{"id":286065,"date":"2025-11-28T09:00:57","date_gmt":"2025-11-28T00:00:57","guid":{"rendered":"https:\/\/casscale.net\/?post_type=product&#038;p=286065"},"modified":"2026-03-18T11:36:20","modified_gmt":"2026-03-18T02:36:20","slug":"aep-transducers-c10-amp-amplified-force-transducers","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/aep-transducers-c10-amp-amplified-force-transducers\/","title":{"rendered":"AEP transducers \/ C10-AMP \/ Amplified Force transducers"},"content":{"rendered":"<h4>Force transducers for the measurement of static and dynamic loads in\u00a0<strong>COMPRESSION<\/strong>\u00a0an\u00a0<strong>TENSION<\/strong><\/h4>\n<p>Nominal Load from\u00a0<strong>10 kN<\/strong>\u00a0to\u00a0<strong>1 MN<br \/>\n<\/strong>Linearity and Hysteresis 0,10% and 0,20%<br \/>\nStandard Output<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-285711\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/amp.jpg\" alt=\"\" width=\"693\" height=\"77\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/amp.jpg 1062w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/amp-800x89.jpg 800w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/amp-768x85.jpg 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/amp-600x67.jpg 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/amp-64x7.jpg 64w\" sizes=\"(max-width: 693px) 100vw, 693px\" \/><img decoding=\"async\" class=\"alignnone size-full wp-image-285713\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/label-eac-2.jpg\" alt=\"\" width=\"150\" height=\"70\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/label-eac-2.jpg 150w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/label-eac-2-64x30.jpg 64w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Dimensions[mm]<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-286049\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10_1.png\" alt=\"\" width=\"1464\" height=\"818\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10_1.png 1464w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10_1-716x400.png 716w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10_1-1400x782.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10_1-768x429.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10_1-600x335.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10_1-64x36.png 64w\" sizes=\"(max-width: 1464px) 100vw, 1464px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-286051\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10_2.png\" alt=\"\" width=\"607\" height=\"726\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10_2.png 607w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10_2-334x400.png 334w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10_2-600x718.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10_2-64x77.png 64w\" sizes=\"(max-width: 607px) 100vw, 607px\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>LOAD<\/th>\n<th>CODE<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>10 kN<\/td>\n<td>CC1014010KNI15<\/td>\n<\/tr>\n<tr>\n<td>25 kN<\/td>\n<td>CC1014025KNI15<\/td>\n<\/tr>\n<tr>\n<td>50 kN<\/td>\n<td>CC1014050KNI15<\/td>\n<\/tr>\n<tr>\n<td>100 kN<\/td>\n<td>CC10140100KNI15<\/td>\n<\/tr>\n<tr>\n<td>250 kN<\/td>\n<td>CC10165250KNI15<\/td>\n<\/tr>\n<tr>\n<td>500 kN<\/td>\n<td>CC10165500KNI15<\/td>\n<\/tr>\n<tr>\n<td>750 kN<\/td>\n<td>CC10200750KNI15<\/td>\n<\/tr>\n<tr>\n<td>1000 kN<\/td>\n<td>CC102001MNI15<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>IMPORTANT<\/strong> <strong>NOTE: <\/strong><em>The contact surfaces with force transducer must have a hardness HRC <\/em><em>\u00b3<\/em> <em>40 and a roughness Ra \u22641.6<\/em><\/p>\n<p><strong>Technical Data<\/strong><\/p>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<tbody>\n<tr>\n<th width=\"200\">ITEM<\/th>\n<th width=\"100\">10\u201325\u201350 kN<br \/>\n100 kN<\/th>\n<th width=\"120\">250\u2013500 kN<\/th>\n<th width=\"120\">750\u20131000 kN<\/th>\n<\/tr>\n<tr>\n<td><em>NOMINAL LOAD<\/em><\/td>\n<td>10\u201325\u201350 kN<br \/>\n100 kN<\/td>\n<td>250\u2013500 kN<\/td>\n<td>750\u20131000 kN<\/td>\n<\/tr>\n<tr>\n<td><em>LINEARITY<\/em><\/td>\n<td>\u2264 \u00b10.10% F.S.<\/td>\n<td colspan=\"2\">\u2264 \u00b10.20% F.S.