{"id":285874,"date":"2025-11-27T09:30:19","date_gmt":"2025-11-27T00:30:19","guid":{"rendered":"https:\/\/casscale.net\/?post_type=product&#038;p=285874"},"modified":"2026-03-18T11:37:32","modified_gmt":"2026-03-18T02:37:32","slug":"aep-transducers-star-f-professional-hand-held-indicator","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/aep-transducers-star-f-professional-hand-held-indicator\/","title":{"rendered":"AEP transducers \/ STAR-F \/ Professional Hand Held Indicator"},"content":{"rendered":"<h4>Pressure Force Torque Displacement in your HANDS<\/h4>\n<p>Professional ergonomic indicator extremely versatile and easy to be used for measurement of FORCE, WEIGHT, PRESSURE (gas), VACUUM, TORQUE and DISPLACEMENT. It is possible to\u00a0<strong>integrate inside<\/strong>\u00a0a\u00a0<strong>FORCE<\/strong>\u00a0sensor from\u00a0<strong>10 N<\/strong>\u00a0to\u00a0<strong>5 kN<\/strong>\u00a0or a pressure sensor (relative, absolute or differential up to max. 5bar) while from the external input it is possible to connect strain gauges sensors with output in mV\/V such as: load cells, force transducers, pressure transducers, torque and displacement transducers. AUTOMATIC recognition of FORCE, WEIGHT, VACUUM, PRESSURE, TORQUE and DISPLACEMENT external transducers (max. 7) LCD graph DISPLAY with 3 levels of backlighting to adapt itself to any conditions of external brightness and with the possibility of rotating the \u00a0visualization of 180\u00b0. DIGITAL CALIBRATIONS protected by Password with full scale programming or with the \u201cLINEARIZATION by points\u201d of transducers, for every transducer it is possible to separately calibrate both the positive and the negative field. (Example: Tension and Compression) DATALOGGER allows to memorize measurements and to keep them in the internal memory even in case of instrument switching off. (max. 130.000 recordings)<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-8975 ls-is-cached lazyloaded\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/label-eac-2.jpg\" alt=\"\" width=\"150\" height=\"70\" data-src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/label-eac-2.jpg\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>Typical Applications:<br \/>\n\u2713 Calibration of materials test machines, test benches, pressure tester, pressure switch etc.<br \/>\n\u2713 Quality controls in the production lines, calibration and test laboratories.<br \/>\n\u2713 Compression and tension tests on springs.<br \/>\n\u2713 Tests of frictions, cable terminal tearing, rivets etc.<br \/>\n\u2713 Test of lockup on both packing and protection devices.<br \/>\n\u2713 Test on welding of electronic components.<br \/>\n\u2713 Test of opening and closing of both manual and automatic doors.<br \/>\n\u2713 Test of the handling of both manual and automatic loads.<br \/>\n\u2713 Test on filters, loss and vacuum tests, analysis of pressures variation in the time.<br \/>\n\u2713 Wireless monitoring of hanging loads, mobile weighing.<br \/>\n\u2713 Environmental pressure monitoring. (Barometer)<br \/>\n\u2713 Calibration of: release and direct reading torque keys, screw drivers.<br \/>\n\u2713 Monitoring of cracks through displacement transducers in the building industry.