{"id":286038,"date":"2025-11-27T16:56:56","date_gmt":"2025-11-27T07:56:56","guid":{"rendered":"https:\/\/casscale.net\/?post_type=product&#038;p=286038"},"modified":"2026-03-18T11:36:50","modified_gmt":"2026-03-18T02:36:50","slug":"aep-transducers-tc8-force-transducers","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc8-force-transducers\/","title":{"rendered":"AEP transducers \/ TC8 \/ Force transducers"},"content":{"rendered":"<h4>Force transducers for the measurement of static and dynamic loads in\u00a0<strong>COMPRESSION<\/strong>\u00a0and\u00a0<strong>TENSION<\/strong><\/h4>\n<p>Nominal Load from\u00a0<strong>10 kN<\/strong>\u00a0to\u00a0<strong>1 MN<br \/>\n<\/strong>Class (ISO 376)\u00a0<strong>0.5<\/strong>\u00a0and 1<br \/>\nLinearity and Hysteresis 0,03%<br \/>\nOutput: 2mV\/V<\/p>\n<p>On request<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-285727\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/WIRELESS-300x100.jpg\" alt=\"\" width=\"300\" height=\"100\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/WIRELESS-300x100.jpg 300w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/WIRELESS-300x100-64x21.jpg 64w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><img decoding=\"async\" class=\"alignnone size-full wp-image-285713\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/label-eac-2.jpg\" alt=\"\" width=\"150\" height=\"70\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/label-eac-2.jpg 150w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/label-eac-2-64x30.jpg 64w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Dimensions[mm]<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-286041\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC8_1.png\" alt=\"\" width=\"1009\" height=\"555\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC8_1.png 1009w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC8_1-727x400.png 727w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC8_1-768x422.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC8_1-600x330.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC8_1-64x35.png 64w\" sizes=\"(max-width: 1009px) 100vw, 1009px\" \/><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"4\">\n<thead>\n<tr>\n<th><em>CODE (Class 0.5)<\/em><\/th>\n<th><em>CODE (Class 1)<\/em><\/th>\n<th><strong>LOAD<\/strong><\/th>\n<th>\u00c6A<\/th>\n<th>B<\/th>\n<th>C<\/th>\n<th>\u00c6D<\/th>\n<th>\u00c6E<\/th>\n<th>F<\/th>\n<th>G<\/th>\n<th>n\u00b0G<\/th>\n<th>H<\/th>\n<th>T<\/th>\n<th>kHz (*)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>CTC81275KNI05<\/td>\n<td>CTC81275KNI15<\/td>\n<td>5 kN<\/td>\n<td rowspan=\"4\">127<\/td>\n<td rowspan=\"4\">110<\/td>\n<td rowspan=\"4\">35<\/td>\n<td rowspan=\"4\">92<\/td>\n<td rowspan=\"4\">47<\/td>\n<td rowspan=\"4\">M30X2<\/td>\n<td rowspan=\"4\">10.5<\/td>\n<td rowspan=\"4\">8<\/td>\n<td rowspan=\"4\">149<\/td>\n<td rowspan=\"4\">7.5<\/td>\n<td>2.5<\/td>\n<\/tr>\n<tr>\n<td>CTC812710KNI05<\/td>\n<td>CTC812710KNI15<\/td>\n<td>10 kN<\/td>\n<td>2.5<\/td>\n<\/tr>\n<tr>\n<td>CTC812725KNI05<\/td>\n<td>CTC812725KNI15<\/td>\n<td>25 kN<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>CTC812750KNI05<\/td>\n<td>CTC812750KNI15<\/td>\n<td>50 kN<\/td>\n<td>3.8<\/td>\n<\/tr>\n<tr>\n<td>CTC8165100KNI05<\/td>\n<td>CTC8165100KNI15<\/td>\n<td>100 kN<\/td>\n<td rowspan=\"3\">165<\/td>\n<td rowspan=\"3\">138<\/td>\n<td rowspan=\"3\">60<\/td>\n<td rowspan=\"3\">110<\/td>\n<td rowspan=\"3\">62<\/td>\n<td rowspan=\"3\">M42X3<\/td>\n<td rowspan=\"3\">17<\/td>\n<td rowspan=\"3\">12<\/td>\n<td rowspan=\"3\">188<\/td>\n<td rowspan=\"3\">20<\/td>\n<td rowspan=\"3\">4.0<\/td>\n<\/tr>\n<tr>\n<td>CTC8165200KNI05<\/td>\n<td>CTC8165200KNI15<\/td>\n<td>200 kN<\/td>\n<\/tr>\n<tr>\n<td>CTC8165300KNI05<\/td>\n<td>CTC8165300KNI15<\/td>\n<td>300 kN<\/td>\n<\/tr>\n<tr>\n<td>CTC8230500KNI05<\/td>\n<td>CTC8230500KNI15<\/td>\n<td>500 kN<\/td>\n<td rowspan=\"3\">230<\/td>\n<td rowspan=\"3\">185<\/td>\n<td rowspan=\"3\">80<\/td>\n<td rowspan=\"3\">147<\/td>\n<td rowspan=\"3\">96<\/td>\n<td rowspan=\"3\">M60X3<\/td>\n<td rowspan=\"3\">25<\/td>\n<td rowspan=\"3\">12<\/td>\n<td rowspan=\"3\">254<\/td>\n<td rowspan=\"3\">30<\/td>\n<td rowspan=\"3\">3.4<\/td>\n<\/tr>\n<tr>\n<td>CTC8230750KNI05<\/td>\n<td>CTC8230750KNI15<\/td>\n<td>750 kN<\/td>\n<\/tr>\n<tr>\n<td>CTC82301MNI05<\/td>\n<td>CTC82301MNI15<\/td>\n<td>1000 kN<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><sup>(*)<\/sup> Frequenza naturale \/ <em>Natural frequency.