{"id":287233,"date":"2026-01-22T11:46:33","date_gmt":"2026-01-22T02:46:33","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\/"},"modified":"2026-01-22T11:46:33","modified_gmt":"2026-01-22T02:46:33","slug":"minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\/","title":{"rendered":"Minebea intec \/ Compact compression load cell PR 6211,  Converter Connexx\u00ae  and mounting kits PR 6011\/PR 6012"},"content":{"rendered":"<h2>Compact compression load cell PR 6211, Converter Connexx\u00ae and mounting kits PR 6011\/PR 6012<\/h2>\n<p><strong>Technical specifications<\/strong><\/p>\n<p>Compact compression load cell PR 6211<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"178\">Parameter<\/td>\n<td width=\"299\">Description<\/td>\n<td width=\"38\">Abbr.<\/td>\n<td width=\"76\">D1 30 to 300 kg<\/td>\n<td width=\"53\">Unit<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Accuracy class<\/td>\n<td width=\"299\"><\/td>\n<td width=\"38\"><\/td>\n<td width=\"76\">0.05<\/td>\n<td width=\"53\">%Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Minimum dead load<\/td>\n<td width=\"299\">Lowest limit of specified measuring range<\/td>\n<td width=\"38\">Emin<\/td>\n<td width=\"76\">0<\/td>\n<td width=\"53\">%Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Maximum capacity<\/td>\n<td width=\"299\">Highest limit of specified measuring range<\/td>\n<td width=\"38\">Emax<\/td>\n<td width=\"76\">See Ordering information table<\/td>\n<td width=\"53\">kg<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Safe load limit<\/td>\n<td width=\"299\">Maximum load without irreversible damage<\/td>\n<td width=\"38\">Elim<\/td>\n<td width=\"76\">500<\/td>\n<td width=\"53\">kg<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Destructive load<\/td>\n<td width=\"299\">Danger of mechanical destruction<\/td>\n<td width=\"38\">E<sub>d<\/sub><\/td>\n<td width=\"76\">1,000<\/td>\n<td width=\"53\">kg<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Minimum LC verification<\/td>\n<td width=\"299\">Minimum load cell verification interval, v<sub>min<\/sub> = E<sub>max<\/sub>\/Y<\/p>\n<p>\u2013 E<sub>max<\/sub> = 50 to 300 kg<\/p>\n<p>\u2013 E<sub>max<\/sub> = 30 kg<\/td>\n<td width=\"38\">&nbsp;<\/p>\n<p>Y Y<\/td>\n<td width=\"76\">&nbsp;<\/p>\n<p>3,333<\/p>\n<p>2,500<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Rated output<\/td>\n<td width=\"299\">Relative output at maximum capacity<\/td>\n<td width=\"38\">C<sub>n<\/sub><\/td>\n<td width=\"76\">2<\/td>\n<td width=\"53\">mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Tolerance on rated output<\/td>\n<td width=\"299\">Permissible deviation from rated output<\/td>\n<td width=\"38\">d<sub>c<\/sub><\/td>\n<td width=\"76\">&lt;0.25<\/td>\n<td width=\"53\">%C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Zero output signal<\/td>\n<td width=\"299\">Load cell output signal under unloaded condition<\/td>\n<td width=\"38\">Smin<\/td>\n<td width=\"76\">0 to 2<\/td>\n<td width=\"53\">%C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Reproducibility<\/td>\n<td width=\"299\">Max. change in load cell output for repeated loading<\/td>\n<td width=\"38\">eR<\/td>\n<td width=\"76\">&lt;0.01<\/td>\n<td width=\"53\">%C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Creep<\/td>\n<td width=\"299\">Max. change of output signal under E<sub>max<\/sub> during 30 min.