{"id":287176,"date":"2026-01-22T10:44:36","date_gmt":"2026-01-22T01:44:36","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\/"},"modified":"2026-01-22T10:44:36","modified_gmt":"2026-01-22T01:44:36","slug":"minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/products\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\/","title":{"rendered":"Minebea intec \/ Compression load cell Inteco\u00ae, converter  Connexx\u00ae,  mounting kits PR 600x, PR 614x"},"content":{"rendered":"<h2>Compression load cell Inteco\u00ae, converter Connexx\u00ae, mounting kits PR 600x, PR 614x<\/h2>\n<p>The versatile, innovative weighing solution for silo and vessel weighing<\/p>\n<p><em>The<\/em> <em>load<\/em> <em>cells<\/em> <em>of<\/em> <em>the<\/em> <em>Inteco<\/em><em>\u00ae<\/em><em>\u00a0<\/em><em>(PR<\/em> <em>6203)<\/em> <em>series<\/em> <em>have<\/em> <em>been<\/em> <em>specially<\/em> <em>designed<\/em> <em>for <\/em><em>weighing<\/em> <em>silos,<\/em> <em>tanks<\/em> <em>and<\/em> <em>process<\/em> <em>vessels.<\/em> <em>Their<\/em> <em>unique<\/em> <em>construction<\/em> <em>principle,<\/em> <em>in conjunction<\/em> <em>with<\/em> <em>the<\/em> <em>FlexLock<\/em> <em>mounting<\/em> <em>kits,<\/em> <em>makes<\/em> <em>it<\/em> <em>possible<\/em> <em>to<\/em> <em>compensate<\/em> <em>for <\/em><em>lateral forces.<\/em><\/p>\n<h4 style=\"line-height: 105%; margin: 0cm 201.5pt .0001pt 7.35pt;\"><span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.1pt;\">Unrivalled<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.1pt;\">reliability,<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.1pt;\">robustness<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.1pt;\">and<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.1pt;\">stability<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.1pt;\">for<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.1pt;\">your <\/span><span lang=\"EN-US\" style=\"color: #4c4d4f;\">silo and process vessel weighing<\/span><\/h4>\n<p>&nbsp;<\/p>\n<ul>\n<li>\u00a0With maximum capacities from 500 kg to 75 t, accuracy classes from D1 to C6 and EX versions, almost all applications are possible.<\/li>\n<li>\u00a0The pendulum support principle ensures there is always optimal force transmission into the sensor and thus minimises the influence on measuring accuracy, whilst also offering a large overload capacity, very high repeatability error and perfect linearity.<\/li>\n<li>\u00a0With the FlexLock mounting kits, it is possible to compensate for movements arising from mechanical or thermal contraction or expansion of the container or the support structure.<\/li>\n<li>\u00a0Thanks to the use of stainless steel in the housing and measuring elements and the top IP68\/IP69 protection class, the cell holds its own even in adverse conditions.<\/li>\n<\/ul>\n<h4 style=\"margin-top: 6.15pt;\"><span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.4pt;\">Technical<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.1pt;\">specifications<\/span><\/h4>\n<table>\n<tbody>\n<tr>\n<td width=\"136\">Parameter<\/td>\n<td width=\"215\">Description<\/td>\n<td width=\"38\">Abbr.