{"id":288568,"date":"2026-02-19T16:53:31","date_gmt":"2026-02-19T07:53:31","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/magtrol-zc-series-load-cells\/"},"modified":"2026-02-19T16:53:31","modified_gmt":"2026-02-19T07:53:31","slug":"magtrol-zc-series-load-cells","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/magtrol-zc-series-load-cells\/","title":{"rendered":"Magtrol \/ ZC Series \u2013 Load Cells"},"content":{"rendered":"<h4 class=\"product_title entry-title\">ZC Series \u2013 Load Cells<\/h4>\n<h6>Product Description<\/h6>\n<p><em><strong>Note: Not available in the US.<\/strong><\/em><\/p>\n<p>The load cells of the ZC series have been designed for application in platform scales in the classes C1 to C3 according to OIML-RI 60 for platform sizes up to 600The load cells of the ZC series have been designed for application in platform scales in the classes C1 to C3 according to OIML-RI 60 for platform sizes up to 600 mm \u00d7 600 mm. They are made entirely of high strength low-hysteresis aluminum alloy with its outstanding measuring properties. The sensing element itself is a well-proven configuration of parallel benders. Metal-foil strain gauges transform the elastic deformation of the sensing element into a truly proportional electrical signal, which can be processed by an electronic weighing unit. The strain gauges are under a heavy-duty cover plate to protect them against climatic influences. As a standard, the load cells are equipped with a 1.5 m connection cable (different lengths or 6-wire connection are optional). In addition to the nominal loads given in the specification, intermediate load values can be delivered. It is a matter of course that these load cells, after calibration in N, can also be supplied as high-precision force transducers up to the accuracy class 0.05%. Due to their single-point configuration, these cells are largely insensitive to the off-center introduction of force. The load cells may also be supplied with an integrated amplifier (model ZC-E). Their electrical output can be chosen as either (0 to 10) V or (4 to 20) mA.<\/p>\n<h6>Features<\/h6>\n<ul>\n<li>5 kg to 1000 kg (50 N to 10 kN)<\/li>\n<li>Single-point-load-cells<\/li>\n<li>High-accuracy (classification according to OIML-RI 60)<\/li>\n<li>Very easy assembly<\/li>\n<li>Made of high-strength aluminum alloy<\/li>\n<li>Enclosure protection IP 42<\/li>\n<\/ul>\n<h6>Specifications<\/h6>\n<table id=\"tablepress-224-no-2\" class=\"tablepress tablepress-id-224\">\n<thead>\n<tr class=\"row-1 odd\">\n<th class=\"column-1\">ACCURACY CLASS<\/th>\n<th class=\"column-2\">\u00a0<\/th>\n<th class=\"column-3\">0.1<\/th>\n<th class=\"column-4\">0.05<\/th>\n<th class=\"column-5\">C1<\/th>\n<th class=\"column-6\">C2<\/th>\n<th class=\"column-7\">C3<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n<td class=\"column-1\">Nominal force (=F,<sub>N<\/sub>)<\/td>\n<td class=\"column-2\">kN<\/td>\n<td class=\"column-3\" colspan=\"2\">0.05\/0.1\/0.2\/0.5 1\/2\/5\/10<\/td>\n<td class=\"column-5\">\u00a0<\/td>\n<td class=\"column-6\">\u00a0<\/td>\n<td class=\"column-7\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n<td class=\"column-1\">Nominal load (=F<sub>N<\/sub>)<\/td>\n<td class=\"column-2\">kg<\/td>\n<td class=\"column-3\">\u00a0<\/td>\n<td