{"id":285968,"date":"2025-11-27T13:59:12","date_gmt":"2025-11-27T04:59:12","guid":{"rendered":"https:\/\/casscale.net\/?post_type=product&#038;p=285968"},"modified":"2026-03-18T11:36:54","modified_gmt":"2026-03-18T02:36:54","slug":"aep-transducers-tc4-force-transducers","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc4-force-transducers\/","title":{"rendered":"AEP transducers \/ TC4 \/ Force transducers"},"content":{"rendered":"<h4>Force transducers for the measurement of static and dynamic loads in\u00a0<strong>COMPRESSION<\/strong>\u00a0and\u00a0<strong>TENSION<\/strong><\/h4>\n<p>Nominal Load from\u00a0<strong>2.5 kN<\/strong>\u00a0to\u00a0<strong>5 MN<br \/>\n<\/strong>Class (ISO 376) 1<br \/>\nLinearity and Hysteresis 0,05%<br \/>\nOutput: 2mV\/V<br \/>\non request<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-285727\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/WIRELESS-300x100.jpg\" alt=\"\" width=\"300\" height=\"100\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/WIRELESS-300x100.jpg 300w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/WIRELESS-300x100-64x21.jpg 64w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> <img decoding=\"async\" class=\"alignnone size-full wp-image-285729\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/ATEX-300x90.jpg\" alt=\"\" width=\"300\" height=\"90\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/ATEX-300x90.jpg 300w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/ATEX-300x90-295x90.jpg 295w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/ATEX-300x90-64x19.jpg 64w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><strong>Dimensions[mm]<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-285973\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_1.png\" alt=\"\" width=\"1462\" height=\"539\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_1.png 1462w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_1-800x295.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_1-1400x516.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_1-768x283.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_1-600x221.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_1-64x24.png 64w\" sizes=\"(max-width: 1462px) 100vw, 1462px\" \/><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"4\">\n<thead>\n<tr>\n<th>CODE<\/th>\n<th>LOAD<\/th>\n<th>CODE<\/th>\n<th>LOAD<\/th>\n<th>\u00c6A<\/th>\n<th>B<\/th>\n<th>C<\/th>\n<th>\u00c6D<\/th>\n<th>\u00c6E<\/th>\n<th>F<\/th>\n<th>G<\/th>\n<th>n\u00b0G<\/th>\n<th>H<\/th>\n<th>T<\/th>\n<th>KHz(2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>CTC4100250K5<\/td>\n<td>250 kg<\/td>\n<td>CTC41002KN5I15<\/td>\n<td>2,5 kN<\/td>\n<td rowspan=\"5\">100<\/td>\n<td rowspan=\"5\">86<\/td>\n<td rowspan=\"5\">35<\/td>\n<td rowspan=\"5\">72<\/td>\n<td rowspan=\"5\">32<\/td>\n<td rowspan=\"5\">M20\u00d71.5<\/td>\n<td rowspan=\"5\">9<\/td>\n<td rowspan=\"5\">6<\/td>\n<td rowspan=\"5\">121<\/td>\n<td rowspan=\"5\">7.5<\/td>\n<td>2.5<\/td>\n<\/tr>\n<tr>\n<td>CTC4100500K5<\/td>\n<td>500 kg<\/td>\n<td>CTC41005KNI15<\/td>\n<td>5 kN<\/td>\n<td>2.5<\/td>\n<\/tr>\n<tr>\n<td>CTC41001T5<\/td>\n<td>1 