{"id":285776,"date":"2025-11-26T14:03:59","date_gmt":"2025-11-26T05:03:59","guid":{"rendered":"https:\/\/casscale.net\/?post_type=product&#038;p=285776"},"modified":"2026-03-18T11:38:09","modified_gmt":"2026-03-18T02:38:09","slug":"aep-transducers-f1-bending-beam-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/aep-transducers-f1-bending-beam-load-cell\/","title":{"rendered":"AEP transducers \/ F1 \/ Bending Beam Load Cell"},"content":{"rendered":"<h4><strong>BENDING<\/strong>\u00a0<strong>BAEM<\/strong>\u00a0load cell for the measurement of static and dynamic loads.<\/h4>\n<p>Nominal Load from\u00a0<strong>2,5 kg<\/strong>\u00a0to\u00a0<strong>200 kg<\/strong><br \/>\nClass (OIML R60) C2 and C3<br \/>\nCombined Error: 0,020%<br \/>\nOutput: 2mV\/V<\/p>\n<div id='gallery-1' class='gallery galleryid-285776 gallery-columns-2 gallery-size-full'><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/casscale.net\/en\/?attachment_id=285714'><img decoding=\"async\" width=\"150\" height=\"70\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/label-eac-2.jpg\" class=\"attachment-full size-full\" alt=\"\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/label-eac-2.jpg 150w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/label-eac-2-64x30.jpg 64w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/casscale.net\/en\/?attachment_id=285730'><img decoding=\"async\" width=\"300\" height=\"90\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/ATEX-300x90.jpg\" class=\"attachment-full size-full\" alt=\"\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/ATEX-300x90.jpg 300w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/ATEX-300x90-295x90.jpg 295w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/ATEX-300x90-64x19.jpg 64w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a>\n\t\t\t<\/div><\/figure>\n\t\t<\/div>\n\n<p>&nbsp;<\/p>\n<p><strong> Dimensions [mm]<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-285779\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/F1_2.png\" alt=\"\" width=\"746\" height=\"557\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/F1_2.png 746w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/F1_2-536x400.png 536w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/F1_2-600x448.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/F1_2-64x48.png 64w\" sizes=\"(max-width: 746px) 100vw, 746px\" \/><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<tbody>\n<tr>\n<th>CODE (C2)<\/th>\n<th>CODE (C3)<\/th>\n<th>LOAD<\/th>\n<\/tr>\n<tr>\n<td>CF12K5C25<\/td>\n<td>\/<\/td>\n<td>2.5 kg<\/td>\n<\/tr>\n<tr>\n<td>CF15KC25<\/td>\n<td>\/<\/td>\n<td>5 kg<\/td>\n<\/tr>\n<tr>\n<td>CF110KC25<\/td>\n<td>CF110KC35<\/td>\n<td>10 kg<\/td>\n<\/tr>\n<tr>\n<td>CF125KC25<\/td>\n<td>CF125KC35<\/td>\n<td>25 kg<\/td>\n<\/tr>\n<tr>\n<td>CF150KC25<\/td>\n<td>CF150KC35<\/td>\n<td>50 kg<\/td>\n<\/tr>\n<tr>\n<td>CF1100KC25<\/td>\n<td>CF1100KC35<\/td>\n<td>100 kg<\/td>\n<\/tr>\n<tr>\n<td>CF1200KC25<\/td>\n<td>CF1200KC35<\/td>\n<td>200 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Technical Data<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td><em>ACCURACY CLASS: <strong>OIML R60<\/strong><\/em><\/td>\n<td><strong>C2<\/strong><\/td>\n<td><strong>C3<\/strong><\/td>\n<\/tr>\n<tr>\n<td><em>LEGAL DIVISIONS<\/em><\/td>\n<td>2000<\/td>\n<td>3000<\/td>\n<\/tr>\n<tr>\n<td><em>NOMINAL LOAD (E<em>max<\/em>)<\/em><\/td>\n<td>2.5 &#8211; 5 &#8211; 10 kg<br \/>\n25 &#8211; 50 kg<br \/>\n100 &#8211; 200 kg<\/td>\n<td>10 kg<br \/>\n25 &#8211; 50 kg<br \/>\n100 &#8211; 200 kg<\/td>\n<\/tr>\n<tr>\n<td><em>MIN. VERIFICATION INTERVAL (V<em>min<\/em>)<\/em><\/td>\n<td colspan=\"2\">Emax \/ 10000<\/td>\n<\/tr>\n<tr>\n<td><em>COMBINED ERROR<\/em><\/td>\n<td>\u00b1 0.026 %<\/td>\n<td>\u00b1 0.020 %<\/td>\n<\/tr>\n<tr>\n<td><em>NON-REPEATABILITY<\/em><\/td>\n<td>\u00b1 0.012 %<\/td>\n<td>\u00b1 0.010 %<\/td>\n<\/tr>\n<tr>\n<td><em>ZERO RETURN over 30 min.