{"id":287070,"date":"2026-01-19T16:59:21","date_gmt":"2026-01-19T07:59:21","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/scaime-ab-aluminum-single-point-load-cell-50-kg-500-kg\/"},"modified":"2026-01-19T17:19:55","modified_gmt":"2026-01-19T08:19:55","slug":"scaime-ab-aluminum-single-point-load-cell-50-kg-500-kg","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/scaime-ab-aluminum-single-point-load-cell-50-kg-500-kg\/","title":{"rendered":"scaime \/ BEF-F \/ PM Single point load cell for wall-mounting, 150 kg"},"content":{"rendered":"<h2>Single Point Load Cell BEF-F with a Rated Load of 150 kg<\/h2>\n<table>\n<thead><\/thead>\n<tbody>\n<tr>\n<td>Product Type<\/td>\n<td>Single point load cell<\/td>\n<\/tr>\n<tr>\n<td>Material<\/td>\n<td>Anodized aluminum<\/td>\n<\/tr>\n<tr>\n<td>Protection Level<\/td>\n<td>IP67<\/td>\n<\/tr>\n<tr>\n<td>Platform Compatibility<\/td>\n<td>Maximum dimensions 600 mm x 600 mm (off-center load compensated)<\/td>\n<\/tr>\n<tr>\n<td>Technology<\/td>\n<td>6-wire<\/td>\n<\/tr>\n<tr>\n<td>Environmental Suitability<\/td>\n<td>Harsh environments<\/td>\n<\/tr>\n<tr>\n<td>Application Areas<\/td>\n<td>Food industry, Coal and steel industry, Chemical \/ pharmaceutical industry, Waste management \/ recycling, Packaging technology<\/td>\n<\/tr>\n<tr>\n<td>Mounting<\/td>\n<td>Side mounting (suitable for tank weighing)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Dimensions in mm<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-287072\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PM.png\" alt=\"\" width=\"1534\" height=\"841\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PM.png 1534w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PM-730x400.png 730w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PM-1400x768.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PM-768x421.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PM-600x329.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PM-64x35.png 64w\" sizes=\"(max-width: 1534px) 100vw, 1534px\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Article No.<\/th>\n<th>Version<\/th>\n<th>Rated Load [kg]<\/th>\n<th>Connection Assignment<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>112391<\/td>\n<td>\u2013<\/td>\n<td>150<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Connection Assignment<\/strong><\/p>\n<p>&nbsp;<\/p>\n<table>\n<thead>\n<tr>\n<th>Function<\/th>\n<th>Wire Color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Excitation (+)<\/td>\n<td>Red<\/td>\n<\/tr>\n<tr>\n<td>Signal (+)<\/td>\n<td>Green<\/td>\n<\/tr>\n<tr>\n<td>Signal (-)<\/td>\n<td>White<\/td>\n<\/tr>\n<tr>\n<td>Excitation (-)<\/td>\n<td>Blue<\/td>\n<\/tr>\n<tr>\n<td>Sensing (+)<\/td>\n<td>Pink<\/td>\n<\/tr>\n<tr>\n<td>Sensing (-)<\/td>\n<td>Gray<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Technical Data<\/strong><\/p>\n<table>\n<thead><\/thead>\n<tbody>\n<tr>\n<td>Type<\/td>\n<td>PM<\/td>\n<\/tr>\n<tr>\n<td>Version<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Rated load (E)<\/td>\n<td>150 kg<\/td>\n<\/tr>\n<tr>\n<td>Maximum load for approved weighing (Emax)<\/td>\n<td>150 kg<\/td>\n<\/tr>\n<tr>\n<td>Accuracy class<\/td>\n<td>OIML R60<\/td>\n<\/tr>\n<tr>\n<td>Maximum numbers of load cell intervals (nmax)<\/td>\n<td>d OIML<\/td>\n<\/tr>\n<tr>\n<td>Minimum verification interval (vmin)<\/td>\n<td>g<\/td>\n<\/tr>\n<tr>\n<td>Creep division factor (Z = Emax \/ 2 \\times DR)<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Combined error<\/td>\n<td>\u00b10.033 % E<\/td>\n<\/tr>\n<tr>\n<td>Temperature coefficient of zero signal<\/td>\n<td>\u00b10.006 % E \/ \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature coefficient of characteristic value<\/td>\n<td>\u00b10.0016 % E \/ \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Load creep (dcr, F) in 30 min.