t<\/td>\n<td>CTC410010KNI15<\/td>\n<td>10 kN<\/td>\n<td>2.5<\/td>\n<\/tr>\n<tr>\n<td>CTC41002T55<\/td>\n<td>2.5 t<\/td>\n<td>CTC410025KNI15<\/td>\n<td>25 kN<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>CTC41005T5<\/td>\n<td>5 t (3)<\/td>\n<td>CTC410050KNI15<\/td>\n<td>50 kN<\/td>\n<td>8.6<\/td>\n<\/tr>\n<tr>\n<td>CTC41275T5<\/td>\n<td>5 t<\/td>\n<td>CTC412750KNI15<\/td>\n<td>50 kN<\/td>\n<td rowspan=\"2\">127<\/td>\n<td rowspan=\"2\">110<\/td>\n<td rowspan=\"2\">35<\/td>\n<td rowspan=\"2\">92<\/td>\n<td rowspan=\"2\">47<\/td>\n<td rowspan=\"2\">M30\u00d72<\/td>\n<td rowspan=\"2\">10.5<\/td>\n<td rowspan=\"2\">8<\/td>\n<td rowspan=\"2\">149<\/td>\n<td rowspan=\"2\">7.5<\/td>\n<td>3.8<\/td>\n<\/tr>\n<tr>\n<td>CTC412710T5<\/td>\n<td>10 t<\/td>\n<td>CTC4127100KNI15<\/td>\n<td>100 kN<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td>CTC416520T5<\/td>\n<td>20 t<\/td>\n<td>CTC4165200KNI15<\/td>\n<td>200 kN<\/td>\n<td rowspan=\"3\">165<\/td>\n<td rowspan=\"3\">138<\/td>\n<td rowspan=\"2\">50<\/td>\n<td rowspan=\"3\">108<\/td>\n<td rowspan=\"3\">62<\/td>\n<td rowspan=\"3\">M42\u00d73<\/td>\n<td rowspan=\"3\">17<\/td>\n<td rowspan=\"3\">12<\/td>\n<td rowspan=\"3\">188<\/td>\n<td rowspan=\"2\">15<\/td>\n<td>5.7<\/td>\n<\/tr>\n<tr>\n<td>CTC416530T5<\/td>\n<td>30 t<\/td>\n<td>CTC4165300KNI15<\/td>\n<td>300 kN<\/td>\n<td>7.3<\/td>\n<\/tr>\n<tr>\n<td>CTC416550T5<\/td>\n<td>50 t<\/td>\n<td>CTC4165500KNI15<\/td>\n<td>500 kN<\/td>\n<td>60<\/td>\n<td>20<\/td>\n<td>9.8<\/td>\n<\/tr>\n<tr>\n<td>CTC423075T5<\/td>\n<td>75 t<\/td>\n<td>CTC4230750KNI15<\/td>\n<td>750 kN<\/td>\n<td rowspan=\"2\">230<\/td>\n<td rowspan=\"2\">185<\/td>\n<td rowspan=\"2\">80<\/td>\n<td rowspan=\"2\">145<\/td>\n<td rowspan=\"2\">98<\/td>\n<td rowspan=\"2\">M60\u00d73<\/td>\n<td rowspan=\"2\">25<\/td>\n<td rowspan=\"2\">12<\/td>\n<td rowspan=\"2\">254<\/td>\n<td rowspan=\"2\">30<\/td>\n<td rowspan=\"2\">3.2<\/td>\n<\/tr>\n<tr>\n<td>CTC4230100T5<\/td>\n<td>100 t<\/td>\n<td>CTC42301MNI15<\/td>\n<td>1 MN<\/td>\n<\/tr>\n<tr>\n<td>CTC4300200T5<\/td>\n<td>200 t<\/td>\n<td>CTC43002MNI15<\/td>\n<td>2 MN<\/td>\n<td>300<\/td>\n<td>250<\/td>\n<td>100<\/td>\n<td>198<\/td>\n<td>132<\/td>\n<td>M100\u00d73<\/td>\n<td>25<\/td>\n<td>16<\/td>\n<td>339<\/td>\n<td>50<\/td>\n<td>2.7<\/td>\n<\/tr>\n<tr>\n<td>CTC4350300T5<\/td>\n<td>300 t<\/td>\n<td>CTC43503MNI15<\/td>\n<td>3 MN<\/td>\n<td rowspan=\"2\">350<\/td>\n<td rowspan=\"2\">294<\/td>\n<td>120<\/td>\n<td rowspan=\"2\">238<\/td>\n<td>168<\/td>\n<td rowspan=\"2\">M100\u00d73<\/td>\n<td rowspan=\"2\">28<\/td>\n<td rowspan=\"2\">16<\/td>\n<td rowspan=\"2\">389<\/td>\n<td>60<\/td>\n<td rowspan=\"2\">2.8<\/td>\n<\/tr>\n<tr>\n<td>CTC4350500T5<\/td>\n<td>500 t<\/td>\n<td>CTC43505MNI15<\/td>\n<td>5 MN<\/td>\n<td>130<\/td>\n<td>178<\/td>\n<td>65<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>(1) ACCREDIA certification in TENSION can NOT be performed by LAT n\u00b0 93 Laboratory, on request it can be ordered to other accredited laboratories.