{"id":286916,"date":"2026-01-19T10:11:31","date_gmt":"2026-01-19T01:11:31","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/schenck-process-weighbeam-dmr-15t\/"},"modified":"2026-01-19T10:11:31","modified_gmt":"2026-01-19T01:11:31","slug":"schenck-process-weighbeam-dmr-15t","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/schenck-process-weighbeam-dmr-15t\/","title":{"rendered":"Schenck Process \/ Weighbeam DMR 15t"},"content":{"rendered":"<h2>Weighbeam DMR 15t<\/h2>\n<p><strong>APPLICATION<\/strong><\/p>\n<ul>\n<li>Railway scales<\/li>\n<li>Crane scales<\/li>\n<li>Coil scales<\/li>\n<\/ul>\n<p><strong>EQUIPMENT<\/strong><\/p>\n<ul>\n<li>Two-line load introduction and outlet<\/li>\n<li>Stainless steel<\/li>\n<li>Hermetically sealed<\/li>\n<\/ul>\n<p><strong>FUNCTION<\/strong><\/p>\n<ul>\n<li>High repeatability<\/li>\n<li>High long-term stability and consistently high accuracy<\/li>\n<li>No additional tie-rods or hold-downs<\/li>\n<li>Optional execution with two measuring circuits inside one sensor available<\/li>\n<\/ul>\n<p><strong>Mounting Dimensions<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-286912\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR.png\" alt=\"\" width=\"1692\" height=\"1752\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR.png 1692w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR-386x400.png 386w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR-773x800.png 773w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR-768x795.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR-1483x1536.png 1483w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR-600x621.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR-64x66.png 64w\" sizes=\"(max-width: 1692px) 100vw, 1692px\" \/><\/p>\n<p><strong>Technical Data<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"4\" width=\"616\"><strong>DMR 15 t<\/strong><\/td>\n<td width=\"61\">Ref.<\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Rated capacity<\/td>\n<td width=\"66\">Emax<\/td>\n<td colspan=\"2\" width=\"286\">15 t<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Accuracy class<\/td>\n<td width=\"66\"><\/td>\n<td width=\"136\">C1 (OIML R60)<\/p>\n<p>C2 upon request<\/td>\n<td width=\"150\">0.1<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Number of increments<\/td>\n<td width=\"66\">nLC<\/td>\n<td width=\"136\">1000<\/td>\n<td width=\"150\"><\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Nominal measuring range<\/td>\n<td width=\"66\">Bmax<\/td>\n<td colspan=\"2\" width=\"286\">Bmax = Emax<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Sensitivity<\/td>\n<td width=\"66\">C<sub>n<\/sub><\/td>\n<td colspan=\"2\" width=\"286\">2.00 mV\/V<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Combined error<\/td>\n<td width=\"66\">Fcomb<\/td>\n<td width=\"136\"><u>+<\/u> 0.06 %<\/td>\n<td width=\"150\"><u>+<\/u> 0.1 %<\/td>\n<td width=\"61\">C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Return of minimum preload signal<\/td>\n<td width=\"66\">dDR<\/td>\n<td width=\"136\"><u>+<\/u> 0.033 %<\/td>\n<td width=\"150\"><\/td>\n<td width=\"61\">C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Creep error (30 min)<\/td>\n<td width=\"66\">dcr<\/td>\n<td width=\"136\"><u>+<\/u> 0.049 %<\/td>\n<td width=\"150\"><u>+<\/u> 0.05 %<\/td>\n<td width=\"61\">C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Zero signal temperature coefficient<\/td>\n<td width=\"66\">TKsmin<\/td>\n<td colspan=\"2\" width=\"286\"><u>+<\/u> 0.028 % \/ 10K<\/td>\n<td width=\"61\">C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Sensitivity temperature coefficient<\/td>\n<td width=\"66\">TK<sub>c<\/sub><\/td>\n<td colspan=\"2\" width=\"286\"><u>+<\/u> 0.023 % \/ 10K<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Minimum increment value<\/td>\n<td width=\"66\">v min<\/td>\n<td width=\"136\">E<sub>max<\/sub> \/ 5000<\/td>\n<td width=\"150\">&#8212;<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Minimum measuring range<\/td>\n<td width=\"66\">Bmin<\/td>\n<td width=\"136\">33.3 %<\/td>\n<td width=\"150\">&#8212;<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Limit load (with L<sub>Q<\/sub> = 0.15 x E<sub>max<\/sub>)<\/td>\n<td width=\"66\">L<sub>L<\/sub><\/td>\n<td colspan=\"2\" width=\"286\">26 t<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Rupture