<\/p>\n<p><strong><em>Dimensions (mm):<\/em><\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-285893\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_6.jpg\" alt=\"\" width=\"491\" height=\"243\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_6.jpg 491w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_6-64x32.jpg 64w\" sizes=\"(max-width: 491px) 100vw, 491px\" \/><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-285895\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_6.png\" alt=\"\" width=\"898\" height=\"633\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_6.png 898w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_6-567x400.png 567w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_6-768x541.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_6-600x423.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_6-64x45.png 64w\" sizes=\"(max-width: 898px) 100vw, 898px\" \/><\/p>\n<p><strong>Available combinations:<\/strong><\/p>\n<p>Star-F with internal sensor to measure FORCE and WEIGHT in compression and tension in ranges from 10 N (1 kg) up to 5 kN (500 kg)<br \/>\nWith external sensors (1) such as load cells or force transducers with standardized ranges up to 5 MN (500 t).<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-285881\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_2.png\" alt=\"\" width=\"544\" height=\"75\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_2.png 544w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_2-64x9.png 64w\" sizes=\"(max-width: 544px) 100vw, 544px\" \/><\/p>\n<p><strong>KIT of accessories <\/strong>to perform COMPRESSION and TENSION tests on materials.<\/p>\n<p>(A) Hook for tension tests.<br \/>\n(B) Short threaded extension.<br \/>\n(C) Long threaded extension.<br \/>\n(D) Tapered tip for compression testing.<br \/>\n(E) Toothed tip for compression testing.<br \/>\n(F) Chisel tip for compression testing.<br \/>\n(G) Flat tip for compression testing.<br \/>\n(H) Threaded compass.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-285885\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/DNA2_4.png\" alt=\"\" width=\"762\" height=\"453\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/DNA2_4.png 762w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/DNA2_4-673x400.png 673w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/DNA2_4-600x357.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/DNA2_4-64x38.png 64w\" sizes=\"(max-width: 762px) 100vw, 762px\" \/><\/p>\n<p>Star-P with internal sensor to measure the VACUUM, a relative, absolute or differential PRESSURE in gas (NO liquids), with ranges from 100 mbar up to 5 bar (1.5 a 70 psi).<br \/>\nWith external sensors (1) such as TP16 or TP1 models to measure higher pressures with standardized ranges up to 2000 bar (29000 psi) suitable for both gas and liquids.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-285887\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_3.png\" alt=\"\" width=\"712\" height=\"415\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_3.png 1042w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_3-687x400.png 687w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_3-768x447.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_3-600x350.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_3-64x37.png 64w\" sizes=\"(max-width: 712px) 100vw, 712px\" \/><\/p>\n<p><strong><em>Star <\/em><\/strong>with <strong>external<\/strong><sup>(1)<\/sup> sensors such as TRX, TRS, RT2, uTOR models to measure static or dynamic <strong>TORQUES <\/strong>with standardized ranges from 1 up to 5000 Nm.