{"id":287426,"date":"2026-01-23T17:41:45","date_gmt":"2026-01-23T08:41:45","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\/"},"modified":"2026-01-23T17:51:19","modified_gmt":"2026-01-23T08:51:19","slug":"hardy-hi-sp1-and-hi-sp6-single-point-load-sensors","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\/","title":{"rendered":"HARDY \/ HI SP1 and HI SP6 Single Point Load Sensors"},"content":{"rendered":"<h2>HISP1 &#8211; C2\u00ae Stainless Steel Single Point Load Cell (7.5 kg &#8211; 200 kg)<\/h2>\n<p>Hardy\u2019s ADVANTAGE\u00ae Single Point Load Cells are designed to provide exceptional performance in a safe and predictable manner. Predominantly used in packing and OEM applications, this line of precision load cells comes with quick, easy, and accurate C2\u00ae electronic calibration.<br \/>\nThey are also ideal for bench scales, which require a low sensitivity to off center loads. They are built to perform in the harsh environments found in the food, chemical, and allied industries.<br \/>\nThe sensors are 17-4 PH stainless steel with C2\u00ae calibration capabilities and come with three meters (9-10 ft) of cable.<br \/>\nThe HI SP1 is available in capacities from 7.5kg to 200kg (16.5 to 440lbs). Each is environmentally protected with a plastic covering to IP67 (IP65 for 7.5 and 10kg) and has an integral mounting spacer.<br \/>\n<strong>Specifications<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td>SPECIFICATIONS<\/td>\n<td>HI SP1<\/td>\n<\/tr>\n<tr>\n<td>Capacity lbs<\/td>\n<td>16.5\/22\/33\/66\/110\/165\/220\/440<\/td>\n<\/tr>\n<tr>\n<td>Capacity kg<\/td>\n<td>7.5\/10\/15\/30\/50\/75\/100\/200<\/td>\n<\/tr>\n<tr>\n<td>Rated Output (ES)<\/td>\n<td>2\u00b10.10mV\/V<\/td>\n<\/tr>\n<tr>\n<td>Non-Linearity<\/td>\n<td>&lt;\u00b10.0166 % R.O.<\/td>\n<\/tr>\n<tr>\n<td>Hysteresis<\/td>\n<td>&lt;\u00b10.0166 % R.O.<\/td>\n<\/tr>\n<tr>\n<td>Zero Balance<\/td>\n<td>&lt;\u00b15.0 % R.O.<\/td>\n<\/tr>\n<tr>\n<td>Combined Error<\/td>\n<td>&lt;\u00b10.02 % R.O.<\/td>\n<\/tr>\n<tr>\n<td>Creep @ 30 Min.<\/td>\n<td>&lt;\u00b10.0166 % R.O.<\/td>\n<\/tr>\n<tr>\n<td>Temp Effect Output<\/td>\n<td>&lt;\u00b10.0140 % R.O.\/C<\/td>\n<\/tr>\n<tr>\n<td>Temp Effect Sensitivity<\/td>\n<td>&lt;\u00b10.010 % R.O.\/C<\/td>\n<\/tr>\n<tr>\n<td>Input Resistance<\/td>\n<td>390 \u00b1 20 ohm<\/td>\n<\/tr>\n<tr>\n<td>Output Resistance<\/td>\n<td>330 \u00b1 25 ohm<\/td>\n<\/tr>\n<tr>\n<td>Insulation Resistance<\/td>\n<td>\u22655000 Mohm<\/td>\n<\/tr>\n<tr>\n<td>Excitation<\/td>\n<td>5 &#8211; 15 vdc<\/td>\n<\/tr>\n<tr>\n<td>Safe Load Limit<\/td>\n<td>200 % Emax<\/td>\n<\/tr>\n<tr>\n<td>Ultimate Load<\/td>\n<td>300 % Emax<\/td>\n<\/tr>\n<tr>\n<td>Safe Side Load<\/td>\n<td>100 % Emax<\/td>\n<\/tr>\n<tr>\n<td>Hazardous<\/td>\n<td>FM IS, Class1, Div 1<\/td>\n<\/tr>\n<tr>\n<td>IP Rating<\/td>\n<td>IP67 (IP65 for 7.5 &amp; 10 KG)<\/td>\n<\/tr>\n<tr>\n<td>Warranty<\/td>\n<td>Two years<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>ORDERING INFORMATION<\/strong><br \/>\nNo mounting hardware. Shipping Wt. approx. 4 lbs. for HI SP6, 3 lbs. HI<br \/>\nSP1.<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"104\"><strong>Capacity<\/strong><\/td>\n<td width=\"83\"><strong>Model#<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"51\">lbs*<\/td>\n<td width=\"52\">kg<\/td>\n<td width=\"83\">Load Sensor<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">22<\/td>\n<td width=\"52\">10<\/td>\n<td width=\"83\">HI SP6-10<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">44<\/td>\n<td width=\"52\">20<\/td>\n<td width=\"83\">HI SP6-20<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">110<\/td>\n<td width=\"52\">50<\/td>\n<td width=\"83\">HI SP6-50<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">220<\/td>\n<td width=\"52\">100<\/td>\n<td width=\"83\">HI SP6-100<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">440<\/td>\n<td width=\"52\">200<\/td>\n<td width=\"83\">HI SP6-200<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"104\"><strong>Capacity<\/strong><\/td>\n<td width=\"83\"><strong>Model#<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"51\">lbs*<\/td>\n<td width=\"52\">kg<\/td>\n<td width=\"83\">Load Sensor<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">16.5<\/td>\n<td width=\"52\">7.5<\/td>\n<td width=\"83\">HI SP1-7.5<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">22<\/td>\n<td width=\"52\">10<\/td>\n<td width=\"83\">HI SP1-10<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">33<\/td>\n<td width=\"52\">15<\/td>\n<td width=\"83\">HI SP1-15<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">66<\/td>\n<td width=\"52\">30<\/td>\n<td width=\"83\">HI SP1-30<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">110<\/td>\n<td width=\"52\">50<\/td>\n<td width=\"83\">HI SP1-50<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">165<\/td>\n<td