR), 30 min<\/td>\n<td>%A.L.<\/td>\n<td colspan=\"7\">\u2264 0.0167<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Temperature effect on<\/td>\n<td>Min. dead load output<\/td>\n<td>%R.C.\/\u00b0C (..\/\u00b0F)<\/td>\n<td colspan=\"7\">\u2264 0.0014 (0.0008)<\/td>\n<\/tr>\n<tr>\n<td>Sensitivity 2)<\/td>\n<td>%A.L.\/\u00b0C (..\/\u00b0F)<\/td>\n<td colspan=\"7\">\u2264 0.0007 (0.00036)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Temperature range<\/td>\n<td>Compensated<\/td>\n<td rowspan=\"3\">\u00b0C (\u00b0F)<\/td>\n<td colspan=\"7\">-10 ~ +40 (+14 ~+104)<\/td>\n<\/tr>\n<tr>\n<td>Operating<\/td>\n<td colspan=\"7\">-40 ~ +65(-40 ~ +150)<\/td>\n<\/tr>\n<tr>\n<td>Safe storage<\/td>\n<td colspan=\"7\">-40 ~ +80(-40 ~ +176)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"9\">OIML \/ European approval 4)<\/td>\n<td>OIML Cert. No.<\/td>\n<td><\/td>\n<td colspan=\"7\">R60\/2017-A-NL1-20.05<\/td>\n<\/tr>\n<tr>\n<td>European Cert. No.<\/td>\n<td><\/td>\n<td colspan=\"7\">NMi-1902131-05<\/td>\n<\/tr>\n<tr>\n<td>Class<\/td>\n<td><\/td>\n<td colspan=\"7\">C3<\/td>\n<\/tr>\n<tr>\n<td>nmax<\/td>\n<td><\/td>\n<td colspan=\"7\">3000<\/td>\n<\/tr>\n<tr>\n<td>Y<\/td>\n<td><\/td>\n<td colspan=\"7\">9000<\/td>\n<\/tr>\n<tr>\n<td>PLC<\/td>\n<td><\/td>\n<td colspan=\"7\">0.7<\/td>\n<\/tr>\n<tr>\n<td>Humidity symbol<\/td>\n<td><\/td>\n<td colspan=\"7\">None<\/td>\n<\/tr>\n<tr>\n<td>Min. dead load<\/td>\n<td>kg (lb)<\/td>\n<td colspan=\"7\">0 (0)<\/td>\n<\/tr>\n<tr>\n<td>Z<\/td>\n<td><\/td>\n<td colspan=\"7\">3000<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">NTEP approval 4)<\/td>\n<td>Number<\/td>\n<td><\/td>\n<td colspan=\"7\">11\u2013088<\/td>\n<\/tr>\n<tr>\n<td>Class<\/td>\n<td><\/td>\n<td colspan=\"7\">III S, III M<\/td>\n<\/tr>\n<tr>\n<td>nmax<\/td>\n<td><\/td>\n<td colspan=\"7\">5000<\/td>\n<\/tr>\n<tr>\n<td>Vmin<\/td>\n<td>g(lb)<\/td>\n<td>0.3(0.0007)<\/td>\n<td>0.5(0.0011)<\/td>\n<td>0.7(0.0015)<\/td>\n<td>1(0.0022)<\/td>\n<td>1.5(0.0033)<\/td>\n<td>2(0.0044)<\/td>\n<td>3(0.0066)<\/td>\n<\/tr>\n<tr>\n<td>Min. dead load<\/td>\n<td>kg (lb)<\/td>\n<td colspan=\"7\">0 (0)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\">ATEX approval 4)<\/td>\n<td>Number, cat. 2<\/td>\n<td><\/td>\n<td colspan=\"7\">KEMA 09ATEX0003 X<\/td>\n<\/tr>\n<tr>\n<td>Number, cat. 3<\/td>\n<td><\/td>\n<td colspan=\"7\">KEMA 09ATEX0004 X<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">Rating<\/td>\n<td><\/td>\n<td colspan=\"7\">II 2 G Ex ib IICT4<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"7\">II 2 D Ex ibD21 IP66 T135\u00b0C<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"7\">II 3 G Ex nA II T4<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"7\">II 3 G Ex nL IIC T4<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"7\">II 3 D Ex tD A22 IP66 T135\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Entity parameters<\/td>\n<td><\/td>\n<td colspan=\"7\">Ui\/Un=20V, Ii=600mA, Pi=1.25W, Ci=5nF, Li=30\u03bcH<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Excitation voltage<\/td>\n<td>Recommended<\/td>\n<td rowspan=\"2\">V AC\/DC<\/td>\n<td colspan=\"7\">5 ~ 15<\/td>\n<\/tr>\n<tr>\n<td>Max.