{"id":285898,"date":"2025-11-27T10:01:50","date_gmt":"2025-11-27T01:01:50","guid":{"rendered":"https:\/\/casscale.net\/?post_type=product&#038;p=285898"},"modified":"2026-03-18T11:37:31","modified_gmt":"2026-03-18T02:37:31","slug":"aep-transducers-clf-force-transducers","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/aep-transducers-clf-force-transducers\/","title":{"rendered":"AEP transducers \/ CLF \/ Force transducers"},"content":{"rendered":"<h4>Force transducers for the measurement of static and dynamic loads in\u00a0<strong>COMPRESSION<\/strong><\/h4>\n<p>Force transducers for the measurement of static and dynamic loads in\u00a0<strong>COMPRESSION<\/strong>.<br \/>\nNominal Load from\u00a0<strong>300 kN<\/strong>\u00a0to\u00a0<strong>5 MN<br \/>\n<\/strong>Class (ISO 376) 1<br \/>\nLinearity and Hysteresis 0,05%<br \/>\nOutput: 2mV\/V<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-285713\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/label-eac-2.jpg\" alt=\"\" width=\"150\" height=\"70\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/label-eac-2.jpg 150w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/label-eac-2-64x30.jpg 64w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-285903\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/CLF_1.jpg\" alt=\"\" width=\"303\" height=\"358\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/CLF_1.jpg 303w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/CLF_1-64x76.jpg 64w\" sizes=\"(max-width: 303px) 100vw, 303px\" \/><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<thead>\n<tr>\n<th>Code<\/th>\n<th>Load<\/th>\n<th>\u00d8A<\/th>\n<th>\u00d8 B<\/th>\n<th>\u00d8 C<\/th>\n<th>D<\/th>\n<th>E<\/th>\n<th>F<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>CCLF300KN<\/td>\n<td>300 kN<\/td>\n<td rowspan=\"5\">129<\/td>\n<td rowspan=\"5\">100<\/td>\n<td rowspan=\"5\">100<\/td>\n<td rowspan=\"5\">164<\/td>\n<td rowspan=\"5\">12<\/td>\n<td rowspan=\"5\">10<\/td>\n<\/tr>\n<tr>\n<td>CCLF600KN<\/td>\n<td>600 kN<\/td>\n<\/tr>\n<tr>\n<td>CCLF1MN<\/td>\n<td>1 MN<\/td>\n<\/tr>\n<tr>\n<td>CCLF2MN<\/td>\n<td>2 MN<\/td>\n<\/tr>\n<tr>\n<td>CCLF3MN<\/td>\n<td>3 MN<\/td>\n<\/tr>\n<tr>\n<td>CCLF5MN<\/td>\n<td>5 MN<\/td>\n<td>168<\/td>\n<td>140<\/td>\n<td>160<\/td>\n<td>203<\/td>\n<td>17<\/td>\n<td>5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><em>Technical Data<\/em><\/strong><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<tbody>\n<tr>\n<td><em>Accuracy class: <strong>ISO 376<\/strong><\/em><\/td>\n<td colspan=\"2\"><strong>1<\/strong><\/td>\n<\/tr>\n<tr>\n<td><em>NOMINAL LOAD<\/em><\/td>\n<td colspan=\"2\">300kN, 600kN, 1MN, 2MN, 3MN, 5MN <sup>(1)<\/sup><\/td>\n<\/tr>\n<tr>\n<td><em>RELATIVE ERRORS (<strong>at reading<\/strong>)<\/em><br \/>\na) repeatability 0\u00b0-120\u00b0-240\u00b0 (b)<br \/>\nb) interpolation (fc)<br \/>\nc) reversibility (u)<br \/>\nd) zero (fo)<\/td>\n<td colspan=\"2\"><strong class=\"Yjhzub\">\u2264<\/strong>\u00b10.145%<br \/>\n<strong class=\"Yjhzub\">\u2264<\/strong>\u00b10.090%<br \/>\n<strong class=\"Yjhzub\">\u2264<\/strong>\u00b10.240%<br \/>\n<strong class=\"Yjhzub\">\u2264<\/strong>\u00b10.030% F.S.<\/td>\n<\/tr>\n<tr>\n<td><em>LINEARITY HYSTERESIS<\/em><\/td>\n<td colspan=\"2\"><strong class=\"Yjhzub\">\u2264<\/strong>\u00b10.05% F.S.<br \/>\n<strong class=\"Yjhzub\">\u2264<\/strong>\u00b10.05% F.S.<\/td>\n<\/tr>\n<tr>\n<td><em>TEMPERATURE EFFECT (10\u00b0C)<\/em><br \/>\na) on zero<br \/>\nb) on sensitivity<br \/>\nEFFECT OF TRANSVERSE LOAD:<br \/>\na) at 10% of nominal load<\/td>\n<td colspan=\"2\"><strong class=\"Yjhzub\">\u2264<\/strong>\u00b10.028% F.S.<br \/>\n<strong class=\"Yjhzub\">\u2264<\/strong>\u00b10.024% F.S.<strong class=\"Yjhzub\">\u2264<\/strong>\u00b10.030% F.S.