<\/td>\n<td width=\"38\">dcr<\/td>\n<td width=\"76\">&lt;0.03<\/td>\n<td width=\"53\">%C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Non-linearity<sup>1)<\/sup><\/td>\n<td width=\"299\">Max. deviation from best straight line through zero<\/td>\n<td width=\"38\">dLin<\/td>\n<td width=\"76\">&lt;0.05<\/td>\n<td width=\"53\">%C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Hysteresis<sup>1)<\/sup><\/td>\n<td width=\"299\">Max. difference in LC output between loading and unloading<\/td>\n<td width=\"38\">dhy<\/td>\n<td width=\"76\">&lt;0.05<\/td>\n<td width=\"53\">%C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Temperature effect on S<sub>min<\/sub><\/td>\n<td width=\"299\">Max. change of S<sub>min<\/sub> in B<sub>T<\/sub><\/td>\n<td width=\"38\">TKS<sub>min<\/sub><\/td>\n<td width=\"76\">&lt;0.042<\/td>\n<td width=\"53\">%C<sub>n<\/sub>\/10 K<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Temperature effect on C<sup>1)<\/sup><\/td>\n<td width=\"299\">Max. change of C in B<sub>T<\/sub><\/td>\n<td width=\"38\">TK<sub>c<\/sub><\/td>\n<td width=\"76\">&lt;0.03<\/td>\n<td width=\"53\">%C<sub>n<\/sub>\/10 K<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Input impedance<\/td>\n<td width=\"299\">Between supply terminals<\/td>\n<td width=\"38\">RLC<\/td>\n<td width=\"76\">1,300 \u00b1 12<\/td>\n<td width=\"53\">\u2126<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Output impedance<\/td>\n<td width=\"299\">Between measuring terminals<\/td>\n<td width=\"38\">R<sub>O<\/sub><\/td>\n<td width=\"76\">1,200 \u00b1 2<\/td>\n<td width=\"53\">\u2126<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Insulation impedance<\/td>\n<td width=\"299\">Between measuring circuit and housing at 100 V<sub>DC<\/sub><\/td>\n<td width=\"38\">RIS<\/td>\n<td width=\"76\">&gt;5,000&#215;10<sup>6<\/sup><\/td>\n<td width=\"53\">\u2126<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Recommended supply voltage<\/td>\n<td width=\"299\">To hold the specified performance<\/td>\n<td width=\"38\">B<sub>u<\/sub><\/td>\n<td width=\"76\">4 to 24<\/td>\n<td width=\"53\">V<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Max. supply voltage<\/td>\n<td width=\"299\">Permissible for continuous operation without damage<\/td>\n<td width=\"38\">Umax<\/td>\n<td width=\"76\">32<\/td>\n<td width=\"53\">V<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Nominal ambient temp. range<\/td>\n<td width=\"299\">To hold the specified performance<\/td>\n<td width=\"38\">B<sub>T<\/sub><\/td>\n<td width=\"76\">-10 to +85<\/td>\n<td width=\"53\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Usable ambient temp. range<\/td>\n<td width=\"299\">Permissible for continuous operation without damage<\/td>\n<td width=\"38\">BTU<\/td>\n<td width=\"76\">-30 to +95<\/td>\n<td width=\"53\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Storage temperature range<\/td>\n<td width=\"299\">Without electrical and mechanical stress<\/td>\n<td width=\"38\">BTI<\/td>\n<td width=\"76\">-40 to +95<\/td>\n<td width=\"53\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Permissible eccentricity<\/td>\n<td width=\"299\">Permissible displacement from nominal load line<\/td>\n<td width=\"38\">Sex<\/td>\n<td width=\"76\">3<\/td>\n<td width=\"53\">mm<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Vibration resistance<\/td>\n<td colspan=\"2\" width=\"336\">Resistance against oscillations (IEC 68-2-6 Fc)<\/td>\n<td width=\"76\">20 g,100 h,<\/p>\n<p>10 to 150Hz<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Barometric pressure influence<\/td>\n<td width=\"299\">Influence of barometric pressure on output<\/td>\n<td width=\"38\">PKSmin<\/td>\n<td width=\"76\">\u226412<\/td>\n<td width=\"53\">g\/kPa<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Nominal deflection<\/td>\n<td width=\"299\">Max. elastic deformation under nominal load<\/td>\n<td width=\"38\">Snom<\/td>\n<td width=\"76\">&lt;0.1<\/td>\n<td width=\"53\">mm<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Material (sensor)<\/td>\n<td colspan=\"4\" width=\"465\">Stainless steel 1.4542<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Protection class<\/td>\n<td colspan=\"4\" width=\"465\">IP68<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Cable<\/td>\n<td colspan=\"4\" width=\"465\">nach IEC 529<\/p>\n<p>\u2013 PR 6211: IP68*\/IP69<\/p>\n<p>\u2013 Connexx<sup>\u00ae<\/sup>: IP65 \/ IP 68** Length: 3 m<\/p>\n<p>Diameter: 3 mm<\/p>\n<p>Cross section: 4 \u00d7 0.087 mm<sup>2<\/sup> Material cable sheath: TPE<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Bending radius<\/td>\n<td colspan=\"4\" width=\"465\">\u2265 15.5 mm at fixed installation<\/p>\n<p>\u2265 46.5 mm at flexible installation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"5\" width=\"642\">Connexx<sup>\u00ae<\/sup><\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Nominal ambient temp. range<\/td>\n<td width=\"299\">To hold the specified performance<\/td>\n<td width=\"38\">B<sub>T<\/sub><\/td>\n<td width=\"76\">-10 \u2026 +40<\/td>\n<td width=\"53\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Usable temperature range<\/td>\n<td width=\"299\">Permissible for continuous operation without damage<\/td>\n<td width=\"38\">BTu<\/td>\n<td width=\"76\">-30 \u2026 +60<\/td>\n<td width=\"53\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">Storage temperature range<\/td>\n<td width=\"299\">Without electrical and mechanical stress<\/td>\n<td width=\"38\">BTi<\/td>\n<td width=\"76\">-30 \u2026 +70<\/td>\n<td width=\"53\">\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* The load cell can be submerged in water at a depth of 1.5 m for 10,000 hours.<br \/>\n** The module can be submerged in water at a depth of 1.5 m for 100 hours.<br \/>\n<sup>1)<\/sup> The data for Non-linearity, hysteresis and TKC are typical values. For OIML R60 or NTEP approved load cells the sum of these values is within the permissible cumulative error limits<\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"10\" width=\"643\">Mounting kits PR 6011 and PR 6012<\/td>\n<\/tr>\n<tr>\n<td width=\"42\">Maximum capacity of load cell<\/p>\n<p>PR 6211<\/td>\n<td width=\"79\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Mounting kit\/ accessories<\/td>\n<td width=\"98\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Material<\/td>\n<td width=\"133\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Description\/comments<\/td>\n<td width=\"48\">&nbsp;<\/p>\n<p>Mounting screws<\/td>\n<td width=\"48\">&nbsp;<\/p>\n<p>Installation height (mm)<\/td>\n<td width=\"48\">Max. permissible horizontal force (kN)<\/td>\n<td width=\"48\">&nbsp;<\/p>\n<p>Max. permissible lift-off force [kN]<\/td>\n<td width=\"48\">&nbsp;<\/p>\n<p>Max. permissible eccentricity<\/td>\n<td width=\"48\">Max. permissible vertical load with- out load cell<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" width=\"42\">&nbsp;<\/p>\n<p>30 kg \u2013 300 kg<\/td>\n<td width=\"79\">PR 6011\/00S<\/td>\n<td rowspan=\"2\" width=\"98\">Stainless steel 1.4301 (AISI 304)<\/td>\n<td width=\"133\">Plate mounting kit<\/td>\n<td width=\"48\">M6<\/td>\n<td rowspan=\"2\" width=\"48\">&nbsp;<\/p>\n<p>32.3<\/td>\n<td width=\"48\">\/<\/td>\n<td width=\"48\">\/<\/td>\n<td width=\"48\">\/<\/td>\n<td width=\"48\">\/<\/td>\n<\/tr>\n<tr>\n<td width=\"79\">PR 6011\/20S<\/td>\n<td width=\"133\">MiniFLEXLOCK<\/td>\n<td width=\"48\">M6<\/td>\n<td width=\"48\">0.45<\/td>\n<td width=\"48\">\/<\/td>\n<td width=\"48\">\/<\/td>\n<td width=\"48\">\/<\/td>\n<\/tr>\n<tr>\n<td width=\"79\">PR 6011\/03<\/td>\n<td width=\"98\">Natural rubber<\/td>\n<td width=\"133\">Elastomeric bearing<\/td>\n<td width=\"48\">\/<\/td>\n<td width=\"48\">37<\/td>\n<td width=\"48\">\/<\/td>\n<td width=\"48\">\/<\/td>\n<td width=\"48\">\/<\/td>\n<td width=\"48\">\/<\/td>\n<\/tr>\n<tr>\n<td width=\"79\">PR 6012\/00S<\/td>\n<td rowspan=\"2\" width=\"98\">Stainless steel 1.4301 (AISI 304)<\/td>\n<td width=\"133\">Plate mounting kit<\/td>\n<td width=\"48\">M6<\/td>\n<td rowspan=\"2\" width=\"48\">&nbsp;<\/p>\n<p>42.2<\/td>\n<td width=\"48\">\/<\/td>\n<td width=\"48\">4<\/td>\n<td width=\"48\">\/<\/td>\n<td width=\"48\">300 kg<\/td>\n<\/tr>\n<tr>\n<td