<\/em><\/td>\n<td>\u00b1 0.025 %<\/td>\n<td>\u00b1 0.015 %<\/td>\n<\/tr>\n<tr>\n<td><em>CREEP to nominal load:<\/em><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><em>a) over 30 min.<\/em><\/td>\n<td>\u00b1 0.026 %<\/td>\n<td>\u00b1 0.012 %<\/td>\n<\/tr>\n<tr>\n<td><em>b) over 20 and 30 min.<\/em><\/td>\n<td>\u00b1 0.010 %<\/td>\n<td>\u00b1 0.009 %<\/td>\n<\/tr>\n<tr>\n<td><em>TEMPERATURE EFFECT (10 \u00b0C)<\/em><br \/>\n<em>a) on zero<\/em><br \/>\n<em>b) on sensitivity<\/em><\/td>\n<td>\u00b1 0.025 %<br \/>\n\u00b1 0.008 %<\/td>\n<td>\u00b1 0.012 %<br \/>\n\u00b1 0.008 %<\/td>\n<\/tr>\n<tr>\n<td><em>NOMINAL SENSITIVITY<\/em><br \/>\n<em>SENSITIVITY TOLERANCE<\/em><\/td>\n<td colspan=\"2\">2 mV\/V<br \/>\n\u00b1 0.1 %<\/td>\n<\/tr>\n<tr>\n<td><em>INPUT RESISTANCE<\/em><\/td>\n<td colspan=\"2\">420 \u00b1 20 \u03a9<\/td>\n<\/tr>\n<tr>\n<td><em>OUTPUT RESISTANCE<\/em><\/td>\n<td colspan=\"2\">350 \u00b1 2 \u03a9<\/td>\n<\/tr>\n<tr>\n<td><em>INSULATION RESISTANCE<\/em><\/td>\n<td colspan=\"2\">&gt; 5 G\u03a9<\/td>\n<\/tr>\n<tr>\n<td><em>ZERO BALANCE<\/em><\/td>\n<td colspan=\"2\">\u00b1 1 %<\/td>\n<\/tr>\n<tr>\n<td><em>RECOMMENDED SUPPLY VOLTAGE<\/em><\/td>\n<td colspan=\"2\">10 V<\/td>\n<\/tr>\n<tr>\n<td><em>NOMINAL SUPPLY VOLTAGE<\/em><\/td>\n<td colspan=\"2\">1 &#8211; 15 V<\/td>\n<\/tr>\n<tr>\n<td><em>MAXIMUM SUPPLY VOLTAGE<\/em><\/td>\n<td colspan=\"2\">18 V<\/td>\n<\/tr>\n<tr>\n<td><em>MECHANICAL LIMIT VALUES<\/em><\/td>\n<td colspan=\"2\"><\/td>\n<\/tr>\n<tr>\n<td><em>REFERRED TO NOMINAL LOAD:<\/em><\/td>\n<td colspan=\"2\"><\/td>\n<\/tr>\n<tr>\n<td><em>a) minimum load<\/em><\/td>\n<td colspan=\"2\">0 %<\/td>\n<\/tr>\n<tr>\n<td><em>b) service load<\/em><\/td>\n<td colspan=\"2\">120 %<\/td>\n<\/tr>\n<tr>\n<td><em>c) max permissible load<\/em><\/td>\n<td colspan=\"2\">150 %<\/td>\n<\/tr>\n<tr>\n<td><em>d) breaking load<\/em><\/td>\n<td colspan=\"2\">&gt; 300 %<\/td>\n<\/tr>\n<tr>\n<td><em>e) max transverse load<\/em><\/td>\n<td colspan=\"2\">200 %<\/td>\n<\/tr>\n<tr>\n<td><em>f) max permissible dynamic load<\/em><br \/>\n<em>DISPLACEMENT AT NOMINAL LOAD<\/em><\/td>\n<td colspan=\"2\">75 %<br \/>\n~ 0.4 mm<\/td>\n<\/tr>\n<tr>\n<td><em>REFERENCE TEMPERATURE<\/em><\/td>\n<td colspan=\"2\">+23 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td><em>TEMPERATURE NOMINAL RANGE<\/em><\/td>\n<td colspan=\"2\">-10 \/ +40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td><em>SERVICE TEMPERATURE<\/em><\/td>\n<td colspan=\"2\">-20 \/ +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td><em>STORAGE TEMPERATURE<\/em><\/td>\n<td colspan=\"2\">-20 \/ +80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td><em>WEIGHT<\/em><\/td>\n<td colspan=\"2\">~ 0.62 kg<\/td>\n<\/tr>\n<tr>\n<td><em>PROTECTION CLASS<\/em> (EN 60529)<br \/>\n<em>EXECUTION MATERIAL<\/em><br \/>\n<em>CABLE LENGTH<\/em><\/td>\n<td colspan=\"2\">IP67<br \/>\nStainless Steel<br \/>\n5 m<\/td>\n<\/tr>\n<tr>\n<td><em>FIXING SCREWS:<\/em><\/td>\n<td colspan=\"2\"><\/td>\n<\/tr>\n<tr>\n<td><em>a) diameter<\/em><\/td>\n<td colspan=\"2\">M8<\/td>\n<\/tr>\n<tr>\n<td><em>b) resistance class<\/em><\/td>\n<td colspan=\"2\">12.9<\/td>\n<\/tr>\n<tr>\n<td><em>c) tightening torque<\/em><\/td>\n<td colspan=\"2\">20 Nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A<em>cceleration of g<\/em>ravity <em>g=9.80434 m\/s2<\/em><\/p>\n<p><strong>Electrical Connections<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-285723\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TCA_2.png\" alt=\"\" width=\"1036\" height=\"463\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TCA_2.png 1036w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TCA_2-800x358.