<\/td>\n<td colspan=\"7\">20<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Terminal resistance<\/td>\n<td>Excitation<\/td>\n<td rowspan=\"2\">\u03a9<\/td>\n<td colspan=\"7\">410 \u00b1 10<\/td>\n<\/tr>\n<tr>\n<td>Output<\/td>\n<td colspan=\"7\">350 \u00b1 4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Insulation resistance @50VDC<\/td>\n<td>M\u03a9<\/td>\n<td colspan=\"7\">&gt; 5000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Breakdown voltage<\/td>\n<td>V AC<\/td>\n<td colspan=\"7\">&gt; 500<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Material<\/td>\n<td>Spring element<\/td>\n<td><\/td>\n<td colspan=\"7\">Aluminium<\/td>\n<\/tr>\n<tr>\n<td>Enclosure<\/td>\n<td><\/td>\n<td colspan=\"7\">None<\/td>\n<\/tr>\n<tr>\n<td>Cable<\/td>\n<td><\/td>\n<td colspan=\"7\">PVC<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Protection<\/td>\n<td>Type<\/td>\n<td><\/td>\n<td colspan=\"7\">Potted<\/td>\n<\/tr>\n<tr>\n<td>IP Rating<\/td>\n<td><\/td>\n<td colspan=\"7\">IP 67<\/td>\n<\/tr>\n<tr>\n<td>NEMA Rating<\/td>\n<td><\/td>\n<td colspan=\"7\">NEMA 6\/6P<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Load limit<\/td>\n<td>Safe<\/td>\n<td rowspan=\"2\">%R.C.<\/td>\n<td colspan=\"7\">150<\/td>\n<\/tr>\n<tr>\n<td>Ultimate<\/td>\n<td colspan=\"7\">300<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Safe dynamic load<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"7\">70<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Fatigue life<\/td>\n<td>cycles @R.C.<\/td>\n<td colspan=\"7\">&gt; 1000000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Direction of loading<\/td>\n<td><\/td>\n<td colspan=\"7\">Beam<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Deflection @ R.C., nominal<\/td>\n<td>mm (in)<\/td>\n<td colspan=\"3\">&lt; 0.8 (0.031)<\/td>\n<td colspan=\"4\">&lt; 0.5 (0.020)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Weight, nominal<\/td>\n<td>kg (lb)<\/td>\n<td colspan=\"7\">0.5 (1.1)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Cable length<\/td>\n<td>m (ft)<\/td>\n<td colspan=\"7\">1 (3.3), 3m (6.6)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Barometric pressure effect on zero load output<\/td>\n<td>kg\/kPa (lb\/in.Hg)<\/td>\n<td colspan=\"7\">None<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Safe side load<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"7\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Overload protection<\/td>\n<td><\/td>\n<td colspan=\"7\">None<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Mounting screw<\/td>\n<td>Grade<\/td>\n<td><\/td>\n<td colspan=\"7\">12.9<\/td>\n<\/tr>\n<tr>\n<td>Size\/thread<\/td>\n<td>mm (in)<\/td>\n<td colspan=\"7\">M6x1<\/td>\n<\/tr>\n<tr>\n<td>Engaged length<\/td>\n<td>mm (in)<\/td>\n<td colspan=\"7\">12 (0.47)<\/td>\n<\/tr>\n<tr>\n<td>Torque, nominal<\/td>\n<td>N.m (ft-lb)<\/td>\n<td colspan=\"7\">10 (7.5)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Max. platter size<\/td>\n<td>cm x cm (in x in)<\/td>\n<td colspan=\"7\">35 x 35 (14 x 14)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Off center load error, R76-1<\/td>\n<td>%A.L.\/cm (..\/in)<\/td>\n<td colspan=\"7\">0.0057 (0.0145)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>1) Error due to the combined effect of non-linearity and hysteresis<br \/>\n2) Typical values only. The sum of errors due to combined error and temperature effect on sensitivity comply with the requirements of OIML R60 and NIST HB44.<br \/>\n3) A.L. = Applied Load<br \/>\n4) See certificate for complete information.<\/p>\n<p><strong>MT1022 Load Cell Dimensional Drawings mm [inch] <\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-285535 size-full\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/MT1022_2.png\" alt=\"\" width=\"1252\" height=\"793\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/MT1022_2.png 1252w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/MT1022_2-632x400.png 632w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/MT1022_2-768x486.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/MT1022_2-600x380.