{"id":287066,"date":"2026-01-19T16:45:45","date_gmt":"2026-01-19T07:45:45","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/scaime-single-point-load-cell-ap-with-a-rated-load-of-75-635-kg\/"},"modified":"2026-01-19T16:45:45","modified_gmt":"2026-01-19T07:45:45","slug":"scaime-single-point-load-cell-ap-with-a-rated-load-of-75-635-kg","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/scaime-single-point-load-cell-ap-with-a-rated-load-of-75-635-kg\/","title":{"rendered":"scaime \/ Single Point Load Cell AP with a Rated Load of 75 &#8230; 635 kg"},"content":{"rendered":"<h2>Single Point Load Cell AP with a Rated Load of 75 &#8230; 635 kg<\/h2>\n<p><strong>PRODUCT FEATURES<\/strong><\/p>\n<ul>\n<li>Aluminum single point load cell<\/li>\n<li>OIML R60 approved (3000d) and NTEP approved (5000d)<\/li>\n<li>Protection class: IP65<\/li>\n<li>Designed for platforms up to 700 mm \u00d7 700 mm (off-center load compensated)<\/li>\n<li>Super flat construction<\/li>\n<li>ATEX 2014\/34\/EU version available for hazardous areas (optional)<\/li>\n<\/ul>\n<p><strong>APPLICATIONS<\/strong><\/p>\n<ul>\n<li>Food industry<\/li>\n<li>Coal and steel industry<\/li>\n<li>Chemical \/ pharmaceutical industry<\/li>\n<li>Waste management \/ recycling<\/li>\n<li>Packaging technology<\/li>\n<\/ul>\n<p><strong> Dimensions in mm<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-287064\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/AP.png\" alt=\"\" width=\"1462\" height=\"933\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/AP.png 1462w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/AP-627x400.png 627w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/AP-1254x800.png 1254w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/AP-768x490.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/AP-600x383.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/AP-64x41.png 64w\" sizes=\"(max-width: 1462px) 100vw, 1462px\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Article-No.<\/th>\n<th>Version<\/th>\n<th>Rated Load (kg)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>106044<\/td>\n<td>C3 10e<\/td>\n<td>75<\/td>\n<\/tr>\n<tr>\n<td>106045<\/td>\n<td>C3 10e<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<td>106046<\/td>\n<td>C3 10e<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>111398<\/td>\n<td>C3 10e<\/td>\n<td>200<\/td>\n<\/tr>\n<tr>\n<td>109360<\/td>\n<td>C3 10e<\/td>\n<td>300<\/td>\n<\/tr>\n<tr>\n<td>106050<\/td>\n<td>C3 10e<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<td>106051<\/td>\n<td>C3 10e<\/td>\n<td>635<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Connection Assignment<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Function<\/th>\n<th>Wire Color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Excitation (+)<\/td>\n<td>Brown<\/td>\n<\/tr>\n<tr>\n<td>Signal (+)<\/td>\n<td>Yellow<\/td>\n<\/tr>\n<tr>\n<td>Signal (\u2212)<\/td>\n<td>White<\/td>\n<\/tr>\n<tr>\n<td>Excitation (\u2212)<\/td>\n<td>Green<\/td>\n<\/tr>\n<tr>\n<td>Sensing (+)<\/td>\n<td>Gray<\/td>\n<\/tr>\n<tr>\n<td>Sensing (\u2212)<\/td>\n<td>Pink<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Technical Data<\/strong><\/p>\n<table>\n<thead>\n<\/thead>\n<tbody>\n<tr>\n<td>Type<\/td>\n<td>AP<\/td>\n<\/tr>\n<tr>\n<td>Version<\/td>\n<td>C3 10e<\/td>\n<\/tr>\n<tr>\n<td>Rated load (E)<\/td>\n<td>75; 100; 150; 200; 300; 500; 635 kg<\/td>\n<\/tr>\n<tr>\n<td>Maximum load for approved weighing (Emax)<\/td>\n<td>75; 100; 150; 200; 300; 500; 635 kg<\/td>\n<\/tr>\n<tr>\n<td>Accuracy class<\/td>\n<td>OIML R60 C3<\/td>\n<\/tr>\n<tr>\n<td>Maximum numbers of load cell intervals (nmax)<\/td>\n<td>3000 d OIML<\/td>\n<\/tr>\n<tr>\n<td>Minimum verification interval (vmin)<\/td>\n<td>E \/ 10000 kg<\/td>\n<\/tr>\n<tr>\n<td>Creep division factor (Z = Emax \/ 2 \\times DR)<\/td>\n<td>3000<\/td>\n<\/tr>\n<tr>\n<td>Combined error<\/td>\n<td>\u00b10.017 % E<\/td>\n<\/tr>\n<tr>\n<td>Temperature coefficient of zero signal<\/td>\n<td>\u00b10.0014 % E \/ \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature coefficient of characteristic value<\/td>\n<td>\u00b10.0014 % E \/ \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Load creep (dcr, F) in 30 min.