{"id":285582,"date":"2025-11-21T14:43:12","date_gmt":"2025-11-21T05:43:12","guid":{"rendered":"https:\/\/casscale.net\/?post_type=product&#038;p=285582"},"modified":"2025-11-21T14:54:56","modified_gmt":"2025-11-21T05:54:56","slug":"mettler-toredo-il-single-point-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/mettler-toredo-il-single-point-load-cell\/","title":{"rendered":"METTLER TOREDO \/ IL \/ Single Point Load Cell"},"content":{"rendered":"<h4>IL Single Point Load Cell<\/h4>\n<p>The IL is the ideal solution for hopper and bin weighing due to high capacities and large possible platform sizes. The mounting schema allows for direct bolting to a wall. The variety of capacities allows for wide application range.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-285585\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/IL_2-800x267.png\" alt=\"\" width=\"100%\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/IL_2-800x267.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/IL_2-1400x467.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/IL_2-768x256.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/IL_2-600x200.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/IL_2-64x21.png 64w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/IL_2.png 1430w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<table width=\"100%\">\n<thead>\n<tr>\n<th colspan=\"2\">Parameter<\/th>\n<th>Unit of measure<\/th>\n<th colspan=\"5\">Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td colspan=\"2\">Model No.<\/td>\n<td><\/td>\n<td colspan=\"5\">IL<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated capacity (R.C.)<\/td>\n<td>kg (lb, nominal)<\/td>\n<td>150 (331)<\/td>\n<td>250 (441)<\/td>\n<td>500 (1102)<\/td>\n<td>1000 (2204)<\/td>\n<td>2000 (4408)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated output<\/td>\n<td>mV\/V @R.C.<\/td>\n<td colspan=\"5\">2 \u00b1 0.002<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Zero load output<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"5\">\u2264 1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Combined error 1), 2)<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"5\">\u2264 0.02<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Repeatability error<\/td>\n<td>%A.L. 3)<\/td>\n<td colspan=\"5\">\u2264 0.01<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Creep, 30 minute<\/td>\n<td>%A.L.<\/td>\n<td colspan=\"5\">\u2264 0.02<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Min. dead load outputreturn (DR), 30 min<\/td>\n<td>%A.L.<\/td>\n<td colspan=\"5\">\u2264 0.016<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Temperature effect on<\/td>\n<td>Min. dead load output<\/td>\n<td>%R.C.\/\u00b0C (..\/\u00b0F)<\/td>\n<td colspan=\"5\">\u2264 0.002 (0.001)<\/td>\n<\/tr>\n<tr>\n<td>Sensitivity 2)<\/td>\n<td>%A.L.\/\u00b0C (..\/\u00b0F)<\/td>\n<td colspan=\"5\">\u2264 0.0009 (0.0005)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Temperature range<\/td>\n<td>Compensated<\/td>\n<td>\u00b0C (\u00b0F)<\/td>\n<td colspan=\"5\">-10 to +40 (+14 to +104)<\/td>\n<\/tr>\n<tr>\n<td>Operating<\/td>\n<td>\u00b0C (\u00b0F)<\/td>\n<td colspan=\"5\">-40 to +65 (-40 to +150)<\/td>\n<\/tr>\n<tr>\n<td>Safe storage<\/td>\n<td>\u00b0C (\u00b0F)<\/td>\n<td colspan=\"5\">-40 to +80 (-40 to +176)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\">OIML \/ European approval 4)<\/td>\n<td>OIML Cert. No.<\/td>\n<td><\/td>\n<td colspan=\"5\">R60\/2000-NL-02.11<\/td>\n<\/tr>\n<tr>\n<td>European Cert. No.<\/td>\n<td><\/td>\n<td colspan=\"5\">TC 6042<\/td>\n<\/tr>\n<tr>\n<td>Class<\/td>\n<td><\/td>\n<td colspan=\"5\">C3<\/td>\n<\/tr>\n<tr>\n<td>nmax<\/td>\n<td><\/td>\n<td colspan=\"5\">3000<\/td>\n<\/tr>\n<tr>\n<td>Y<\/td>\n<td><\/td>\n<td colspan=\"5\">5000<\/td>\n<\/tr>\n<tr>\n<td>PLC<\/td>\n<td><\/td>\n<td colspan=\"5\">0.7<\/td>\n<\/tr>\n<tr>\n<td>Humidity symbol<\/td>\n<td><\/td>\n<td colspan=\"5\">None<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Excitation voltage<\/td>\n<td>Recommended<\/td>\n<td>V AC\/DC<\/td>\n<td colspan=\"5\">5 ~ 15<\/td>\n<\/tr>\n<tr>\n<td>Max.