<br \/>\nPossibility of recording continuous <strong>PEAKS <\/strong>in clockwise and anticlockwise direction at high speed, 4.8 kHz.<br \/>\nPossibility of recording <strong>1\u00b0 PEAK <\/strong>with programmable threshold to test torque keys.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-285889\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_4.png\" alt=\"\" width=\"2053\" height=\"618\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_4.png 2053w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_4-800x241.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_4-1400x421.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_4-768x231.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_4-1536x462.png 1536w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_4-2048x616.png 2048w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_4-600x181.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_4-64x19.png 64w\" sizes=\"(max-width: 2053px) 100vw, 2053px\" \/><\/p>\n<p>With <strong>external<\/strong><sup>(1)<\/sup> sensors such us LDT model to measure the <strong>DISPLACEMENT <\/strong>with standardized ranges from 5 up to 200 mm.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-285891\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_5.png\" alt=\"\" width=\"762\" height=\"470\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_5.png 1028w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_5-649x400.png 649w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_5-768x474.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_5-600x370.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/STAR-F_5-64x39.png 64w\" sizes=\"(max-width: 762px) 100vw, 762px\" \/><\/p>\n<p>(1) <strong><em>Star <\/em><\/strong>automatically recognizes a max. number of 7 transducers alternatively connected, by <strong>Auto Configuring <\/strong>itself with the dedicated parameters (Measurement unit, Filter, Resolution). It is possible to connect different sensors to perform measurements of FORCE, WEIGHT, PRESSURE, TORQUE and DISPLACEMENT.<\/p>\n<p><strong><span lang=\"EN-US\">Main <span style=\"letter-spacing: -.1pt;\">characteristics:<\/span><\/span><\/strong><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<tbody>\n<tr>\n<td><strong>PRESSURE internal sensor ACCURACY:<\/strong> 0.10% F.S. (ON REQUEST 0.05% F.S.)<br \/>\n<strong>FORCE internal sensor ACCURACY:<\/strong> 0.05% F.S. \u00a0 External channel ACCURACY: 0.01% F.S.<br \/>\nREFERENCE temperature 23\u00b0C, Service temperature from 0 to +50\u00b0C<br \/>\nTemperature effect (10\u00b0C): on zero \u00b10.01%, on full scale \u00b10.01%<\/td>\n<\/tr>\n<tr>\n<td><strong>External INPUT<\/strong> signal 2mV\/V (350 or 700\u03a9, 4 wires system) 5Vdc power supply<br \/>\nStandard resolution \u00b150,000 divisions at 2mV\/V<\/td>\n<\/tr>\n<tr>\n<td>HIGH RESOLUTION (128\u00d764 dots) LCD <strong>DISPLAY<\/strong> with 3 backlight levels and 180\u00b0 rotation.<\/td>\n<\/tr>\n<tr>\n<td><strong>AUTOMATIC recognition<\/strong> of FORCE, WEIGHT, VACUUM, PRESSURE, TORQUE and DISPLACEMENT<br \/>\nExternal transducers (max. 7)<\/td>\n<\/tr>\n<tr>\n<td>Programmable <strong>MEASUREMENT UNITS<\/strong>:<br \/>\n<strong>FORCE \/ WEIGHT:<\/strong> kg, g, t, N, daN, kN, MN, lb, klb<br \/>\n<strong>PRESSURE:<\/strong> bar, mbar, psi, MPa, kPa, Pa, mH2O, inH2O, kg\/cm\u00b2, mmHg, cmHg, inHg, atm<br \/>\n<strong>TORQUE:<\/strong> Nm, Nmm, kgm, kNm, in.lbf, ft.lbf, gcm, kgmm<br \/>\n<strong>LENGTH:<\/strong> mm, inch<\/td>\n<\/tr>\n<tr>\n<td><strong>DIGITAL CALIBRATIONS<\/strong> protected by password (full scale or point linearization).