{"id":287261,"date":"2026-01-22T12:01:20","date_gmt":"2026-01-22T03:01:20","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\/"},"modified":"2026-01-22T12:01:20","modified_gmt":"2026-01-22T03:01:20","slug":"minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\/","title":{"rendered":"Minebea intec \/ Load cell PR 6212, converter Connexx\u00ae for maximum corrosion resistance"},"content":{"rendered":"<h2>Load cell PR 6212, converter Connexx\u00ae for maximum corrosion resistance<\/h2>\n<p><em>The load cell PR 6212 is a state-of-the-art product. This corrosion- resistant load cell has a compact design and also features high heat resistance. Its long product lifetime minimises downtime and ensures safer and more reliable processes in the chemical and steel industry.<\/em><\/p>\n<h4 style=\"margin-top: 0cm;\"><span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.3pt;\">Corrosion<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.3pt;\">resistance<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.3pt;\">and<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.3pt;\">precision<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.3pt;\">for<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.3pt;\">demanding<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.3pt;\">applications<\/span><\/h4>\n<ul>\n<li>\u00a0Stainless steel 1.4418, unique in weighing technology, ensures maximum corrosion resistance. The PR 6212 is also available with protective coating for use in extremely aggressive environments.<\/li>\n<li>\u00a0The perfectly coordinated combination of the load cell PR 6212 and mounting kit PR 6012 meets all precision and handling requirements. The inverted installation provides additional corrosion protection for the load cell and is simple and failure-free.<\/li>\n<li>\u00a0The compact design ensures a low system height and allows for easy retrofitting of weighing technology.<\/li>\n<\/ul>\n<p><strong><span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.2pt;\">Less<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.2pt;\">corrosion,<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.2pt;\">more<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.2pt;\">cost-efficiency<\/span><\/strong><\/p>\n<p>The combination of the load cell PR 6212 and mounting kit PR 6012 makes quick and easy installation possible and facilitates consistently reliable and precise measurement results in the chemical and steel industry.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-287237\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6212.png\" alt=\"\" width=\"1629\" height=\"937\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6212.png 1629w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6212-695x400.png 695w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6212-1391x800.png 1391w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6212-768x442.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6212-1536x884.png 1536w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6212-600x345.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6212-64x37.png 64w\" sizes=\"(max-width: 1629px) 100vw, 1629px\" \/><\/p>\n<h4>Combined for reliable installation: PR 6212 and PR 6012 as a complete solution<\/h4>\n<p>The load cell PR 6212 is not only fully compatible with all mounting kits from the PR 6012 range but also with the previous PR 6011 range. The innovative complete solution ensures failure-free and efficient installation. Thanks to the integrated jack-up function there is no need for external lifting devices and even a load cell dummy is no longer required.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-287239\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/mounting-kit-PR-6012.png\" alt=\"\" width=\"1693\" height=\"899\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/mounting-kit-PR-6012.png 1693w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/mounting-kit-PR-6012-753x400.png 753w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/mounting-kit-PR-6012-1400x743.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/mounting-kit-PR-6012-768x408.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/mounting-kit-PR-6012-1536x816.png 1536w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/mounting-kit-PR-6012-600x319.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/mounting-kit-PR-6012-64x34.png 64w\" sizes=\"(max-width: 1693px) 100vw, 1693px\" \/><\/p>\n<h4 style=\"margin-top: 0cm;\"><span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.2pt;\">Load<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.2pt;\">cell<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.2pt;\">technical<\/span> <span lang=\"EN-US\" style=\"color: #4c4d4f; letter-spacing: -.2pt;\">specifications<\/span><\/h4>\n<p>PR 6212 technical data<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"136\">Parameter<\/td>\n<td width=\"193\">Description<\/td>\n<td width=\"38\">Abbr.<\/td>\n<td width=\"108\">PR 6212\/.. LT 3)<\/p>\n<p>(high-temperature load cell)<\/td>\n<td width=\"115\">PR 6212\/.. C11)<\/p>\n<p>PR 6212\/.. C1-L2)\u00a0(load cell with protective coating)<\/td>\n<td width=\"53\">Unit<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Accuracy class<\/td>\n<td width=\"193\"><\/td>\n<td width=\"38\"><\/td>\n<td width=\"108\">0,25<\/td>\n<td width=\"115\">0,04<\/td>\n<td width=\"53\">%\u00a0Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Minimum dead load<\/td>\n<td width=\"193\">lowest limit of specified measuring range<\/td>\n<td width=\"38\">Emin<\/td>\n<td width=\"108\">0<\/td>\n<td width=\"115\">0<\/td>\n<td width=\"53\">%\u00a0Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Maximum capacity<\/td>\n<td width=\"193\">highest limit of specified measuring range<\/td>\n<td width=\"38\">Emax<\/td>\n<td width=\"108\">0,5; 1; 2; 3; 5<\/td>\n<td width=\"115\">0,5; 1; 2; 3; 5; 10<\/td>\n<td