{"id":286389,"date":"2025-12-01T15:55:08","date_gmt":"2025-12-01T06:55:08","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/schenck-process-rtn-ring-torsion-load-cell\/"},"modified":"2026-04-09T09:06:16","modified_gmt":"2026-04-09T00:06:16","slug":"schenck-process-rtn-ring-torsion-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/schenck-process-rtn-ring-torsion-load-cell\/","title":{"rendered":"Schenck Process \/ RTN \/ Ring Torsion Load Cell"},"content":{"rendered":"<div>\n<h4 class=\"page-title\">Ring Torsion Load Cell RTN 1 t \u2026470 t<\/h4>\n<\/div>\n<div><strong>Application<\/strong><br \/>\nAs a measuring transducer, the load cell converts the mechanical input variable &#8216;force&#8217; proportionally into the electrical output variable &#8216;voltage&#8217;.<br \/>\nThe consistent optimization of the ring torsion load cell offers the user specific advantages:<br \/>\n\u25aa The extremely small frame size simplifies the use in almost all weighing device applications<br \/>\n\u25aa The durable design allows easy transportation, installation and operation, even in very rough ambient conditions (disturbing forces, temperature)<\/div>\n<div>\u00a0<\/div>\n<div><strong>Construction<\/strong><br \/>\n\u25aa Hermetically sealed encapsulation through laser welding(IP68)<br \/>\n\u25aa High corrosion protection thanks to electrolytically polished stainless steel<br \/>\n\u25aa All electrical components are located inside the load cell and thus are optimally protected<br \/>\n\u25aa The high quality and robust connecting cable is guided radially into the load cell<br \/>\n\u25aa In combination with adapter kits, the RTN load cells are compatible with former designs.<\/div>\n<div>\u00a0<\/div>\n<div><strong>Function<\/strong><br \/>\n\u25aa High measuring sensitivity<br \/>\n\u25aa High reproducibility<br \/>\n\u25aa High long-term stability and therefore consistently high accuracy permanently<br \/>\n\u25aa Extremely small measured value influence as a result of lateral forces<br \/>\n\u25aa High functional safety, even with frequently unavoidable impact loads and constraining forces, as well as with electrical interferences<br \/>\n\u25aa Integrated overvoltage protection<br \/>\n\u25aa Torque-free force input\/output as a result of the direct, vertical power train<br \/>\n\u25aa Plug variants for fast and inexpensive replacement of damaged cables<\/div>\n<div>\u00a0<\/div>\n<div class=\"product attribute sku\"><strong>Dimensions and basic data<\/strong><\/div>\n<div><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-286376\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/12\/rtn_5.png\" alt=\"\" width=\"1095\" height=\"740\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/12\/rtn_5.png 1095w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/12\/rtn_5-592x400.png 592w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/12\/rtn_5-768x519.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/12\/rtn_5-600x405.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2025\/12\/rtn_5-64x43.png 64w\" sizes=\"(max-width: 1095px) 100vw, 1095px\" \/><\/div>\n<div>View A<\/div>\n<div>\n<table>\n<tbody>\n<tr>\n<td width=\"52\"><strong>RTN<\/strong><strong>(Type)<\/strong><\/td>\n<td width=\"42\"><strong>A<\/strong><strong>(mm)<\/strong><\/td>\n<td width=\"44\"><strong>B<\/strong><strong>(mm)<\/strong><\/td>\n<td width=\"44\"><strong>C<\/strong><strong>(mm)<\/strong><\/td>\n<td width=\"35\"><strong>D<\/strong><strong>(mm)<\/strong><\/td>\n<td width=\"53\"><strong>H<\/strong><strong>(mm)<\/strong><\/td>\n<td width=\"44\"><strong>K<\/strong><strong>(mm)<\/strong><\/td>\n<td width=\"61\"><strong>Nominal<\/strong> <strong>load E<sub>max<\/sub><\/strong><strong>(t)<\/strong><\/td>\n<td width=\"53\"><strong>Limit load L<sub>l<\/sub><\/strong><strong>(t)<\/strong><\/td>\n<td width=\"53\"><strong>Breaking<\/strong> <strong>load L<sub>d<\/sub><\/strong><strong>(t)<\/strong><\/td>\n<td width=\"70\"><strong>Nominal<\/strong> <strong>measuring<\/strong> <strong>path h<sub>n<\/sub><\/strong><strong>(mm)<\/strong><\/td>\n<td width=\"66\"><strong>Dead load(kg)<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"52\">1 t<\/td>\n<td width=\"42\">49<\/td>\n<td width=\"44\">20<\/td>\n<td width=\"44\">60<\/td>\n<td width=\"35\">53<\/td>\n<td width=\"53\">43<\/td>\n<td width=\"44\">7.5<\/td>\n<td width=\"61\">1<\/td>\n<td width=\"53\">1.7<\/td>\n<td width=\"53\">4<\/td>\n<td width=\"70\">0.13<\/td>\n<td width=\"66\">0.6<\/td>\n<\/tr>\n<tr>\n<td