width=\"79\">PR 6012\/20S<\/td>\n<td width=\"133\">MiniFLEXLOCK<\/td>\n<td width=\"48\">M6<\/td>\n<td width=\"48\">0.45<\/td>\n<td width=\"48\">4<\/td>\n<td width=\"48\">\/<\/td>\n<td width=\"48\">300 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-287217 alignleft\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Mounting-kits-PR-6011.png\" alt=\"\" width=\"572\" height=\"415\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Mounting-kits-PR-6011.png 1039w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Mounting-kits-PR-6011-552x400.png 552w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Mounting-kits-PR-6011-768x557.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Mounting-kits-PR-6011-600x435.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Mounting-kits-PR-6011-64x46.png 64w\" sizes=\"(max-width: 572px) 100vw, 572px\" \/><\/p>\n<p>Fitted with the converter Connexx<sup>\u00ae<\/sup>, the load cell PR 6211 offers a whole host of possibilities:<\/p>\n<ul>\n<li>\u00a0The digital version guarantees fast signalling times for reliable dosing processes.<\/li>\n<li>\u00a0Thanks to the use of field bus communication, the cable junction box is no longer needed.<\/li>\n<li>\u00a0The standard interface CANopen ensures straightforward installation and calibration.<\/li>\n<li>\u00a0CANopen allows for extra-long communication paths of up to 200 m.<\/li>\n<li>\u00a0Weight values can also be generated individ- ually \u2013 per load cell \u2013 meaning that defective load cells can be identified more easily.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>Technical diagrams<\/h4>\n<p>Load cell PR 6211 (30 kg to 300 kg)<\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-287219\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Load-cell-PR-6211-.png\" alt=\"\" width=\"1046\" height=\"561\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Load-cell-PR-6211-.png 1046w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Load-cell-PR-6211--746x400.png 746w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Load-cell-PR-6211--768x412.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Load-cell-PR-6211--600x322.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Load-cell-PR-6211--64x34.png 64w\" sizes=\"(max-width: 1046px) 100vw, 1046px\" \/><\/p>\n<p>Converter Connexx<sup>\u00ae<\/sup><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-287221\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Converter-Connexx.png\" alt=\"\" width=\"1316\" height=\"647\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Converter-Connexx.png 1316w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Converter-Connexx-800x393.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Converter-Connexx-768x378.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Converter-Connexx-600x295.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Converter-Connexx-64x31.png 64w\" sizes=\"(max-width: 1316px) 100vw, 1316px\" \/><\/p>\n<p>Plate mounting kit and MiniFLEXLOCK for PR 6211 (30 kg to 300 kg)<\/p>\n<table>\n<tbody>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-287223\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6011-00S.png\" alt=\"\" width=\"563\" height=\"576\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6011-00S.png 563w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6011-00S-391x400.png 391w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6011-00S-64x65.png 64w\" sizes=\"(max-width: 563px) 100vw, 563px\" \/><br \/>\nPR 6011\/00S<\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-287225\" style=\"font-family: inherit;\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6011-20.png\" alt=\"\" width=\"483\" height=\"572\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6011-20.png 483w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6011-20-338x400.png 