{"id":287060,"date":"2026-01-19T16:33:28","date_gmt":"2026-01-19T07:33:28","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/scaime-ah-high-accuracy-aluminum-load-cell-50-kg-200-kg\/"},"modified":"2026-01-19T16:33:28","modified_gmt":"2026-01-19T07:33:28","slug":"scaime-ah-high-accuracy-aluminum-load-cell-50-kg-200-kg","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/scaime-ah-high-accuracy-aluminum-load-cell-50-kg-200-kg\/","title":{"rendered":"scaime \/ AH High accuracy aluminum load cell, 50 kg &#8230; 200 kg"},"content":{"rendered":"<h2>Single Point Load Cell AH with a Rated Load of 50 &#8230; 200 kg&lt;\/h2<\/h2>\n<p><strong>PRODUCT FEATURES<\/strong><\/p>\n<ul>\n<li>Aluminum single point load cell<\/li>\n<li>OIML R60 approved (6000d)<\/li>\n<li>Protection class: IP65<\/li>\n<li>Designed for platforms up to 500 mm \u00d7 500 mm (off-center load compensated)<\/li>\n<li>Low profile design<\/li>\n<li>ATEX 2014\/34\/EU version available for hazardous areas (optional)<\/li>\n<\/ul>\n<p><strong>APPLICATIONS<\/strong><\/p>\n<ul>\n<li>Food industry<\/li>\n<li>Coal and steel industry<\/li>\n<li>Chemical \/ pharmaceutical industry<\/li>\n<li>Waste management \/ recycling<\/li>\n<li>Packaging technology<\/li>\n<\/ul>\n<p><strong>Dimensions in mm<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-287058\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/AH-1.png\" alt=\"\" width=\"1639\" height=\"1013\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/AH-1.png 1639w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/AH-1-647x400.png 647w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/AH-1-1294x800.png 1294w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/AH-1-768x475.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/AH-1-1536x949.png 1536w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/AH-1-600x371.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/AH-1-64x40.png 64w\" sizes=\"(max-width: 1639px) 100vw, 1639px\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Article-No.<\/th>\n<th>Version<\/th>\n<th>Rated load [kg]<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>100215<\/td>\n<td>C3 5e<\/td>\n<td>5<\/td>\n<\/tr>\n<tr>\n<td>100298<\/td>\n<td>C3 10e<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>101076<\/td>\n<td>C3 10e<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<td>100300<\/td>\n<td>C3 10e<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td>101077<\/td>\n<td>C3 10e<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<td>100302<\/td>\n<td>C3 10e<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>100889<\/td>\n<td>C3 10e<\/td>\n<td>75<\/td>\n<\/tr>\n<tr>\n<td>100304<\/td>\n<td>C3 10e<\/td>\n<td>100<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Connection Assignment<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Electrical Connection Function<\/th>\n<th>Wire Color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Excitation (+)<\/td>\n<td>Brown<\/td>\n<\/tr>\n<tr>\n<td>Signal (+)<\/td>\n<td>Yellow<\/td>\n<\/tr>\n<tr>\n<td>Signal (\u2013)<\/td>\n<td>White<\/td>\n<\/tr>\n<tr>\n<td>Excitation (\u2013)<\/td>\n<td>Green<\/td>\n<\/tr>\n<tr>\n<td>Sensing (+)<\/td>\n<td>Gray<\/td>\n<\/tr>\n<tr>\n<td>Sensing (\u2013)<\/td>\n<td>Pink<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Technical Data<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Unit<\/th>\n<th>Version C3 10e<\/th>\n<th>Version C6 10e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Type<\/td>\n<td>\u2013<\/td>\n<td>AH<\/td>\n<td>AH<\/td>\n<\/tr>\n<tr>\n<td>Rated load (E)<\/td>\n<td>kg<\/td>\n<td>50 \/ 100 \/ 200<\/td>\n<td>50 \/ 100 \/ 200<\/td>\n<\/tr>\n<tr>\n<td>Maximum load for approved weighing (Emax)<\/td>\n<td>kg<\/td>\n<td>50 \/ 100 \/ 200<\/td>\n<td>50 \/ 100 \/ 200<\/td>\n<\/tr>\n<tr>\n<td>Accuracy class (OIML R60)<\/td>\n<td>\u2013<\/td>\n<td>C3<\/td>\n<td>C6<\/td>\n<\/tr>\n<tr>\n<td>Max. number of LC intervals (nmax)<\/td>\n<td>d OIML<\/td>\n<td>3000<\/td>\n<td>6000<\/td>\n<\/tr>\n<tr>\n<td>Minimum verification interval (vmin)<\/td>\n<td>g<\/td>\n<td>5 \/ 10 \/ 20<\/td>\n<td>5 \/ 10 \/ 20<\/td>\n<\/tr>\n<tr>\n<td>Creep division factor Z = Emax \/ 2\u00d7DR<\/td>\n<td>\u2013<\/td>\n<td>3000<\/td>\n<td>6000<\/td>\n<\/tr>\n<tr>\n<td>Combined error<\/td>\n<td>% E<\/td>\n<td>\u00b10.017<\/td>\n<td>\u00b10.008<\/td>\n<\/tr>\n<tr>\n<td>Temp. coefficient of zero signal<\/td>\n<td>% E \/ \u00b0C<\/td>\n<td>\u00b10.0014<\/td>\n<td>\u00b10.0014<\/td>\n<\/tr>\n<tr>\n<td>Temp. coefficient of sensitivity<\/td>\n<td>% E \/ \u00b0C<\/td>\n<td>\u00b10.0014<\/td>\n<td>\u00b10.0007<\/td>\n<\/tr>\n<tr>\n<td>Load