<br \/>\nPositive and negative field can be calibrated separately (e.g., tension\/compression).<\/td>\n<\/tr>\n<tr>\n<td><strong>DATALOGGER<\/strong> (130,000 records) with Automatic mode (0.1 sec \u2013 24 hr) or Manual REC mode.<br \/>\nData viewable on display or downloadable via Quick Analyzer (graphs, Excel, reports).<\/td>\n<\/tr>\n<tr>\n<td>Programmable <strong>RESOLUTION<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Digital <strong>FILTER<\/strong> and <strong>CONVERSIONS per second<\/strong> (5 to 4800) programmable<\/td>\n<\/tr>\n<tr>\n<td><strong>ZERO<\/strong> function resets measurement instantly.<br \/>\n<strong>HOLD<\/strong> temporarily freezes the measurement.<\/td>\n<\/tr>\n<tr>\n<td><strong>PEAK<\/strong> function (positive and negative)<\/td>\n<\/tr>\n<tr>\n<td>Li-Ion battery \u2014 24 hr autonomy (with backlight).<br \/>\nIn DATALOGGER (5 min interval): approx. 100 hr operation.<br \/>\n<strong>AUTO POWER OFF<\/strong> programmable (1\u201399 min).<\/td>\n<\/tr>\n<tr>\n<td><strong>CLOCK<\/strong> (hours\/minutes) and internal <strong>CALENDAR<\/strong> (day\/month)<\/td>\n<\/tr>\n<tr>\n<td>Serial communication via <strong>USB<\/strong> (max. 20 data\/sec).<br \/>\n<strong>WIRELESS<\/strong> transmission ON REQUEST (max. 10 data\/sec).<\/td>\n<\/tr>\n<tr>\n<td>Protection grade (EN 60529): <strong>IP40<\/strong><br \/>\nPainted <strong>ALUMINIUM<\/strong> case with yellow silicone <strong>COVER<\/strong><br \/>\n<strong>WEIGHT:<\/strong> ~0.7 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>STAR can be manufactured on REQUEST equipped with the WIRELESS transmission, which allows to transmit the data directly to a PC and to TABLET or a PLC.<br \/>\nBy using WinWIMOD software it is possible to create a NETWORK with up to 32 units, the net can consist of both STAR instruments and sensors interfaced with WIMOD.<\/p>\n<p><strong>Purchase codes:<\/strong><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<tbody>\n<tr>\n<td><strong>STAR<\/strong><\/td>\n<td colspan=\"2\"><strong>INTERNAL sensor<\/strong><\/td>\n<td><strong>WIRELESS<\/strong><br \/>\ntransmission<\/td>\n<\/tr>\n<p><!-- ABSOLUTE PRESSURE --><\/p>\n<tr>\n<td rowspan=\"4\"><strong>ABSOLUTE PRESSURE<\/strong><br \/>\n<strong>(Barometer)<\/strong><\/td>\n<td>500 mbar<\/td>\n<td><strong>500MBARA<\/strong><\/td>\n<td><strong>W<\/strong><\/td>\n<\/tr>\n<tr>\n<td>1 bar<\/td>\n<td><strong>1BARA<\/strong><\/td>\n<td rowspan=\"27\"><\/td>\n<\/tr>\n<tr>\n<td>2.5 bar<\/td>\n<td><strong>2.5BARA<\/strong><\/td>\n<\/tr>\n<tr>\n<td>5 bar<\/td>\n<td><strong>5BARA<\/strong><\/td>\n<\/tr>\n<p><!-- RELATIVE PRESSURE --><\/p>\n<tr>\n<td rowspan=\"5\"><strong>RELATIVE PRESSURE<\/strong><\/td>\n<td>100 mbar<\/td>\n<td><strong>100MBAR<\/strong><\/td>\n<\/tr>\n<tr>\n<td>500 mbar<\/td>\n<td><strong>500MBAR<\/strong><\/td>\n<\/tr>\n<tr>\n<td>1 bar<\/td>\n<td><strong>1BAR<\/strong><\/td>\n<\/tr>\n<tr>\n<td>2.5 bar<\/td>\n<td><strong>2.5BAR<\/strong><\/td>\n<\/tr>\n<tr>\n<td>5 bar<\/td>\n<td><strong>5BAR<\/strong><\/td>\n<\/tr>\n<p><!