<br \/>\n(2) Natural frequency<\/p>\n<p><strong>Technical Data<\/strong><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"4\">\n<thead>\n<tr>\n<th>Accuracy class<\/th>\n<th colspan=\"7\">1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NOMINAL LOAD<\/td>\n<td>2.5 &#8211; 5 kN<br \/>\n10 &#8211; 25 kN<br \/>\n50<sup>(3)<\/sup> kN<\/td>\n<td>50 kN<br \/>\n100 kN<\/td>\n<td>200 kN<br \/>\n300 kN<\/td>\n<td>500 kN<\/td>\n<td>750 kN<br \/>\n1 MN<\/td>\n<td>2 MN<\/td>\n<td>3 MN(4)<br \/>\n5 MN(4)<\/td>\n<\/tr>\n<tr>\n<td>RELATIVE ERRORS (at reading)<\/td>\n<td colspan=\"7\"><\/td>\n<\/tr>\n<tr>\n<td>a) reproducibility 0\u00b0-120\u00b0-240\u00b0 (b)<\/td>\n<td colspan=\"7\">\u2264 \u00b10.145 %<sup>(5)<\/sup><\/td>\n<\/tr>\n<tr>\n<td>b) interpolation (fc)<\/td>\n<td colspan=\"7\">\u2264 \u00b10.090 %<sup>(5)<\/sup><\/td>\n<\/tr>\n<tr>\n<td>c) reversibility (v)<\/td>\n<td colspan=\"7\">\u2264 \u00b10.240 %<sup>(5)<\/sup><\/td>\n<\/tr>\n<tr>\n<td>d) zero (fo)<\/td>\n<td colspan=\"7\">\u2264 \u00b10.030 % F.S.<\/td>\n<\/tr>\n<tr>\n<td>LINEARITY HYSTERESIS<\/td>\n<td colspan=\"5\">\u2264 \u00b10.05 % F.S.<br \/>\n\u2264 \u00b10.05 % F.S.<\/td>\n<td colspan=\"2\">\u2264 \u00b10.10 % F.S.<br \/>\n\u2264 \u00b10.10 % F.S.<\/td>\n<\/tr>\n<tr>\n<td>TEMPERATURE EFFECT (10\u00b0C)<\/td>\n<td colspan=\"7\" rowspan=\"5\">\u2264 \u00b10.028 % F.S.<br \/>\n\u2264 \u00b10.024 % F.S.\u2264 \u00b10.030 % F.S.<\/td>\n<\/tr>\n<tr>\n<td>a) on zero<\/td>\n<\/tr>\n<tr>\n<td>b) on sensitivity<\/td>\n<\/tr>\n<tr>\n<td>EFFECT OF TRANSVERSE LOAD:<\/td>\n<\/tr>\n<tr>\n<td>a) at 10% of nominal load<\/td>\n<\/tr>\n<tr>\n<td>NOMINAL SENSITIVITY<br \/>\nSENSITIVITY TOLERANCE<\/td>\n<td colspan=\"7\">2 mV\/V <sup>(6)<\/sup><br \/>\n\u00b10.1 % F.S.<\/td>\n<\/tr>\n<tr>\n<td>NOMINAL LOAD<\/td>\n<td colspan=\"7\"><strong>2.5 &#8211; 5 &#8211; 10 &#8211; 25 &#8211; 50 &#8211; 100 &#8211; 200 &#8211; 300 &#8211; 500 kN<\/strong><\/td>\n<\/tr>\n<tr>\n<td>INPUT RESISTANCE<\/td>\n<td colspan=\"7\">800 \u00b1 20 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>OUTPUT RESISTANCE<\/td>\n<td colspan=\"7\">705 \u00b1 2 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>NOMINAL LOAD<\/td>\n<td colspan=\"7\"><strong>750 &#8211; 1000 \u2013 2000 \u2013 3000 &#8211; 5000 kN<\/strong><\/td>\n<\/tr>\n<tr>\n<td>INPUT RESISTANCE<\/td>\n<td colspan=\"7\">430 \u00b1 20 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>OUTPUT RESISTANCE<\/td>\n<td colspan=\"7\">352 \u00b1 2 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>INSULATION RESISTANCE ZERO BALANCE<\/td>\n<td colspan=\"7\">&gt; 5 G\u03a9<br \/>\n\u2264 \u00b11 % F.S.<\/td>\n<\/tr>\n<tr>\n<td>RECOMMENDED SUPPLY VOLTAGE<\/td>\n<td colspan=\"7\">10 V<\/td>\n<\/tr>\n<tr>\n<td>NOMINAL SUPPLY VOLTAGE RANGE<\/td>\n<td colspan=\"7\">1-15 V<\/td>\n<\/tr>\n<tr>\n<td>MAXIMUM SUPPLY VOLTAGE<\/td>\n<td colspan=\"7\">18 V<\/td>\n<\/tr>\n<tr>\n<td>MECHANICAL LIMIT VALUES REFERRED<\/td>\n<td colspan=\"7\"><\/td>\n<\/tr>\n<tr>\n<td>TO NOMINAL LOAD:<\/td>\n<td colspan=\"7\"><\/td>\n<\/tr>\n<tr>\n<td>a) service load<\/td>\n<td colspan=\"7\">120 %<\/td>\n<\/tr>\n<tr>\n<td>b) max permissible load<\/td>\n<td colspan=\"7\">150 %<\/td>\n<\/tr>\n<tr>\n<td>c) breaking load<\/td>\n<td colspan=\"7\">&gt; 300 %<\/td>\n<\/tr>\n<tr>\n<td>d) max