<\/td>\n<td>V AC\/DC<\/td>\n<td colspan=\"5\">20<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Terminal resistance<\/td>\n<td>Excitation<\/td>\n<td>\u03a9<\/td>\n<td colspan=\"5\">387\u00b14<\/td>\n<\/tr>\n<tr>\n<td>Output<\/td>\n<td>\u03a9<\/td>\n<td colspan=\"5\">350\u00b11<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Insulation resistance @50VDC<\/td>\n<td>M\u03a9<\/td>\n<td colspan=\"5\">\u2265 5000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Breakdown voltage<\/td>\n<td>V AC<\/td>\n<td colspan=\"5\">&gt; 500<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Material<\/td>\n<td>Spring element<\/td>\n<td><\/td>\n<td colspan=\"5\">Nickel plated alloy steel<\/td>\n<\/tr>\n<tr>\n<td>Enclosure<\/td>\n<td><\/td>\n<td colspan=\"5\">None<\/td>\n<\/tr>\n<tr>\n<td>Cable entry fitting<\/td>\n<td><\/td>\n<td colspan=\"5\">304<\/td>\n<\/tr>\n<tr>\n<td>Cable<\/td>\n<td><\/td>\n<td colspan=\"5\">PVC<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Protection<\/td>\n<td>Type<\/td>\n<td><\/td>\n<td colspan=\"5\">Potted<\/td>\n<\/tr>\n<tr>\n<td>IP rating<\/td>\n<td><\/td>\n<td colspan=\"5\">IP67<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Load limit<\/td>\n<td>Safe<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"5\">150<\/td>\n<\/tr>\n<tr>\n<td>Ultimate<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"5\">300<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Safe dynamic load<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"5\">70<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Fatigue life<\/td>\n<td>cycles @R.C.<\/td>\n<td colspan=\"5\">&gt;1.000.000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Direction of loading<\/td>\n<td><\/td>\n<td colspan=\"5\">Compression<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Weight, nominal<\/td>\n<td>kg (lb)<\/td>\n<td colspan=\"4\">4.15 (9.2)<\/td>\n<td>5.4 (12)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Cable<\/td>\n<td>Length<\/td>\n<td>m (ft)<\/td>\n<td colspan=\"5\">5 (16.6)<\/td>\n<\/tr>\n<tr>\n<td>Diameter<\/td>\n<td>mm (in)<\/td>\n<td colspan=\"5\">5.8 (0.23)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Barometric pressure effect on zero load output<\/td>\n<td>kg\/kPa (lb\/in.Hg)<\/td>\n<td colspan=\"5\">None<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Safe side load<\/td>\n<td>%R.C.<\/td>\n<td colspan=\"5\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Overload protection<\/td>\n<td><\/td>\n<td colspan=\"5\">No<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Mounting screw<\/td>\n<td>Grade<\/td>\n<td><\/td>\n<td colspan=\"5\">12.9<\/td>\n<\/tr>\n<tr>\n<td>Size\/thread<\/td>\n<td>mm<\/td>\n<td colspan=\"4\">M14<\/td>\n<td>M16<\/td>\n<\/tr>\n<tr>\n<td>Engaged length<\/td>\n<td>mm (in)<\/td>\n<td colspan=\"5\">25 1)<\/td>\n<\/tr>\n<tr>\n<td>Torque, nominal<\/td>\n<td>N.m (ft-lb)<\/td>\n<td colspan=\"4\">98 (72)<\/td>\n<td>196 (143)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Max. platter size<\/td>\n<td>cm x cm (in x in)<\/td>\n<td colspan=\"4\">80&#215;80 (3.15&#215;3.15)<\/td>\n<td>100&#215;100 (3.93&#215;3.93)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Off center load error @33%R.C.<\/td>\n<td>%A.L.\/cm (..\/in)<\/td>\n<td colspan=\"4\">0.0045 (0.011)<\/td>\n<td>0.0035 (0.0087)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>1) Error due to the combined effect of non-linearity and hysteresis<br \/>\n2) Typical values only. The sum of errors due to combined error and temperature effect on sensitivity comply with the requirements of OIML R60 and NIST HB44.