width=\"53\">t<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Safe load limit<\/td>\n<td width=\"193\">upper limit of measurements<\/td>\n<td width=\"38\">Elim<\/td>\n<td width=\"108\">150<\/td>\n<td width=\"115\">150<\/td>\n<td width=\"53\">%\u00a0Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Destructive load<\/td>\n<td width=\"193\">danger of mechanical destruction<\/td>\n<td width=\"38\">E<sub>d<\/sub><\/td>\n<td width=\"108\">&gt;300<\/td>\n<td width=\"115\">&gt;300<\/td>\n<td width=\"53\">%\u00a0Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Minimum LC verification<\/td>\n<td width=\"193\">minimum load cell scale interval, vmin = Emax\/Y<\/td>\n<td width=\"38\">Y<\/td>\n<td width=\"108\">&#8211;<\/td>\n<td width=\"115\">5000<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Rated output<\/td>\n<td width=\"193\">relative output at maximum capacity<\/td>\n<td width=\"38\">C<sub>n<\/sub><\/td>\n<td width=\"108\">2<\/td>\n<td width=\"115\">2<\/td>\n<td width=\"53\">mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Tolerance on rated output<\/td>\n<td width=\"193\">permissible deviation from rated output Cn<\/td>\n<td width=\"38\">d<sub>c<\/sub><\/td>\n<td width=\"108\">&lt;1,5<\/td>\n<td width=\"115\">&lt;0,25<\/td>\n<td width=\"53\">% C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Zero output signal<\/td>\n<td width=\"193\">load cell output signal under unloaded condition<\/td>\n<td width=\"38\">Smin<\/td>\n<td width=\"108\">0\u00b12<\/td>\n<td width=\"115\">0\u00b12<\/td>\n<td width=\"53\">% Cn<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Reproducibility<\/td>\n<td width=\"193\">max. change in load cell output for repeated loading<\/td>\n<td width=\"38\">\u03b5<sub>R<\/sub><\/td>\n<td width=\"108\">&lt;0,1<\/td>\n<td width=\"115\">&lt;0,01<\/td>\n<td width=\"53\">% C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Creep<\/td>\n<td width=\"193\">max. change of output signal at Emax\u00a0during 30 minutes<\/td>\n<td width=\"38\">dcr<\/td>\n<td width=\"108\">&lt;0,1<\/td>\n<td width=\"115\">&lt;0,035<\/td>\n<td width=\"53\">% C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Linearity deviation4)<\/td>\n<td width=\"193\">deviation from best straight line through zero<\/td>\n<td width=\"38\">dLin<\/td>\n<td width=\"108\">&lt;0,25<\/td>\n<td width=\"115\">&lt;0,03<\/td>\n<td width=\"53\">% C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Hysteresis4)<\/td>\n<td width=\"193\">max. difference in LC output between loading and unloading<\/td>\n<td width=\"38\">dhy<\/td>\n<td width=\"108\">&lt;0,25<\/td>\n<td width=\"115\">&lt;0,035<\/td>\n<td width=\"53\">% C<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Temperature effect on S<sub>min<\/sub><\/td>\n<td width=\"193\">max. change of S<sub>min<\/sub> per 10 K over BT referred to C<sub>n<\/sub><\/td>\n<td width=\"38\">TKSmin<\/td>\n<td width=\"108\">&lt;0,1<\/td>\n<td width=\"115\">&lt;0,028<\/td>\n<td width=\"53\">% C<sub>n<\/sub>\/10 K<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Temperature effect on C4)<\/td>\n<td width=\"193\">max. change of C per 10 K over B<sub>T<\/sub> referred to C<sub>n<\/sub><\/td>\n<td width=\"38\">TK<sub>C<\/sub><\/td>\n<td width=\"108\">&lt;0,07<\/td>\n<td width=\"115\">&lt;0,02<\/td>\n<td width=\"53\">% C<sub>n<\/sub>\/10 K<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Input impedance<\/td>\n<td width=\"193\">between supply terminals<\/td>\n<td width=\"38\">RLC<\/td>\n<td width=\"108\">1200 \u00b1200<\/td>\n<td width=\"115\">650 \u00b16<\/td>\n<td width=\"53\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Output impedance<\/td>\n<td width=\"193\">between measuring terminals<\/td>\n<td width=\"38\">R<sub>0<\/sub><\/td>\n<td width=\"108\">1200 \u00b16<\/td>\n<td width=\"115\">610 \u00b11<\/td>\n<td width=\"53\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Insulation impedance<\/td>\n<td width=\"193\">between measuring circuit and housing at 100 V DC<\/td>\n<td width=\"38\">RIS<\/td>\n<td width=\"108\">&gt;5000<\/td>\n<td width=\"115\">&gt;5000<\/td>\n<td width=\"53\">M \u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Insulation voltage<\/td>\n<td width=\"193\">between circuit and housing (PR 6212\/..E only)<\/td>\n<td width=\"38\"><\/td>\n<td width=\"108\">&#8211;<\/td>\n<td width=\"115\">500<\/td>\n<td width=\"53\">V<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Recommended supply voltage<\/td>\n<td width=\"193\">to hold the specified performance<\/td>\n<td width=\"38\">B<sub>u<\/sub><\/td>\n<td width=\"108\">4&#8230;24<\/td>\n<td width=\"115\">4&#8230;24<\/td>\n<td width=\"53\">V<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Max. supply voltage<\/td>\n<td width=\"193\">permissible for continuous operation without damage<\/p>\n<p>PR 6212\/..E<\/td>\n<td width=\"38\">Umax<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Umax<\/td>\n<td width=\"108\">32<\/p>\n<p>&nbsp;<\/p>\n<p>&#8211;<\/td>\n<td width=\"115\">32<\/p>\n<p>&nbsp;<\/p>\n<p>25<\/td>\n<td width=\"53\">V<\/p>\n<p>&nbsp;<\/p>\n<p>V<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Nominal ambient temp. range<\/td>\n<td width=\"193\">to hold the specified performance<\/td>\n<td width=\"38\">B<sub>T<\/sub><\/td>\n<td width=\"108\">-10&#8230;+155<\/td>\n<td width=\"115\">-10&#8230;+40<\/td>\n<td width=\"53\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Service temperature range<\/td>\n<td width=\"193\">permissible for continuous operation without damage<\/td>\n<td width=\"38\">BTu<\/td>\n<td width=\"108\">-30&#8230;+180<\/td>\n<td width=\"115\">-30&#8230;+95<\/td>\n<td width=\"53\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Storage temperature range<\/td>\n<td width=\"193\">without electrical and mechanical stress<\/td>\n<td width=\"38\">BTi<\/td>\n<td width=\"108\">-40&#8230;+180<\/td>\n<td width=\"115\">-40&#8230;+95<\/td>\n<td width=\"53\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Permissible