<\/td>\n<td>\u00b10.03 % E<\/td>\n<\/tr>\n<tr>\n<td>Zero balance<\/td>\n<td>\u00b15 % E<\/td>\n<\/tr>\n<tr>\n<td>Rated output at E (Cnom)<\/td>\n<td>1.2 \u00b110 % mV\/V<\/td>\n<\/tr>\n<tr>\n<td>Rated range of excitation voltage (BU, nom)<\/td>\n<td>1 &#8230; 15 V<\/td>\n<\/tr>\n<tr>\n<td>Input resistance (Re)<\/td>\n<td>410 \u00b120 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Output resistance (Ra)<\/td>\n<td>350 \u00b15 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Insulation resistance (Ris)<\/td>\n<td>5 M\u03a9 \/ 50 V<\/td>\n<\/tr>\n<tr>\n<td>Electrical connection<\/td>\n<td>Cable, PVC, 3 m<\/td>\n<\/tr>\n<tr>\n<td>Rated temperature range (BT, nom)<\/td>\n<td>-10 &#8230; 40\u202f\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature range (BT, G)<\/td>\n<td>-20 &#8230; 60\u202f\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Limit load (Elim)<\/td>\n<td>150 % Emax<\/td>\n<\/tr>\n<tr>\n<td>Breaking load (Eb)<\/td>\n<td>200 % Emax<\/td>\n<\/tr>\n<tr>\n<td>Tightening torque<\/td>\n<td>40 Nm<\/td>\n<\/tr>\n<tr>\n<td>Maximum platform dimension<\/td>\n<td>600 x 600 mm<\/td>\n<\/tr>\n<tr>\n<td>Level of protection<\/td>\n<td>IP67<\/td>\n<\/tr>\n<tr>\n<td>Material<\/td>\n<td>Aluminum<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>1.25 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Options<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Article No.<\/th>\n<th>Product \/ Description<\/th>\n<th>Notes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>111735<\/td>\n<td>Protective coating<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Electrical Connection<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Article No.<\/th>\n<th>Product \/ Description<\/th>\n<th>Notes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>10323<\/td>\n<td>Male cable connector KS6 (6-pin, Series 581)<\/td>\n<td>incl. mounting<\/td>\n<\/tr>\n<tr>\n<td>10320<\/td>\n<td>Male cable connector KSSH15 (15-pin)<\/td>\n<td>incl. mounting<\/td>\n<\/tr>\n<tr>\n<td>43418<\/td>\n<td>Input connector ZA9612FS (ALMEMO)<\/td>\n<td>incl. sensor mounting and connector calibration<\/td>\n<\/tr>\n<tr>\n<td>49205<\/td>\n<td>Input connector ZKD712FS (ALMEMO 202)<\/td>\n<td>incl. sensor mounting and connector calibration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li>Load cell made of anodized aluminum,\u00a0IP67 protection level<\/li>\n<li>Designed for use in harsh environments<\/li>\n<li>Max. weighing platform size\u00a0600&#215;600 mm<\/li>\n<li>Suited for tank weighing with wall mounting<\/li>\n<\/ul>\n","protected":false},"featured_media":287077,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5442],"product_cat":[3375,3385],"product_tag":[4626,5445],"class_list":{"0":"post-287070","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-scaime","7":"product_cat-digital-load-cell","8":"product_cat-single-point-en","9":"product_tag-single-point-en-2","10":"product_tag--en","12":"first","13":"instock","14":"taxable","15":"shipping-taxable","16":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/287070","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=287070"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/287077"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=287070"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=287070"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=287070"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=287070"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}