transverse load<\/td>\n<td colspan=\"7\">100 %<\/td>\n<\/tr>\n<tr>\n<td>e) max permissible dynamic load<\/td>\n<td colspan=\"7\">75 % (7)<\/td>\n<\/tr>\n<tr>\n<td>Displacement at nominal load (mm)<\/td>\n<td>~0.06<\/td>\n<td>~0.09<\/td>\n<td>~0.17<\/td>\n<td>~0.17<\/td>\n<td>~0.23<\/td>\n<td>~0.21<\/td>\n<td>~0.21<\/td>\n<\/tr>\n<tr>\n<td>REFERENCE TEMPERATURE<\/td>\n<td colspan=\"7\">+23 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>TEMPERATURE NOMINAL RANGE<\/td>\n<td colspan=\"7\">-10 \/ +40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>SERVICE TEMPERATURE<\/td>\n<td colspan=\"7\">-10 \/ +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>STORAGE TEMPERATURE<\/td>\n<td colspan=\"7\">-20 \/ +80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>WEIGHT (kg)<\/td>\n<td>~1.6<\/td>\n<td>~2.5<\/td>\n<td>~5.8<\/td>\n<td>~6.8<\/td>\n<td>~16.5<\/td>\n<td>~35<\/td>\n<td>~63<\/td>\n<\/tr>\n<tr>\n<td>PROTECTION CLASS (EN 60529)<br \/>\nEXECUTION MATERIAL<br \/>\nCABLE LENGTH<\/td>\n<td colspan=\"7\">IP67<br \/>\nAcciaio Inox \/ Stainless Steel<br \/>\n5 m (on request 10 m)<\/td>\n<\/tr>\n<tr>\n<td>FIXING SCREWS:<\/td>\n<td colspan=\"7\"><\/td>\n<\/tr>\n<tr>\n<td>a) diameter<\/td>\n<td>M8<\/td>\n<td>M10<\/td>\n<td>M16<\/td>\n<td>M16<\/td>\n<td>M24<\/td>\n<td>M24<\/td>\n<td>M27<\/td>\n<\/tr>\n<tr>\n<td>b) resistance class<\/td>\n<td>12.9<\/td>\n<td>12.9<\/td>\n<td>12.9<\/td>\n<td>12.9<\/td>\n<td>12.9<\/td>\n<td>12.9<\/td>\n<td>12.9<\/td>\n<\/tr>\n<tr>\n<td>c) tightening torque (Nm)<\/td>\n<td>40<\/td>\n<td>70<\/td>\n<td>368<\/td>\n<td>368<\/td>\n<td>460<\/td>\n<td>460<\/td>\n<td>1500<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>3)The force transducer 50 kN \u00d8100 is guaranteed in TENSION up to 25 kN.<br \/>\n(4)The force transducers 3 MN and 5 MN are guaranteed in TENSION up to 2,5 MN.<br \/>\n(5)Percentage errors referred to reading, min. 1\/10 of nominal load.<br \/>\n(6)Tests and calibrations performed in COMPRESSION with the transducer mounted on a bearing support with correctly tightened clamping screws.<br \/>\n(7)The dynamic load must be applied to the transducer central thread and not to the external fixing rim.<br \/>\nkg calibration on request.<br \/>\nClassifications according ASTM E74 on request.<\/p>\n<p><strong>Dimensions[mm]<\/strong><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"4\">\n<thead>\n<tr>\n<th>TC4:<\/th>\n<th>A<\/th>\n<th>B<\/th>\n<th>C<\/th>\n<th>D<\/th>\n<th>E<\/th>\n<th>F<\/th>\n<th>G<\/th>\n<th>H<\/th>\n<th>L<\/th>\n<th>M<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2.5, 5, 10, 25, 50 kN<\/td>\n<td>108<\/td>\n<td>37<\/td>\n<td>35<\/td>\n<td>36<\/td>\n<td>\u00d8 57<\/td>\n<td>\u00d8 100<\/td>\n<td>\u00d8 70<\/td>\n<td>M 20 \u00d7 1.5<\/td>\n<td>\u00d8 32<\/td>\n<td>~ 170<\/td>\n<\/tr>\n<tr>\n<td>50, 100 kN<\/td>\n<td>108<\/td>\n<td>37<\/td>\n<td>35<\/td>\n<td>36<\/td>\n<td>\u00d8 76<\/td>\n<td>\u00d8 127<\/td>\n<td>\u00d8 100<\/td>\n<td>M 30 \u00d7 2<\/td>\n<td>\u00d8 47<\/td>\n<td>~ 200<\/td>\n<\/tr>\n<tr>\n<td>200 kN<\/td>\n<td>169<\/td>\n<td>60<\/td>\n<td>50<\/td>\n<td>59<\/td>\n<td>\u00d8 76<\/td>\n<td>\u00d8 