{"id":286848,"date":"2026-01-16T16:38:42","date_gmt":"2026-01-16T07:38:42","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/schenck-process-wd-15-t-200-t\/"},"modified":"2026-01-16T16:38:42","modified_gmt":"2026-01-16T07:38:42","slug":"schenck-process-wd-15-t-200-t","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/schenck-process-wd-15-t-200-t\/","title":{"rendered":"Schenck Process \/ WD 15 t \u2026 200 t"},"content":{"rendered":"<h2>SENSiQ\u00ae Weighdisc WD 15 t \u2026 200 t<\/h2>\n<p><strong>Application<\/strong><br \/>\n\uf0a7 Ladle turret scale<br \/>\n\uf0a7 Ladle transfer car<br \/>\n\uf0a7 Scrap basket, roller and tundish scales<br \/>\n\uf0a7 Rail weighbridges<br \/>\n\uf0a7 Silo, container and furnace scales<br \/>\nConstruction<br \/>\n\uf0a7 Very low installation height and installation space<br \/>\n\uf0a7 Two contact surfaces for a direct bolted joint<br \/>\n\uf0a7 Robust measuring element without membrane<br \/>\nFunction<br \/>\n\uf0a7 Simple and cost-effective installation through direct bolted joints between the upper and lower connecting structure without moving parts<br \/>\n\uf0a7 High functional safety and availability, even with impact loads and constraining forces<br \/>\n\uf0a7 Minimum measuring value interference despite the transmission of large interference forces and moments<br \/>\n\uf0a7 For maintenance-free scales operated under harsh conditions<br \/>\n\uf0a7 High overload capability<br \/>\n\uf0a7 High reproducibility<br \/>\n\uf0a7 High long-term stability<br \/>\n\uf0a7 Connection dimensions and electrical data are compatible with the earlier design of WDI \/ WDI-K according to data sheet BV-D2206 \/ BV-D2220<br \/>\n\uf0a7 The plug connection differs from earlier designs of the WDI \/ WDI-K but is identical to the plug connection of the SENSiQ Weighbeam WB type series.<\/p>\n<p><strong>Operating Principle<\/strong><\/p>\n<p>WD 15 t \u2026 200 t<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-286842\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD1.png\" alt=\"\" width=\"1473\" height=\"629\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD1.png 1473w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD1-800x342.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD1-1400x598.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD1-768x328.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD1-600x256.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD1-64x27.png 64w\" sizes=\"(max-width: 1473px) 100vw, 1473px\" \/><\/p>\n<p><strong>Technical Data<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td rowspan=\"2\" width=\"168\">&nbsp;<\/td>\n<td rowspan=\"2\" width=\"28\">&nbsp;<\/td>\n<td rowspan=\"2\" width=\"95\">WD 15 t<\/td>\n<td colspan=\"2\" rowspan=\"2\" width=\"62\">WD 25 t<\/td>\n<td colspan=\"2\" rowspan=\"2\" width=\"62\">WD 50 t<\/td>\n<td colspan=\"2\" rowspan=\"2\" width=\"62\">WD 100 t<\/td>\n<td rowspan=\"2\" width=\"62\">WD 200 t<\/td>\n<td rowspan=\"2\" width=\"77\">Ref<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Accuracy class<sup>1)<\/sup><\/td>\n<td width=\"28\">&nbsp;<\/td>\n<td colspan=\"8\" width=\"342\">D 0,1<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Nominal load<\/td>\n<td width=\"28\">Emax<\/td>\n<td width=\"95\">15 t<\/td>\n<td colspan=\"2\" width=\"62\">25 t<\/td>\n<td colspan=\"2\" width=\"62\">50 t<\/td>\n<td colspan=\"2\" width=\"62\">100 t<\/td>\n<td width=\"62\">200 t<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Limit load (with Lq = 0.15 x LI) Limit load = max. safe load<\/td>\n<td width=\"28\">&nbsp;<\/p>\n<p>LI<\/td>\n<td width=\"95\">75 t<\/td>\n<td colspan=\"2\" width=\"62\">75 