<\/td>\n<td width=\"70\">PR 6203 D1\/N<\/td>\n<td width=\"66\">PR 6203 C3<\/td>\n<td width=\"66\">PR 6203 C6<\/td>\n<td width=\"51\">Unit<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Accuracy class<\/td>\n<td width=\"215\">&nbsp;<\/td>\n<td width=\"38\">&nbsp;<\/td>\n<td width=\"70\">0.04<\/td>\n<td width=\"66\">0.015<\/td>\n<td width=\"66\">0.008<\/td>\n<td width=\"51\">%Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Minimum dead load<\/td>\n<td width=\"215\">Lowest limit of specified measuring range<\/td>\n<td width=\"38\">Emin<\/td>\n<td colspan=\"3\" width=\"202\">0<\/td>\n<td width=\"51\">%Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Maximum capacity<\/td>\n<td width=\"215\">Highest limit of specified measuring range<\/td>\n<td width=\"38\">Emax<\/td>\n<td colspan=\"3\" width=\"202\">See Ordering information table<\/td>\n<td width=\"51\">kg<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Safe load limit<\/td>\n<td width=\"215\">Maximum load without irreversible damage<\/td>\n<td width=\"38\">Elim<\/td>\n<td colspan=\"3\" width=\"202\">For 500 kg \u2026 50 t: 150<\/p>\n<p>For 60 t:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 125<\/p>\n<p>For 75 t:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 100<\/td>\n<td width=\"51\">%Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Destructive load<\/td>\n<td width=\"215\">Danger of mechanical destruction<\/td>\n<td width=\"38\">E<sub>d<\/sub><\/td>\n<td colspan=\"3\" width=\"202\">For 500 kg \u2026 50 t: &gt;300<\/p>\n<p>For 60 t:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 &gt;250<\/p>\n<p>For 75 t:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 &gt;200<\/td>\n<td width=\"51\">%Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Minimum LC verification<\/td>\n<td width=\"215\">Minimum load cell verification interval (v<sub>min<\/sub> = E<sub>max<\/sub>\/Y)<\/td>\n<td width=\"38\">&nbsp;<\/td>\n<td colspan=\"3\" width=\"202\">See Accuracy classes and minimum verification interval, v<sub>min<\/sub> table<\/td>\n<td width=\"51\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">&nbsp;<\/td>\n<td width=\"215\">For E<sub>max<\/sub> = 500 kg<\/td>\n<td width=\"38\">Y<\/td>\n<td width=\"70\">2,500<\/td>\n<td width=\"66\">n.a.<\/td>\n<td width=\"66\">n.a.<\/td>\n<td width=\"51\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">&nbsp;<\/td>\n<td width=\"215\">For E<sub>max<\/sub> = 1 t<\/td>\n<td width=\"38\">Y<\/td>\n<td width=\"70\">5,000<\/td>\n<td width=\"66\">n.a.<\/td>\n<td width=\"66\">n.a.<\/td>\n<td width=\"51\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">&nbsp;<\/td>\n<td width=\"215\">For E<sub>max<\/sub> = 2 t<\/td>\n<td width=\"38\">Y<\/td>\n<td width=\"70\">5,000<\/td>\n<td width=\"66\">10,000<\/td>\n<td width=\"66\">n.a.<\/td>\n<td width=\"51\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">&nbsp;<\/td>\n<td width=\"215\">For E<sub>max<\/sub> = 3 t \u2026 75 t<\/td>\n<td width=\"38\">Y<\/td>\n<td width=\"70\">5,000<\/td>\n<td width=\"66\">14,000<\/td>\n<td width=\"66\">3 t \u2013 10 t:<\/p>\n<p>14,000<\/p>\n<p>\u226520 t: 20,000<\/td>\n<td width=\"51\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Deadload output return<\/td>\n<td width=\"215\">Factor for deadload output return after load (DR=1\/2*E<sub>max<\/sub>\/Z)<\/td>\n<td width=\"38\">Z<\/td>\n<td width=\"70\">1,000<\/td>\n<td width=\"66\">3,000<\/td>\n<td width=\"66\">6,000<\/td>\n<td width=\"51\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Rated output<\/td>\n<td width=\"215\">Relative output at maximum capacity<\/td>\n<td width=\"38\">C<sub>n<\/sub><\/td>\n<td width=\"70\">2<\/td>\n<td width=\"66\">2<\/td>\n<td width=\"66\">2<\/td>\n<td width=\"51\">mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Tolerance