load (with L<sub>Q<\/sub> = 0.15 x E<sub>max<\/sub>)<\/td>\n<td width=\"66\">L<sub>B<\/sub><\/td>\n<td colspan=\"2\" width=\"286\">38 t<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Max. lateral load<\/td>\n<td width=\"66\">L<sub>Q<\/sub><\/td>\n<td colspan=\"2\" width=\"286\">13 t<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Input resistance<\/td>\n<td width=\"66\">RLC<\/td>\n<td colspan=\"2\" width=\"286\">378 <u>+<\/u> 3 ohms<\/td>\n<td width=\"61\">tref<\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Output resistance<\/td>\n<td width=\"66\">R<sub>o<\/sub><\/td>\n<td colspan=\"2\" width=\"286\">360 <u>+<\/u> 0.5 ohms<\/td>\n<td width=\"61\">tref<\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Zero signal<\/td>\n<td width=\"66\">S<sub>o<\/sub><\/td>\n<td colspan=\"2\" width=\"286\"><u>+<\/u> 1%<\/td>\n<td width=\"61\">C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Relative sensitivity deviation<\/td>\n<td width=\"66\">d<sub>c<\/sub><\/td>\n<td colspan=\"2\" width=\"286\"><u>+<\/u> 0.2%<\/td>\n<td width=\"61\">C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Supply voltage nominal range<\/td>\n<td width=\"66\">B<sub>U<\/sub><\/td>\n<td colspan=\"2\" width=\"286\">5 V to 12 V<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Nominal temperature range<\/td>\n<td width=\"66\">B<sub>T<\/sub><\/td>\n<td colspan=\"2\" width=\"286\">-10\u00b0C to +40\u00b0C<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Service temperature range<\/td>\n<td width=\"66\">Btu<\/td>\n<td colspan=\"2\" width=\"286\">-30\u00b0C to +120\u00b0C<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Reference temperature<\/td>\n<td width=\"66\">tref<\/td>\n<td colspan=\"2\" width=\"286\">22\u00b0C<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Material<\/td>\n<td width=\"66\"><\/td>\n<td colspan=\"2\" width=\"286\">Stainless steel<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Protected to<\/td>\n<td width=\"66\"><\/td>\n<td colspan=\"2\" width=\"286\">IP 67 (laser welded)<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Corrosion protection<\/td>\n<td width=\"66\"><\/td>\n<td colspan=\"2\" width=\"286\">see resistance list DDP8 483<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\">Dead weight<\/td>\n<td width=\"66\">m<sub>e<\/sub><\/td>\n<td colspan=\"2\" width=\"286\">25 kg<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\"><strong>\u00a0<\/strong><\/p>\n<p>Measuring cable<\/td>\n<td width=\"66\"><\/td>\n<td colspan=\"2\" width=\"286\">4 x 0.5 mm<sup>2<\/sup><\/p>\n<p>screened in pairs and external screening outer diameter 6.5 mm, Length 8 m Silicone, -30\u00b0C to +150\u00b0C<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<tr>\n<td width=\"265\"><strong>\u00a0<\/strong><\/p>\n<p>Colour code<\/td>\n<td width=\"66\"><\/td>\n<td colspan=\"2\" width=\"286\">Black:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Input +<\/p>\n<p>Blue:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Input &#8211;<\/p>\n<p>Red:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Output +<\/p>\n<p>White:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Output &#8211;<\/p>\n<p>Green-Yellow:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 screen<\/td>\n<td width=\"61\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Connecting surface quality requirements<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-286914\" style=\"font-family: inherit; text-align: center;\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR-2.png\" alt=\"\" width=\"1695\" height=\"868\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR-2.png 1695w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR-2-781x400.png 781w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR-2-1400x717.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR-2-768x393.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR-2-1536x787.png 1536w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR-2-600x307.