t<\/td>\n<td colspan=\"2\" width=\"62\">150 t<\/td>\n<td colspan=\"2\" width=\"62\">300 t<\/td>\n<td width=\"62\">600 t<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Breaking load (with Lq = 0.15 x Ld)<\/td>\n<td width=\"28\">Ld<\/td>\n<td width=\"95\">125 t<\/td>\n<td colspan=\"2\" width=\"62\">125 t<\/td>\n<td colspan=\"2\" width=\"62\">250 t<\/td>\n<td colspan=\"2\" width=\"62\">500 t<\/td>\n<td width=\"62\">1000 t<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Max. permitted lateral load<\/td>\n<td width=\"28\">Lq, max<\/td>\n<td width=\"95\">12 t<\/td>\n<td colspan=\"2\" width=\"62\">12 t<\/td>\n<td colspan=\"2\" width=\"62\">25 t<\/td>\n<td colspan=\"2\" width=\"62\">50 t<\/td>\n<td width=\"62\">100 t<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Nominal characteristic value<\/td>\n<td width=\"28\">Cn<\/td>\n<td width=\"95\">0.54 \u00b1 0,002 mV \/ V<\/td>\n<td colspan=\"7\" width=\"247\">0,9 \u00b1 0,002 mV \/ V<\/td>\n<td width=\"77\">Emax<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Compound error<\/td>\n<td width=\"28\">Fcomb<\/td>\n<td colspan=\"8\" width=\"342\">0,07 %<\/td>\n<td width=\"77\">Cn<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Creepage under load (30 min)<\/td>\n<td width=\"28\">Fcr<\/td>\n<td colspan=\"8\" width=\"342\">0,05 %<\/td>\n<td width=\"77\">Cn<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">max. admissible no. of legal-for-trade scale intervals<sup>1)<\/sup><\/td>\n<td width=\"28\">&nbsp;<\/p>\n<p>nLC<\/td>\n<td colspan=\"8\" width=\"342\">1000<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Smallest scale interval<sup>1)<\/sup><\/td>\n<td width=\"28\">Vmin<\/td>\n<td colspan=\"8\" width=\"342\">Emax \/ 1000<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Input resistance<\/td>\n<td width=\"28\">Re<\/td>\n<td colspan=\"8\" width=\"342\">694 \u03a9 <u>+<\/u>8 \u03a9<\/td>\n<td width=\"77\">Tr<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Output resistance<\/td>\n<td width=\"28\">Ra<\/td>\n<td colspan=\"8\" width=\"342\">700 \u03a9 <u>+<\/u>4 \u03a9<\/td>\n<td width=\"77\">Tr<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Ref- supply voltage<\/td>\n<td width=\"28\">Usref<\/td>\n<td colspan=\"8\" width=\"342\">10 V<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Max. supply voltage<\/td>\n<td width=\"28\">Usmax<\/td>\n<td colspan=\"8\" width=\"342\">36 V<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Nominal temperature<\/td>\n<td width=\"28\">Btn<\/td>\n<td colspan=\"8\" width=\"342\">-10 \u00b0C bis +100 \u00b0C<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Operating temperature<\/p>\n<p>(and storage temperature range)<\/td>\n<td width=\"28\">&nbsp;<\/p>\n<p>Btu<\/td>\n<td colspan=\"8\" width=\"342\">-40 \u00b0C bis +180 \u00b0C<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Temperature<\/td>\n<td width=\"28\">Tr<\/td>\n<td colspan=\"8\" width=\"342\">+22 \u00b0C<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Storage temperature range<\/td>\n<td width=\"28\">Bts<\/td>\n<td colspan=\"8\" width=\"342\">-50 \u00b0C to +180 \u00b0C<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Temperature coefficient of the zero signal<\/td>\n<td width=\"28\">TKo<\/td>\n<td colspan=\"8\" width=\"342\"><u>+<\/u>0.07 % \/ 10 K *)<\/td>\n<td width=\"77\">Cn in Btu<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Temperature coefficient of the<\/p>\n<p>characteristic value<\/td>\n<td width=\"28\">TKc<\/td>\n<td colspan=\"8\" width=\"342\"><u>+<\/u>0.15 % \/ 10 K *)<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Self-weight<\/td>\n<td width=\"28\">me<\/td>\n<td width=\"95\">10 