<\/em><\/p>\n<p><strong><em>Technical Data<\/em><\/strong><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"4\">\n<thead>\n<tr>\n<th>Accuracy class: ISO 376<\/th>\n<th colspan=\"2\">0.5 Compression \/ 1 Tension<\/th>\n<th colspan=\"2\">1 Compression \/ 1 Tension<\/th>\n<\/tr>\n<tr>\n<th>NOMINAL LOAD<\/th>\n<th>5-10 kN \/ 25-50 kN<\/th>\n<th colspan=\"2\">100-200 kN \/ 300 kN<\/th>\n<th>500-750 kN \/ 1000 kN<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>RELATIVE ERROR (at reading)<\/td>\n<td colspan=\"2\">\u2264\u00b10.075%(1)<\/td>\n<td colspan=\"2\">\u2264\u00b10.145%(1)<\/td>\n<\/tr>\n<tr>\n<td>b) interpolation (fc) \/ c) reversibility (u) \/ d) zero (fo)<\/td>\n<td colspan=\"2\">\u2264\u00b10.035%(1) \/ \u2264\u00b10.120%(1) \/ \u2264\u00b10.020% F.S.<\/td>\n<td colspan=\"2\">\u2264\u00b10.090%(1) \/ \u2264\u00b10.240%(1) \/ \u2264\u00b10.030% F.S.<\/td>\n<\/tr>\n<tr>\n<td>LINEARITY \/ HYSTERESIS<\/td>\n<td colspan=\"4\">\u2264\u00b10.03% F.S.<\/td>\n<\/tr>\n<tr>\n<td>TEMPERATURE EFFECT (10\u00b0C)<\/td>\n<td colspan=\"4\">on zero \u00b10.028% F.S. \/ on sensitivity \u00b10.024% F.S. \/ Effect of transverse load at 10% \u00b10.030% F.S.<\/td>\n<\/tr>\n<tr>\n<td>NOMINAL SENSITIVITY \/ SENSIVITY TOLERANCE<\/td>\n<td colspan=\"4\">2 mV\/V (2) \/ \u2264\u00b10.1% F.S.<\/td>\n<\/tr>\n<tr>\n<td>NOMINAL LOAD<\/td>\n<td colspan=\"4\">5-10-25-50-100-200-300 kN<\/td>\n<\/tr>\n<tr>\n<td>INPUT RESISTANCE<\/td>\n<td colspan=\"4\">800 \u00b1 20 \u03a9 (up to 300 kN) \/ 430 \u00b1 20 \u03a9 (500\u20131000 kN)<\/td>\n<\/tr>\n<tr>\n<td>OUTPUT RESISTANCE<\/td>\n<td colspan=\"4\">705 \u00b1 2 \u03a9 (up to 300 kN) \/ 352 \u00b1 2 \u03a9 (500\u20131000 kN)<\/td>\n<\/tr>\n<tr>\n<td>INSULATION RESISTANCE<\/td>\n<td colspan=\"4\">&gt;5 G\u03a9<\/td>\n<\/tr>\n<tr>\n<td>ZERO BALANCE \/ RECOMMENDED SUPPLY VOLTAGE<\/td>\n<td colspan=\"4\">\u2264\u00b11% F.S. \/ 10 V<\/td>\n<\/tr>\n<tr>\n<td>NOMINAL SUPPLY VOLTAGE<\/td>\n<td colspan=\"4\">1\u201315 V<\/td>\n<\/tr>\n<tr>\n<td>MAXIMUM SUPPLY VOLTAGE<\/td>\n<td colspan=\"4\">18 V<\/td>\n<\/tr>\n<tr>\n<td>MECHANICAL LIMIT VALUES REFERRED TO NOMINAL LOAD<\/td>\n<td colspan=\"4\"><\/td>\n<\/tr>\n<tr>\n<td>a) service load<\/td>\n<td colspan=\"4\">120%<\/td>\n<\/tr>\n<tr>\n<td>b) max permissible load<\/td>\n<td colspan=\"4\">150%<\/td>\n<\/tr>\n<tr>\n<td>c) breaking load<\/td>\n<td colspan=\"4\">&gt;300%<\/td>\n<\/tr>\n<tr>\n<td>d) max transverse load<\/td>\n<td colspan=\"4\">100%<\/td>\n<\/tr>\n<tr>\n<td>e) max permissible dynamic load<\/td>\n<td colspan=\"4\">75% (3)<\/td>\n<\/tr>\n<tr>\n<td>DISPLACEMENT AT NOMINAL LOAD<\/td>\n<td>~0.06 mm<\/td>\n<td colspan=\"2\">~0.17 mm<\/td>\n<td>~0.23 mm<\/td>\n<\/tr>\n<tr>\n<td>REFERENCE TEMPERATURE<\/td>\n<td colspan=\"4\">+23\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>TEMPERATURE NOMINAL RANGE<\/td>\n<td colspan=\"4\">-10\/+40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>SERVICE TEMPERATURE<\/td>\n<td colspan=\"4\">-10\/+70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>STORAGE TEMPERATURE<\/td>\n<td colspan=\"4\">-20\/+80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>WEIGHT<\/td>\n<td>~2.45 kg<\/td>\n<td colspan=\"2\">~5.80 kg<\/td>\n<td>~16.5 kg<\/td>\n<\/tr>\n<tr>\n<td>PROTECTION CLASS \/ EXECUTION MATERIAL<\/td>\n<td colspan=\"4\">IP67 \/ Stainless Steel<\/td>\n<\/tr>\n<tr>\n<td>CABLE LENGTH AND DIAMETER<\/td>\n<td>5m \u00d85.2<\/td>\n<td colspan=\"3\">5m \u00d86.4<\/td>\n<\/tr>\n<tr>\n<td>FIXING SCREWS<\/td>\n<td colspan=\"4\"><\/td>\n<\/tr>\n<tr>\n<td>a) diameter<\/td>\n<td>M10<\/td>\n<td colspan=\"2\">M16<\/td>\n<td>M24<\/td>\n<\/tr>\n<tr>\n<td>b) resistance class<\/td>\n<td>12.9<\/td>\n<td colspan=\"2\">12.9<\/td>\n<td>12.9<\/td>\n<\/tr>\n<tr>\n<td>c) tightening torque<\/td>\n<td>70 Nm<\/td>\n<td colspan=\"2\">368 Nm<\/td>\n<td>460 Nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><sup>(1)<\/sup><\/strong><em>Percentage errors referred to reading, min. 1\/10 of nominal load.