width=\"52\">2.2 t<\/td>\n<td width=\"42\">49<\/td>\n<td width=\"44\">20<\/td>\n<td width=\"44\">60<\/td>\n<td width=\"35\">53<\/td>\n<td width=\"53\">43<\/td>\n<td width=\"44\">7.5<\/td>\n<td width=\"61\">2.2<\/td>\n<td width=\"53\">4<\/td>\n<td width=\"53\">9<\/td>\n<td width=\"70\">0.12<\/td>\n<td width=\"66\">0.6<\/td>\n<\/tr>\n<tr>\n<td width=\"52\">4.7 t<\/td>\n<td width=\"42\">49<\/td>\n<td width=\"44\">20<\/td>\n<td width=\"44\">60<\/td>\n<td width=\"35\">53<\/td>\n<td width=\"53\">43<\/td>\n<td width=\"44\">7.5<\/td>\n<td width=\"61\">4.7<\/td>\n<td width=\"53\">8<\/td>\n<td width=\"53\">19<\/td>\n<td width=\"70\">0.12<\/td>\n<td width=\"66\">0.7<\/td>\n<\/tr>\n<tr>\n<td width=\"52\">10 t<\/td>\n<td width=\"42\">73<\/td>\n<td width=\"44\">30<\/td>\n<td width=\"44\">75<\/td>\n<td width=\"35\">&#8211;<\/td>\n<td width=\"53\">50<\/td>\n<td width=\"44\">6.5<\/td>\n<td width=\"61\">10<\/td>\n<td width=\"53\">17<\/td>\n<td width=\"53\">40<\/td>\n<td width=\"70\">0.17<\/td>\n<td width=\"66\">1.2<\/td>\n<\/tr>\n<tr>\n<td width=\"52\">15 t<\/td>\n<td width=\"42\">75<\/td>\n<td width=\"44\">30<\/td>\n<td width=\"44\">75<\/td>\n<td width=\"35\">&#8211;<\/td>\n<td width=\"53\">50<\/td>\n<td width=\"44\">6.5<\/td>\n<td width=\"61\">15<\/td>\n<td width=\"53\">28<\/td>\n<td width=\"53\">60<\/td>\n<td width=\"70\">0.18<\/td>\n<td width=\"66\">1.3<\/td>\n<\/tr>\n<tr>\n<td width=\"52\">22 t<\/td>\n<td width=\"42\">75<\/td>\n<td width=\"44\">30<\/td>\n<td width=\"44\">75<\/td>\n<td width=\"35\">&#8211;<\/td>\n<td width=\"53\">50<\/td>\n<td width=\"44\">6.5<\/td>\n<td width=\"61\">22<\/td>\n<td width=\"53\">38<\/td>\n<td width=\"53\">90<\/td>\n<td width=\"70\">0.21<\/td>\n<td width=\"66\">1.3<\/td>\n<\/tr>\n<tr>\n<td width=\"52\">33 t<\/td>\n<td width=\"42\">95<\/td>\n<td width=\"44\">40<\/td>\n<td width=\"44\">95<\/td>\n<td width=\"35\">&#8211;<\/td>\n<td width=\"53\">65<\/td>\n<td width=\"44\">10<\/td>\n<td width=\"61\">33<\/td>\n<td width=\"53\">58<\/td>\n<td width=\"53\">130<\/td>\n<td width=\"70\">0.25<\/td>\n<td width=\"66\">2.1<\/td>\n<\/tr>\n<tr>\n<td width=\"52\">47 t<\/td>\n<td width=\"42\">130<\/td>\n<td width=\"44\">60<\/td>\n<td width=\"44\">130<\/td>\n<td width=\"35\">&#8211;<\/td>\n<td width=\"53\">75<\/td>\n<td width=\"44\">14<\/td>\n<td width=\"61\">47<\/td>\n<td width=\"53\">80<\/td>\n<td width=\"53\">190<\/td>\n<td width=\"70\">0.33<\/td>\n<td width=\"66\">4.3<\/td>\n<\/tr>\n<tr>\n<td width=\"52\">68 t<\/td>\n<td width=\"42\">130<\/td>\n<td width=\"44\">60<\/td>\n<td width=\"44\">130<\/td>\n<td width=\"35\">&#8211;<\/td>\n<td width=\"53\">85<\/td>\n<td width=\"44\">14<\/td>\n<td width=\"61\">68<\/td>\n<td width=\"53\">120<\/td>\n<td width=\"53\">270<\/td>\n<td width=\"70\">0.35<\/td>\n<td width=\"66\">4.8<\/td>\n<\/tr>\n<tr>\n<td width=\"52\">100 t<\/td>\n<td width=\"42\">150<\/td>\n<td width=\"44\">70<\/td>\n<td width=\"44\">150<\/td>\n<td width=\"35\">&#8211;<\/td>\n<td width=\"53\">90<\/td>\n<td width=\"44\">16<\/td>\n<td width=\"61\">100<\/td>\n<td width=\"53\">170<\/td>\n<td width=\"53\">400<\/td>\n<td width=\"70\">0.45<\/td>\n<td width=\"66\">7.0<\/td>\n<\/tr>\n<tr>\n<td width=\"52\">150 t<\/td>\n<td width=\"42\">150<\/td>\n<td width=\"44\">70<\/td>\n<td width=\"44\">150<\/td>\n<td width=\"35\">&#8211;<\/td>\n<td width=\"53\">100<\/td>\n<td width=\"44\">16<\/td>\n<td width=\"61\">150<\/td>\n<td width=\"53\">250<\/td>\n<td width=\"53\">600<\/td>\n<td width=\"70\">0.57<\/td>\n<td width=\"66\">8.6<\/td>\n<\/tr>\n<tr>\n<td width=\"52\">220 t<\/td>\n<td width=\"42\">225<\/td>\n<td width=\"44\">100<\/td>\n<td width=\"44\">225<\/td>\n<td width=\"35\">&#8211;<\/td>\n<td width=\"53\">130<\/td>\n<td width=\"44\">24<\/td>\n<td width=\"61\">220<\/td>\n<td width=\"53\">380<\/td>\n<td width=\"53\">900<\/td>\n<td width=\"70\">0.67<\/td>\n<td width=\"66\">22.0<\/td>\n<\/tr>\n<tr>\n<td width=\"52\">330 t<\/td>\n<td width=\"42\">225<\/td>\n<td width=\"44\">100<\/td>\n<td width=\"44\">225<\/td>\n<td width=\"35\">&#8211;<\/td>\n<td width=\"53\">145<\/td>\n<td width=\"44\">24<\/td>\n<td width=\"61\">330<\/td>\n<td width=\"53\">580<\/td>\n<td width=\"53\">1200<\/td>\n<td width=\"70\">0.85<\/td>\n<td width=\"66\">29.0<\/td>\n<\/tr>\n<tr>\n<td width=\"52\">470 t<\/td>\n<td width=\"42\">270<\/td>\n<td width=\"44\">120<\/td>\n<td width=\"44\">270<\/td>\n<td width=\"35\">&#8211;<\/td>\n<td width=\"53\">170<\/td>\n<td width=\"44\">28<\/td>\n<td width=\"61\">470<\/td>\n<td width=\"53\">700<\/td>\n<td width=\"53\">1500<\/td>\n<td width=\"70\">1.00<\/td>\n<td width=\"66\">50.