338w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6011-20-64x76.png 64w\" sizes=\"(max-width: 483px) 100vw, 483px\" \/><br \/>\nPR 6011\/20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Plate mounting kit and MiniFLEXLOCK for PR 6211 (30 kg to 300 kg)<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\">Plate mounting kit and MiniFLEXLOCK for PR 6211 (30 kg to 300 kg)<\/td>\n<td>Elastomeric bearing for PR 6211 (30 kg to 300 kg)<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-287227\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-00S.png\" alt=\"\" width=\"462\" height=\"577\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-00S.png 462w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-00S-320x400.png 320w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-00S-64x80.png 64w\" sizes=\"(max-width: 462px) 100vw, 462px\" \/><\/p>\n<p>PR 6012\/00S<\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-287229\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-20S.png\" alt=\"\" width=\"456\" height=\"580\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-20S.png 456w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-20S-314x400.png 314w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-20S-64x81.png 64w\" sizes=\"(max-width: 456px) 100vw, 456px\" \/><\/p>\n<p>PR 6012\/20S<\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-287231\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/6011-03N.png\" alt=\"\" width=\"453\" height=\"569\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/6011-03N.png 453w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/6011-03N-318x400.png 318w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/6011-03N-64x80.png 64w\" sizes=\"(max-width: 453px) 100vw, 453px\" \/><\/p>\n<p>6011\/03N<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Ex approval<\/h4>\n<p>Scope of validity: PR 6211\/\u2026 D1 (30 kg to 300 kg)<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"4\" width=\"643\">Ex certificates<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">Zone<\/td>\n<td width=\"227\">Labelling<\/td>\n<td width=\"170\">Certificate number<\/td>\n<td width=\"170\">For<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">2<\/td>\n<td width=\"227\">II 3G Ex nA IIC T6 Gc<\/td>\n<td width=\"170\">Manufacturer\u2019s declaration<\/td>\n<td width=\"170\">all PR 6211<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">22<\/td>\n<td width=\"227\">II 3D Ex tc IIIC T85 \u00b0C Dc<\/td>\n<td width=\"170\">Manufacturer\u2019s declaration<\/td>\n<td width=\"170\">all PR 6211<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">FMus<\/p>\n<p>clases I, II, III div. 1 + 2<\/td>\n<td width=\"227\">IS CL I, II, III, DIV 1, GP A,B,C,D,E,F,G Entity \u2013 4012 101 5688<\/p>\n<p>NI CL I, II, III, DIV 2, GP A,B,C,D,E,F,G \u2013 4012 101 5688; NIFW<\/p>\n<p>T4A Ta= -30 \u00b0C a 70\u00b0 C; T5 Ta= -30 \u00b0C a 55 \u00b0C<\/td>\n<td width=\"170\">FM17US0276<\/td>\n<td width=\"170\">all PR 6211<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">FMca<\/p>\n<p>clases I, II, III div. 1 + 2<\/td>\n<td width=\"227\">IS CL I, II, III, DIV 1, GP A,B,C,D,E,F,G Entity \u2013 4012 101 5688<\/p>\n<p>NI CL I, II, III, DIV 2, GP A,B,C,D, E, F, G \u2013 4012 101 5688; NIFW<\/p>\n<p>T4A Ta= -30 \u00b0C a 70\u00b0 C; T5 Ta= -30 \u00b0C a 55 \u00b0C<\/td>\n<td width=\"170\">FM17CA0138<\/td>\n<td width=\"170\">all PR 6211<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h1>Ordering information<\/h1>\n<p>The accuracy class of the compact compression load cell PR 6211 is classified and checked in accordance with OIML R60.