<\/td>\n<\/tr>\n<tr>\n<td>AMPLIFIED OUTPUT<br \/>\n<em>Sensitivity Tolerance<\/em><\/td>\n<td colspan=\"3\">4\u201320 mA (3 wires), \u00b15 V, \u00b110 V<br \/>\n&lt; \u00b10.1%<\/td>\n<\/tr>\n<tr>\n<td><em>NOMINAL POWER SUPPLY<\/em><\/td>\n<td colspan=\"3\">\u00b15 V \u2192 12\u201328 Vdc<br \/>\n4\u201320 mA &amp; \u00b110 V \u2192 18\u201328 Vdc<\/td>\n<\/tr>\n<tr>\n<td>MAX. ABSORPTION<br \/>\nLOADING RESISTANCE<br \/>\na) tension<br \/>\nb) current<br \/>\nRESPONSE FREQUENCY<\/td>\n<td colspan=\"3\">30 mA<\/p>\n<p>Min. 3 k\u03a9 (tension)<br \/>\n0\u2013470 \u03a9 (current)<br \/>\n~2 kHz<\/td>\n<\/tr>\n<tr>\n<td><em>TEMPERATURE EFFECT (10\u00b0C)<\/em><br \/>\na) Zero<br \/>\nb) Sensitivity<\/td>\n<td colspan=\"3\">\n\u2264 \u00b10.028% F.S.<br \/>\n\u2264 \u00b10.024% F.S.<\/td>\n<\/tr>\n<tr>\n<td>REFERENCE\u00a0 TEMPERATURE<br \/>\nTEMPERATURE NOMINAL RANGE<br \/>\nSERVICE TEMPERATURE RANGE<br \/>\nSTORAGE TEMPERATURE RANGE<\/td>\n<td colspan=\"3\">+23\u00b0C<br \/>\n\u201310 ~ +40\u00b0C<br \/>\n\u201310 ~ +70\u00b0C<br \/>\n\u201320 ~ +80\u00b0C<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\"><em>MECHANICAL LIMIT VALUES<\/em><br \/>\na) Service load<br \/>\nb) Max permissible load<br \/>\nc) Breaking load<br \/>\nd) Max transverse load<br \/>\ne) Max dynamic load<br \/>\nDISPLACEMENT AT NOMINAL LOAD<\/td>\n<td colspan=\"3\">\n120%<br \/>\n150%<br \/>\n&gt;300%<br \/>\n100%<br \/>\n75%<\/td>\n<\/tr>\n<tr>\n<td>~0.17 mm<\/td>\n<td>~0.20 mm<\/td>\n<td>~0.25 mm<\/td>\n<\/tr>\n<tr>\n<td><em>WEIGHT<\/em><\/td>\n<td>~4.1 kg<\/td>\n<td>~5.5 kg<\/td>\n<td>~8.3 kg<\/td>\n<\/tr>\n<tr>\n<td><em>PROTECTION CLASS (EN 60529)<br \/>\nEXECUTION MATERIAL<br \/>\n<\/em><\/td>\n<td colspan=\"3\">IP67<br \/>\nStainless Steel<\/td>\n<\/tr>\n<tr>\n<td><em>CABLE OUTPUT<\/em><\/td>\n<td colspan=\"3\">5 m<br \/>\nPVC 105\u00b0C shielded cable \u00d85.3 mm<br \/>\n4 \u00d7 tinned \u00d80.14 mm\u00b2 conductors<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>kg calibration on request.<\/em><\/p>\n<p><strong><em>Electrical Connections<\/em><\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-286066\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10-AMP_4.png\" alt=\"\" width=\"1323\" height=\"401\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10-AMP_4.png 1323w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10-AMP_4-800x242.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10-AMP_4-768x233.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10-AMP_4-600x182.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/11\/C10-AMP_4-64x19.png 64w\" sizes=\"(max-width: 1323px) 100vw, 1323px\" \/><\/p>\n<p><em>Shield connected to the transducers body.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p><span id=\"result_box\" class=\"short_text\" lang=\"en\">Force transducer suitable for material testing machines and \u00a0<span id=\"result_box\" lang=\"en\"><span class=\"hps\">test benches<\/span>\u00a0<span class=\"hps\">in general.<\/span><\/span><\/span><br \/>\nHigh mechanical resistance.<br \/>\nCompletely made of stainless steel.<br \/>\nCompletely LASER welded.<br \/>\nDegree of protection IP67.<br \/>\nLong term stability.<\/p>\n","protected":false},"featured_media":286056,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5397],"product_cat":[3448],"product_tag":[5408,4959,5023,5409],"class_list":{"0":"post-286065","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-aep-transducers","7":"product_cat-force-sensor","8":"product_tag-dynamometer-2-en","9":"product_tag-force-sensor","10":"product_tag-force-sensor-en","11":"product_tag-force-transducers-en","13":"first","14":"instock","15":"taxable","16":"shipping-taxable","17":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/286065","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=286065"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/286056"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=286065"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=286065"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=286065"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=286065"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}