on rated output<\/td>\n<td width=\"215\">Permissible deviation from rated output<\/td>\n<td width=\"38\">d<sub>c<\/sub><\/td>\n<td width=\"70\">&lt;0.25<\/td>\n<td width=\"66\">&lt;0.07<\/td>\n<td width=\"66\">&lt;0.07<\/td>\n<td width=\"51\">%C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Zero output signal<\/td>\n<td width=\"215\">Load cell output signal under unloaded condition<\/td>\n<td width=\"38\">Smin<\/td>\n<td width=\"70\">0\u00b11.0<\/td>\n<td width=\"66\">0\u00b11.0<\/td>\n<td width=\"66\">0\u00b11.0<\/td>\n<td width=\"51\">%C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Reproducibility<\/td>\n<td width=\"215\">Max. change in load cell output for repeated loading<\/td>\n<td width=\"38\">eR<\/td>\n<td width=\"70\">0.01<\/td>\n<td width=\"66\">0.005<\/td>\n<td width=\"66\">0.005<\/td>\n<td width=\"51\">%C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Creep<\/td>\n<td width=\"215\">Max. change of output signal at E<sub>max<\/sub> for 30 min.<\/td>\n<td width=\"38\">dcr<\/td>\n<td width=\"70\">&lt;0.03<\/td>\n<td width=\"66\">&lt;0.015<\/td>\n<td width=\"66\">&lt;0.008<\/td>\n<td width=\"51\">%C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Non-linearity1)<\/td>\n<td width=\"215\">Max. deviation from best straight line through zero<\/td>\n<td width=\"38\">dLin<\/td>\n<td width=\"70\">&lt;0.03<\/td>\n<td width=\"66\">&lt;0.01<\/td>\n<td width=\"66\">&lt;0.01<\/td>\n<td width=\"51\">%C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Hysteresis1)<\/td>\n<td width=\"215\">Max. difference in LC output between loading and unloading<\/td>\n<td width=\"38\">dhy<\/td>\n<td width=\"70\">&lt;0.04<\/td>\n<td width=\"66\">&lt;0.015<\/td>\n<td width=\"66\">&lt;0.008<\/td>\n<td width=\"51\">%C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Temperature effect (TK) on S<sub>min<\/sub><\/td>\n<td width=\"215\">Max. change of S<sub>min<\/sub> in B<sub>T<\/sub><\/td>\n<td width=\"38\">TKSmin<\/td>\n<td width=\"70\">&lt;0.028<\/td>\n<td width=\"66\">&lt;0.010<\/td>\n<td width=\"66\">&lt;0.007<\/td>\n<td width=\"51\">%C<sub>n<\/sub>\/10 K<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Temperature effect (TK) on parameter1)<\/td>\n<td width=\"215\">Max. change of C in B<sub>T<\/sub><\/td>\n<td width=\"38\">TK<sub>C<\/sub><\/td>\n<td width=\"70\">&lt;0.03<\/td>\n<td width=\"66\">&lt;0.010<\/td>\n<td width=\"66\">&lt;0.005<\/td>\n<td width=\"51\">%C<sub>n<\/sub>\/10 K<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Input impedance<\/td>\n<td width=\"215\">Between supply terminals<\/td>\n<td width=\"38\">RLC<\/td>\n<td width=\"70\">650 \u00b16<\/td>\n<td width=\"66\">650 \u00b16<\/td>\n<td width=\"66\">650 \u00b16<\/td>\n<td width=\"51\">\u2126<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Output impedance<\/td>\n<td width=\"215\">Between measuring terminals<\/td>\n<td width=\"38\">R<sub>O<\/sub><\/td>\n<td width=\"70\">610 \u00b11<\/td>\n<td width=\"66\">610 \u00b10.5<\/td>\n<td width=\"66\">610 \u00b10.5<\/td>\n<td width=\"51\">\u2126<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">&nbsp;<\/td>\n<td width=\"215\">For E<sub>max<\/sub> = 60 t<\/td>\n<td width=\"38\">R<sub>O<\/sub><\/td>\n<td width=\"70\">510 \u00b11<\/td>\n<td width=\"66\">510 \u00b10.5<\/td>\n<td width=\"66\">510 \u00b10.5<\/td>\n<td width=\"51\">\u2126<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">&nbsp;<\/td>\n<td width=\"215\">For E<sub>max<\/sub> = 75 t<\/td>\n<td