width=\"52\">75<\/td>\n<td width=\"83\">HI SP1-75<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">220<\/td>\n<td width=\"52\">100<\/td>\n<td width=\"83\">HI SP1-100<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">440<\/td>\n<td width=\"52\">200<\/td>\n<td width=\"83\">HI SP1-200<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>HI SP1 Single Point Outline<br \/>\n<img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-287422\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/HISP1-C2.png\" alt=\"\" width=\"1711\" height=\"996\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/HISP1-C2.png 1711w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/HISP1-C2-687x400.png 687w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/HISP1-C2-1374x800.png 1374w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/HISP1-C2-768x447.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/HISP1-C2-1536x894.png 1536w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/HISP1-C2-600x349.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/HISP1-C2-64x37.png 64w\" sizes=\"(max-width: 1711px) 100vw, 1711px\" \/><br \/>\nHI SP6 Single Point Outline<br \/>\n<img decoding=\"async\" class=\"alignnone size-full wp-image-287424\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/HI-SP6-Single-Point-Outline.png\" alt=\"\" width=\"1291\" height=\"846\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/HI-SP6-Single-Point-Outline.png 1291w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/HI-SP6-Single-Point-Outline-610x400.png 610w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/HI-SP6-Single-Point-Outline-1221x800.png 1221w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/HI-SP6-Single-Point-Outline-768x503.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/HI-SP6-Single-Point-Outline-600x393.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/HI-SP6-Single-Point-Outline-64x42.png 64w\" sizes=\"(max-width: 1291px) 100vw, 1291px\" \/><br \/>\n\u00a0<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"83\">\u00a0<\/td>\n<td width=\"74\">HISP1<\/td>\n<td width=\"74\">HISP6<\/td>\n<\/tr>\n<tr>\n<td width=\"83\">EXCITATION +<\/td>\n<td width=\"74\">GREEN<\/td>\n<td width=\"74\">RED<\/td>\n<\/tr>\n<tr>\n<td width=\"83\">EXCITATION \u2013<\/td>\n<td width=\"74\">BLACK<\/td>\n<td width=\"74\">BLACK<\/td>\n<\/tr>\n<tr>\n<td width=\"83\">SIGNAL +<\/td>\n<td width=\"74\">WHITE<\/td>\n<td width=\"74\">GREEN<\/td>\n<\/tr>\n<tr>\n<td width=\"83\">SIGNAL \u2013<\/td>\n<td width=\"74\">RED<\/td>\n<td width=\"74\">WHITE<\/td>\n<\/tr>\n<tr>\n<td width=\"83\">C2+<\/td>\n<td width=\"74\">GRAY<\/td>\n<td width=\"74\">GRAY<\/td>\n<\/tr>\n<tr>\n<td width=\"83\">C2 \u2013<\/td>\n<td width=\"74\">VIOLET<\/td>\n<td width=\"74\">VIOLET<\/td>\n<\/tr>\n<tr>\n<td width=\"83\">SHIELD<\/td>\n<td width=\"74\">YELLOW<\/td>\n<td width=\"74\">YELLOW<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>WARNING: NEVER cut load sensor cable<br \/>\nCABLE LENGTH 9-10 FEET<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hardy\u2019s ADVANTAGE\u00ae Single Point Load Cells are designed to provide exceptional performance in a safe and predictable manner. Predominantly used in packing and OEM applications, this line of precision load cells comes with quick, easy, and accurate C2\u00ae electronic calibration. They are accurate load cells used for a wide range of applications.<\/p>\n","protected":false},"featured_media":287421,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5450],"product_cat":[3385],"product_tag":[4628],"class_list":{"0":"post-287426","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-hardy","7":"product_cat-single-point-en","8":"product_tag-single-point-load-cell-en","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>HARDY \/ HI SP1 and HI SP6 Single Point Load Sensors - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"Hardy\u2019s ADVANTAGE\u00ae Single Point Load Cells are designed to provide exceptional performance in a safe and predictable manner. Predominantly used in packing and OEM applications, this line of precision load cells comes with quick, easy, and accurate C2\u00ae electronic calibration. They are accurate load cells used for a wide range of applications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/product\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HARDY \/ HI SP1 and HI SP6 Single Point Load Sensors\" \/>\n<meta property=\"og:description\" content=\"Hardy\u2019s ADVANTAGE\u00ae Single Point Load Cells are designed to provide exceptional performance in a safe and predictable manner. Predominantly used in packing and OEM applications, this line of precision load cells comes with quick, easy, and accurate C2\u00ae electronic calibration. They are accurate load cells used for a wide range of applications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/product\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-23T08:51:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/0000167_HISP1.