creep (30 min)<\/td>\n<td>% E<\/td>\n<td>\u00b10.025<\/td>\n<td>\u00b10.012<\/td>\n<\/tr>\n<tr>\n<td>Zero balance<\/td>\n<td>% E<\/td>\n<td>\u00b110<\/td>\n<td>\u00b110<\/td>\n<\/tr>\n<tr>\n<td>Rated output (Cnom)<\/td>\n<td>mV\/V<\/td>\n<td>2 \u00b110%<\/td>\n<td>2 \u00b110%<\/td>\n<\/tr>\n<tr>\n<td>Rated excitation voltage range<\/td>\n<td>V<\/td>\n<td>1 \u2026 15<\/td>\n<td>1 \u2026 15<\/td>\n<\/tr>\n<tr>\n<td>Input resistance (Re)<\/td>\n<td>\u03a9<\/td>\n<td>410 \u00b120<\/td>\n<td>410 \u00b120<\/td>\n<\/tr>\n<tr>\n<td>Output resistance (Ra)<\/td>\n<td>\u03a9<\/td>\n<td>350 \u00b15<\/td>\n<td>350 \u00b15<\/td>\n<\/tr>\n<tr>\n<td>Insulation resistance<\/td>\n<td>M\u03a9 \/ 50V<\/td>\n<td>1000<\/td>\n<td>1000<\/td>\n<\/tr>\n<tr>\n<td>Electrical connection<\/td>\n<td>\u2013<\/td>\n<td>Cable, PVC, 3 m<\/td>\n<td>Cable, PVC, 3 m<\/td>\n<\/tr>\n<tr>\n<td>Compensated temperature range<\/td>\n<td>\u00b0C<\/td>\n<td>\u201310 \u2026 +40<\/td>\n<td>\u201310 \u2026 +40<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature range<\/td>\n<td>\u00b0C<\/td>\n<td>\u201320 \u2026 +60<\/td>\n<td>\u201320 \u2026 +60<\/td>\n<\/tr>\n<tr>\n<td>Safe load limit<\/td>\n<td>% Emax<\/td>\n<td>150<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>Breaking load<\/td>\n<td>% Emax<\/td>\n<td>200<\/td>\n<td>200<\/td>\n<\/tr>\n<tr>\n<td>Tightening torque<\/td>\n<td>Nm<\/td>\n<td>15<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<td>Max. platform size<\/td>\n<td>mm<\/td>\n<td>500 \u00d7 500<\/td>\n<td>500 \u00d7 500<\/td>\n<\/tr>\n<tr>\n<td>Protection class<\/td>\n<td>\u2013<\/td>\n<td>IP65<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>Material<\/td>\n<td>\u2013<\/td>\n<td>Aluminum<\/td>\n<td>Aluminum<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>kg<\/td>\n<td>0.6<\/td>\n<td>0.6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Options<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Article-No.<\/th>\n<th>Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>111735<\/td>\n<td>Protective coating<\/td>\n<\/tr>\n<tr>\n<td>107798<\/td>\n<td>ATEX 2014\/34\/EU, IECEx: Ex II 1 G\/D \u2022 Ex ia IIC T6 Ga \u2022 Ex ia IIIC T80 \u00b0C Da \u2022 IP6X \u2022 -20 \u00b0C &lt; Ta &lt; +60 \u00b0C (Gas zones 0\/1\/2, Dust zones 20\/21\/22)<\/td>\n<\/tr>\n<tr>\n<td>115049<\/td>\n<td>ATEX 2014\/34\/EU, IECEx: Ex II 1 D \u2022 Ex ta IIIC T125 \u00b0C Da \u2022 IP6X \u2022 -20 \u00b0C &lt; Ta &lt; +60 \u00b0C (Dust zones 20\/21\/22)<\/td>\n<\/tr>\n<tr>\n<td>115048<\/td>\n<td>ATEX 2014\/34\/EU, IECEx: Ex II 3 G \u2022 Ex nA IIC T6 Gc \u2022 -20 \u00b0C &lt; Ta &lt; +60 \u00b0C (Gas zone 2)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Electrical Connection<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Article-No.<\/th>\n<th>Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>10323<\/td>\n<td>Male cable connector KS6 (6-pin, Series 581) incl. mounting<\/td>\n<\/tr>\n<tr>\n<td>10320<\/td>\n<td>Male cable connector KSSH15 (15-pin) incl. mounting<\/td>\n<\/tr>\n<tr>\n<td>43418<\/td>\n<td>Input connector ZA9612FS (ALMEMO) incl. sensor mounting and connector calibration<\/td>\n<\/tr>\n<tr>\n<td>49205<\/td>\n<td>Input connector ZKD712FS (ALMEMO 202) incl. sensor mounting and connector calibration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li>Load cell made of aluminum,\u00a0IP65 protection level<\/li>\n<li>approved up to 6 000 d OIML R60 for use in legal for trade weighing applications<\/li>\n<li>Maximum platform size\u00a0500&#215;500 mm<\/li>\n<li>Ideally suited for single-cell weighing scales construction<\/li>\n<li>Capacities: 50, 100, 200 kg<\/li>\n<\/ul>\n","protected":false},"featured_media":287057,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5442],"product_cat":[3375,3385],"product_tag":[4626,5445],"class_list":{"0":"post-287060","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-scaime","7":"product_cat-digital-load-cell","8":"product_cat-single-point-en","9":"product_tag-single-point-en-2","10":"product_tag--en","12":"first","13":"instock","14":"taxable","15":"shipping-taxable","16":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/287060","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=287060"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/287057"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=287060"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=287060"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=287060"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=287060"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}