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/DMR-2-64x33.png 64w\" sizes=\"(max-width: 1695px) 100vw, 1695px\" \/><\/p>\n<p><strong>INSTALLATION REQUIREMENTS<\/strong><\/p>\n<ul>\n<li>Material quality \u201cA\u201d: Usually construction steel of minimum quality S355 is used<\/li>\n<li>Plate thickness \u201cB\u201d: Depends on stiffness of total construction. Plate thickness of connecting surface must be at least 40 mm<\/li>\n<li>Surface quality \u201cC\u201d: Required mean roughness of the connecting surfaces is 6.3 \u03bcm<\/li>\n<li>Planeness \u201cD\u201d: Maximum admissible planeness tolerance within each connecting surface is 0.05 mm<\/li>\n<li>Angular deviation to vertical axis \u201cE\u201d: Angle deviation of connecting surface to the vertical axis in both planes must not exceed \u00b12\u00b0<\/li>\n<li>Plane parallelism \u201cF\u201d: Upper and lower connecting surfaces to the weighbeam must be plane-parallel to within 0.1 mm<\/li>\n<\/ul>\n<table>\n<tbody>\n<tr>\n<td width=\"106\"><strong>Variant<\/strong><\/td>\n<td width=\"106\"><strong>Order No.<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"106\">DMR 15 t 0.1<\/td>\n<td width=\"106\">V 000 522 .B01<\/td>\n<\/tr>\n<tr>\n<td width=\"106\">DMR 15 t C1<\/td>\n<td width=\"106\">upon request<\/td>\n<\/tr>\n<tr>\n<td width=\"106\">DMR 15 t C2<\/td>\n<td width=\"106\">upon request<\/td>\n<\/tr>\n<tr>\n<td width=\"106\">DMR 15 t<\/p>\n<p>2 channels<\/td>\n<td width=\"106\">upon request<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li><strong>High accuracy<\/strong><\/li>\n<li><strong>Hermetically sealed, protected to IP67 by laser welding<\/strong><\/li>\n<li><strong>\u00a0<\/strong><strong style=\"color: #65676b;\">Easy and economical installation through direct screwing to the con- necting structure<\/strong><\/li>\n<li><strong>\u00a0<\/strong><strong style=\"color: #65676b;\">Transmission of high interferential forces and moments at minimal influ- ence on measurement value<\/strong><\/li>\n<li><strong>For high temperatures and rugged operation<\/strong><\/li>\n<li><strong>\u00a0<\/strong><strong style=\"color: #65676b;\">For the design of maintenance-free scales<\/strong><\/li>\n<\/ul>\n","protected":false},"featured_media":286911,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5437],"product_cat":[3383],"product_tag":[5439,5134],"class_list":{"0":"post-286916","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-schenck-process","7":"product_cat-beam-type-load-cell","8":"product_tag-weighbeam-en","9":"product_tag--en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Schenck Process \/ Weighbeam DMR 15t - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"High accuracy  Hermetically sealed, protected to IP67 by laser welding  \u00a0Easy and economical installation through direct screwing to the con- necting structure  \u00a0Transmission of high interferential forces and moments at minimal influ- ence on measurement value  For high temperatures and rugged operation  \u00a0For the design of maintenance-free scales\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/product\/schenck-process-weighbeam-dmr-15t\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Schenck Process \/ Weighbeam DMR 15t\" \/>\n<meta property=\"og:description\" content=\"High accuracy  Hermetically sealed, protected to IP67 by laser welding  \u00a0Easy and economical installation through direct screwing to the con- necting structure  \u00a0Transmission of high interferential forces and moments at minimal influ- ence on measurement value  For high temperatures and rugged operation  \u00a0For the design of maintenance-free scales\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/product\/schenck-process-weighbeam-dmr-15t\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/SSMCC-Load-Cell-DMR-15t-BVD2170GB.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"411\" \/>\n\t<meta property=\"og:image:height\" content=\"278\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-weighbeam-dmr-15t\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-weighbeam-dmr-15t\\\/\",\"name\":\"Schenck Process \\\/ Weighbeam DMR 15t - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-weighbeam-dmr-15t\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-weighbeam-dmr-15t\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/SSMCC-Load-Cell-DMR-15t-BVD2170GB.jpeg\",\"datePublished\":\"2026-01-19T01:11:31+00:00\",\"description\":\"High accuracy Hermetically sealed, protected to IP67 by laser welding \u00a0Easy and economical installation through direct screwing to the con- necting structure \u00a0Transmission of high interferential