-- RELATIVE PRESSURE VACUUM --><\/p>\n<tr>\n<td rowspan=\"5\"><strong>RELATIVE PRESSURE VACUUM<\/strong><\/td>\n<td>100 mbar<\/td>\n<td><strong>100MBARV<\/strong><\/td>\n<\/tr>\n<tr>\n<td>500 mbar<\/td>\n<td><strong>500MBARV<\/strong><\/td>\n<\/tr>\n<tr>\n<td>1 bar<\/td>\n<td><strong>1BARV<\/strong><\/td>\n<\/tr>\n<tr>\n<td>2.5 bar<\/td>\n<td><strong>2.5BARV<\/strong><\/td>\n<\/tr>\n<tr>\n<td>5 bar<\/td>\n<td><strong>5BARV<\/strong><\/td>\n<\/tr>\n<p><!-- DIFFERENTIAL PRESSURE --><\/p>\n<tr>\n<td rowspan=\"5\"><strong>DIFFERENTIAL PRESSURE<\/strong><\/td>\n<td>100 mbar<\/td>\n<td><strong>100MBARD<\/strong><\/td>\n<\/tr>\n<tr>\n<td>500 mbar<\/td>\n<td><strong>500MBARD<\/strong><\/td>\n<\/tr>\n<tr>\n<td>1 bar<\/td>\n<td><strong>1BARD<\/strong><\/td>\n<\/tr>\n<tr>\n<td>2.5 bar<\/td>\n<td><strong>2.5BARD<\/strong><\/td>\n<\/tr>\n<tr>\n<td>5 bar<\/td>\n<td><strong>5BARD<\/strong><\/td>\n<\/tr>\n<p><!-- FORCE --><\/p>\n<tr>\n<td rowspan=\"9\"><strong>FORCE<\/strong><\/td>\n<td>10 N<\/td>\n<td><strong>10N<\/strong><\/td>\n<\/tr>\n<tr>\n<td>25 N<\/td>\n<td><strong>25N<\/strong><\/td>\n<\/tr>\n<tr>\n<td>50 N<\/td>\n<td><strong>50N<\/strong><\/td>\n<\/tr>\n<tr>\n<td>100 N<\/td>\n<td><strong>100N<\/strong><\/td>\n<\/tr>\n<tr>\n<td>250 N<\/td>\n<td><strong>250N<\/strong><\/td>\n<\/tr>\n<tr>\n<td>500 N<\/td>\n<td><strong>500N<\/strong><\/td>\n<\/tr>\n<tr>\n<td>1000 N<\/td>\n<td><strong>1KN<\/strong><\/td>\n<\/tr>\n<tr>\n<td>3000 N<\/td>\n<td><strong>3KN<\/strong><\/td>\n<\/tr>\n<tr>\n<td>5000 N<\/td>\n<td><strong>5KN<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><em>Examples:<\/em><\/strong><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<tbody>\n<tr>\n<td><strong>STAR<\/strong><\/td>\n<td>NO INTERNAL sensor | EXTERNAL input max. 7 sensors | USB output<\/td>\n<\/tr>\n<tr>\n<td><strong>STARW<\/strong><\/td>\n<td>NO INTERNAL sensor | EXTERNAL input max. 7 sensors | USB output | Wireless transmission<\/td>\n<\/tr>\n<tr>\n<td><strong>STAR1BAR<\/strong><\/td>\n<td>INTERNAL sensor 1 bar Relative | EXTERNAL input max. 7 sensors | USB output<\/td>\n<\/tr>\n<tr>\n<td><strong>STAR100NW<\/strong><\/td>\n<td>INTERNAL sensor 100 N | EXTERNAL input max. 7 sensors | USB output | Wireless transmission<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>PRESSURE internal sensor resolution:<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<thead>\n<tr>\n<th colspan=\"2\">bar<\/th>\n<th colspan=\"2\">mbar<\/th>\n<th colspan=\"2\">psi<\/th>\n<th colspan=\"2\">MPa<\/th>\n<th colspan=\"2\">kPa<\/th>\n<th colspan=\"2\">Pa<\/th>\n<th colspan=\"2\">mH2O<\/th>\n<\/tr>\n<tr>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0.1000<\/td>\n<td>0.0001<\/td>\n<td>100.00<\/td>\n<td>0.01<\/td>\n<td>1.4500<\/td>\n<td>0.0001<\/td>\n<td>0.0100<\/td>\n<td>0.0001<\/td>\n<td>10.000<\/td>\n<td>0.001<\/td>\n<td>10000<\/td>\n<td>1<\/td>\n<td>1.0000<\/td>\n<td>0.0001<\/td>\n<\/tr>\n<tr>\n<td>0.5000<\/td>\n<td>0.0001<\/td>\n<td>500.00<\/td>\n<td>0.10<\/td>\n<td>7.2000<\/td>\n<td>0.0010<\/td>\n<td>0.0500<\/td>\n<td>0.0001<\/td>\n<td>50.000<\/td>\n<td>0.005<\/td>\n<td>50000<\/td>\n<td>5<\/td>\n<td>5.0000<\/td>\n<td>0.0005<\/td>\n<\/tr>\n<tr>\n<td>1.0000<\/td>\n<td>0.0001<\/td>\n<td>1000.0<\/td>\n<td>0.1<\/td>\n<td>14.500<\/td>\n<td>0.0001<\/td>\n<td>0.1000<\/td>\n<td>0.0001<\/td>\n<td>100.00<\/td>\n<td>0.01<\/td>\n<td>100000<\/td>\n<td>10<\/td>\n<td>10.000<\/td>\n<td>0.001<\/td>\n<\/tr>\n<tr>\n<td>2.5000<\/td>\n<td>0.0005<\/td>\n<td>2500.0<\/td>\n<td>0.5<\/td>\n<td>36.200<\/td>\n<td>0.005<\/td>\n<td>0.2500<\/td>\n<td>0.0001<\/td>\n<td>250.00<\/td>\n<td>0.05<\/td>\n<td>250000<\/td>\n<td>50<\/td>\n<td>25.500<\/td>\n<td>0.005<\/td>\n<\/tr>\n<tr>\n<td>5.0000<\/td>\n<td>0.0005<\/td>\n<td>5000.0<\/td>\n<td>0.5<\/td>\n<td>72.500<\/td>\n<td>0.005<\/td>\n<td>0.5000<\/td>\n<td>0.0001<\/td>\n<td>500.00<\/td>\n<td>0.05<\/td>\n<td>500000<\/td>\n<td>50<\/td>\n<td>51.000<\/td>\n<td>0.05<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<thead>\n<tr>\n<th