width=\"38\">R<sub>O<\/sub><\/td>\n<td width=\"70\">410 \u00b11<\/td>\n<td width=\"66\">410 \u00b10.5<\/td>\n<td width=\"66\">410 \u00b10.5<\/td>\n<td width=\"51\">\u2126<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Insulation impedance<\/td>\n<td width=\"215\">Between measuring circuit and housing at 100 V<sub>DC<\/sub><\/td>\n<td width=\"38\">RIS<\/td>\n<td colspan=\"3\" width=\"202\">&gt;5,000 \u00d7 106<\/td>\n<td width=\"51\">\u2126<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Insulation voltage<\/td>\n<td width=\"215\">Between circuit and housing (Inteco\u00ae only)<\/td>\n<td width=\"38\">&nbsp;<\/td>\n<td colspan=\"3\" width=\"202\">500<\/td>\n<td width=\"51\">V<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Recommended supply voltage<\/td>\n<td width=\"215\">To hold the specified performance<\/td>\n<td width=\"38\">B<sub>u<\/sub><\/td>\n<td colspan=\"3\" width=\"202\">4&#8230;24<\/td>\n<td width=\"51\">VDC<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Max. supply voltage<\/td>\n<td width=\"215\">Permissible for continuous operation without dam- age<\/td>\n<td width=\"38\">Umax<\/td>\n<td colspan=\"3\" width=\"202\">32 (Ex versions: 25)<\/td>\n<td width=\"51\">VDC<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Nominal ambient temp. range<\/td>\n<td width=\"215\">To hold the specified performance<\/td>\n<td width=\"38\">B<sub>T<\/sub><\/td>\n<td width=\"70\">-10 \u2026 +40<\/td>\n<td width=\"66\">-10 \u2026 +40<\/td>\n<td width=\"66\">-10 \u2026 +40<\/td>\n<td width=\"51\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Usable temperature range<\/td>\n<td width=\"215\">Permissible for continuous operation without dam- age<\/td>\n<td width=\"38\">BTu<\/td>\n<td width=\"70\">-40 \u2026 +95<\/td>\n<td width=\"66\">-40 \u2026 +95<\/td>\n<td width=\"66\">-40 \u2026 +95<\/td>\n<td width=\"51\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Storage temperature range<\/td>\n<td width=\"215\">Without electrical and mechanical stress<\/td>\n<td width=\"38\">BTi<\/td>\n<td width=\"70\">-40 \u2026 +95<\/td>\n<td width=\"66\">-40 \u2026 +95<\/td>\n<td width=\"66\">-40 \u2026 +95<\/td>\n<td width=\"51\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Material (load cell housing)<\/td>\n<td colspan=\"6\" width=\"506\">Stainless steel 1.4301 acc. DIN EN 10088-3 (conforms to 304 AISI)<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Permissible eccentricity<\/td>\n<td width=\"215\">Permissible displacement from nominal load line<\/td>\n<td width=\"38\">Sex<\/td>\n<td colspan=\"3\" width=\"202\">For 500 kg \u2026 10 t: 10<\/p>\n<p>For 20 t \u2026 75 t:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 5<\/td>\n<td width=\"51\">mm<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Vibration resistance<\/td>\n<td width=\"215\">Resistance against oscillations (IEC 68-2-6 Fc)<\/td>\n<td width=\"38\">&nbsp;<\/td>\n<td colspan=\"4\" width=\"253\">20 g, 100 h, 10 \u2026 150 Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>1) The data for non-linearity (d<sub>Lin<\/sub>), hysteresis (d<sub>hy<\/sub>) and temperature effect on C (TK<sub>C<\/sub>) are typical values. For OIML R60 or NTEP approved load cells, the sum of these values is within the permissible cumulative error limits.<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"136\">Parameter<\/td>\n<td width=\"215\">Description<\/td>\n<td width=\"38\">Abbr.