inclination<\/td>\n<td width=\"193\">permissible inclination whilst maintaining the specified measurement accuracy<\/td>\n<td width=\"38\"><\/td>\n<td width=\"108\">1<\/td>\n<td width=\"115\">1<\/td>\n<td width=\"53\">angle in \u00b0<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Vibration resistance<\/td>\n<td width=\"193\">resistance against oscillations (IEC 60068-2-6-Fc)<\/td>\n<td width=\"38\"><\/td>\n<td width=\"108\">20 g, 100 h, 10&#8230;150 Hz<\/td>\n<td width=\"115\">20 g, 100 h, 10&#8230;150 Hz<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Ambient pressure impact<\/td>\n<td width=\"193\">influence of ambient air pressure on Smin<\/td>\n<td width=\"38\">PKSmin<\/td>\n<td width=\"108\">\u226470<\/td>\n<td width=\"115\">\u226460<\/td>\n<td width=\"53\">g\/kPa<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Nominal deflection<\/td>\n<td width=\"193\">elastic deformation under maximum capacity<\/td>\n<td width=\"38\">snom<\/td>\n<td width=\"108\">&lt;0,2<\/td>\n<td width=\"115\">&lt;0,2<\/td>\n<td width=\"53\">mm<\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Material (sensor)<\/td>\n<td width=\"193\"><\/td>\n<td width=\"38\"><\/td>\n<td width=\"108\">1.4542 (DIN EN 10088-3)<\/td>\n<td width=\"115\">1.4418 (DIN EN 10088-3)<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Protection class<\/td>\n<td width=\"193\"><\/td>\n<td width=\"38\"><\/td>\n<td colspan=\"3\" width=\"276\">according to IEC 529<\/p>\n<p>\u2013 PR 6212: IP68*\/IP69<\/p>\n<p>\u2013 Connexx\u00ae: IP65 \/ IP 68**<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"136\">Cables<\/td>\n<td rowspan=\"2\" width=\"193\"><\/td>\n<td width=\"38\"><\/td>\n<td colspan=\"3\" width=\"276\">robust, flexible, shielded, length: 5 m<\/td>\n<\/tr>\n<tr>\n<td width=\"38\"><\/td>\n<td width=\"108\">PR 6212\/.. LT<\/p>\n<p>PFA, colour: red,<\/p>\n<p>\u00d8 5 mm, 4 x 0,382 mm2<\/td>\n<td width=\"115\">PR 6212\/.. C1<\/p>\n<p>TPE, colour: grey,<\/p>\n<p>\u00d8 5 mm, 4 x 0,355 mm2<\/p>\n<p>PR 6212\/C1E<\/p>\n<p>TPE, colour: blue,<\/p>\n<p>\u00d8 5 mm, 4 x 0,382 mm<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"136\">Bending radius<\/td>\n<td width=\"193\"><\/td>\n<td width=\"38\"><\/td>\n<td colspan=\"3\" width=\"276\">fixed installation \u226550 mm, flexible installation \u2265150 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>1)\u00a0C1 = load cell with C1 measurement accuracy | 2) C1-L = load cell with C1 measurement accuracy and special protective coating | 3)\u00a0LT = high-temperature version<\/p>\n<p>4)\u00a0The data for Non-linearity, hysteresis and TKC are typical values. For OIML R60 or NTEP approved load cells the sum of these values is within the permissible cumulative error limits.<\/p>\n<p>Connexx\u00ae<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"197\">Nominal ambient temp. range<\/td>\n<td width=\"233\">To hold the specified performance<\/td>\n<td width=\"30\">BT<\/td>\n<td width=\"153\">-10 \u2026 +40<\/td>\n<td width=\"30\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Usable temperature range<\/td>\n<td width=\"233\">Permissible for continuous operation without damage<\/td>\n<td width=\"30\">BTu<\/td>\n<td width=\"153\">-30 \u2026 +60<\/td>\n<td width=\"30\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Storage temperature range<\/td>\n<td width=\"233\">Without electrical and mechanical stress<\/td>\n<td width=\"30\">BTi<\/td>\n<td width=\"153\">-30 \u2026 +70<\/td>\n<td width=\"30\">\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* The load cell can be submerged in water at a depth of 1.5 m for 10,000 hours. | ** The module can be submerged in water at a depth of 1.5 m for 100 hours.<\/p>\n<h1><span lang=\"EN-US\" style=\"color: #4c4d4f;\">Mounting kit technical <span style=\"letter-spacing: -.1pt;\">specifications<\/span><\/span><\/h1>\n<table>\n<tbody>\n<tr>\n<td colspan=\"11\" width=\"642\">PR 6012 technical data<\/td>\n<\/tr>\n<tr>\n<td width=\"34\">Maximum capacity of load cell PR 6212<\/td>\n<td width=\"79\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Mounting kit\/ accessories<\/td>\n<td width=\"94\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Material<\/td>\n<td width=\"128\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Description\/comments<\/td>\n<td width=\"38\">&nbsp;<\/p>\n<p>Mounting screws<\/td>\n<td width=\"38\">&nbsp;<\/p>\n<p>Installation height<\/td>\n<td width=\"38\">Max. permissible horizontal force (kN)<\/td>\n<td width=\"68\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Horizontal destruc- tive force [KN]<\/td>\n<td width=\"38\">Max. permissible lift-off force (kN)<\/td>\n<td width=\"38\">Maximum permissi- ble ecce,ntricity<\/td>\n<td width=\"49\">Max. permissible vertical load without load cell<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"34\">&nbsp;<\/p>\n<p>500kg &#8211; 10t<\/td>\n<td width=\"79\">PR 6012\/01 N, S<\/td>\n<td rowspan=\"3\" width=\"94\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Steel S235, stainless steel 1.4301 (AISI<\/p>\n<p>304)<\/td>\n<td width=\"128\">Mini FLEX<\/td>\n<td width=\"38\">M8<\/td>\n<td width=\"38\">80<\/p>\n<p>mm<\/td>\n<td width=\"38\">\/<\/td>\n<td width=\"68\">\/<\/td>\n<td width=\"38\">\/<\/td>\n<td width=\"38\">+\/- 4<\/p>\n<p>mm<\/td>\n<td width=\"49\">\/<\/td>\n<\/tr>\n<tr>\n<td width=\"79\">PR 6012\/31 N, S<\/td>\n<td width=\"128\">Mini FLEXLOCK<\/td>\n<td width=\"38\">M8<\/td>\n<td width=\"38\">80<\/p>\n<p>mm<\/td>\n<td width=\"38\">5<\/td>\n<td width=\"68\">10<\/td>\n<td width=\"38\">\/<\/td>\n<td width=\"38\">+\/- 4<\/p>\n<p>mm<\/td>\n<td width=\"49\">\/<\/td>\n<\/tr>\n<tr>\n<td width=\"79\">PR 6012\/41 N, S<\/td>\n<td width=\"128\">Mini FLEXLOCK; reinforced constrainer<\/td>\n<td width=\"38\">M12<\/td>\n<td width=\"38\">80<\/p>\n<p>mm<\/td>\n<td width=\"38\">20<\/td>\n<td width=\"68\">50<\/td>\n<td width=\"38\">\/<\/td>\n<td width=\"38\">+\/- 4<\/p>\n<p>mm<\/td>\n<td