colspan=\"2\">inH2O<\/th>\n<th colspan=\"2\">Kg\/cm\u00b2<\/th>\n<th colspan=\"2\">mmHg<\/th>\n<th colspan=\"2\">cmHg<\/th>\n<th colspan=\"2\">inHg<\/th>\n<th colspan=\"2\">Atm<\/th>\n<\/tr>\n<tr>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>40.000<\/td>\n<td>0.005<\/td>\n<td>0.1000<\/td>\n<td>0.0001<\/td>\n<td>75.00<\/td>\n<td>0.01<\/td>\n<td>7.500<\/td>\n<td>0.001<\/td>\n<td>3.0000<\/td>\n<td>0.0002<\/td>\n<td>0.1000<\/td>\n<td>0.0001<\/td>\n<\/tr>\n<tr>\n<td>200.00<\/td>\n<td>0.02<\/td>\n<td>0.5000<\/td>\n<td>0.0001<\/td>\n<td>375.00<\/td>\n<td>0.05<\/td>\n<td>37.500<\/td>\n<td>0.005<\/td>\n<td>14.500<\/td>\n<td>0.002<\/td>\n<td>0.5000<\/td>\n<td>0.0001<\/td>\n<\/tr>\n<tr>\n<td>400.00<\/td>\n<td>0.05<\/td>\n<td>1.0000<\/td>\n<td>0.0001<\/td>\n<td>750.0<\/td>\n<td>0.1<\/td>\n<td>75.00<\/td>\n<td>0.01<\/td>\n<td>30.000<\/td>\n<td>0.002<\/td>\n<td>1.0000<\/td>\n<td>0.0001<\/td>\n<\/tr>\n<tr>\n<td>1000.00<\/td>\n<td>0.10<\/td>\n<td>2.5500<\/td>\n<td>0.0005<\/td>\n<td>1900.0<\/td>\n<td>0.2<\/td>\n<td>190.00<\/td>\n<td>0.02<\/td>\n<td>75.00<\/td>\n<td>0.01<\/td>\n<td>2.5000<\/td>\n<td>0.0002<\/td>\n<\/tr>\n<tr>\n<td>2000.0<\/td>\n<td>0.2<\/td>\n<td>5.0000<\/td>\n<td>0.0005<\/td>\n<td>3750.0<\/td>\n<td>0.5<\/td>\n<td>375.00<\/td>\n<td>0.05<\/td>\n<td>145.00<\/td>\n<td>0.02<\/td>\n<td>5.0000<\/td>\n<td>0.0005<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Limit pressure: 150% Full scale.<\/p>\n<p>FORCE internal sensor resolution:<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<thead>\n<tr>\n<th colspan=\"2\">N<\/th>\n<th colspan=\"2\">daN<\/th>\n<th colspan=\"2\">kN<\/th>\n<th colspan=\"2\">kg<\/th>\n<th colspan=\"2\">g<\/th>\n<th colspan=\"2\">lb<\/th>\n<\/tr>\n<tr>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<th>FS<\/th>\n<th>Res.<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>10.000<\/td>\n<td>0.005<\/td>\n<td>1.0000<\/td>\n<td>0.0005<\/td>\n<td>0.0100<\/td>\n<td>0.0005<\/td>\n<td>1.0000<\/td>\n<td>0.0005<\/td>\n<td>1000.0<\/td>\n<td>0.5<\/td>\n<td>2.2000<\/td>\n<td>0.001<\/td>\n<\/tr>\n<tr>\n<td>25.000<\/td>\n<td>0.005<\/td>\n<td>2.5000<\/td>\n<td>0.0005<\/td>\n<td>0.0250<\/td>\n<td>0.0005<\/td>\n<td>2.5000<\/td>\n<td>0.0005<\/td>\n<td>2500.0<\/td>\n<td>0.5<\/td>\n<td>5.5000<\/td>\n<td>0.001<\/td>\n<\/tr>\n<tr>\n<td>50.000<\/td>\n<td>0.005<\/td>\n<td>5.0000<\/td>\n<td>0.0005<\/td>\n<td>0.0500<\/td>\n<td>0.0005<\/td>\n<td>5.0000<\/td>\n<td>0.0005<\/td>\n<td>5000.0<\/td>\n<td>0.5<\/td>\n<td>11.000<\/td>\n<td>0.001<\/td>\n<\/tr>\n<tr>\n<td>100.00<\/td>\n<td>0.05<\/td>\n<td>10.000<\/td>\n<td>0.005<\/td>\n<td>0.1000<\/td>\n<td>0.005<\/td>\n<td>10.000<\/td>\n<td>0.005<\/td>\n<td>10000<\/td>\n<td>5<\/td>\n<td>22.000<\/td>\n<td>0.01<\/td>\n<\/tr>\n<tr>\n<td>250.00<\/td>\n<td>0.05<\/td>\n<td>25.000<\/td>\n<td>0.005<\/td>\n<td>0.2500<\/td>\n<td>0.005<\/td>\n<td>25.000<\/td>\n<td>0.005<\/td>\n<td>25000<\/td>\n<td>5<\/td>\n<td>55.000<\/td