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div>\u00a0<\/div>\n<div>Allowed static transverse load Lq = 0.5 (E<sub>max<\/sub> \u2013 0.8 L<sub>z<\/sub>), however maximum L<sub>qmax<\/sub> = 0.2 L<sub>z<\/sub>; E<sub>max<\/sub> = nominal load; L<sub>z<\/sub> = Load in measuring direction. Allowed vibration stress acc. to DIN 50100: 70 % E<sub>max<\/sub>. Here, the peak load value E<sub>max<\/sub> may not be exceeded.<br \/>\nIn combination with elastomer bearings, SEM must be observed that the reset force of the elastomer bearings of the self-aligning bearings already represents a transverse force.<\/div>\n<div>\u00a0<\/div>\n<div>\n<p><strong><span lang=\"EN-US\" style=\"color: #231f20;\">Technical <span style=\"letter-spacing: -.2pt;\">data<br \/>\n<\/span><\/span><\/strong><span lang=\"EN-US\" style=\"color: #231f20;\">Load <span style=\"letter-spacing: -.2pt;\">cell<br \/>\n<\/span><\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><strong>Nominal load<\/strong><\/td>\n<td><strong>E<\/strong><sub>max<\/sub><\/td>\n<td colspan=\"2\"><strong>1 t \u2013 470 t<\/strong><\/td>\n<td colspan=\"2\"><strong>1 t \u2013 100 t<\/strong><\/td>\n<td><strong>\u2014<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Accuracy class<\/strong><\/td>\n<td>\u2014<\/td>\n<td>0.05<\/td>\n<td>C3<\/td>\n<td colspan=\"2\">C5 \/ C4 Mi 7.5<\/td>\n<td>Ref<\/td>\n<\/tr>\n<tr>\n<td><strong>Nominal characteristic value<\/strong><\/td>\n<td>C<sub>n<\/sub><\/td>\n<td colspan=\"4\">2.85 mV\/V \u00b12.85 \u03bcV\/V<\/td>\n<td>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td><strong>Combined<\/strong> <strong>error<\/strong><\/td>\n<td>F<sub>comb<\/sub><\/td>\n<td>0.05 %<\/td>\n<td>0.02 %<\/td>\n<td colspan=\"2\">0.01 %<\/td>\n<td>C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td><strong>Return to zero signal after load (30 min)<\/strong><\/td>\n<td>F<sub>dr<\/sub><\/td>\n<td>\u00b10.03 %<\/td>\n<td>\u00b10.016 %<\/td>\n<td colspan=\"2\">\u00b10.006 %<\/td>\n<td>C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td><strong>Creepage under load (30 min)<\/strong><\/td>\n<td>F<sub>cr<\/sub><\/td>\n<td>\u00b10.04 %<\/td>\n<td>\u00b10.024 %<\/td>\n<td colspan=\"2\">\u00b10.009 %<\/td>\n<td>C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td><strong>Temperature coefficient of the zero signal per 10 K<\/strong><\/td>\n<td>TK<sub>0<\/sub><\/td>\n<td>\u00b10.03 %<br \/>\n\u00b10.05 %<\/td>\n<td>\u00b10.007 %<br \/>\n\u00b10.02 %<\/td>\n<td colspan=\"2\">\u00b10.0058 %<br \/>\n\u00b10.02 %<\/td>\n<td>C<sub>n<\/sub>, B<sub>tn<br \/>\n<\/sub>C<sub>n<\/sub>, B<sub>tu<\/sub><\/td>\n<\/tr>\n<tr>\n<td><strong>Temperature coefficient of the character- istic value per 10 K<\/strong><\/td>\n<td>TK<sub>c<\/sub><\/td>\n<td>\u00b10.05 %<br \/>\n\u00b10.07 %<\/td>\n<td>\u00b10.008 %<br \/>\n\u00b10.02 %<\/td>\n<td colspan=\"2\">\u00b10.0062 %<br \/>\n\u00b10.02 %<\/td>\n<td>C<sub>n<\/sub>, B<sub>tn<br \/>\n<\/sub>C<sub>n<\/sub>, B<sub>tu<\/sub><\/td>\n<\/tr>\n<tr>\n<td><strong>Max. allowed number of verifiable divi- sion values<\/strong><\/td>\n<td>n<sub>LC<\/sub><\/td>\n<td>\u2014<\/td>\n<td>3000<\/td>\n<td colspan=\"2\">5000<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td><strong>For multi-divisional scales<\/strong><\/td>\n<td>Z<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td colspan=\"2\">7500<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td><strong>Minimum division value OIML<\/strong><\/td>\n<td>V<sub>min<\/sub><\/td>\n<td>\u2014<\/td>\n<td>E<sub>max<\/sub>\/20000 E<sub>max<\/sub>\/10000 (1 t)<\/td>\n<td colspan=\"2\">E<sub>max<\/sub>\/24000 E<sub>max<\/sub>\/20000 (2.2 t)<br \/>\nE<sub>max<\/sub>\/10000 (1 t)<\/td>\n<td>\n<p><strong>\u00a0<\/strong><\/p>\n<p>\u2014<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><strong>Minimum division value NTEP<\/strong><\/td>\n<td>V<sub>min<\/sub><\/td>\n<td colspan=\"4\">E<sub>max<\/sub>\/14000<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td><strong>Max. application range<\/strong><\/td>\n<td>B<sub>amax<\/sub><\/td>\n<td colspan=\"4\">B<sub>amax<\/sub> = E<sub>max<\/sub><\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td><strong>Input resistance<\/strong><\/td>\n<td>R<sub>e<\/sub><\/td>\n<td colspan=\"4\">4450 \u03a9 \u00b1100 \u03a9<\/td>\n<td>T<sub>r<\/sub><\/td>\n<\/tr>\n<tr>\n<td><strong>Output resistance<\/strong><\/td>\n<td>R<sub>a<\/sub><\/td>\n<td>4010 \u03a9 \u00b12 \u03a9<\/td>\n<td colspan=\"3\">4010 \u03a9 \u00b10.5 \u03a9<\/td>\n<td>T<sub>r<\/sub><\/td>\n<\/tr>\n<tr>\n<td><strong>Zero Signal<\/strong><\/td>\n<td>S<sub>0<\/sub><\/td>\n<td colspan=\"4\">\u00b11 %<\/td>\n<td>C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td><strong>Max. supply voltage<\/strong><\/td>\n<td>U<sub>smax<\/sub><\/td>\n<td colspan=\"4\">60 V<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td><strong>Nominal temperature range (relevant for legal-for-trade)<\/strong><\/td>\n<td>B<sub>tn<\/sub><\/td>\n<td colspan=\"4\">-10 \u00b0C \u2026 +40 \u00b0C<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td><strong>Reference temperature<\/strong><\/td>\n<td>T<sub>r<\/sub><\/td>\n<td colspan=\"4\">22 \u00b0C<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td><strong>Operating temperature range<\/strong><\/td>\n<td>B<sub>tu<\/sub><\/td>\n<td colspan=\"3\">-40 \u00b0C \u2026 +80 \u00b0C<br \/>\n-25 \u00b0C \u2026 +80 \u00b0C<br \/>\n(Plug optional) Optional up to +110 \u00b0C <sup>1)<\/sup><\/td>\n<td>-40 \u00b0C \u2026 +80 \u00b0C<br \/>\n-25 \u00b0C \u2026 +80 \u00b0C<br \/>\n(Plug optional)<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td><strong>Storage temperature range<\/strong><\/td>\n<td>B<sub>ts<\/sub><\/td>\n<td colspan=\"4\">-50 \u00b0C \u2026 +85 \u00b0C<br \/>\n-25 \u00b0C \u2026 +85 \u00b0C (plug optional)<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td><strong>Type of protection<\/strong><\/td>\n<td>\u2014<\/td>\n<td colspan=\"3\">IP68, 1 m \/ 100 h<br \/>\nOptional up to 110 \u00b0C: IP66<\/td>\n<td>IP68, 1 m \/ 100 h<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td><strong>Material<\/strong><\/td>\n<td>\u2014<\/td>\n<td colspan=\"4\">Stainless steel<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td><strong>Corrosion protection<\/strong><\/td>\n<td>\u2014<\/td>\n<td colspan=\"4\">For details, see data sheet DDP8483<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span lang=\"EN-US\" style=\"color: #231f20; letter-spacing: -.1pt;\">Cables<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><strong>Type<\/strong><\/td>\n<td>&nbsp;<\/td>\n<td><strong>Firmly connected<\/strong><\/td>\n<td><strong>Connecting cable (not available in ATEX)<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Nominal load<\/strong><\/td>\n<td>E<sub>max<\/sub><\/td>\n<td>1 \u2013 470<\/td>\n<td>1 \u2013 150<\/td>\n<\/tr>\n<tr>\n<td><strong>Accuracy class (OIML R60)<\/strong><\/td>\n<td>\u2014<\/td>\n<td>0.05<br \/>\nC3<br \/>\nC5 \/ C4 Mi 7.5 (1 \u2013 100 t)<\/td>\n<td>0.05<br \/>\nC3<\/td>\n<\/tr>\n<tr>\n<td><strong>Protection class according to EN_60_529 (IEC 529)<\/strong><\/td>\n<td>\u2014<\/td>\n<td>IP 68 \/ IP 69K<\/td>\n<td>IP 67<\/td>\n<\/tr>\n<tr>\n<td><strong>Number of wires<\/strong><\/td>\n<td>\u2014<\/td>\n<td>4<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td><strong>Wire cross-section<\/strong><\/td>\n<td>mm<sup>2<\/sup><\/td>\n<td>0.25<\/td>\n<td>0.25<\/td>\n<\/tr>\n<tr>\n<td><strong>Outer diameter<\/strong><\/td>\n<td>mm<\/td>\n<td>6.5 \u00b1 0.2<\/td>\n<td>5.9 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td><strong>Smallest bending radius<\/strong><\/td>\n<td>mm<\/td>\n<td>45<br \/>\n(movable 59)<\/td>\n<td>45<br \/>\n(movable 59)<\/td>\n<\/tr>\n<tr>\n<td><strong>Plug weight, approx.<\/strong><\/td>\n<td>g<\/td>\n<td>\u2014<\/td>\n<td>25<\/td>\n<\/tr>\n<tr>\n<td><strong>Standard cable lengths<\/strong><\/td>\n<td>m<\/td>\n<td>5<br \/>\n(1 t \u2013 15 t) and (150 t \u2013 470 t)<br \/>\n15<br \/>\n(22 t \u2013 100 t)<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td><strong>Optional cable lengths<\/strong><\/td>\n<td>m<\/td>\n<td>15<br \/>\n(1 t \u2013 15 t) and (150 t \u2013 470 t)<br \/>\n25<br \/>\n(Check ATEX version on request)<br \/>\n50<br \/>\n(not for ATEX)<\/td>\n<td>5<br \/>\n20<\/td>\n<\/tr>\n<tr>\n<td><strong>Nominal temperature<\/strong><\/td>\n<td>\u00b0C<\/td>\n<td>-30 \u2026 +150<\/td>\n<td>-20 \u2026 +80<\/td>\n<\/tr>\n<tr>\n<td><strong>Terminal allocation<\/strong><\/td>\n<td>\u2014<\/td>\n<td>black: input +<br \/>\nblue: input &#8211;<br \/>\nred: output +<br \/>\nwhite: output &#8211;<br \/>\nyellow: shielding<\/td>\n<td>pink: input +<br \/>\nblue: input &#8211;<br \/>\nred: output +<br \/>\nwhite: output &#8211;<br \/>\ngray: sense +<br \/>\ngreen: sense &#8211;<br \/>\nyellow: shielding<br \/>\nbrown: not assigned<\/td>\n<\/tr>\n<tr>\n<td><strong>Material<\/strong><br \/>\n&#8211; Plug housing<br \/>\n&#8211; Screw connection<br \/>\n&#8211; Plug sealing<br \/>\n&#8211; Wire