width=\"49\">\/<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" width=\"34\">&nbsp;<\/p>\n<p>500kg &#8211; 10t<\/td>\n<td width=\"79\">PR 6012\/02 N, S<\/td>\n<td rowspan=\"3\" width=\"94\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Steel S235, stainless steel 1.4301 (AISI<\/p>\n<p>304)<\/td>\n<td width=\"128\">Maxi FLEX<\/td>\n<td width=\"38\">M8<\/td>\n<td width=\"38\">80<\/p>\n<p>mm<\/td>\n<td width=\"38\">\/<\/td>\n<td width=\"68\">\/<\/td>\n<td width=\"38\">10<\/td>\n<td width=\"38\">+\/- 4<\/p>\n<p>mm<\/td>\n<td width=\"49\">5 t<\/td>\n<\/tr>\n<tr>\n<td width=\"79\">PR 6012\/32 N, S<\/td>\n<td width=\"128\">Maxi FLEXLOCK<\/td>\n<td width=\"38\">M8<\/td>\n<td width=\"38\">80<\/p>\n<p>mm<\/td>\n<td width=\"38\">5<\/td>\n<td width=\"68\">10<\/td>\n<td width=\"38\">10<\/td>\n<td width=\"38\">+\/- 4<\/p>\n<p>mm<\/td>\n<td width=\"49\">5 t<\/td>\n<\/tr>\n<tr>\n<td width=\"79\">PR 6012\/42 N, S<\/td>\n<td width=\"128\">Maxi FLEXLOCK; reinforced constrainer<\/td>\n<td width=\"38\">M12<\/td>\n<td width=\"38\">80<\/p>\n<p>mm<\/td>\n<td width=\"38\">20<\/td>\n<td width=\"68\">50<\/td>\n<td width=\"38\">10<\/td>\n<td width=\"38\">+\/- 4<\/p>\n<p>mm<\/td>\n<td width=\"49\">5 t<\/td>\n<\/tr>\n<tr>\n<td width=\"79\">&nbsp;<\/p>\n<p>PR 6012\/53 S<\/td>\n<td rowspan=\"2\" width=\"94\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Stainless steel A2-70<\/td>\n<td width=\"128\">Optional extension of lift-off protection (M12) for PR 6012\/31 and PR 6012\/32<\/td>\n<td width=\"38\">&nbsp;<\/p>\n<p>\/<\/td>\n<td width=\"38\">&nbsp;<\/p>\n<p>\/<\/td>\n<td width=\"38\">&nbsp;<\/p>\n<p>\/<\/td>\n<td width=\"68\">&nbsp;<\/p>\n<p>\/<\/td>\n<td width=\"38\">&nbsp;<\/p>\n<p>25<\/td>\n<td width=\"38\">&nbsp;<\/p>\n<p>&#8211;<\/td>\n<td width=\"49\">&nbsp;<\/p>\n<p>\/<\/td>\n<\/tr>\n<tr>\n<td width=\"79\">&nbsp;<\/p>\n<p>PR 6012\/54 S<\/td>\n<td width=\"128\">Optional extension of lift-off protection (M16) for PR 6012\/41 and PR 6012\/42<\/td>\n<td width=\"38\">&nbsp;<\/p>\n<p>\/<\/td>\n<td width=\"38\">&nbsp;<\/p>\n<p>\/<\/td>\n<td width=\"38\">&nbsp;<\/p>\n<p>\/<\/td>\n<td width=\"68\">&nbsp;<\/p>\n<p>\/<\/td>\n<td width=\"38\">&nbsp;<\/p>\n<p>45<\/td>\n<td width=\"38\">&nbsp;<\/p>\n<p>&#8211;<\/td>\n<td width=\"49\">&nbsp;<\/p>\n<p>\/<\/td>\n<\/tr>\n<tr>\n<td width=\"79\">PR 6012\/63 S<\/td>\n<td width=\"94\">Stainless steel 1.4301 (AISI 304)<\/td>\n<td width=\"128\">Pivot for<\/p>\n<p>PR 6212\/ 500 kg &#8211; 10 t<\/td>\n<td width=\"38\">M8<\/td>\n<td width=\"38\">80<\/p>\n<p>mm<\/td>\n<td width=\"38\">12<\/td>\n<td width=\"68\">70<\/td>\n<td width=\"38\">\/<\/td>\n<td width=\"38\">\/<\/td>\n<td width=\"49\">\/<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Converter Connexx\u00ae<\/strong><\/p>\n<p><img decoding=\"async\" class=\"wp-image-287217 alignleft\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Mounting-kits-PR-6011.png\" alt=\"\" width=\"556\" height=\"403\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Mounting-kits-PR-6011.png 1039w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Mounting-kits-PR-6011-552x400.png 552w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Mounting-kits-PR-6011-768x557.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Mounting-kits-PR-6011-600x435.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Mounting-kits-PR-6011-64x46.png 64w\" sizes=\"(max-width: 556px) 100vw, 556px\" \/><\/p>\n<p>Fitted with the converter Connexx\u00ae, the load cell PR 6212 offers a whole host of possibilities:<\/p>\n<ul>\n<li>\u00a0The digital version guarantees fast signalling times for reliable dosing processes.<\/li>\n<li>\u00a0Thanks to the use of field bus communication, the cable junction box is no longer needed.<\/li>\n<li>\u00a0The standard interface CANopen ensures straightforward installation and calibration.<\/li>\n<li>\u00a0CANopen allows for extra-long communication paths of up to 200 m.<\/li>\n<li>\u00a0Weight values can also be generated individually \u2013 per load cell \u2013 meaning that defective load cells can be identified m<\/li>\n<\/ul>\n<p>The mounting kit PR 6012\/X1 was developed for use in the toughest conditions. The inverted installation of the load cell combined with the special high-quality material of the mounting kit make a complete solution capable of withstanding chemically aggressive, corrosive environments. The measurement results are also not affected by temperature fluctuations thanks to large lateral tolerances and the integrated horizontal constrainer. What\u2018s more, the mounting kit was designed to be especially easy and reliable to install.<\/p>\n<table>\n<thead>\n<tr>\n<th>PR 6212<\/th>\n<th>Converter Connexx\u00ae<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-287242\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6212-1.png\" alt=\"\" width=\"750\" height=\"398\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6212-1.png 750w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6212-1-600x318.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6212-1-64x34.png 64w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-287244\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Converter-Connexx\u00ae.png\" alt=\"\" width=\"753\" height=\"405\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Converter-Connexx\u00ae.png 753w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Converter-Connexx\u00ae-744x400.png 744w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Converter-Connexx\u00ae-600x323.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/Converter-Connexx\u00ae-64x34.png 64w\" sizes=\"(max-width: 753px) 100vw, 753px\" \/><\/td>\n<\/tr>\n<tr>\n<td>PR 6012\/63 S<\/td>\n<td>PR 6012\/01 N, S<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-287246\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-63-S.png\" alt=\"\" width=\"749\" height=\"617\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-63-S.png 749w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-63-S-486x400.png 486w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-63-S-600x494.