{"id":286602,"date":"2026-01-16T09:30:09","date_gmt":"2026-01-16T00:30:09","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/blh-nobel-clc-load-cell\/"},"modified":"2026-01-16T09:30:09","modified_gmt":"2026-01-16T00:30:09","slug":"blh-nobel-clc-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/blh-nobel-clc-load-cell\/","title":{"rendered":"BLH NOBEL \/ CLC Load Cell"},"content":{"rendered":"<h2 class=\"pattern-title ng-tns-c11-10 ng-star-inserted\">CLC Load Cell<\/h2>\n<p><strong>Features<\/strong><br \/>\nCapacity 250-2000 kN<br \/>\nOther capacities on request<br \/>\nVery low profile<br \/>\nHigh long-term stability and repeatability<br \/>\nOperating temperature range -40 to +80\u00b0C (+125\u00b0C with optional Teflon Cable)<br \/>\n10m special cable. Option: Load cell with connector<br \/>\nYellow chromate steel<br \/>\nProtection class IP67<br \/>\nOPTIONS<br \/>\nLoad Cell can be customized to a large variety in dimensions and capacities<br \/>\nCustomized adaptor plates and other mounting assemblies on request<br \/>\nApplication: Strip &amp; Web Tension,Process Weighing &amp; Batching<br \/>\nCombined Error: 0-0.05 %<br \/>\nEnvironment Protection Class: IP67,IP66,IP65,IP54,IP20<br \/>\nIndustry: Metal,Mining,Pulp &amp; Paper,Automotive,Chemical<br \/>\nMaterial: Plated Steel<br \/>\nMax Capacity: k lb: 115-450<br \/>\nMax Capacity: kN: 500-2000<br \/>\nMax Capacity: ton: 50-200<br \/>\nProduct Type: Weigh Modules &amp; Load Cells<\/p>\n<p><strong>OUTLINE DIMENSIONS IN MM<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-286600\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/CLC-2.png\" alt=\"\" width=\"1485\" height=\"764\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/CLC-2.png 1485w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/CLC-2-777x400.png 777w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/CLC-2-1400x720.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/CLC-2-768x395.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/CLC-2-600x309.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/CLC-2-64x33.png 64w\" sizes=\"(max-width: 1485px) 100vw, 1485px\" \/><\/p>\n<p><strong>Low Proile Shear Force Load Cell<br \/>\nSpecifications<br \/>\n<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>PERFORMANCE<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Rated capacity (R.C.)<\/td>\n<td>250, 500, 1000, 2000 kN<\/td>\n<\/tr>\n<tr>\n<td>Rated output (R.O.)<\/td>\n<td>2.0 mV\/V<\/td>\n<\/tr>\n<tr>\n<td>Combined error<\/td>\n<td>\u00b1&lt;0.1% of C<\/td>\n<\/tr>\n<tr>\n<td>Safe load<\/td>\n<td>200% R.C.<\/td>\n<\/tr>\n<tr>\n<td>Ultimate load<\/td>\n<td>&gt;300% R.C.<\/td>\n<\/tr>\n<tr>\n<td>Max. admissible side load<\/td>\n<td>50% R.C.<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>TEMPERATURE<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Temperature effect on zero<\/td>\n<td>\u00b10.005% of R.O. \/ \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature effect on output<\/td>\n<td>\u00b10.005% of output \/ \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Nominal temperature range<\/td>\n<td>\u201310 to +80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature range<\/td>\n<td>\u201340 to +80 \u00b0C (+125 \u00b0C on request)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>ELECTRICAL<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Recommended excitation<\/td>\n<td>10 VDC or VAC<\/td>\n<\/tr>\n<tr>\n<td>Max. supply voltage<\/td>\n<td>36 VDC or VAC<\/td>\n<\/tr>\n<tr>\n<td>Input impedance<\/td>\n<td>750 \u2126 \u00b115 \u2126<\/td>\n<\/tr>\n<tr>\n<td>Output impedance<\/td>\n<td>700 \u2126 \u00b110 \u2126<\/td>\n<\/tr>\n<tr>\n<td>Insulation impedance<\/td>\n<td>&gt; 2000 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>MECHANICAL \/ CONSTRUCTION<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Material<\/td>\n<td>Yellow chromate zinc plated steel<\/td>\n<\/tr>\n<tr>\n<td>Environmental protection<\/td>\n<td>IP67<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>BLH Nobel is continually seeking to improve product quality and performance. Speciications may change accordingly.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The model CLC is a very low profile load cell, working according to the shear force principle (no membrane), ideally suited for applications in harsh environments. Due to the special design, the CLC load cell is insensitive against side loading and other interfering effects. Because of the high operating temperature range of -40 up to +125\u00b0C, the CLC load cell is suitable for use in steel mills and foundries. Due to the high repeatability and high long-term stability, the load cell supplies very good results, even after perennial use. Protection class IP67 gives an excellent protection against dust and moisture.<\/p>\n","protected":false},"featured_media":286599,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5427],"product_cat":[3386],"product_tag":[4950],"class_list":{"0":"post-286602","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-blh-nobel","7":"product_cat-cylindrical-pancake","8":"product_tag-pancake-type","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/286602","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=286602"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/286599"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=286602"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=286602"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=286602"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=286602"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}