<\/td>\n<td width=\"70\">PR 6203 D1\/N<\/td>\n<td width=\"66\">PR 6203 C3<\/td>\n<td width=\"66\">PR 6203 C6<\/td>\n<td width=\"51\">Unit<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Barometric pressure influence<\/td>\n<td width=\"215\">Influence of barometric pressure on output<\/td>\n<td width=\"38\">PKSmin<\/td>\n<td colspan=\"3\" width=\"202\">500 kg \u2026 3 t: 200<\/p>\n<p>5 t \u2026 10 t:\u00a0\u00a0\u00a0\u00a0\u00a0 330<\/p>\n<p>20 t \u2026 75 t:\u00a0 420<\/td>\n<td width=\"51\">g\/kPa<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Nominal deflection<\/td>\n<td width=\"215\">Max. elastic deformation under maximum capacity<\/td>\n<td width=\"38\">Snom<\/td>\n<td colspan=\"3\" width=\"202\">\u22645 t: \u22640.3\/\u226420 t: \u22640.5\/\u226450 t: \u22640.8\/ 60 t \u2026 75 t: \u22641.2<\/td>\n<td width=\"51\">mm<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Protection class<\/td>\n<td colspan=\"6\" width=\"506\">according to IEC 529<\/p>\n<p>\u2013 Inteco: IP66 \/ IP68* \/ IP69<\/p>\n<p>\u2013 Connexx\u00ae: IP66 \/ IP 68**<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Cable<\/td>\n<td colspan=\"6\" width=\"506\">Length: E<sub>max<\/sub> \u226410 t: 5 m, E<sub>max<\/sub> &gt;10 t: 12 m Diameter: 5 mm<\/p>\n<p>Cross section: 4 \u00d7 0.35 mm2<\/p>\n<p>Material cable sheath: TPE<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Bending radius<\/td>\n<td colspan=\"6\" width=\"506\">\u226525 mm in case of fixed installation<\/p>\n<p>\u226575 mm in case of flexible installation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"5\" width=\"643\">Connexx<sup>\u00ae<\/sup><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Nominal ambient temp. range<\/td>\n<td width=\"215\">To hold the specified performance<\/td>\n<td width=\"38\">B<sub>T<\/sub><\/td>\n<td width=\"202\">-10 \u2026 +40<\/td>\n<td width=\"51\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Usable temperature range<\/td>\n<td width=\"215\">Permissible for continuous operation without dam- age<\/td>\n<td width=\"38\">BTu<\/td>\n<td width=\"202\">-30 \u2026 +60<\/td>\n<td width=\"51\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Storage temperature range<\/td>\n<td width=\"215\">Without electrical and mechanical stress<\/td>\n<td width=\"38\">BTi<\/td>\n<td width=\"202\">-30 \u2026 +70<\/td>\n<td width=\"51\">\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* The load cell can be submerged in water at a depth of 1.5 m for 10,000 hours.<br \/>\n** The module can be submerged in water at a depth of 1.5 m for 100 hours.<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"10\" width=\"642\">Accuracy classes and minimum verification interval, v<sub>min<\/sub><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"149\">&nbsp;<\/td>\n<td colspan=\"3\" width=\"164\">OIML<\/td>\n<td colspan=\"3\" width=\"164\">NTEP Class III Multiple<\/td>\n<td colspan=\"3\" width=\"164\">NTEP Class IIIL Multiple<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">D1\/D1E<\/td>\n<td width=\"55\">C3\/C3E<\/td>\n<td width=\"55\">C6\/C6E<\/td>\n<td width=\"55\">D1\/D1E<\/td>\n<td width=\"55\">C3\/C3E<\/td>\n<td width=\"55\">C6\/C6E<\/td>\n<td width=\"55\">D1\/D1E<\/td>\n<td width=\"55\">C3\/C3E<\/td>\n<td width=\"55\">C6\/C6E<\/td>\n<\/tr>\n<tr>\n<td width=\"149\">Maximum number of verification intervals, n<sub>max<\/sub><\/td>\n<td width=\"55\">1,000<\/td>\n<td width=\"55\">3,000<\/td>\n<td width=\"55\">6,000<\/td>\n<td width=\"55\">1,000<\/td>\n<td width=\"55\">5,000<\/td>\n<td width=\"55\">10,000<\/td>\n<td width=\"55\">2,000<\/td>\n<td width=\"55\">10,000<\/td>\n<td width=\"55\">10,000<\/td>\n<\/tr>\n<tr>\n<td width=\"149\">500 kg<\/td>\n<td width=\"55\">0.2 kg<\/td>\n<td width=\"55\">n.a.