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-63-S-64x53.png 64w\" sizes=\"(max-width: 749px) 100vw, 749px\" \/><\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-287248\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-01-N-S.png\" alt=\"\" width=\"745\" height=\"629\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-01-N-S.png 745w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-01-N-S-474x400.png 474w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-01-N-S-295x250.png 295w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-01-N-S-600x507.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-01-N-S-64x54.png 64w\" sizes=\"(max-width: 745px) 100vw, 745px\" \/><\/td>\n<\/tr>\n<tr>\n<td>PR 6012\/31 N, S<\/td>\n<td>PR 6012\/41 N, S<\/td>\n<\/tr>\n<tr>\n<td>\n<ul>\n<li><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-287251\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-31-N-S.png\" alt=\"\" width=\"753\" height=\"730\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-31-N-S.png 753w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-31-N-S-413x400.png 413w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-31-N-S-600x582.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-31-N-S-64x62.png 64w\" sizes=\"(max-width: 753px) 100vw, 753px\" \/><\/li>\n<\/ul>\n<\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-287253\" style=\"font-size: 18px;\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-41-N-S.png\" alt=\"\" width=\"753\" height=\"703\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-41-N-S.png 753w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-41-N-S-428x400.png 428w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-41-N-S-600x560.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-41-N-S-64x60.png 64w\" sizes=\"(max-width: 753px) 100vw, 753px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4><span lang=\"EN-US\" style=\"color: #4c4d4f;\">Mounting kit PR 6012\/X2 dimensional <span style=\"letter-spacing: -.1pt;\">drawings<\/span><\/span><\/h4>\n<p>In addition to the features of the PR 6012\/X1 the mounting kit PR 6012\/X2 range also has extensive additional functions that make installation and operation of the weighing technology easier. The integrated jack-up function eliminates the need for external lifting devices, while the integrated dummy function makes easy installation possible \u2013 without damaging the sensitive load cell. Lift-off protection up to 45 kN effectively prevents the vessel from tipping.<\/p>\n<p>&nbsp;<\/p>\n<table>\n<thead>\n<tr>\n<th>PR 6012\/02 N, S<\/th>\n<th>PR 6012\/32 N, S<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-287255\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-32-N-S.png\" alt=\"\" width=\"774\" height=\"706\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-32-N-S.png 774w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-32-N-S-439x400.png 439w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-32-N-S-768x701.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-32-N-S-600x547.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-32-N-S-64x58.png 64w\" sizes=\"(max-width: 774px) 100vw, 774px\" \/><\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-287257\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-02-N-S.png\" alt=\"\" width=\"784\" height=\"728\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-02-N-S.png 784w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-02-N-S-431x400.png 431w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-02-N-S-768x713.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-02-N-S-600x557.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-02-N-S-64x59.png 64w\" sizes=\"(max-width: 784px) 100vw, 784px\" \/><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">PR 6012\/42 N, S<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-287259\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-42-N-S.png\" alt=\"\" width=\"1557\" height=\"1091\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-42-N-S.png 1557w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-42-N-S-571x400.png 571w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-42-N-S-1142x800.png 1142w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-42-N-S-768x538.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-42-N-S-1536x1076.png 1536w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-42-N-S-600x420.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/PR-6012-42-N-S-64x45.png 64w\" sizes=\"(max-width: 1557px) 100vw, 1557px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Approvals<\/strong><br \/>\nScope of validity:<br \/>\nPR 6212\/\u2026 C1E (500 kg \u2026 10 t)<\/p>\n<p>Certificates for the load cell<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"76\">Zone<\/td>\n<td width=\"227\">Labeling<\/td>\n<td width=\"170\">Certificate number<\/td>\n<td width=\"170\">for<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">0 and 1<\/td>\n<td width=\"227\">II 1G Ex ia IIC T6 Ga<\/p>\n<p>Ex ia IIC T6 Ga OEx ia IIC T6 (&#8220;)<\/td>\n<td width=\"170\">BVS 16 ATEX E 005<\/p>\n<p>IECEx BVS 16.0005<\/td>\n<td width=\"170\">PR 6212\/..E only<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">20 and 21<\/td>\n<td width=\"227\">II 1D Ex ta IIIC T160\u00b0C Da Ex ta IIIC T160 \u00b0C Da<\/p>\n<p>Ex ta IIIC T160 \u00b0C X (&#8220;)<\/td>\n<td width=\"170\">T\u00dcV 03 ATEX 2301 X IECEx TUN 17.0025X<\/td>\n<td width=\"170\">PR 6212\/..E only<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">2<\/td>\n<td width=\"227\">II 3G Ex nA IIC T6 Gc 2 Ex nA IIC T6 X (&#8220;)<\/td>\n<td width=\"170\">Certificate manufacturer<\/td>\n<td width=\"170\">all PR 6212 except LT version<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">22<\/td>\n<td width=\"227\">II 