kg<\/td>\n<td width=\"57\">10 kg<\/td>\n<td colspan=\"2\" width=\"47\">10 kg<\/td>\n<td colspan=\"2\" width=\"57\">20 kg<\/td>\n<td colspan=\"2\" width=\"85\">47 kg<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Surface<\/td>\n<td width=\"28\">&nbsp;<\/td>\n<td colspan=\"8\" width=\"342\">galvanized<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">Protection class<\/td>\n<td width=\"28\">&nbsp;<\/td>\n<td colspan=\"8\" width=\"342\">IP68<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Cable specification<\/td>\n<td width=\"28\">&nbsp;<\/td>\n<td colspan=\"8\" width=\"342\">The Weighdisc has a 200 mm connection cable with plug-pin connections.<\/p>\n<p>A separate, shielded cable (\u00d8 8.5 mm x 15 m) with socket and free cable end for the connection to the summation box is also supplied.<\/p>\n<p>&nbsp;<\/p>\n<p>The following applies to the cable:<\/p>\n<p>Silicon cable, bend radius: &gt; 40 mm; temperature range: -50 \u00b0C &#8230;+180 \u00b0C<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<tr>\n<td width=\"168\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Cable connection allocation<\/td>\n<td width=\"28\">&nbsp;<\/td>\n<td colspan=\"8\" width=\"342\">black:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 input\u00a0 +\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \/ blue:\u00a0 input\u00a0 &#8211; red:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 output\u00a0 +\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \/ white: output &#8211; yellow:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 sense\u00a0\u00a0 +\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \/ green:\u00a0 sense\u00a0\u00a0 &#8211;<\/p>\n<p>purple:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 temperature sensor \/ brown: temperature sensor black\/yellow:\u00a0 shielding<\/p>\n<p>&nbsp;<\/p>\n<p>(Not connected sense line \u2013 lines have to be insulated)<\/td>\n<td width=\"77\">&nbsp;<\/td>\n<td width=\"0\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><sup>1)<\/sup> For information only<br \/>\n<sup>2)<\/sup> In isothermic state<\/p>\n<p><strong>Dimensions<\/strong><br \/>\nWD 15 t \u2026 200 t<img decoding=\"async\" class=\"alignnone size-full wp-image-286844\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD2.png\" alt=\"\" width=\"1507\" height=\"1471\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD2.png 1507w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD2-410x400.png 410w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD2-820x800.png 820w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD2-768x750.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD2-600x586.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD2-64x62.png 64w\" sizes=\"(max-width: 1507px) 100vw, 1507px\" \/><\/p>\n<p style=\"text-align: right;\"><strong><span lang=\"EN-US\">Dimensions <span style=\"letter-spacing: -.2pt;\">[mm]<\/span><\/span><\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"86\"><strong>\u00a0<\/strong><\/p>\n<p>Model<\/td>\n<td width=\"38\"><strong>\u00a0<\/strong><\/p>\n<p>A<\/td>\n<td width=\"38\"><strong>\u00a0<\/strong><\/p>\n<p>B<\/td>\n<td width=\"38\"><strong>\u00a0<\/strong><\/p>\n<p>C<\/td>\n<td width=\"39\"><strong>\u00a0<\/strong><\/p>\n<p>D<\/td>\n<td width=\"38\"><strong>\u00a0<\/strong><\/p>\n<p>E<\/td>\n<td width=\"38\"><strong>\u00a0<\/strong><\/p>\n<p>G<\/td>\n<td width=\"39\"><strong>\u00a0<\/strong><\/p>\n<p>H<\/td>\n<td width=\"39\"><strong>\u00a0<\/strong><\/p>\n<p>I<\/td>\n<td width=\"39\"><strong>\u00a0<\/strong><\/p>\n<p>K<\/td>\n<td width=\"39\"><strong>\u00a0<\/strong><\/p>\n<p>L*<\/td>\n<td