<br \/>\n3) A.L. = Applied Load<br \/>\n4) See certificate for complete information<\/p>\n<p><strong>IL Load Cell Dimensional Drawings mm [inch]<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-285587 size-full\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/IL_3.png\" alt=\"\" width=\"1356\" height=\"855\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/IL_3.png 1356w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/IL_3-634x400.png 634w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/IL_3-1269x800.png 1269w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/IL_3-768x484.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/IL_3-600x378.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/IL_3-64x40.png 64w\" sizes=\"(max-width: 1356px) 100vw, 1356px\" \/><\/p>\n<table width=\"100%\">\n<thead>\n<tr>\n<th rowspan=\"2\">Capacity<\/th>\n<th colspan=\"9\">Dimensions and locations<\/th>\n<\/tr>\n<tr>\n<th>D<\/th>\n<th>H1<\/th>\n<th>H2<\/th>\n<th>L1<\/th>\n<th>L2<\/th>\n<th>L3<\/th>\n<th>W1<\/th>\n<th>W2<\/th>\n<th>W3<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>150kg\u20131000kg[330\u20132204lb]<\/td>\n<td>M14<\/td>\n<td>46[1.81]<\/td>\n<td>72[2.83]<\/td>\n<td>15 0[5.91]<\/td>\n<td>85[3.35]<\/td>\n<td>100[3.94]<\/td>\n<td>38[1.50]<\/td>\n<td>64[2.52]<\/td>\n<td>8[0.31]<\/td>\n<\/tr>\n<tr>\n<td>2000kg[4409lb]<\/td>\n<td>M16<\/td>\n<td>55[2.17]<\/td>\n<td>80[3.15]<\/td>\n<td>150[5.91]<\/td>\n<td>85[3.35]<\/td>\n<td>100[3.94]<\/td>\n<td>42[1.65]<\/td>\n<td>72[2.83]<\/td>\n<td>8[0.31]<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>IL Load Cell Order Information<\/strong><\/p>\n<table width=\"100%\">\n<thead>\n<tr>\n<th>\nDescription<\/th>\n<th>\nItem No.<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\nLoad cell, model no. IL-150kg-5M<\/td>\n<td>\n71209638<\/td>\n<\/tr>\n<tr>\n<td>\nLoad cell, model no. IL-250kg-5M<\/td>\n<td>\n71209639<\/td>\n<\/tr>\n<tr>\n<td>\nLoad cell, model no. IL-500kg-5M<\/td>\n<td>\n71209635<\/td>\n<\/tr>\n<tr>\n<td>\nLoad cell, modelno.IL-1000kg-5M<\/td>\n<td>\n71209640<\/td>\n<\/tr>\n<tr>\n<td>\nLoad cell, modelno.IL-2000kg-5M<\/td>\n<td>\n71209780<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>IL Load Cell Cable Colours<\/strong><\/p>\n<table width=\"100\">\n<thead>\n<tr>\n<th><strong>Colour<\/strong><\/th>\n<th><strong>Function<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Green<\/td>\n<td>+ Excitation<\/td>\n<\/tr>\n<tr>\n<td>Black<\/td>\n<td>\u2013 Excitation<\/td>\n<\/tr>\n<tr>\n<td>White<\/td>\n<td>+ Signal<\/td>\n<\/tr>\n<tr>\n<td>Red<\/td>\n<td>\u2013 Signal<\/td>\n<\/tr>\n<tr>\n<td>Yellow<\/td>\n<td>+ Sense<\/td>\n<\/tr>\n<tr>\n<td>Blue<\/td>\n<td>\u2013 Sense<\/td>\n<\/tr>\n<tr>\n<td>Yellow (Long)<\/td>\n<td>Shield<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>\u2022 OIML R60 C3 approved<br \/>\n\u2022 Off-center load compensated (R76)<br \/>\n\u2022 Up to 1000&#215;1000 mm platform size<br \/>\n\u2022 IP67 protection class<br \/>\n\u2022 Nickel plated steel<\/p>\n","protected":false},"featured_media":285584,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5114],"product_cat":[3385],"product_tag":[5395,5310,5069,5382],"class_list":{"0":"post-285582","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-mettler-toledo","7":"product_cat-single-point-en","8":"product_tag-il-en","9":"product_tag-mettler-toredo-en","10":"product_tag-single-point-load-cell-en2","11":"product_tag-single-point-load-cell-2-en","13":"first","14":"instock","15":"taxable","16":"shipping-taxable","17":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/285582","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=285582"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/285584"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=285582"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=285582"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=285582"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=285582"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}