3D Ex tc IIIC T85 \u00b0C Dc Ex tc IIIC T6 X (&#8220;)<\/td>\n<td width=\"170\">Certificate manufacturer<\/td>\n<td width=\"170\">all PR 6212 except LT version<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">&nbsp;<\/td>\n<td width=\"227\">IS \/ I,II,III \/ 1 \/ ABCDEFG \/ T4A<\/p>\n<p>Ta= -30 \u00b0C to 70 \u00b0C; T5 Ta= -30 \u00b0C to 55 \u00b0C &#8211; 4012 101 5688; Entity<\/p>\n<p>NI \/ I,II,III \/ 2 \/ ABCDEFG \/ T4A<\/p>\n<p>Ta= -30 \u00b0C to 70 \u00b0C; T5 Ta= -30 \u00b0C to 55 \u00b0C &#8211; 4012 101 5688; NIFW<\/td>\n<td width=\"170\">FM &#8211; Original project ID: 3001200<\/td>\n<td width=\"170\">all PR 6212 except LT version<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">&nbsp;<\/td>\n<td width=\"227\">IS \/ I,II,III \/ 1 \/ ABCDEFG \/ T4A<\/p>\n<p>Ta= -30 \u00b0C to 70 \u00b0C; T5 Ta= -30 \u00b0C to 55 \u00b0C &#8211; 4012 101 5688; Entity<\/p>\n<p>NI \/ I \/ 2 \/ ABCD \/ T4A<\/p>\n<p>Ta= -30 \u00b0C to 70\u00b0C; T5 Ta= -30 \u00b0C to 55 \u00b0C &#8211; 4012 101 5688; NIFW<\/p>\n<p>DIP \/ II,III \/ 2 \/ EFG \/ T4A<\/p>\n<p>Ta= -30 \u00b0C to 70 \u00b0C; T5 Ta= -30 \u00b0C to 55 \u00b0C &#8211; 4012 101 5688; NIFW<\/td>\n<td width=\"170\">FM &#8211; Canada project ID: 3053046<\/td>\n<td width=\"170\">all PR 6212 except LT version<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">&nbsp;<\/td>\n<td width=\"227\">Ambient temperature in Ex-Area -30&#8230; +55 \u00b0C<\/td>\n<td width=\"170\">&nbsp;<\/td>\n<td width=\"170\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">&nbsp;<\/td>\n<td width=\"227\">(&#8220;) only with approval TP TC 012 (TRCU 012)<\/p>\n<p>-52&#8230;+55 \u00b0C<\/td>\n<td width=\"170\">&nbsp;<\/td>\n<td width=\"170\">&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Ordering information<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"6\" width=\"642\">Load cell PR 6212<\/td>\n<\/tr>\n<tr>\n<td width=\"106\">Type<\/td>\n<td width=\"106\">Order number<\/td>\n<td width=\"110\">Type<\/td>\n<td width=\"106\">Order number<\/td>\n<td width=\"110\">Type<\/td>\n<td width=\"106\">Order number<\/td>\n<\/tr>\n<tr>\n<td width=\"106\">PR 6212\/500 kg C1<\/td>\n<td width=\"106\">940521201150<\/td>\n<td width=\"110\">PR 6212\/2 t C1<\/td>\n<td width=\"106\">940521201220<\/td>\n<td width=\"110\">PR 6212\/5 t C1<\/td>\n<td width=\"106\">940521201250<\/td>\n<\/tr>\n<tr>\n<td width=\"106\">PR 6212\/500 kg C1E<\/td>\n<td width=\"106\">940561201150<\/td>\n<td width=\"110\">PR 6212\/2 t C1E<\/td>\n<td width=\"106\">940561201220<\/td>\n<td width=\"110\">PR 6212\/5 t C1E<\/td>\n<td width=\"106\">940561201250<\/td>\n<\/tr>\n<tr>\n<td width=\"106\">PR 6212\/500 kg C1-L<\/td>\n<td width=\"106\">940581201150<\/td>\n<td width=\"110\">PR 6212\/2 t C1-L<\/td>\n<td width=\"106\">940581201220<\/td>\n<td width=\"110\">PR 6212\/5 t C1-L<\/td>\n<td width=\"106\">940581201250<\/td>\n<\/tr>\n<tr>\n<td width=\"106\">PR 6212\/500 kg LT<\/td>\n<td width=\"106\">940541201150<\/td>\n<td width=\"110\">PR 6212\/2 t LT<\/td>\n<td width=\"106\">940541201220<\/td>\n<td width=\"110\">PR 6212\/5 t LT<\/td>\n<td width=\"106\">940541201250<\/td>\n<\/tr>\n<tr>\n<td width=\"106\">PR 6212\/1 t C1<\/td>\n<td width=\"106\">940521201210<\/td>\n<td width=\"110\">PR 6212\/3 t C1<\/td>\n<td width=\"106\">940521201230<\/td>\n<td width=\"110\">PR 6212\/10 t C1<\/td>\n<td width=\"106\">940521201310<\/td>\n<\/tr>\n<tr>\n<td width=\"106\">PR 6212\/1 t C1E<\/td>\n<td width=\"106\">940561201210<\/td>\n<td width=\"110\">PR 6212\/3 t C1E<\/td>\n<td width=\"106\">940561201230<\/td>\n<td width=\"110\">PR 6212\/10 t C1E<\/td>\n<td width=\"106\">940561201310<\/td>\n<\/tr>\n<tr>\n<td width=\"106\">PR 6212\/1 t C1-L<\/td>\n<td width=\"106\">940581201210<\/td>\n<td width=\"110\">PR 6212\/3 t C1-L<\/td>\n<td width=\"106\">940581201230<\/td>\n<td width=\"110\">PR 6212\/10 t C1-L<\/td>\n<td width=\"106\">940581201310<\/td>\n<\/tr>\n<tr>\n<td width=\"106\">PR 6212\/1 t LT<\/td>\n<td width=\"106\">940541201210<\/td>\n<td width=\"110\">PR 6212\/3 t LT<\/td>\n<td width=\"106\">940541201230<\/td>\n<td colspan=\"2\" width=\"215\">&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"3\" width=\"642\">Load cell PR 6212, converter Connexx\u00ae<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">Type<\/td>\n<td width=\"306\">Description<\/td>\n<td width=\"178\">Order number<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6212\/DIGITAL KIT<\/td>\n<td width=\"306\">The converter Connexx\u00ae\u00a0can only be ordered with the above-mentioned load cells from the PR 6212 series. When ordering, both order numbers need to be given.<\/td>\n<td width=\"178\">940511200000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional information:<br \/>\nThe converters Connexx\u00ae\u00a0can be used with the Indicator X3.<br \/>\nTo do this, the indicator X3 must be equipped with a CANopen interface card PR 5510\/05 (940535510051).<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"3\" width=\"642\">Load cell PR 6212, converter Connexx\u00ae\u00a0\u2013 application sets<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">Type<\/td>\n<td width=\"306\">Description<\/td>\n<td width=\"178\">Order number<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6154\/03<\/td>\n<td width=\"306\">Application set for 3 load cells.<\/p>\n<p>Includes: 2 \u00d7 PR 6155\/05, 1 \u00d7 PR 6152\/25, 1 \u00d7 PR 6153\/99<\/td>\n<td width=\"178\">940536154031<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6154\/04<\/td>\n<td width=\"306\">Application set for 4 load cells.