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"480\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\\\/\",\"name\":\"HARDY \\\/ HI SP1 and HI SP6 Single Point Load Sensors - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/0000167_HISP1.jpeg\",\"datePublished\":\"2026-01-23T08:41:45+00:00\",\"dateModified\":\"2026-01-23T08:51:19+00:00\",\"description\":\"Hardy\u2019s ADVANTAGE\u00ae Single Point Load Cells are designed to provide exceptional performance in a safe and predictable manner. Predominantly used in packing and OEM applications, this line of precision load cells comes with quick, easy, and accurate C2\u00ae electronic calibration. They are accurate load cells used for a wide range of applications.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/0000167_HISP1.jpeg\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/0000167_HISP1.jpeg\",\"width\":480,\"height\":480},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"HARDY \\\/ HI SP1 and HI SP6 Single Point Load Sensors\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/product\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"HARDY \/ HI SP1 and HI SP6 Single Point Load Sensors - CAS Scale Korea Co., Ltd.","description":"Hardy\u2019s ADVANTAGE\u00ae Single Point Load Cells are designed to provide exceptional performance in a safe and predictable manner. Predominantly used in packing and OEM applications, this line of precision load cells comes with quick, easy, and accurate C2\u00ae electronic calibration. They are accurate load cells used for a wide range of applications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/product\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\/","og_locale":"en_US","og_type":"article","og_title":"HARDY \/ HI SP1 and HI SP6 Single Point Load Sensors","og_description":"Hardy\u2019s ADVANTAGE\u00ae Single Point Load Cells are designed to provide exceptional performance in a safe and predictable manner. Predominantly used in packing and OEM applications, this line of precision load cells comes with quick, easy, and accurate C2\u00ae electronic calibration. They are accurate load cells used for a wide range of applications.","og_url":"https:\/\/casscale.net\/en\/product\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\/","og_site_name":"CAS Scale Korea Co., Ltd.","article_modified_time":"2026-01-23T08:51:19+00:00","og_image":[{"width":480,"height":480,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/0000167_HISP1.jpeg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/product\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\/","url":"https:\/\/casscale.net\/en\/product\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\/","name":"HARDY \/ HI SP1 and HI SP6 Single Point Load Sensors - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/product\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/product\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/0000167_HISP1.jpeg","datePublished":"2026-01-23T08:41:45+00:00","dateModified":"2026-01-23T08:51:19+00:00","description":"Hardy\u2019s ADVANTAGE\u00ae Single Point Load Cells are designed to provide exceptional performance in a safe and predictable manner. Predominantly used in packing and OEM applications, this line of precision load cells comes with quick, easy, and accurate C2\u00ae electronic calibration. They are accurate load cells used for a wide range of applications.","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/product\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/product\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/product\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/0000167_HISP1.jpeg","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/01\/0000167_HISP1.jpeg","width":480,"height":480},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/product\/hardy-hi-sp1-and-hi-sp6-single-point-load-sensors\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/en\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"HARDY \/ HI SP1 and HI SP6 Single Point Load Sensors"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/product\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/287426","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=287426"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/287421"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=287426"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=287426"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=287426"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=287426"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}