width=\"38\"><strong>\u00a0<\/strong><\/p>\n<p>M<\/td>\n<td width=\"53\"><strong>\u00a0<\/strong><\/p>\n<p>N<\/td>\n<td width=\"47\"><strong>\u00a0<\/strong><\/p>\n<p>O<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">WD 15 t \/ 25 t<\/td>\n<td width=\"38\">192<\/td>\n<td width=\"38\">136<\/td>\n<td width=\"38\">70<\/td>\n<td width=\"39\">65<\/td>\n<td width=\"38\">28<\/td>\n<td width=\"38\">16<\/td>\n<td width=\"39\">168<\/td>\n<td width=\"39\">115<\/td>\n<td width=\"39\">16.5<\/td>\n<td width=\"39\">M16<\/td>\n<td width=\"38\">26<\/td>\n<td width=\"53\">20<\/td>\n<td width=\"47\">16.5<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">WD 50 t<\/td>\n<td width=\"38\">192<\/td>\n<td width=\"38\">136<\/td>\n<td width=\"38\">70<\/td>\n<td width=\"39\">65<\/td>\n<td width=\"38\">28<\/td>\n<td width=\"38\">16<\/td>\n<td width=\"39\">168<\/td>\n<td width=\"39\">115<\/td>\n<td width=\"39\">16.5<\/td>\n<td width=\"39\">M16<\/td>\n<td width=\"38\">26<\/td>\n<td width=\"53\">24<\/td>\n<td width=\"47\">16.5<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">WD 100 t<\/td>\n<td width=\"38\">265<\/td>\n<td width=\"38\">195<\/td>\n<td width=\"38\">100<\/td>\n<td width=\"39\">88<\/td>\n<td width=\"38\">36<\/td>\n<td width=\"38\">23<\/td>\n<td width=\"39\">234<\/td>\n<td width=\"39\">164<\/td>\n<td width=\"39\">22<\/td>\n<td width=\"39\">M20<\/td>\n<td width=\"38\">32<\/td>\n<td width=\"53\">32<\/td>\n<td width=\"47\">21<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">WD 200 t<\/td>\n<td width=\"38\">350<\/td>\n<td width=\"38\">263<\/td>\n<td width=\"38\">140<\/td>\n<td width=\"39\">120<\/td>\n<td width=\"38\">54<\/td>\n<td width=\"38\">25<\/td>\n<td width=\"39\">310<\/td>\n<td width=\"39\">220<\/td>\n<td width=\"39\">26<\/td>\n<td width=\"39\">M24<\/td>\n<td width=\"38\">38<\/td>\n<td width=\"53\">53.5<\/td>\n<td width=\"47\">25<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* Metric thread<\/p>\n<p>Requirements of the Quality of both Contact Surfaces<\/p>\n<p>WD 15 t \u2026 200 t<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-286846\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD3.png\" alt=\"\" width=\"1390\" height=\"615\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD3.png 1390w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD3-800x354.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD3-768x340.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD3-600x265.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/WD3-64x28.png 64w\" sizes=\"(max-width: 1390px) 100vw, 1390px\" \/><\/p>\n<ul>\n<li>Material selection &#8220;A&#8221;:<\/li>\n<\/ul>\n<p>As a rule, construction steel is used of at least S235 grade<\/p>\n<ul>\n<li>Operating thickness &#8220;B&#8221;:<\/li>\n<\/ul>\n<p>This depends on the stiffness of the overall construction. The operating thickness of the contact surfaces must be large enough such that the deflection under the rated load is less than 0.05 mm<\/p>\n<ul>\n<li>Surface quality &#8220;C&#8221;:<\/li>\n<\/ul>\n<p>The average peak-to-valley height required of the contact surfaces is 6.3 \u03bcm<\/p>\n<ul>\n<li>Flatness &#8220;D&#8221;:<\/li>\n<\/ul>\n<p>The maximum permissible flatness tolerance of each contact surface is 0.03 mm<\/p>\n<ul>\n<li>Plane parallelism &#8220;F&#8221;:<\/li>\n<\/ul>\n<p>The upper and lower contact surfaces to the Weighdisc must be plan parallel to each other within at least 0.1 mm]<\/p>\n<p><strong>Installation<\/strong> <strong>note:<\/strong><\/p>\n<p>If the WD is mounted on an interim plate, the entire unit can be removed more easily. Otherwise, the entire load has to be dismantled in order to access the middle fixing screw.