<\/p>\n<p>Includes: 3 \u00d7 PR 6155\/05, 1 \u00d7 PR 6152\/25, 1 \u00d7 PR 6153\/99<\/td>\n<td width=\"178\">940536154041<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"3\" width=\"642\">Load cell PR 6212, converter Connexx\u00ae\u00a0\u2013 load cell accessories<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">Type<\/td>\n<td width=\"306\">Description<\/td>\n<td width=\"178\">Order number<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6152\/10<\/td>\n<td width=\"306\">Connection cable between Connexx\u00ae\u00a0and X3 (10 m)<\/td>\n<td width=\"178\">940536152101<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6152\/25<\/td>\n<td width=\"306\">Connection cable between Connexx\u00ae\u00a0and X3 (25 m)<\/td>\n<td width=\"178\">940536152251<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6152\/40<\/td>\n<td width=\"306\">Connection cable between Connexx\u00ae\u00a0and X3 (40 m)<\/td>\n<td width=\"178\">940536152401<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6153\/98<\/td>\n<td width=\"306\">Divided cable gland<\/td>\n<td width=\"178\">940536153981<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6153\/99<\/td>\n<td width=\"306\">Terminal resistor for Connexx\u00ae, M12<\/td>\n<td width=\"178\">940536153991<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6155\/05<\/td>\n<td width=\"306\">Connection cable between Connexx\u00ae\u00a0and Connexx\u00ae\u00a0(5 m)<\/td>\n<td width=\"178\">940536155051<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6155\/10<\/td>\n<td width=\"306\">Connection cable between Connexx\u00ae\u00a0and Connexx\u00ae\u00a0(10 m)<\/td>\n<td width=\"178\">940536155101<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"3\" width=\"642\">Mounting kit PR 6012<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"642\">Mounting kits without integrated constrainer<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">Type<\/td>\n<td width=\"306\">Description<\/td>\n<td width=\"178\">Order number<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6012\/01 N<\/td>\n<td width=\"306\">Mounting kit Mini FLEX for PR 6212\/500 kg \u2013 10 t<\/td>\n<td width=\"178\">940536012011<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6012\/01 S<\/td>\n<td width=\"306\">Mounting kit Mini FLEX for PR 6212\/500 kg \u2013 10 t, stainless steel<\/td>\n<td width=\"178\">940536012012<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"642\">Mounting kits with integrated constrainer<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">Type<\/td>\n<td width=\"306\">Description<\/td>\n<td width=\"178\">Order number<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6012\/31 N<\/td>\n<td width=\"306\">Mounting kit Mini FLEXLOCK for PR 6212\/500 kg \u2013 10 t<\/td>\n<td width=\"178\">940536012311<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6012\/31 S<\/td>\n<td width=\"306\">Mounting kit Mini FLEXLOCK for PR 6212\/500 kg \u2013 10 t, stainless steel<\/td>\n<td width=\"178\">940536012312<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6012\/41 N<\/td>\n<td width=\"306\">Mounting kit Mini FLEXLOCK for PR 6212\/500 kg \u2013 10 t<\/td>\n<td width=\"178\">940536012411<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6012\/41 S<\/td>\n<td width=\"306\">Mounting kit Mini FLEXLOCK for PR 6212\/500 kg \u2013 10 t, stainless steel<\/td>\n<td width=\"178\">940536012412<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"642\">Mounting kit with additional functions and without integrated constrainer<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">Type<\/td>\n<td width=\"306\">Description<\/td>\n<td width=\"178\">Order number<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6012\/02 N<\/td>\n<td width=\"306\">Mounting kit Maxi FLEX for PR 6212\/500 kg \u2013 10 t<\/td>\n<td width=\"178\">940536012021<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6012\/02 S<\/td>\n<td width=\"306\">Mounting kit Maxi FLEX for PR 6212\/500 kg \u2013 10 t, stainless steel<\/td>\n<td width=\"178\">940536012022<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"642\">Mounting kit with additional functions and integrated constrainer<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">Type<\/td>\n<td width=\"306\">Description<\/td>\n<td width=\"178\">Order number<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6012\/32 N<\/td>\n<td width=\"306\">Mounting kit Maxi FLEXLOCK for PR 6212\/500 kg \u2013 10 t<\/td>\n<td width=\"178\">940536012321<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6012\/32 S<\/td>\n<td width=\"306\">Mounting kit Maxi FLEXLOCK for PR 6212\/500 kg \u2013 10 t, stainless steel<\/td>\n<td width=\"178\">940536012322<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6012\/42 N<\/td>\n<td width=\"306\">Mounting kit Maxi FLEXLOCK for PR 6212\/500 kg \u2013 10 t<\/td>\n<td width=\"178\">940536012421<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6012\/42 S<\/td>\n<td width=\"306\">Mounting kit Maxi FLEXLOCK for PR 6212\/500 kg \u2013 10 t, stainless steel<\/td>\n<td width=\"178\">940536012422<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6012\/53 S<\/td>\n<td width=\"306\">Optional extension of lift-off protection (M12) for PR 6012\/31 and PR 6012\/32<\/td>\n<td width=\"178\">940536012532<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6012\/54 S<\/td>\n<td width=\"306\">Optional extension of lift-off protection (M16) for PR 6012\/41 and PR 6012\/42<\/td>\n<td width=\"178\">940536012542<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">PR 6012\/63 S<\/td>\n<td width=\"306\">Pivot for PR 6212\/500 kg \u2013 10 t<\/td>\n<td width=\"178\">940536012632<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Load cell PR 6212 benefits<\/p>\n<ul>\n<li>Maximum corrosion resistance<\/li>\n<li>High-temperature version available for up to 180 \u00b0C<\/li>\n<li>Easy and failure-free installation using the mounting kit PR 6012<\/li>\n<\/ul>\n<p>Mounting kit PR 6012 benefits<\/p>\n<ul>\n<li>Integrated jack-up and dummy function<\/li>\n<li>Low installation height<\/li>\n<\/ul>\n","protected":false},"featured_media":287236,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5449],"product_cat":[3387],"product_tag":[4645],"class_list":{"0":"post-287261","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-minebea-intec","7":"product_cat-tension-compression-load-cell","8":"product_tag-compression-load-cell","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Minebea