<\/td>\n<td width=\"55\">n.a.<\/td>\n<td width=\"55\">0.2 kg<\/td>\n<td width=\"55\">n.a.<\/td>\n<td width=\"55\">n.a.<\/td>\n<td width=\"55\">n.a.<\/td>\n<td width=\"55\">n.a.<\/td>\n<td width=\"55\">n.a.<\/td>\n<\/tr>\n<tr>\n<td width=\"149\">1 t<\/td>\n<td width=\"55\">0.2 kg<\/td>\n<td width=\"55\">n.a.<\/td>\n<td width=\"55\">n.a.<\/td>\n<td width=\"55\">0.2 kg<\/td>\n<td width=\"55\">n.a.<\/td>\n<td width=\"55\">n.a.<\/td>\n<td width=\"55\">n.a.<\/td>\n<td width=\"55\">n.a.<\/td>\n<td width=\"55\">n.a.<\/td>\n<\/tr>\n<tr>\n<td width=\"149\">2 t<\/td>\n<td width=\"55\">0.4 kg<\/td>\n<td width=\"55\">0.2 kg<\/td>\n<td width=\"55\">n.a.<\/td>\n<td width=\"55\">0.4 kg<\/td>\n<td width=\"55\">0.2 kg<\/td>\n<td width=\"55\">n.a.<\/td>\n<td width=\"55\">0.2 kg<\/td>\n<td width=\"55\">0.2 kg<\/td>\n<td width=\"55\">n.a.<\/td>\n<\/tr>\n<tr>\n<td width=\"149\">3 t<\/td>\n<td width=\"55\">0.6 kg<\/td>\n<td width=\"55\">0.22 kg<\/td>\n<td width=\"55\">0.22 kg<\/td>\n<td width=\"55\">0.6 kg<\/td>\n<td width=\"55\">0.22 kg<\/td>\n<td width=\"55\">0.22 kg<\/td>\n<td width=\"55\">0.2 kg<\/td>\n<td width=\"55\">0.2 kg<\/td>\n<td width=\"55\">0.2 kg<\/td>\n<\/tr>\n<tr>\n<td width=\"149\">5 t<\/td>\n<td width=\"55\">1 kg<\/td>\n<td width=\"55\">0.36 kg<\/td>\n<td width=\"55\">0.36 kg<\/td>\n<td width=\"55\">1 kg<\/td>\n<td width=\"55\">0.36 kg<\/td>\n<td width=\"55\">0.36 kg<\/td>\n<td width=\"55\">0.34 kg<\/td>\n<td width=\"55\">0.2 kg<\/td>\n<td width=\"55\">0.2 kg<\/td>\n<\/tr>\n<tr>\n<td width=\"149\">10 t<\/td>\n<td width=\"55\">2 kg<\/td>\n<td width=\"55\">0.72 kg<\/td>\n<td width=\"55\">0.72 kg<\/td>\n<td width=\"55\">2 kg<\/td>\n<td width=\"55\">0.72 kg<\/td>\n<td width=\"55\">0.72 kg<\/td>\n<td width=\"55\">0.67 kg<\/td>\n<td width=\"55\">0.24 kg<\/td>\n<td width=\"55\">0.24 kg<\/td>\n<\/tr>\n<tr>\n<td width=\"149\">20 t<\/td>\n<td width=\"55\">4 kg<\/td>\n<td width=\"55\">1.43 kg<\/td>\n<td width=\"55\">1 kg<\/td>\n<td width=\"55\">4 kg<\/td>\n<td width=\"55\">1.43 kg<\/td>\n<td width=\"55\">1 kg<\/td>\n<td width=\"55\">1.34 kg<\/td>\n<td width=\"55\">0.48 kg<\/td>\n<td width=\"55\">0.34 kg<\/td>\n<\/tr>\n<tr>\n<td width=\"149\">30 t<\/td>\n<td width=\"55\">6 kg<\/td>\n<td width=\"55\">2.15 kg<\/td>\n<td width=\"55\">1.5 kg<\/td>\n<td width=\"55\">6 kg<\/td>\n<td width=\"55\">2.15 kg<\/td>\n<td width=\"55\">1.5 kg<\/td>\n<td width=\"55\">2 kg<\/td>\n<td width=\"55\">0.72 kg<\/td>\n<td width=\"55\">0.5 kg<\/td>\n<\/tr>\n<tr>\n<td width=\"149\">50 t<\/td>\n<td width=\"55\">10 kg<\/td>\n<td width=\"55\">3.58 kg<\/td>\n<td width=\"55\">2.5 kg<\/td>\n<td width=\"55\">10 kg<\/td>\n<td width=\"55\">3.58 kg<\/td>\n<td width=\"55\">2.5 kg<\/td>\n<td width=\"55\">3.34 kg<\/td>\n<td width=\"55\">1.2 kg<\/td>\n<td width=\"55\">0.84 kg<\/td>\n<\/tr>\n<tr>\n<td width=\"149\">60 t<\/td>\n<td width=\"55\">12 kg<\/td>\n<td width=\"55\">4.29 kg<\/td>\n<td width=\"55\">3 kg<\/td>\n<td width=\"55\">12 kg<\/td>\n<td width=\"55\">4.29 kg<\/td>\n<td width=\"55\">3 kg<\/td>\n<td width=\"55\">4 kg<\/td>\n<td width=\"55\">1.43 kg<\/td>\n<td width=\"55\">1 kg<\/td>\n<\/tr>\n<tr>\n<td width=\"149\">75 t<\/td>\n<td width=\"55\">15 kg<\/td>\n<td width=\"55\">5.36 kg<\/td>\n<td width=\"55\">3.75 