<\/p>\n<p><strong>Order Numbers<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"358\"><strong>Variants<\/strong><\/td>\n<td width=\"246\"><strong>Order Number<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"358\"><strong>Weighdisc with plug connection and 15 m cable<\/strong><\/td>\n<td width=\"246\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"25\">WD<\/td>\n<td width=\"333\">15 t<\/td>\n<td width=\"246\">V713566B01<\/td>\n<\/tr>\n<tr>\n<td width=\"25\">WD<\/td>\n<td width=\"333\">25 t<\/td>\n<td width=\"246\">V713566B11<\/td>\n<\/tr>\n<tr>\n<td width=\"25\">WD<\/td>\n<td width=\"333\">50 t<\/td>\n<td width=\"246\">V713566B21<\/td>\n<\/tr>\n<tr>\n<td width=\"25\">WD<\/td>\n<td width=\"333\">100 t<\/td>\n<td width=\"246\">V713566B31<\/td>\n<\/tr>\n<tr>\n<td width=\"25\">WD<\/td>\n<td width=\"333\">200 t<\/td>\n<td width=\"246\">V713566B41<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"358\"><strong>Spare part: 15 m connecting cable with plug connection<\/strong><\/td>\n<td width=\"246\">V090162B01<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"358\"><strong>Spare part: 15 m connecting cable with old plug connection <\/strong><strong>1)<\/strong><\/td>\n<td width=\"246\">V023643B01<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"358\"><strong>Adapter for the old 15 m connecting cable <\/strong><strong>2)<\/strong><\/td>\n<td width=\"246\">V036069B10<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"358\"><u>High-temperature<\/u> <u>cable:<\/u><\/p>\n<p>15 m with plug socket<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Constant operation <\/strong>of the cable is permitted at &#8211;<strong>65 \u00b0C -300 \u00b0C.<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>Operation is permitted at <strong>700 \u00b0C <\/strong>for a period of <strong>up to 90 minutes.<\/strong><\/td>\n<td width=\"246\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>V090162B07<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"358\"><u>Measuring Cable:<\/u> 30 m<\/td>\n<td width=\"246\">V090162B04<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<ul>\n<li>Only compatible with the old design WDI-K according to data sheet (BV-D2206 \/ BV-D2220); relevant for cable replacement on<\/li>\n<li>If the old cable remains on site and the WDI-K is swapped for a<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\uf0a7 The original, proven over more than 10 years, optimized to the latest state of technology<br \/>\n\uf0a7 Operating temperature from -40 \u00b0C \u2026 180 \u00b0C<br \/>\n\uf0a7 High precision: combined error only 0.07%<br \/>\n\uf0a7 Air chamber to the direct bolted joint, no bearing elements needed<br \/>\n\uf0a7 Extremely robust construction, IP68, overvoltage protection<br \/>\n\uf0a7 Minimum installation space<br \/>\n\uf0a7 6-wire technology and integrated Pt100<\/p>\n","protected":false},"featured_media":286841,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5437],"product_cat":[3386],"product_tag":[4338,5105],"class_list":{"0":"post-286848","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-schenck-process","7":"product_cat-cylindrical-pancake","8":"product_tag-disk-type","9":"product_tag--en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/286848","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=286848"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/286841"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=286848"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=286848"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=286848"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=286848"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}