intec \/ Load cell PR 6212, converter Connexx\u00ae for maximum corrosion resistance - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"Load cell PR 6212 benefits   Maximum corrosion resistance  High-temperature version available for up to 180 \u00b0C  Easy and failure-free installation using the mounting kit PR 6012  Mounting kit PR 6012 benefits   Integrated jack-up and dummy function  Low installation height\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/product\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Minebea intec \/ Load cell PR 6212, converter Connexx\u00ae for maximum corrosion resistance\" \/>\n<meta property=\"og:description\" content=\"Load cell PR 6212 benefits   Maximum corrosion resistance  High-temperature version available for up to 180 \u00b0C  Easy and failure-free installation using the mounting kit PR 6012  Mounting kit PR 6012 benefits   Integrated jack-up and dummy function  Low installation height\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/product\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/csm_load-cells-pr-6212_03c313ec50.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"550\" \/>\n\t<meta property=\"og:image:height\" content=\"301\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"10 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\\\/\",\"name\":\"Minebea intec \\\/ Load cell PR 6212, converter Connexx\u00ae for maximum corrosion resistance - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/csm_load-cells-pr-6212_03c313ec50.webp\",\"datePublished\":\"2026-01-22T03:01:20+00:00\",\"description\":\"Load cell PR 6212 benefits Maximum corrosion resistance High-temperature version available for up to 180 \u00b0C Easy and failure-free installation using the mounting kit PR 6012 Mounting kit PR 6012 benefits Integrated jack-up and dummy function Low installation height\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/csm_load-cells-pr-6212_03c313ec50.webp\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/csm_load-cells-pr-6212_03c313ec50.webp\",\"width\":550,\"height\":301},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Minebea intec \\\/ Load cell PR 6212, converter Connexx\u00ae for maximum corrosion resistance\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/product\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Minebea intec \/ Load cell PR 6212, converter Connexx\u00ae for maximum corrosion resistance - CAS Scale Korea Co., Ltd.","description":"Load cell PR 6212 benefits   Maximum corrosion resistance  High-temperature version available for up to 180 \u00b0C  Easy and failure-free installation using the mounting kit PR 6012  Mounting kit PR 6012 benefits   Integrated jack-up and dummy function  Low installation height","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/product\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\/","og_locale":"en_US","og_type":"article","og_title":"Minebea intec \/ Load cell PR 6212, converter Connexx\u00ae for maximum corrosion resistance","og_description":"Load cell PR 6212 benefits   Maximum corrosion resistance  High-temperature version available for up to 180 \u00b0C  Easy and failure-free installation using the mounting kit PR 6012  Mounting kit PR 6012 benefits   Integrated jack-up and dummy function  Low installation height","og_url":"https:\/\/casscale.net\/en\/product\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\/","og_site_name":"CAS Scale Korea Co., Ltd.","og_image":[{"width":550,"height":301,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/csm_load-cells-pr-6212_03c313ec50.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"10 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/product\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\/","url":"https:\/\/casscale.net\/en\/product\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\/","name":"Minebea intec \/ Load cell PR 6212, converter Connexx\u00ae for maximum corrosion resistance - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/product\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/product\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/csm_load-cells-pr-6212_03c313ec50.webp","datePublished":"2026-01-22T03:01:20+00:00","description":"Load cell PR 6212 benefits Maximum corrosion resistance High-temperature version available for up to 180 \u00b0C Easy and failure-free installation using the mounting kit PR 6012 Mounting kit PR 6012 benefits Integrated jack-up and dummy function Low installation height","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/product\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/product\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/product\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/csm_load-cells-pr-6212_03c313ec50.webp","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/csm_load-cells-pr-6212_03c313ec50.webp","width":550,"height":301},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/product\/minebea-intec-load-cell-pr-6212-converter-connexx-for-maximum-corrosion-resistance\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/en\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"Minebea intec \/ Load cell PR 6212, converter Connexx\u00ae for maximum corrosion resistance"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/product\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/287261","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=287261"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/287236"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=287261"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=287261"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=287261"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=287261"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}