<br \/>\n<\/em><strong><sup>(2)<\/sup>\u00a0<\/strong><em>Tests and calibrations performed in <strong>COMPRESSION <\/strong>with the transducer mounted on a bearing support with correctly tightened clamping screws.<br \/>\n<\/em><strong><sup>(3)<\/sup>\u00a0<\/strong><em>The dynamic load must be applied to the transducer central thread and not to the external fixing rim.<br \/>\n<\/em><em>kg calibration on request<br \/>\n<\/em><em>Classifications according <strong>ASTM E74 <\/strong>on request<\/em><em>.<\/em><\/p>\n<p><strong><em>Electrical connection<br \/>\n<\/em><\/strong><\/p>\n<p><strong><em>STANDARD OUTPUT<\/em><\/strong><em>: PVC 105\u00b0C shielded cable with 4\u00d7 \u00d8 0.35mm\u00b2 tinned conductors.<\/em><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-286043\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC8_2.png\" alt=\"\" width=\"1170\" height=\"319\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC8_2.png 1170w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC8_2-800x218.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC8_2-768x209.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC8_2-600x164.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC8_2-64x17.png 64w\" sizes=\"(max-width: 1170px) 100vw, 1170px\" \/><\/p>\n<p><em>Shield <\/em>c<em>onnected to the body of the transducer.<\/em><\/p>\n<p><strong>Dimensions[mm]<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>TC8<\/th>\n<th>A<\/th>\n<th>B<\/th>\n<th>C<\/th>\n<th>D<\/th>\n<th>E<\/th>\n<th>F<\/th>\n<th>G<\/th>\n<th>H<\/th>\n<th>L<\/th>\n<th>M<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>5, 10, 25, 50 kN<\/td>\n<td>108<\/td>\n<td>37<\/td>\n<td>35<\/td>\n<td>36<\/td>\n<td>\u00d876<\/td>\n<td>\u00d8127<\/td>\n<td>\u00d8100<\/td>\n<td>M30 \u00d7 2<\/td>\n<td>\u00d847<\/td>\n<td>~200<\/td>\n<\/tr>\n<tr>\n<td>100, 200, 300 kN<\/td>\n<td>179<\/td>\n<td>60<\/td>\n<td>60<\/td>\n<td>59<\/td>\n<td>\u00d876<\/td>\n<td>\u00d8165<\/td>\n<td>\u00d8100<\/td>\n<td>M42 \u00d7 3<\/td>\n<td>\u00d862<\/td>\n<td>~224<\/td>\n<\/tr>\n<tr>\n<td>500, 750, 1000 kN<\/td>\n<td>252<\/td>\n<td>85<\/td>\n<td>80<\/td>\n<td>87<\/td>\n<td>\u00d8126<\/td>\n<td>\u00d8230<\/td>\n<td>\u00d8180<\/td>\n<td>M60 \u00d7 3<\/td>\n<td>\u00d896<\/td>\n<td>\/<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><em>\u00a0<\/em><\/strong><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Force transducer suitable for material testing machines and\u00a0<span id=\"result_box\" lang=\"en\"><span class=\"hps\">test benches<\/span>\u00a0<span class=\"hps\">in general.<br \/>\n<\/span><\/span>High mechanical resistance.<br \/>\nCompletely made of stainless steel.<br \/>\nCompletely LASER welded.<br \/>\nDegree of protection IP67.<br \/>\nLong term stability.<\/p>\n","protected":false},"featured_media":286046,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5397],"product_cat":[3448],"product_tag":[5408,4959,5023,5409],"class_list":{"0":"post-286038","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-aep-transducers","7":"product_cat-force-sensor","8":"product_tag-dynamometer-2-en","9":"product_tag-force-sensor","10":"product_tag-force-sensor-en","11":"product_tag-force-transducers-en","13":"first","14":"instock","15":"taxable","16":"shipping-taxable","17":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>AEP transducers \/ TC8 \/ Force transducers - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"Force transducer suitable for material testing machines and\u00a0test benches\u00a0in general. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/product\/aep-transducers-tc8-force-transducers\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"AEP transducers \/ TC8 \/ Force transducers\" \/>\n<meta property=\"og:description\" content=\"Force transducer suitable for material testing machines and\u00a0test benches\u00a0in general. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/product\/aep-transducers-tc8-force-transducers\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-18T02:36:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4-100kN-3.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc8-force-transducers\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc8-force-transducers\\\/\",\"name\":\"AEP transducers \\\/ TC8 \\\/ Force transducers - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc8-force-transducers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc8-force-transducers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/TC4-100kN-3.webp\",\"datePublished\":\"2025-11-27T07:56:56+00:00\",\"dateModified\":\"2026-03-18T02:36:50+00:00\",\"description\":\"Force transducer suitable for material testing machines and\u00a0test benches\u00a0in general. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc8-force-transducers\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc8-force-transducers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc8-force-transducers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/TC4-100kN-3.webp\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/TC4-100kN-3.webp\",\"width\":600,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/aep-transducers-tc8-force-transducers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"AEP transducers \\\/ TC8 \\\/ Force transducers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/product\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"AEP transducers \/ TC8 \/ Force transducers - CAS Scale Korea Co., Ltd.","description":"Force transducer suitable for material testing machines and\u00a0test benches\u00a0in general. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc8-force-transducers\/","og_locale":"en_US","og_type":"article","og_title":"AEP transducers \/ TC8 \/ Force transducers","og_description":"Force transducer suitable for material testing machines and\u00a0test benches\u00a0in general. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability.","og_url":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc8-force-transducers\/","og_site_name":"CAS Scale Korea Co., Ltd.","article_modified_time":"2026-03-18T02:36:50+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4-100kN-3.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc8-force-transducers\/","url":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc8-force-transducers\/","name":"AEP transducers \/ TC8 \/ Force transducers - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc8-force-transducers\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc8-force-transducers\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4-100kN-3.webp","datePublished":"2025-11-27T07:56:56+00:00","dateModified":"2026-03-18T02:36:50+00:00","description":"Force transducer suitable for material testing machines and\u00a0test benches\u00a0in general. High mechanical resistance. Completely made of stainless steel. Completely LASER welded. Degree of protection IP67. Long term stability.","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc8-force-transducers\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/product\/aep-transducers-tc8-force-transducers\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc8-force-transducers\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4-100kN-3.webp","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/TC4-100kN-3.webp","width":600,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/product\/aep-transducers-tc8-force-transducers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"AEP transducers \/ TC8 \/ Force transducers"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/product\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/286038","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=286038"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/286046"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=286038"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=286038"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=286038"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=286038"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}