kg<\/td>\n<td width=\"55\">15 kg<\/td>\n<td width=\"55\">5.36 kg<\/td>\n<td width=\"55\">3.75 kg<\/td>\n<td width=\"55\">5 kg<\/td>\n<td width=\"55\">1.79 kg<\/td>\n<td width=\"55\">1.25 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Time savings with matched output<\/strong><\/p>\n<p>The output impedance (R<sub>0<\/sub>) and parameter (C<sub>n<\/sub>) of the load cells are within a tight tolerance range(= matched output) both individually and together. A preliminary adjustment of the entire measure- ment chain can therefore be performed without reference weight. Thanks to the matched output technology, a damaged load cell can be replaced without the need for recalibration.<\/p>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li>High flexibility for a number of applications<\/li>\n<li>Maximum measuring accuracy and repeatability error<\/li>\n<li>Simple and fault-free installation using sophisticated mounting kits<\/li>\n<li>Robust design for long-lasting use<\/li>\n<\/ul>\n","protected":false},"featured_media":287175,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5449],"product_cat":[3387],"product_tag":[4646],"class_list":{"0":"post-287176","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-minebea-intec","7":"product_cat-tension-compression-load-cell","8":"product_tag-compression-load-cell-en","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Minebea intec \/ Compression load cell Inteco\u00ae, converter Connexx\u00ae, mounting kits PR 600x, PR 614x - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"High flexibility for a number of applications  Maximum measuring accuracy and repeatability error  Simple and fault-free installation using sophisticated mounting kits  Robust design for long-lasting use\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/products\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Minebea intec \/ Compression load cell Inteco\u00ae, converter Connexx\u00ae, mounting kits PR 600x, PR 614x\" \/>\n<meta property=\"og:description\" content=\"High flexibility for a number of applications  Maximum measuring accuracy and repeatability error  Simple and fault-free installation using sophisticated mounting kits  Robust design for long-lasting use\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/products\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/csm_inteco_pr_6203_with-cable_front_view_5e8c6e5135.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"550\" \/>\n\t<meta property=\"og:image:height\" content=\"367\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\\\/\",\"name\":\"Minebea intec \\\/ Compression load cell Inteco\u00ae, converter Connexx\u00ae, mounting kits PR 600x, PR 614x - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/csm_inteco_pr_6203_with-cable_front_view_5e8c6e5135.webp\",\"datePublished\":\"2026-01-22T01:44:36+00:00\",\"description\":\"High flexibility for a number of applications Maximum measuring accuracy and repeatability error Simple and fault-free installation using sophisticated mounting kits Robust design for long-lasting use\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/csm_inteco_pr_6203_with-cable_front_view_5e8c6e5135.webp\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/csm_inteco_pr_6203_with-cable_front_view_5e8c6e5135.webp\",\"width\":550,\"height\":367},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Minebea intec \\\/ Compression load cell Inteco\u00ae, converter