165<\/td>\n<td>\u00d8 100<\/td>\n<td>M 42 \u00d7 3<\/td>\n<td>\u00d8 62<\/td>\n<td>~ 224<\/td>\n<\/tr>\n<tr>\n<td>300 kN<\/td>\n<td>169<\/td>\n<td>60<\/td>\n<td>50<\/td>\n<td>59<\/td>\n<td>\u00d8 76<\/td>\n<td>\u00d8 165<\/td>\n<td>\u00d8 100<\/td>\n<td>M 42 \u00d7 3<\/td>\n<td>\u00d8 62<\/td>\n<td>~ 465<\/td>\n<\/tr>\n<tr>\n<td>500 kN<\/td>\n<td>179<\/td>\n<td>60<\/td>\n<td>60<\/td>\n<td>59<\/td>\n<td>\u00d8 76<\/td>\n<td>\u00d8 165<\/td>\n<td>\u00d8 100<\/td>\n<td>M 42 \u00d7 3<\/td>\n<td>\u00d8 62<\/td>\n<td>~ 513<\/td>\n<\/tr>\n<tr>\n<td>750 kN, 1 MN<\/td>\n<td>252<\/td>\n<td>85<\/td>\n<td>80<\/td>\n<td>87<\/td>\n<td>\u00d8 126<\/td>\n<td>\u00d8 230<\/td>\n<td>\u00d8 180<\/td>\n<td>M 60 \u00d7 3<\/td>\n<td>\u00d8 98<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>2 MN<\/td>\n<td>309<\/td>\n<td>85<\/td>\n<td>100<\/td>\n<td>124<\/td>\n<td>\u00d8 129<\/td>\n<td>\u00d8 300<\/td>\n<td>\u00d8 250<\/td>\n<td>M100 \u00d7 3<\/td>\n<td>\u00d8 132<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>3 MN<\/td>\n<td>384<\/td>\n<td>120<\/td>\n<td>120<\/td>\n<td>144<\/td>\n<td>\u00d8 168<\/td>\n<td>\u00d8 350<\/td>\n<td>\u00d8 330<\/td>\n<td>M100 \u00d7 3<\/td>\n<td>\u00d8 178<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>5 MN<\/td>\n<td>394<\/td>\n<td>120<\/td>\n<td>130<\/td>\n<td>144<\/td>\n<td>\u00d8 168<\/td>\n<td>\u00d8 350<\/td>\n<td>\u00d8 330<\/td>\n<td>M100 \u00d7 3<\/td>\n<td>\u00d8 178<\/td>\n<td>\/<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"4\">\n<thead>\n<tr>\n<th>TC4:<\/th>\n<th><em>CODE<\/em><\/th>\n<th><\/th>\n<th><em>ACCESSORIES (optional):<\/em><\/th>\n<th>ACCESSORI (opzionali):<\/th>\n<\/tr>\n<\/thead>\n<tbody><!-- 2.5 ~ 50 kN --><\/p>\n<tr>\n<td rowspan=\"4\"><strong>2.5, 5, 10, 25, 50 kN<\/strong><\/td>\n<td>CTIC22<\/td>\n<td>\u2460<\/td>\n<td><em>Loading head.<\/em><\/td>\n<td>Testa di carico.<\/td>\n<\/tr>\n<tr>\n<td>CTC425M20<\/td>\n<td>\u2461<\/td>\n<td><em>Spherical loading head M20\u00d71.5.<\/em><\/td>\n<td>Testa di carico sferica M20\u00d71.5<\/td>\n<\/tr>\n<tr>\n<td>CPBTC4D100<\/td>\n<td>\u2462<\/td>\n<td><em>Mounting plate \u00c6 100 mm.<\/em><\/td>\n<td>Piastra base \u00c6 100 mm.<\/td>\n<\/tr>\n<tr>\n<td>CACCEM20<\/td>\n<td>\u2463<\/td>\n<td><em>Knuckle joints.<\/em><\/td>\n<td>Teste a snodo sferico.<\/td>\n<\/tr>\n<p><!-- 50, 100 kN --><\/p>\n<tr>\n<td rowspan=\"4\"><strong>50, 100 kN<\/strong><\/td>\n<td>CTIC28<\/td>\n<td>\u2460<\/td>\n<td><em>Loading head.<\/em><\/td>\n<td>Testa di carico.<\/td>\n<\/tr>\n<tr>\n<td>CTC445M30\u2461<\/td>\n<td>\u2461<\/td>\n<td><em>Spherical loading head M30\u00d72.<\/em><\/td>\n<td>Testa di carico sferica M30\u00d72.<\/td>\n<\/tr>\n<tr>\n<td>CPBTC4D127<\/td>\n<td>\u2462<\/td>\n<td><em>Mounting plate \u00c6 127 mm.<\/em><\/td>\n<td>Piastra base \u00c6 127 mm.<\/td>\n<\/tr>\n<tr>\n<td>CACCEM30<\/td>\n<td>\u2463<\/td>\n<td><em>Knuckle joints.<\/em><\/td>\n<td>Teste a snodo sferico.<\/td>\n<\/tr>\n<p><!-- 200, 300, 500 kN --><\/p>\n<tr>\n<td rowspan=\"7\"><strong>200, 300, 500 kN<\/strong><\/td>\n<td>CTIC35<\/td>\n<td>\u2460<\/td>\n<td><em>Loading head.<\/em><\/td>\n<td>Testa di carico.