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/MT1022_2-64x41.png 64w\" sizes=\"(max-width: 1252px) 100vw, 1252px\" \/><\/p>\n<table width=\"100%\">\n<thead>\n<tr>\n<th>Load Cell Capacity<\/th>\n<th>A<\/th>\n<th>B<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>3, 5, 7 kg<\/td>\n<td>25.4 [1.0]<\/td>\n<td>25 mm [0.98]<\/td>\n<\/tr>\n<tr>\n<td>10, 15,20, 30 kg<\/td>\n<td>30 [1.18]<\/td>\n<td>32 mm [1.26]<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>MT1022 Load Cell Order Information<\/strong><\/p>\n<table width=\"100%\">\n<thead>\n<tr>\n<th>Description<\/th>\n<th><\/th>\n<th>Item No.<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Load cell, model no. MT1022-3kg<\/td>\n<td>1m Cable<\/td>\n<td>71201825<\/td>\n<\/tr>\n<tr>\n<td>Load cell, model no. MT1022-5kg<\/td>\n<td>1m Cable<\/td>\n<td>71201826<\/td>\n<\/tr>\n<tr>\n<td>Load cell, model no. MT1022-7kg<\/td>\n<td>1m Cable<\/td>\n<td>71201827<\/td>\n<\/tr>\n<tr>\n<td>Load cell, model no. MT1022-10kg<\/td>\n<td>1m Cable<\/td>\n<td>71207450<\/td>\n<\/tr>\n<tr>\n<td>Load cell, model no. MT1022-15kg<\/td>\n<td>1m Cable<\/td>\n<td>71201829<\/td>\n<\/tr>\n<tr>\n<td>Load cell, model no. MT1022-20kg<\/td>\n<td>1m Cable<\/td>\n<td>71201830<\/td>\n<\/tr>\n<tr>\n<td>Load cell, model no. MT1022-30kg<\/td>\n<td>1m Cable<\/td>\n<td>71207741<\/td>\n<\/tr>\n<tr>\n<td>Load cell, model no. MT1022-3kg<\/td>\n<td>3m Cable<\/td>\n<td>72208506<\/td>\n<\/tr>\n<tr>\n<td>Load cell, model no. MT1022-5kg<\/td>\n<td>3m Cable<\/td>\n<td>72208507<\/td>\n<\/tr>\n<tr>\n<td>Load cell, model no. MT1022-7kg<\/td>\n<td>3m Cable<\/td>\n<td>72208508<\/td>\n<\/tr>\n<tr>\n<td>Load cell, model no. MT1022-10kg<\/td>\n<td>3m Cable<\/td>\n<td>72208509<\/td>\n<\/tr>\n<tr>\n<td>Load cell, model no. MT1022-15kg<\/td>\n<td>3m Cable<\/td>\n<td>72208510<\/td>\n<\/tr>\n<tr>\n<td>Load cell, model no. MT1022-20kg<\/td>\n<td>3m Cable<\/td>\n<td>72208511<\/td>\n<\/tr>\n<tr>\n<td>Load cell, model no. MT1022-30kg<\/td>\n<td>3m Cable<\/td>\n<td>72208512<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>MT1022 Load Cell Cable Colours<\/strong><\/p>\n<table width=\"100%\">\n<thead>\n<tr>\n<th>Colour<\/th>\n<th>Function<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Green<\/td>\n<td>+ Excitation<\/td>\n<\/tr>\n<tr>\n<td>Black<\/td>\n<td>\u2013 Excitation<\/td>\n<\/tr>\n<tr>\n<td>Red<\/td>\n<td>+ Signal<\/td>\n<\/tr>\n<tr>\n<td>White<\/td>\n<td>\u2013 Signal<\/td>\n<\/tr>\n<tr>\n<td>Yellow<\/td>\n<td>+ Shield<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li>OIML R60 C3 approval<\/li>\n<li>NTEP 5000 III S\/M approval<\/li>\n<li>ATEX Zone 1\/2 and 21\/22 approvals<\/li>\n<li>Off-center load compensation (R76)<\/li>\n<li>350&#215;350 mm platform size<\/li>\n<li>IP67 protection class<\/li>\n<li>Passivated aluminum<\/li>\n<li>3\u201330 kg capacity range<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":285532,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5114],"product_cat":[3385],"product_tag":[5310,5383,5069,5382],"class_list":{"0":"post-285552","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-mettler-toledo","7":"product_cat-single-point-en","8":"product_tag-mettler-toredo-en","9":"product_tag-mt1022-en","10":"product_tag-single-point-load-cell-en2","11":"product_tag-single-point-load-cell-2-en","13":"first","14":"instock","15":"taxable","16":"shipping-taxable","17":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/285552","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=285552"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/285532"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=285552"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=285552"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=285552"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=285552"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}