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TCA_2-768x343.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TCA_2-600x268.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TCA_2-64x29.png 64w\" sizes=\"(max-width: 1036px) 100vw, 1036px\" \/><\/p>\n<p><em>Connected to the body of the load cell.<br \/>\n<\/em><\/p>\n<p><em>PVC 105\u00b0C shielded cable, \u00d8 5.2mm with 4 tinned \u00d80.35mm2 conductors.<\/em><\/p>\n<p><em>\u00a0<\/em><\/p>\n<p><strong><em>Shield <\/em>c<em>onnected to the body of the load cell.<\/em><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<div class=\"wpb_text_column wpb_content_element \">\n<div class=\"wpb_wrapper\">\n<p>Load cell suitable to work in hostile environments.<br \/>\nHigh mechanical resistance.<br \/>\nCompletely made of stainless steel.<br \/>\nCompletely LASER welded.<br \/>\nDegree of protection IP67.<br \/>\nLong term stability.<\/p>\n<p>On request\u00a0<strong>ATEX<\/strong>\u00a0certificate\u00a0(Zones 1 and 21) GAS and DUST<\/p>\n<\/div>\n<\/div>\n","protected":false},"featured_media":285778,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5397],"product_cat":[3383,3382],"product_tag":[4493],"class_list":{"0":"post-285776","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-aep-transducers","7":"product_cat-beam-type-load-cell","8":"product_cat-bending-shear-beam-en","9":"product_tag-bending-beam-loadcell","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>AEP transducers \/ F1 \/ Bending Beam Load Cell - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"Load cell suitable to work in hostile environments. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability.  On request\u00a0ATEX\u00a0certificate\u00a0(Zones 1 and 21) GAS and DUST\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/product\/aep-transducers-f1-bending-beam-load-cell\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"AEP transducers \/ F1 \/ Bending Beam Load Cell\" \/>\n<meta property=\"og:description\" content=\"Load cell suitable to work in hostile environments. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability.  On request\u00a0ATEX\u00a0certificate\u00a0(Zones 1 and 21) GAS and DUST\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/product\/aep-transducers-f1-bending-beam-load-cell\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-18T02:38:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/f1-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-f1-bending-beam-load-cell\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-f1-bending-beam-load-cell\\\/\",\"name\":\"AEP transducers \\\/ F1 \\\/ Bending Beam Load Cell - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-f1-bending-beam-load-cell\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-f1-bending-beam-load-cell\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/f1-1.webp\",\"datePublished\":\"2025-11-26T05:03:59+00:00\",\"dateModified\":\"2026-03-18T02:38:09+00:00\",\"description\":\"Load cell suitable to work in hostile environments. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability. On request\u00a0ATEX\u00a0certificate\u00a0(Zones 1 and 21) GAS and DUST\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-f1-bending-beam-load-cell\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-f1-bending-beam-load-cell\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-f1-bending-beam-load-cell\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/f1-1.webp\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/f1-1.webp\",\"width\":600,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-f1-bending-beam-load-cell\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"AEP transducers \\\/ F1 \\\/ Bending Beam Load Cell\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/product\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"AEP transducers \/ F1 \/ Bending Beam Load Cell - CAS Scale Korea Co., Ltd.","description":"Load cell suitable to work in hostile environments. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability.  On request\u00a0ATEX\u00a0certificate\u00a0(Zones 1 and 21) GAS and DUST","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/product\/aep-transducers-f1-bending-beam-load-cell\/","og_locale":"en_US","og_type":"article","og_title":"AEP transducers \/ F1 \/ Bending Beam Load Cell","og_description":"Load cell suitable to work in hostile environments. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability.  On request\u00a0ATEX\u00a0certificate\u00a0(Zones 1 and 21) GAS and DUST","og_url":"https:\/\/casscale.net\/en\/product\/aep-transducers-f1-bending-beam-load-cell\/","og_site_name":"CAS Scale Korea Co., Ltd.","article_modified_time":"2026-03-18T02:38:09+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/f1-1.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-f1-bending-beam-load-cell\/","url":"https:\/\/casscale.net\/en\/product\/aep-transducers-f1-bending-beam-load-cell\/","name":"AEP transducers \/ F1 \/ Bending Beam Load Cell - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-f1-bending-beam-load-cell\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-f1-bending-beam-load-cell\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/f1-1.webp","datePublished":"2025-11-26T05:03:59+00:00","dateModified":"2026-03-18T02:38:09+00:00","description":"Load cell suitable to work in hostile environments. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability. On request\u00a0ATEX\u00a0certificate\u00a0(Zones 1 and 21) GAS and DUST","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-f1-bending-beam-load-cell\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/product\/aep-transducers-f1-bending-beam-load-cell\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-f1-bending-beam-load-cell\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/f1-1.webp","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/f1-1.webp","width":600,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-f1-bending-beam-load-cell\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"AEP transducers \/ F1 \/ Bending Beam Load Cell"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/product\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/285776","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=285776"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/285778"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=285776"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=285776"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=285776"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=285776"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}