<\/td>\n<\/tr>\n<tr>\n<td>CTS62M42TC4<\/td>\n<td>\u2461<\/td>\n<td><em>Spherical loading head M42\u00d73 (200-300kN)<\/em><\/td>\n<td>Testa di carico sferica M42\u00d73 (200-300kN)<\/td>\n<\/tr>\n<tr>\n<td>CTS62M42TC450T<\/td>\n<td>\u2461<\/td>\n<td><em>Spherical loading head M42\u00d73 (500kN)<\/em><\/td>\n<td>Testa di carico sferica M42\u00d73 (500kN)<\/td>\n<\/tr>\n<tr>\n<td>CPBTC4D165<\/td>\n<td>\u2462<\/td>\n<td><em>Mounting plate \u00c6 165 mm.<\/em><\/td>\n<td>Piastra base \u00c6 165 mm.<\/td>\n<\/tr>\n<tr>\n<td>CACCEM42<\/td>\n<td>\u2463<\/td>\n<td><em>Knuckle joints. (max 200KN)<\/em><\/td>\n<td>Teste a snodo sferico. (max 200kN)<\/td>\n<\/tr>\n<tr>\n<td>CACCEM4230T<\/td>\n<td>\u2463<\/td>\n<td><em>Knuckle joints. (max 300KN)<\/em><\/td>\n<td>Teste a snodo sferico. (max 300kN)<\/td>\n<\/tr>\n<tr>\n<td>CACCEM4250T<\/td>\n<td>\u2463<\/td>\n<td><em>Knuckle joints. (max 500KN)<\/em><\/td>\n<td>Teste a snodo sferico. (max 500kN)<\/td>\n<\/tr>\n<p><!-- 750 kN, 1 MN --><\/p>\n<tr>\n<td rowspan=\"3\"><strong>750 kN, 1 MN<\/strong><\/td>\n<td>CTIC60<\/td>\n<td>\u2460<\/td>\n<td><em>Loading head.<\/em><\/td>\n<td>Testa di carico.<\/td>\n<\/tr>\n<tr>\n<td>CTS96M60<\/td>\n<td>\u2461<\/td>\n<td><em>Spherical loading head M60\u00d73.<\/em><\/td>\n<td>Testa di carico sferica M60\u00d73.<\/td>\n<\/tr>\n<tr>\n<td>CPBTC4D230<\/td>\n<td>\u2462<\/td>\n<td><em>Mounting plate \u00c6 230 mm.<\/em><\/td>\n<td>Piastra base \u00c6 230 mm.<\/td>\n<\/tr>\n<p><!-- 2 MN --><\/p>\n<tr>\n<td rowspan=\"3\"><strong>2 MN<\/strong><\/td>\n<td>CTIC106\u2460<\/td>\n<td>\u2460<\/td>\n<td><em>Loading head.<\/em><\/td>\n<td>Testa di carico.<\/td>\n<\/tr>\n<tr>\n<td>TS160M100<\/td>\n<td>\u2461<\/td>\n<td><em>Spherical loading head M100\u00d73 (2MN)<\/em><\/td>\n<td>Testa di carico sferica M100\u00d73 (2MN)<\/td>\n<\/tr>\n<tr>\n<td>CPBTC4D300<\/td>\n<td>\u2462<\/td>\n<td><em>Mounting plate \u00c6 300 mm.<\/em><\/td>\n<td>Piastra base \u00c6 300 mm.<\/td>\n<\/tr>\n<p><!-- 3 MN, 5 MN --><\/p>\n<tr>\n<td rowspan=\"3\"><strong>3 MN, 5 MN<\/strong><\/td>\n<td>CTIC140<\/td>\n<td>\u2460<\/td>\n<td><em>Loading head.<\/em><\/td>\n<td>Testa di carico.<\/td>\n<\/tr>\n<tr>\n<td>CTS170M100<\/td>\n<td>\u2461<\/td>\n<td><em>Spherical loading head M100\u00d73.<\/em><\/td>\n<td>Testa di carico sferica M100\u00d73.<\/td>\n<\/tr>\n<tr>\n<td>CPBTC4D350<\/td>\n<td>\u2462<\/td>\n<td><em>Mounting plate \u00c6 350 mm.<\/em><\/td>\n<td>Piastra base \u00c6 350 mm.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Electrical connection for transducers from 2.5 kN to 1 MN<br \/>\nSTANDARD OUTPUT: PVC 105\u00b0C shielded cable, \u00d8 5.2mm with 4\u00d7 \u00d8 0.35mm2 tinned conductors. Shield connected to the body of the transducer.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-285975\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_2.png\" alt=\"\" width=\"1142\" height=\"304\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_2.png 1142w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_2-800x213.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_2-768x204.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_2-600x160.