insulation<br \/>\n&#8211; Cable sheath<\/td>\n<td>\u2014<\/td>\n<td>&#8211;<br \/>\n<span style=\"font-family: inherit; font-size: inherit;\">Zinc die-cast, nickel-plated<br \/>\n<\/span><span style=\"font-family: inherit; font-size: inherit;\">NBR<br \/>\n<\/span><span style=\"font-family: inherit; font-size: inherit;\">PP<br \/>\n<\/span><span style=\"font-family: inherit; font-size: inherit;\">TPE (silicone- \/ halogen-free), gray<\/span><\/td>\n<td>TPU (injection-molded)<br \/>\nZinc die-cast, nickel-plated<br \/>\nNBR<br \/>\nPP<br \/>\nPUR (halogen-free), black<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Order numbers<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"102\"><strong>Design<\/strong><\/td>\n<td colspan=\"5\" width=\"513\"><strong>Accuracy class<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"102\">\u00a0<\/td>\n<td width=\"103\"><strong>0.05<\/strong><\/td>\n<td width=\"103\"><strong>0.05 with plug<\/strong><\/td>\n<td width=\"103\"><strong>C3<\/strong><\/td>\n<td width=\"103\"><strong>C3<\/strong><sup>1)<\/sup> <strong>with plug<\/strong><sup>1)<\/sup><\/td>\n<td width=\"102\"><strong>C5 \/ C4 Mi 7.5<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>RTN 1 t<\/strong><\/td>\n<td width=\"103\">D726173.04<\/td>\n<td width=\"103\">D726173.79<\/td>\n<td width=\"103\">D726173.02<\/td>\n<td width=\"103\">D726173.80<\/td>\n<td width=\"102\">D726173.10<\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>RTN 2.2 t<\/strong><\/td>\n<td width=\"103\">D726174.04<\/td>\n<td width=\"103\">D726174.79<\/td>\n<td width=\"103\">D726174.02<\/td>\n<td width=\"103\">D726174.80<\/td>\n<td width=\"102\">D726174.10<\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>RTN 4.7 t<\/strong><\/td>\n<td width=\"103\">D726175.04<\/td>\n<td width=\"103\">D726175.79<\/td>\n<td width=\"103\">D726175.02<\/td>\n<td width=\"103\">D726175.80<\/td>\n<td width=\"102\">D726175.10<\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>RTN 10 t<\/strong><\/td>\n<td width=\"103\">D726176.04<\/td>\n<td width=\"103\">D726176.79<\/td>\n<td width=\"103\">D726176.02<\/td>\n<td width=\"103\">D726176.80<\/td>\n<td width=\"102\">D726176.10<\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>RTN 15 t<\/strong><\/td>\n<td width=\"103\">D726177.04<\/td>\n<td width=\"103\">D726177.79<\/td>\n<td width=\"103\">D726177.02<\/td>\n<td width=\"103\">D726177.80<\/td>\n<td width=\"102\">D726177.10<\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>RTN 22 t<\/strong><\/td>\n<td width=\"103\">D724781.04<\/td>\n<td width=\"103\">D724781.79<\/td>\n<td width=\"103\">D724781.02<\/td>\n<td width=\"103\">D724781.80<\/td>\n<td width=\"102\">D724781.10<\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>RTN 33 t<\/strong><\/td>\n<td width=\"103\">D724754.04<\/td>\n<td width=\"103\">D724754.79<\/td>\n<td width=\"103\">D724754.02<\/td>\n<td width=\"103\">D724754.80<\/td>\n<td width=\"102\">D724754.10<\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>RTN 47 t<\/strong><\/td>\n<td width=\"103\">D724782.04<\/td>\n<td width=\"103\">D724782.79<\/td>\n<td width=\"103\">D724782.02<\/td>\n<td width=\"103\">D724782.80<\/td>\n<td width=\"102\">D724782.10<\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>RTN 68 t<\/strong><\/td>\n<td width=\"103\">D724783.04<\/td>\n<td width=\"103\">D724783.79<\/td>\n<td width=\"103\">D724783.02<\/td>\n<td width=\"103\">D724783.80<\/td>\n<td width=\"102\">D724783.10<\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>RTN 100 t<\/strong><\/td>\n<td width=\"103\">D724784.04<\/td>\n<td width=\"103\">D724784.79<\/td>\n<td width=\"103\">D724784.02<\/td>\n<td width=\"103\">D724784.80<\/td>\n<td width=\"102\">D724784.10<\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>RTN 150 t<\/strong><\/td>\n<td width=\"103\">D726178.04<\/td>\n<td width=\"103\">D726178.79<\/td>\n<td width=\"103\">D726178.02<\/td>\n<td width=\"103\">D726178.80<\/td>\n<td width=\"102\">not available<\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>RTN 220 t<\/strong><\/td>\n<td width=\"103\">D726179.04<\/td>\n<td width=\"103\">not available<\/td>\n<td width=\"103\">D726179.02<\/td>\n<td width=\"103\">not available<\/td>\n<td width=\"102\">not available<\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>RTN 330 t<\/strong><\/td>\n<td width=\"103\">D726180.04<\/td>\n<td width=\"103\">not available<\/td>\n<td width=\"103\">D726180.02<\/td>\n<td width=\"103\">not available<\/td>\n<td width=\"102\">not