<\/td>\n<\/tr>\n<tr>\n<td><em>NOMINAL SENSITIVITY SENSIVITY TOLERANCE<\/em><\/td>\n<td colspan=\"2\">2mV\/V<br \/>\n<strong class=\"Yjhzub\">\u2264<\/strong>\u00b10.1% F.S.<\/td>\n<\/tr>\n<tr>\n<td><em>NOMINAL LOAD<\/em><br \/>\nInput resistance Output resistance<\/td>\n<td colspan=\"2\"><strong>300kN, 600kN, 1MN<\/strong><br \/>\n700 \u00b1 2\u03a9<br \/>\n700 \u00b1 2\u03a9<\/td>\n<\/tr>\n<tr>\n<td><em>NOMINAL LOAD<\/em><br \/>\nInput resistance Output resistance<\/td>\n<td colspan=\"2\"><strong>2, 3, 5 MN<\/strong><br \/>\n350 \u00b1 2\u03a9<br \/>\n350 \u00b1 2\u03a9<\/td>\n<\/tr>\n<tr>\n<td><em>INSULATION RESISTANCE ZERO BALANCE<\/em><br \/>\nRECOMMENDED SUPPLY VOLTAGE NOMINAL SUPPLY VOLTAGE RANGE MAXIMUM SUPPLY VOLTAGE<\/td>\n<td colspan=\"2\">&gt; 5 G\u03a9<br \/>\n<strong class=\"Yjhzub\">\u2264<\/strong>\u00b11% F.S.<br \/>\n10 V<br \/>\n1-15 V<br \/>\n18 V<\/td>\n<\/tr>\n<tr>\n<td><em>MECHANICAL LIMIT VALUES REFERRED TO NOMINAL LOAD:<\/em><br \/>\na) service load<br \/>\nb) max permissible load<br \/>\nc) breaking load<br \/>\nd) max transverse load<br \/>\ne) max permissible dynamic load<\/td>\n<td colspan=\"2\">120%<br \/>\n150%<br \/>\n&gt;300%<br \/>\n100%<br \/>\n50%<\/td>\n<\/tr>\n<tr>\n<td><em>REFERENCE TEMPERATURE TEMPERATURE NOMINAL RANGE SERVICE TEMPERATURE<\/em><br \/>\nSTORAGE TEMPERATURE<\/td>\n<td colspan=\"2\">+23\u00b0C<br \/>\n-10 \/ +40 \u00b0C<br \/>\n-10 \/ +70 \u00b0C<br \/>\n-20 \/ +80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td><em>WEIGHT (kg)<\/em><\/td>\n<td>300kN \u2026 3MN<br \/>\nfrom 7 kg to 15 kg<\/td>\n<td>500MN<br \/>\n<strong>~25kg<\/strong><\/td>\n<\/tr>\n<tr>\n<td><em>PROTECTION CLASS (EN 60529)<\/em><br \/>\nEXECUTION MATERIAL CONNECTOR TYPE<\/td>\n<td colspan=\"2\">IP65<br \/>\nAcciaio Inox \/ <em>Stainless Steel<\/em><br \/>\nMIL-C-5015 7 poles male<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>(1) <em>calibrazioni in kg a richiesta \/ kg calibration on request<\/em><\/p>\n<p><strong><em>Electrical Connections<\/em><\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-285905\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/CLF_5.png\" alt=\"\" width=\"812\" height=\"294\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/CLF_5.png 812w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/CLF_5-800x290.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/CLF_5-768x278.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/CLF_5-600x217.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/CLF_5-64x23.png 64w\" sizes=\"(max-width: 812px) 100vw, 812px\" \/><\/p>\n<p>*\u00a0 <em>Connected to the body of the transducer.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Column force transducer suitable for the calibration of material testing machines.<br \/>\nHigh mechanical resistance.<br \/>\nCompletely made of stainless steel.<br \/>\nCompletely LASER welded.<br \/>\nDegree of protection IP65.<br \/>\nLong term stability.<\/p>\n","protected":false},"featured_media":285900,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5397],"product_cat":[3448],"product_tag":[5408,4959,5023,5409],"class_list":{"0":"post-285898","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-aep-transducers","7":"product_cat-force-sensor","8":"product_tag-dynamometer-2-en","9":"product_tag-force-sensor","10":"product_tag-force-sensor-en","11":"product_tag-force-transducers-en","13":"first","14":"instock","15":"taxable","16":"shipping-taxable","17":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/285898","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=285898"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/285900"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=285898"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=285898"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=285898"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=285898"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}