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_2-64x17.png 64w\" sizes=\"(max-width: 1142px) 100vw, 1142px\" \/><\/p>\n<p>Electrical connection for transducers from 2 MN to 5 MN<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-285977\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_3.png\" alt=\"\" width=\"1068\" height=\"330\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_3.png 1068w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_3-800x247.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_3-768x237.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_3-600x185.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4_3-64x20.png 64w\" sizes=\"(max-width: 1068px) 100vw, 1068px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Force transducer suitable for material testing machines and\u00a0<span id=\"result_box\" lang=\"en\"><span class=\"hps\">test benches<\/span>\u00a0<span class=\"hps\">in general.<br \/>\n<\/span><\/span>High mechanical resistance.<br \/>\nCompletely made of stainless steel.<br \/>\nCompletely LASER welded.<br \/>\nDegree of protection IP67.<br \/>\nLong term stability<\/p>\n","protected":false},"featured_media":285970,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5397],"product_cat":[3448],"product_tag":[5408,4959,5023,5409],"class_list":{"0":"post-285968","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-aep-transducers","7":"product_cat-force-sensor","8":"product_tag-dynamometer-2-en","9":"product_tag-force-sensor","10":"product_tag-force-sensor-en","11":"product_tag-force-transducers-en","13":"first","14":"instock","15":"taxable","16":"shipping-taxable","17":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>AEP transducers \/ TC4 \/ Force transducers - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"Force transducer suitable for material testing machines and\u00a0test benches\u00a0in general. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/product\/aep-transducers-tc4-force-transducers\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"AEP transducers \/ TC4 \/ Force transducers\" \/>\n<meta property=\"og:description\" content=\"Force transducer suitable for material testing machines and\u00a0test benches\u00a0in general. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/product\/aep-transducers-tc4-force-transducers\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-18T02:36:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4-100kN.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc4-force-transducers\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc4-force-transducers\\\/\",\"name\":\"AEP transducers \\\/ TC4 \\\/ Force transducers - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc4-force-transducers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc4-force-transducers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/TC4-100kN.webp\",\"datePublished\":\"2025-11-27T04:59:12+00:00\",\"dateModified\":\"2026-03-18T02:36:54+00:00\",\"description\":\"Force transducer suitable for material testing machines and\u00a0test benches\u00a0in general. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc4-force-transducers\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc4-force-transducers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc4-force-transducers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/TC4-100kN.webp\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/TC4-100kN.webp\",\"width\":600,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc4-force-transducers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"AEP transducers \\\/ TC4 \\\/ Force transducers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/product\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"AEP transducers \/ TC4 \/ Force transducers - CAS Scale Korea Co., Ltd.","description":"Force transducer suitable for material testing machines and\u00a0test benches\u00a0in general. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc4-force-transducers\/","og_locale":"en_US","og_type":"article","og_title":"AEP transducers \/ TC4 \/ Force transducers","og_description":"Force transducer suitable for material testing machines and\u00a0test benches\u00a0in general. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability","og_url":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc4-force-transducers\/","og_site_name":"CAS Scale Korea Co., Ltd.","article_modified_time":"2026-03-18T02:36:54+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4-100kN.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc4-force-transducers\/","url":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc4-force-transducers\/","name":"AEP transducers \/ TC4 \/ Force transducers - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc4-force-transducers\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc4-force-transducers\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4-100kN.webp","datePublished":"2025-11-27T04:59:12+00:00","dateModified":"2026-03-18T02:36:54+00:00","description":"Force transducer suitable for material testing machines and\u00a0test benches\u00a0in general. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc4-force-transducers\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/product\/aep-transducers-tc4-force-transducers\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc4-force-transducers\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4-100kN.webp","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4-100kN.webp","width":600,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc4-force-transducers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/en\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"AEP transducers \/ TC4 \/ Force transducers"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/product\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/285968","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=285968"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/285970"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=285968"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=285968"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=285968"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=285968"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}