<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"3\" width=\"642\">Compact compression load cell PR 6211, accuracy class D1=0.05%<\/td>\n<\/tr>\n<tr>\n<td width=\"161\">Type<\/td>\n<td width=\"161\">Load stage<\/td>\n<td width=\"321\">Order number<\/td>\n<\/tr>\n<tr>\n<td width=\"161\">PR 6211\/31D1<\/td>\n<td width=\"161\">30 kg<\/td>\n<td width=\"321\">940526211311<\/td>\n<\/tr>\n<tr>\n<td width=\"161\">PR 6211\/51D1<\/td>\n<td width=\"161\">50 kg<\/td>\n<td width=\"321\">940526211511<\/td>\n<\/tr>\n<tr>\n<td width=\"161\">PR 6211\/12D1<\/td>\n<td width=\"161\">100 kg<\/td>\n<td width=\"321\">940526211121<\/td>\n<\/tr>\n<tr>\n<td width=\"161\">PR 6211\/22D1<\/td>\n<td width=\"161\">200 kg<\/td>\n<td width=\"321\">940526211221<\/td>\n<\/tr>\n<tr>\n<td width=\"161\">PR 6211\/32D1<\/td>\n<td width=\"161\">300 kg<\/td>\n<td width=\"321\">940526211321<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"3\" width=\"643\">Compact compression load cell PR 6211, Converter Connexx<sup>\u00ae<\/sup><\/td>\n<\/tr>\n<tr>\n<td width=\"189\">Type<\/td>\n<td width=\"302\">Description<\/td>\n<td width=\"151\">Order number<\/td>\n<\/tr>\n<tr>\n<td width=\"189\">PR 6211\/DIGITAL KIT<\/td>\n<td width=\"302\">The converter Connexx<sup>\u00ae<\/sup> can only be ordered with the above-mentioned load cells from the PR 6211 series. When ordering, both order numbers need to be given.<\/td>\n<td width=\"151\">940511100000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional information: The converters Connexx<sup>\u00ae<\/sup> can be used with the Indicator X3.<br \/>\nTo do this, the indicator X3 must be equipped with a CANopen interface card PR 5510\/05 (940535510051).<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"3\" width=\"643\">Compact compression load cell PR 6211, Converter Connexx<sup>\u00ae<\/sup> \u2013 application sets<\/td>\n<\/tr>\n<tr>\n<td width=\"189\">Type<\/td>\n<td width=\"302\">Description<\/td>\n<td width=\"151\">Order number<\/td>\n<\/tr>\n<tr>\n<td width=\"189\">PR 6154\/03<\/td>\n<td width=\"302\">Application set for 3 load cells.<\/p>\n<p>Includes: 2 \u00d7 PR 6155\/05, 1 \u00d7 PR 6152\/25, 1 \u00d7 PR 6153\/99<\/td>\n<td width=\"151\">940536154031<\/td>\n<\/tr>\n<tr>\n<td width=\"189\">PR 6154\/04<\/td>\n<td width=\"302\">Application set for 4 load cells.<\/p>\n<p>Includes: 3 \u00d7 PR 6155\/05, 1 \u00d7 PR 6152\/25, 1 \u00d7 PR 6153\/99<\/td>\n<td width=\"151\">940536154041<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"3\" width=\"643\">Compact compression load cell PR 6211, Converter Connexx<sup>\u00ae<\/sup> \u2013 load cell accessories<\/td>\n<\/tr>\n<tr>\n<td width=\"189\">Type<\/td>\n<td width=\"302\">Description<\/td>\n<td width=\"151\">Order number<\/td>\n<\/tr>\n<tr>\n<td width=\"189\">PR 6152\/10<\/td>\n<td width=\"302\">Connection cable between Connexx<sup>\u00ae<\/sup> and X3 (10 m)<\/td>\n<td width=\"151\">940536152101<\/td>\n<\/tr>\n<tr>\n<td width=\"189\">PR 6152\/25<\/td>\n<td width=\"302\">Connection cable between Connexx<sup>\u00ae<\/sup> and X3 (25 m)<\/td>\n<td width=\"151\">940536152251<\/td>\n<\/tr>\n<tr>\n<td width=\"189\">PR 6152\/40<\/td>\n<td width=\"302\">Connection cable between Connexx<sup>\u00ae<\/sup> and X3 (40 m)<\/td>\n<td width=\"151\">940536152401<\/td>\n<\/tr>\n<tr>\n<td width=\"189\">PR 6153\/98<\/td>\n<td width=\"302\">Divided cable gland<\/td>\n<td width=\"151\">940536153981<\/td>\n<\/tr>\n<tr>\n<td width=\"189\">PR 6153\/99<\/td>\n<td width=\"302\">Terminal resistor for Connexx<sup>\u00ae<\/sup>, M12<\/td>\n<td width=\"151\">940536153991<\/td>\n<\/tr>\n<tr>\n<td width=\"189\">PR 6155\/05<\/td>\n<td width=\"302\">Connection cable between Connexx<sup>\u00ae<\/sup> and Connexx<sup>\u00ae<\/sup> (5 m)<\/td>\n<td width=\"151\">940536155051<\/td>\n<\/tr>\n<tr>\n<td width=\"189\">PR 6155\/10<\/td>\n<td width=\"302\">Connection cable between Connexx<sup>\u00ae<\/sup> and Connexx<sup>\u00ae<\/sup> (10 m)<\/td>\n<td width=\"151\">940536155101<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"3\" width=\"642\">Mounting kits for PR 