<\/td>\n<td>\u00b10.025 % E<\/td>\n<\/tr>\n<tr>\n<td>Zero balance<\/td>\n<td>\u00b110 % E<\/td>\n<\/tr>\n<tr>\n<td>Rated output at E (Cnom)<\/td>\n<td>2 \u00b110 % mV\/V<\/td>\n<\/tr>\n<tr>\n<td>Rated range of excitation voltage (BU, nom)<\/td>\n<td>1 &#8230; 15 V<\/td>\n<\/tr>\n<tr>\n<td>Input resistance (Re)<\/td>\n<td>410 \u00b120 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Output resistance (Ra)<\/td>\n<td>350 \u00b15 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Insulation resistance (Ris)<\/td>\n<td>1000 M\u03a9 \/ 50 V<\/td>\n<\/tr>\n<tr>\n<td>Electrical connection<\/td>\n<td>Cable, PVC, 3 m<\/td>\n<\/tr>\n<tr>\n<td>Rated temperature range (BT, nom)<\/td>\n<td>-10 &#8230; 40\u202f\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature range (BT, G)<\/td>\n<td>-20 &#8230; 60\u202f\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Limit load (Elim)<\/td>\n<td>150 % Emax<\/td>\n<\/tr>\n<tr>\n<td>Breaking load (Eb)<\/td>\n<td>200 % Emax<\/td>\n<\/tr>\n<tr>\n<td>Tightening torque<\/td>\n<td>40 Nm<\/td>\n<\/tr>\n<tr>\n<td>Maximum platform dimension<\/td>\n<td>700 x 700 mm<\/td>\n<\/tr>\n<tr>\n<td>Level of protection<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>Material<\/td>\n<td>Aluminium<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>1.6 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Options<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Article No.<\/th>\n<th>Description<\/th>\n<th>Notes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>111735<\/td>\n<td>Protective coating<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>107798<\/td>\n<td>ATEX 2014\/34\/EU, IECEx: ex II 1 G\/D, Ex ia IIC T6 Ga, Ex ia IIIC T80\u202f\u00b0C Da, IP6X<\/td>\n<td>-20\u202f\u00b0C &lt; Ta &lt; +60\u202f\u00b0C (zones gaz 0\/1\/2, dust 20\/21\/22)<\/td>\n<\/tr>\n<tr>\n<td>115049<\/td>\n<td>ATEX 2014\/34\/EU, IECEx: ex II 1 D, Ex ta IIIC T125\u202f\u00b0C Da, IP6X<\/td>\n<td>-20\u202f\u00b0C &lt; Ta &lt; +60\u202f\u00b0C (zones dust 20\/21\/22)<\/td>\n<\/tr>\n<tr>\n<td>115048<\/td>\n<td>ATEX 2014\/34\/EU, IECEx: ex II 3 G, Ex nA IIC T6 Gc<\/td>\n<td>-20\u202f\u00b0C &lt; Ta &lt; +60\u202f\u00b0C (zone gaz 2)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Electrical Connection<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Article No.<\/th>\n<th>Connector Name \/ Description<\/th>\n<th>Notes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>10323<\/td>\n<td>KS6 (6-pin, Series 581) Male cable connector<\/td>\n<td>incl. mounting<\/td>\n<\/tr>\n<tr>\n<td>10320<\/td>\n<td>KSSH15 (15-pin) Male cable connector<\/td>\n<td>incl. mounting<\/td>\n<\/tr>\n<tr>\n<td>43418<\/td>\n<td>ZA9612FS ALMEMO Input connector<\/td>\n<td>incl. sensor mounting and connector calibration<\/td>\n<\/tr>\n<tr>\n<td>49205<\/td>\n<td>ZKD712FS ALMEMO 202 Input connector<\/td>\n<td>incl. sensor mounting and connector calibration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li>High capacity load cell made of aluminum,\u00a0IP65 protection level<\/li>\n<li>Approved up to\u00a03 000 d OIML R60\u00a0and\u00a05 000 d NTEP for use in legal for trade weighing applications<\/li>\n<li>Maximum scale platform size\u00a0700&#215;700 mm<\/li>\n<li>Flat construction, ideally suited for single-cell weighing platform<\/li>\n<\/ul>\n","protected":false},"featured_media":287063,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5442],"product_cat":[3375,3385],"product_tag":[4626,5445],"class_list":{"0":"post-287066","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-scaime","7":"product_cat-digital-load-cell","8":"product_cat-single-point-en","9":"product_tag-single-point-en-2","10":"product_tag--en","12":"first","13":"instock","14":"taxable","15":"shipping-taxable","16":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/287066","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=287066"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/287063"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=287066"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=287066"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=287066"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=287066"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}