available<\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>RTN 470 t<\/strong><\/td>\n<td width=\"103\">D726181.04<\/td>\n<td width=\"103\">not available<\/td>\n<td width=\"103\">D726181.02<\/td>\n<td width=\"103\">not available<\/td>\n<td width=\"102\">not available<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" width=\"615\"><strong>Spare part connection cable for plug<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>5 m<\/strong><\/td>\n<td colspan=\"5\" width=\"513\">V090162.B10<\/td>\n<\/tr>\n<tr>\n<td width=\"102\"><strong>20 m<\/strong><\/td>\n<td colspan=\"5\" width=\"513\">V090162.B11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><sup>1)<\/sup> Plug variant must not be used for scales that can be used for legal for trade purposes.<\/p>\n<p><strong>Options<\/strong><\/p>\n<ul>\n<li>Model for operating temperature up to 110 \u00b0C<\/li>\n<li>Additional corrosion protection<\/li>\n<li>Other cable lengths<\/li>\n<li>Protection class IP69K<\/li>\n<li>Rodent-proof cable<\/li>\n<li>Mounting holes<\/li>\n<\/ul>\n<p><strong>Installation accessories<\/strong><\/p>\n<div>\n<ul>\n<li><strong>SENSiQ <\/strong>Elastomer Mount (SEM)<\/li>\n<li><strong>SENSiQ <\/strong>Secure Mount (SSM)<\/li>\n<li><strong>SENSiQ <\/strong>Pendulum Mount (SPM)<\/li>\n<li><strong>SENSiQ <\/strong>Fixed Mount (SFM)<\/li>\n<\/ul>\n<p><strong><span lang=\"EN-US\" style=\"color: #231f20;\">EX <span style=\"letter-spacing: -.1pt;\">approvals<\/span><\/span><\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"100\">\u00a0<\/td>\n<td colspan=\"3\" width=\"266\"><strong>Intrinsically safe explosion-proof design<\/strong><\/td>\n<td colspan=\"3\" width=\"250\"><strong>Not intrinsically safe explosion-proof design<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"100\"><strong>ATEX \/ IECEx<\/strong><\/td>\n<td colspan=\"3\" width=\"266\">II 2G Ex ia IIC T4 Gb (Zone 1)<br \/>\nII 2D Ex ia IIIC T125\u00b0C Db, IP67 (Zone 21)<\/td>\n<td colspan=\"3\" width=\"250\">II 3G Ex ec IIC T4 Gc (Zone 2)<br \/>\nII 2D Ex tb IIIC T125 \u00b0C Db, IP67 (Zone 21)<\/td>\n<\/tr>\n<tr>\n<td width=\"100\"><strong>FM approval Canada<\/strong><\/td>\n<td colspan=\"3\" width=\"266\">I \/ 0 \/ Ex ia \/ IIC \/ T4; -30\u00b0C &lt; Ta &lt; 40\u00b0C \/ Ga;<br \/>\n20 \/ Ex ia \/ IIIC \/ T125\u00b0C; -30\u00b0C &lt; Ta &lt; 40\u00b0C \/ Da; IP67.<\/td>\n<td colspan=\"3\" width=\"250\">not available<\/td>\n<\/tr>\n<tr>\n<td width=\"100\"><strong>FM approval USA<\/strong><\/td>\n<td colspan=\"3\" width=\"266\">IS \/ I, II, III \/ 1 \/ A, B, C, D, E, F, G \/ T4; -30\u00b0C &lt; Ta &lt; 40\u00b0C, I \/ 0 \/ AEx ia \/ IIC \/ T4; -30\u00b0C &lt; Ta &lt; 40\u00b0C \/ Ga;<br \/>\n20 \/ AEx ia \/ IIIC \/ T125\u00b0C; -30\u00b0C &lt; Ta &lt; 40\u00b0C \/ Da;<br \/>\nIP67.<\/td>\n<td colspan=\"3\" width=\"250\">not available<\/td>\n<\/tr>\n<tr>\n<td width=\"100\"><strong>EAC<\/strong><\/td>\n<td colspan=\"3\" width=\"266\">1Ex ia IIC T4 Gb (Zone 1)<br \/>\nEx ia IIIC T125\u00b0C Db X (Zone 21)<\/td>\n<td colspan=\"3\" width=\"250\">2Ex nA II T4 Gc (Zone 2)<br \/>\nEx tb IIIC T125 \u00b0C Db X (Zone 21)<\/td>\n<\/tr>\n<tr>\n<td width=\"100\"><strong>KOSHA<br \/>\n<\/strong><strong>(only RTN 1 t \u2013 4.7 t)<\/strong><\/td>\n<td colspan=\"3\" width=\"266\">Ex ia IIC T4 Gb (Zone 1)<br \/>\nEx ia IIIC T125\u00b0C Db, IP67 (Zone 21)<\/td>\n<td colspan=\"3\" width=\"250\">Ex ec IIC T4 Gc (Zone 2)<br \/>\nEx tb IIIC T125 \u00b0C Db, IP67 (Zone 21)<\/td>\n<\/tr>\n<tr>\n<td width=\"100\"><strong>Accuracy class<\/strong><\/td>\n<td width=\"120\">0.05<br \/>\n2GD<\/td>\n<td width=\"69\">C3 2GD<\/td>\n<td width=\"77\">C5 \/ C4 Mi 7.5 2GD<\/td>\n<td width=\"113\">0.05<br \/>\n2D, 3G<\/td>\n<td width=\"69\">C3 2D, 3G<\/td>\n<td width=\"68\">C5 \/ C4 Mi 7.5 2D, 3G<\/td>\n<\/tr>\n<tr>\n<td width=\"100\"><strong>Design<\/strong><\/td>\n<td width=\"120\">Dxxxxxx .82<\/td>\n<td width=\"69\">Dxxxxxx .81<\/td>\n<td width=\"77\">Dxxxxxx .83<\/td>\n<td width=\"113\">Dxxxxxx .86<\/td>\n<td width=\"69\">Dxxxxxx .85<\/td>\n<td width=\"68\">Dxxxxxx .87<\/td>\n<\/tr>\n<tr>\n<td width=\"100\"><strong>Design KOSHA<\/strong><\/td>\n<td width=\"120\">D726173.92 (RTN 1 t) D726174.92 (RTN 2.2 t)<br \/>\nD726175.94 (RTN 4.7 t)<\/td>\n<td width=\"69\">not available<\/td>\n<td width=\"77\">not available<\/td>\n<td width=\"113\">D726173.96 (RTN 1 t) D726174.96 (RTN 2.2 t)<br \/>\nD726175.96 (RTN 4.7 t)<\/td>\n<td width=\"69\">not available<\/td>\n<td width=\"68\">not available<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Load cells marked as intrinsically safe (Ex &#8220;i&#8221;) are operated in an intrinsically safe manner regardless of the zone.