6211 (30 kg &#8211; 300 kg)<\/td>\n<\/tr>\n<tr>\n<td width=\"161\">Type<\/td>\n<td width=\"321\">Description<\/td>\n<td width=\"161\">Order number<\/td>\n<\/tr>\n<tr>\n<td width=\"161\">PR 6011\/00S<\/td>\n<td width=\"321\">Mounting kit<\/td>\n<td width=\"161\">940596011002<\/td>\n<\/tr>\n<tr>\n<td width=\"161\">PR 6011\/20S<\/td>\n<td width=\"321\">Mounting kit with integrated constrainer<\/td>\n<td width=\"161\">940596011202<\/td>\n<\/tr>\n<tr>\n<td width=\"161\">PR 6012\/00S<\/td>\n<td width=\"321\">Mounting kit with additional functions<\/td>\n<td width=\"161\">940536012002<\/td>\n<\/tr>\n<tr>\n<td width=\"161\">PR 6012\/20S<\/td>\n<td width=\"321\">Mounting kit with additional functions and integrated constrainer<\/td>\n<td width=\"161\">940536012202<\/td>\n<\/tr>\n<tr>\n<td width=\"161\">PR 6011\/03N<\/td>\n<td width=\"321\">Elastomeric bearing<\/td>\n<td width=\"161\">940536011031<\/td>\n<\/tr>\n<tr>\n<td width=\"161\">PR 6011\/09S<\/td>\n<td width=\"321\">Mounting adapter for installation in mounting kit with large design<\/td>\n<td width=\"161\">940536011092<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>The compact compression load cells of the PR 6211 series are specially designed for weighing vessels. Their design principle is based on a compact design which in combination with the space-saving mounting kits PR 6011 and PR 6012, enables them to be used in confined spaces.<\/p>\n","protected":false},"featured_media":287216,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5449],"product_cat":[3387],"product_tag":[4645],"class_list":{"0":"post-287233","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-minebea-intec","7":"product_cat-tension-compression-load-cell","8":"product_tag-compression-load-cell","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Minebea intec \/ Compact compression load cell PR 6211, Converter Connexx\u00ae and mounting kits PR 6011\/PR 6012 - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"The compact compression load cells of the PR 6211 series are specially designed for weighing vessels. Their design principle is based on a compact design which in combination with the space-saving mounting kits PR 6011 and PR 6012, enables them to be used in confined spaces.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/product\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Minebea intec \/ Compact compression load cell PR 6211, Converter Connexx\u00ae and mounting kits PR 6011\/PR 6012\" \/>\n<meta property=\"og:description\" content=\"The compact compression load cells of the PR 6211 series are specially designed for weighing vessels. Their design principle is based on a compact design which in combination with the space-saving mounting kits PR 6011 and PR 6012, enables them to be used in confined spaces.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/product\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/csm_load-cells-pr6211_c1547be877.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"550\" \/>\n\t<meta property=\"og:image:height\" content=\"312\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\\\/\",\"name\":\"Minebea intec \\\/ Compact compression load cell PR 6211, Converter Connexx\u00ae and mounting kits PR 6011\\\/PR 6012 - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/csm_load-cells-pr6211_c1547be877.webp\",\"datePublished\":\"2026-01-22T02:46:33+00:00\",\"description\":\"The compact compression load cells of the PR 6211 series are specially designed for weighing vessels. Their design principle is based on a compact design which in combination with the space-saving mounting kits PR 6011 and PR 6012, enables them to be used in confined spaces.