Connexx\u00ae, mounting kits PR 600x, PR 614x\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/products\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Minebea intec \/ Compression load cell Inteco\u00ae, converter Connexx\u00ae, mounting kits PR 600x, PR 614x - CAS Scale Korea Co., Ltd.","description":"High flexibility for a number of applications  Maximum measuring accuracy and repeatability error  Simple and fault-free installation using sophisticated mounting kits  Robust design for long-lasting use","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/products\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\/","og_locale":"en_US","og_type":"article","og_title":"Minebea intec \/ Compression load cell Inteco\u00ae, converter Connexx\u00ae, mounting kits PR 600x, PR 614x","og_description":"High flexibility for a number of applications  Maximum measuring accuracy and repeatability error  Simple and fault-free installation using sophisticated mounting kits  Robust design for long-lasting use","og_url":"https:\/\/casscale.net\/en\/products\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\/","og_site_name":"CAS Scale Korea Co., Ltd.","og_image":[{"width":550,"height":367,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/csm_inteco_pr_6203_with-cable_front_view_5e8c6e5135.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/products\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\/","url":"https:\/\/casscale.net\/en\/products\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\/","name":"Minebea intec \/ Compression load cell Inteco\u00ae, converter Connexx\u00ae, mounting kits PR 600x, PR 614x - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/products\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/products\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/csm_inteco_pr_6203_with-cable_front_view_5e8c6e5135.webp","datePublished":"2026-01-22T01:44:36+00:00","description":"High flexibility for a number of applications Maximum measuring accuracy and repeatability error Simple and fault-free installation using sophisticated mounting kits Robust design for long-lasting use","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/products\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/products\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/products\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/csm_inteco_pr_6203_with-cable_front_view_5e8c6e5135.webp","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/csm_inteco_pr_6203_with-cable_front_view_5e8c6e5135.webp","width":550,"height":367},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/products\/minebea-intec-compression-load-cell-inteco-converter-connexx-mounting-kits-pr-600x-pr-614x\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"Minebea intec \/ Compression load cell Inteco\u00ae, converter Connexx\u00ae, mounting kits PR 600x, PR 614x"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/products\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/287176","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=287176"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/287175"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=287176"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=287176"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=287176"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=287176"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}