>\n<td>0.01<\/td>\n<\/tr>\n<tr>\n<td>500.00<\/td>\n<td>0.05<\/td>\n<td>50.000<\/td>\n<td>0.005<\/td>\n<td>0.5000<\/td>\n<td>0.005<\/td>\n<td>50.000<\/td>\n<td>0.005<\/td>\n<td>50000<\/td>\n<td>5<\/td>\n<td>110.00<\/td>\n<td>0.01<\/td>\n<\/tr>\n<tr>\n<td>1000.0<\/td>\n<td>0.5<\/td>\n<td>100.00<\/td>\n<td>0.05<\/td>\n<td>1.0000<\/td>\n<td>0.0005<\/td>\n<td>100.00<\/td>\n<td>0.05<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>220.00<\/td>\n<td>0.1<\/td>\n<\/tr>\n<tr>\n<td>3000.0<\/td>\n<td>0.5<\/td>\n<td>300.00<\/td>\n<td>0.05<\/td>\n<td>3.0000<\/td>\n<td>0.0005<\/td>\n<td>300.00<\/td>\n<td>0.05<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>660.00<\/td>\n<td>0.1<\/td>\n<\/tr>\n<tr>\n<td>5000.0<\/td>\n<td>0.5<\/td>\n<td>500.00<\/td>\n<td>0.05<\/td>\n<td>5.0000<\/td>\n<td>0.0005<\/td>\n<td>500.00<\/td>\n<td>0.05<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>1100.0<\/td>\n<td>0.1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Internally the microcontroller process the signals coming from the sensors through a 24 bit (\u00b150.000 divisions at 2mV\/V) analogue digital converter at a conversion frequency varying from 5Hz at 4800Hz by making it suitable for every application that may require both high resolution and high sampling frequencies. The display of measurements happens through a big graphic backlighted display. Star is equipped with USB interface that allows both the communication in real-time with a PC and the recharge of the internal long-lasting and great reliability battery (Li-Ion). In addition to the direct reading of the measurements, it is possible to detect PEAKS, block the measurement on the display thanks to the HOLD function and through the internal DATA LOGGER it is possible to record up to 130.000 measurement at programmed intervals or manually through the REC button. On request, as an\u00a0<strong>OPTION<\/strong>\u00a0it is possible to integrate a WIRELESS interface that allows to communicate with PC, TABLET or PLC in real time. By using WinWIMOD software it is possible to create a NETWORK with a max. number of 32 units, the net can consist of both STAR instruments and sensors interfaced with WIMOD. Metal case Li-Ion internal battery which ensures a 24 hours AUTONOMY Protection class IP40 Functions ZERO, FILTER, PEAK, AUTO POWER OFF, DATA LOGGER, REC \u2026.. USB output Included: travelling case made of ABS and feeder with USB cable<\/p>\n","protected":false},"featured_media":285876,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5397],"product_cat":[3418],"product_tag":[4959,5023,5409,4751],"class_list":{"0":"post-285874","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-aep-transducers","7":"product_cat-portable-indicator","8":"product_tag-force-sensor","9":"product_tag-force-sensor-en","10":"product_tag-force-transducers-en","11":"product_tag-indicator","13":"first","14":"instock","15":"taxable","16":"shipping-taxable","17":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/285874","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=285874"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/285876"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=285874"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=285874"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=285874"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=285874"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}