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/csm_load-cells-pr6211_c1547be877.webp\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/csm_load-cells-pr6211_c1547be877.webp\",\"width\":550,\"height\":312},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Minebea intec \\\/ Compact compression load cell PR 6211, Converter Connexx\u00ae and mounting kits PR 6011\\\/PR 6012\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/product\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Minebea intec \/ Compact compression load cell PR 6211, Converter Connexx\u00ae and mounting kits PR 6011\/PR 6012 - CAS Scale Korea Co., Ltd.","description":"The compact compression load cells of the PR 6211 series are specially designed for weighing vessels. Their design principle is based on a compact design which in combination with the space-saving mounting kits PR 6011 and PR 6012, enables them to be used in confined spaces.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/product\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\/","og_locale":"en_US","og_type":"article","og_title":"Minebea intec \/ Compact compression load cell PR 6211, Converter Connexx\u00ae and mounting kits PR 6011\/PR 6012","og_description":"The compact compression load cells of the PR 6211 series are specially designed for weighing vessels. Their design principle is based on a compact design which in combination with the space-saving mounting kits PR 6011 and PR 6012, enables them to be used in confined spaces.","og_url":"https:\/\/casscale.net\/en\/product\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\/","og_site_name":"CAS Scale Korea Co., Ltd.","og_image":[{"width":550,"height":312,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/csm_load-cells-pr6211_c1547be877.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/product\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\/","url":"https:\/\/casscale.net\/en\/product\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\/","name":"Minebea intec \/ Compact compression load cell PR 6211, Converter Connexx\u00ae and mounting kits PR 6011\/PR 6012 - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/product\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/product\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/csm_load-cells-pr6211_c1547be877.webp","datePublished":"2026-01-22T02:46:33+00:00","description":"The compact compression load cells of the PR 6211 series are specially designed for weighing vessels. Their design principle is based on a compact design which in combination with the space-saving mounting kits PR 6011 and PR 6012, enables them to be used in confined spaces.","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/product\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/product\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/product\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/csm_load-cells-pr6211_c1547be877.webp","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/csm_load-cells-pr6211_c1547be877.webp","width":550,"height":312},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/product\/minebea-intec-compact-compression-load-cell-pr-6211-converter-connexx-and-mounting-kits-pr-6011-pr-6012\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/en\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"Minebea intec \/ Compact compression load cell PR 6211, Converter Connexx\u00ae and mounting kits PR 6011\/PR 6012"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/product\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/287233","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=287233"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/287216"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=287233"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=287233"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=287233"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=287233"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}