<\/p>\n<\/div>\n<p>CAUTION! The verification of intrinsically safe circuit must be verified. New barriers are provided in particular for new systems. Verifications of intrinsic safety are available for all load cells and barriers.<\/p>\n<p><strong>Order example<\/strong>:<br \/>\n47 t, precision class C3, ATEX category 2D, 3G. Type RTN 47 t C3 2D, 3G<br \/>\nOrder number D724782.85<\/p>\n<a href=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/12\/RTN.pdf\" class=\"pdfemb-viewer\" style=\"\" data-width=\"max\" data-height=\"max\" data-toolbar=\"both\" data-toolbar-fixed=\"on\">RTN<\/a>\n","protected":false},"excerpt":{"rendered":"<p>\u25aa Legal-for-trade design according to OIML(up to 5000 d and 7500 d for multi-interval scales)<br \/>\n\u25aa High precision even for very small application ranges<br \/>\n\u25aa Large output signal and this highresolution useful signal range<br \/>\n\u25aa Due to the low power consumption, multiscale systems can also be realized using simple analysis electronics<br \/>\n\u25aa Approvals for potentially explosive areas available: ATEX, IECEx, EAC, USA, Canada, Korea<br \/>\n\u25aa Protective rating: up to IP68<\/p>\n","protected":false},"featured_media":286380,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[3394],"product_tag":[5424,5425],"class_list":{"0":"post-286389","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-torsion-load-cell","7":"product_tag---en","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Schenck Process \/ RTN \/ Ring Torsion Load Cell - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"\u25aa Legal-for-trade design according to OIML(up to 5000 d and 7500 d for multi-interval scales) \u25aa High precision even for very small application ranges \u25aa Large output signal and this highresolution useful signal range \u25aa Due to the low power consumption, multiscale systems can also be realized using simple analysis electronics \u25aa Approvals for potentially explosive areas available: ATEX, IECEx, EAC, USA, Canada, Korea \u25aa Protective rating: up to IP68\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/product\/schenck-process-rtn-ring-torsion-load-cell\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Schenck Process \/ RTN \/ Ring Torsion Load Cell\" \/>\n<meta property=\"og:description\" content=\"\u25aa Legal-for-trade design according to OIML(up to 5000 d and 7500 d for multi-interval scales) \u25aa High precision even for very small application ranges \u25aa Large output signal and this highresolution useful signal range \u25aa Due to the low power consumption, multiscale systems can also be realized using simple analysis electronics \u25aa Approvals for potentially explosive areas available: ATEX, IECEx, EAC, USA, Canada, Korea \u25aa Protective rating: up to IP68\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/product\/schenck-process-rtn-ring-torsion-load-cell\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-09T00:06:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2025\/12\/loadcellrtn4-_7t_1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"700\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-rtn-ring-torsion-load-cell\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-rtn-ring-torsion-load-cell\\\/\",\"name\":\"Schenck Process \\\/ RTN \\\/ Ring Torsion Load Cell - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-rtn-ring-torsion-load-cell\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-rtn-ring-torsion-load-cell\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/loadcellrtn4-_7t_1.jpg\",\"datePublished\":\"2025-12-01T06:55:08+00:00\",\"dateModified\":\"2026-04-09T00:06:16+00:00\",\"description\":\"\u25aa Legal-for-trade design according to OIML(up to 5000 d and 7500 d for multi-interval scales) \u25aa High precision even for very small application ranges \u25aa Large output signal and this highresolution useful signal range \u25aa Due to the low power consumption, multiscale systems can also be realized using simple analysis electronics \u25aa Approvals for potentially explosive areas available: ATEX, IECEx, EAC, USA, Canada, Korea \u25aa Protective rating: up to