forces and moments at minimal influ- ence on measurement value For high temperatures and rugged operation \u00a0For the design of maintenance-free scales\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-weighbeam-dmr-15t\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-weighbeam-dmr-15t\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-weighbeam-dmr-15t\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/SSMCC-Load-Cell-DMR-15t-BVD2170GB.jpeg\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/SSMCC-Load-Cell-DMR-15t-BVD2170GB.jpeg\",\"width\":411,\"height\":278},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/schenck-process-weighbeam-dmr-15t\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Schenck Process \\\/ Weighbeam DMR 15t\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/product\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Schenck Process \/ Weighbeam DMR 15t - CAS Scale Korea Co., Ltd.","description":"High accuracy  Hermetically sealed, protected to IP67 by laser welding  \u00a0Easy and economical installation through direct screwing to the con- necting structure  \u00a0Transmission of high interferential forces and moments at minimal influ- ence on measurement value  For high temperatures and rugged operation  \u00a0For the design of maintenance-free scales","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/product\/schenck-process-weighbeam-dmr-15t\/","og_locale":"en_US","og_type":"article","og_title":"Schenck Process \/ Weighbeam DMR 15t","og_description":"High accuracy  Hermetically sealed, protected to IP67 by laser welding  \u00a0Easy and economical installation through direct screwing to the con- necting structure  \u00a0Transmission of high interferential forces and moments at minimal influ- ence on measurement value  For high temperatures and rugged operation  \u00a0For the design of maintenance-free scales","og_url":"https:\/\/casscale.net\/en\/product\/schenck-process-weighbeam-dmr-15t\/","og_site_name":"CAS Scale Korea Co., Ltd.","og_image":[{"width":411,"height":278,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/SSMCC-Load-Cell-DMR-15t-BVD2170GB.jpeg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/product\/schenck-process-weighbeam-dmr-15t\/","url":"https:\/\/casscale.net\/en\/product\/schenck-process-weighbeam-dmr-15t\/","name":"Schenck Process \/ Weighbeam DMR 15t - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/product\/schenck-process-weighbeam-dmr-15t\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/product\/schenck-process-weighbeam-dmr-15t\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/SSMCC-Load-Cell-DMR-15t-BVD2170GB.jpeg","datePublished":"2026-01-19T01:11:31+00:00","description":"High accuracy Hermetically sealed, protected to IP67 by laser welding \u00a0Easy and economical installation through direct screwing to the con- necting structure \u00a0Transmission of high interferential forces and moments at minimal influ- ence on measurement value For high temperatures and rugged operation \u00a0For the design of maintenance-free scales","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/product\/schenck-process-weighbeam-dmr-15t\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/product\/schenck-process-weighbeam-dmr-15t\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/product\/schenck-process-weighbeam-dmr-15t\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/SSMCC-Load-Cell-DMR-15t-BVD2170GB.jpeg","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/SSMCC-Load-Cell-DMR-15t-BVD2170GB.jpeg","width":411,"height":278},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/product\/schenck-process-weighbeam-dmr-15t\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"Schenck Process \/ Weighbeam DMR 15t"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/product\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/286916","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=286916"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/286911"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=286916"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=286916"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=286916"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=286916"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}