IP68\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-rtn-ring-torsion-load-cell\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-rtn-ring-torsion-load-cell\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-rtn-ring-torsion-load-cell\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/loadcellrtn4-_7t_1.jpg\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/loadcellrtn4-_7t_1.jpg\",\"width\":700,\"height\":700},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-rtn-ring-torsion-load-cell\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Schenck Process \\\/ RTN \\\/ Ring Torsion Load Cell\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/product\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Schenck Process \/ RTN \/ Ring Torsion Load Cell - CAS Scale Korea Co., Ltd.","description":"\u25aa Legal-for-trade design according to OIML(up to 5000 d and 7500 d for multi-interval scales) \u25aa High precision even for very small application ranges \u25aa Large output signal and this highresolution useful signal range \u25aa Due to the low power consumption, multiscale systems can also be realized using simple analysis electronics \u25aa Approvals for potentially explosive areas available: ATEX, IECEx, EAC, USA, Canada, Korea \u25aa Protective rating: up to IP68","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/product\/schenck-process-rtn-ring-torsion-load-cell\/","og_locale":"en_US","og_type":"article","og_title":"Schenck Process \/ RTN \/ Ring Torsion Load Cell","og_description":"\u25aa Legal-for-trade design according to OIML(up to 5000 d and 7500 d for multi-interval scales) \u25aa High precision even for very small application ranges \u25aa Large output signal and this highresolution useful signal range \u25aa Due to the low power consumption, multiscale systems can also be realized using simple analysis electronics \u25aa Approvals for potentially explosive areas available: ATEX, IECEx, EAC, USA, Canada, Korea \u25aa Protective rating: up to IP68","og_url":"https:\/\/casscale.net\/en\/product\/schenck-process-rtn-ring-torsion-load-cell\/","og_site_name":"CAS Scale Korea Co., Ltd.","article_modified_time":"2026-04-09T00:06:16+00:00","og_image":[{"width":700,"height":700,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/12\/loadcellrtn4-_7t_1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/product\/schenck-process-rtn-ring-torsion-load-cell\/","url":"https:\/\/casscale.net\/en\/product\/schenck-process-rtn-ring-torsion-load-cell\/","name":"Schenck Process \/ RTN \/ Ring Torsion Load Cell - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/product\/schenck-process-rtn-ring-torsion-load-cell\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/product\/schenck-process-rtn-ring-torsion-load-cell\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/12\/loadcellrtn4-_7t_1.jpg","datePublished":"2025-12-01T06:55:08+00:00","dateModified":"2026-04-09T00:06:16+00:00","description":"\u25aa Legal-for-trade design according to OIML(up to 5000 d and 7500 d for multi-interval scales) \u25aa High precision even for very small application ranges \u25aa Large output signal and this highresolution useful signal range \u25aa Due to the low power consumption, multiscale systems can also be realized using simple analysis electronics \u25aa Approvals for potentially explosive areas available: ATEX, IECEx, EAC, USA, Canada, Korea \u25aa Protective rating: up to IP68","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/product\/schenck-process-rtn-ring-torsion-load-cell\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/product\/schenck-process-rtn-ring-torsion-load-cell\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/product\/schenck-process-rtn-ring-torsion-load-cell\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/12\/loadcellrtn4-_7t_1.jpg","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/12\/loadcellrtn4-_7t_1.jpg","width":700,"height":700},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/product\/schenck-process-rtn-ring-torsion-load-cell\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"Schenck Process \/ RTN \/ Ring Torsion Load Cell"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/product\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/286389","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=286389"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/286380"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=286389"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=286389"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=286389"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=286389"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}