class=\"column-4\">\u00a0<\/td>\n<td class=\"column-5\" colspan=\"3\">5\/10\/20\/50 1000 100\/200\/500<\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n<td class=\"column-1\">Max. permissible force\/load<\/td>\n<td class=\"column-2\">%F<sub>N<\/sub><\/td>\n<td class=\"column-3\" colspan=\"5\">150<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n<td class=\"column-1\">Ultimate overload<\/td>\n<td class=\"column-2\">%F<sub>N<\/sub><\/td>\n<td class=\"column-3\" colspan=\"5\">&gt;300<\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n<td class=\"column-1\">Max. transverse force\/load<\/td>\n<td class=\"column-2\">%F<sub>N<\/sub><\/td>\n<td class=\"column-3\" colspan=\"5\">100<\/td>\n<\/tr>\n<tr class=\"row-7 odd\">\n<td class=\"column-1\">Minimum application range<\/td>\n<td class=\"column-2\">%F<sub>N<\/sub><\/td>\n<td class=\"column-3\">\u00a0<\/td>\n<td class=\"column-4\" colspan=\"2\">\u00a0<\/td>\n<td class=\"column-6\" colspan=\"2\">25<\/td>\n<\/tr>\n<tr class=\"row-8 even\">\n<td class=\"column-1\" colspan=\"7\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-9 odd\">\n<td class=\"column-1\">Reference temperature<\/td>\n<td class=\"column-2\">\u00b0C<\/td>\n<td class=\"column-3\" colspan=\"4\">+23<\/td>\n<td class=\"column-7\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-10 even\">\n<td class=\"column-1\">Nominal temperature range<\/td>\n<td class=\"column-2\">\u00b0C<\/td>\n<td class=\"column-3\" colspan=\"2\">-20 to +60<\/td>\n<td class=\"column-5\" colspan=\"3\">-10 to +40<\/td>\n<\/tr>\n<tr class=\"row-11 odd\">\n<td class=\"column-1\">Operating temperature range<\/td>\n<td class=\"column-2\">\u00b0C<\/td>\n<td class=\"column-3\" colspan=\"5\">-30 to +70<\/td>\n<\/tr>\n<tr class=\"row-12 even\">\n<td class=\"column-1\">Storage temperature range<\/td>\n<td class=\"column-2\">\u00b0C<\/td>\n<td class=\"column-3\" colspan=\"5\">-40 to +70<\/td>\n<\/tr>\n<tr class=\"row-13 odd\">\n<td class=\"column-1\">Enclosure protection (DIN 40050)<\/td>\n<td class=\"column-2\">\u00a0<\/td>\n<td class=\"column-3\" colspan=\"5\">IP 42<\/td>\n<\/tr>\n<tr class=\"row-14 even\">\n<td class=\"column-1\" colspan=\"7\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-15 odd\">\n<td class=\"column-1\">Nominal sensitivity (=S)<\/td>\n<td class=\"column-2\">mV\/V<\/td>\n<td class=\"column-3\" colspan=\"2\">2.000 \u00b10.002<\/td>\n<td class=\"column-5\" colspan=\"3\">2.0 \u00b10.2<\/td>\n<\/tr>\n<tr class=\"row-16 even\">\n<td class=\"column-1\">Zero tolerance band<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\" colspan=\"5\">\u22641<\/td>\n<\/tr>\n<tr class=\"row-17 odd\">\n<td class=\"column-1\">Max. supply voltage<\/td>\n<td class=\"column-2\">V<\/td>\n<td class=\"column-3\" colspan=\"5\">12<\/td>\n<\/tr>\n<tr class=\"row-18 even\">\n<td class=\"column-1\">Input resistance<\/td>\n<td class=\"column-2\">\u03a9<\/td>\n<td class=\"column-3\" colspan=\"5\">410 \u00b130<\/td>\n<\/tr>\n<tr class=\"row-19 odd\">\n<td class=\"column-1\">Output resistance<\/td>\n<td class=\"column-2\">\u03a9<\/td>\n<td class=\"column-3\" colspan=\"5\">352 \u00b11.5<\/td>\n<\/tr>\n<tr class=\"row-20 even\">\n<td class=\"column-1\">Insulation resistance<\/td>\n<td class=\"column-2\">\u03a9<\/td>\n<td class=\"column-3\" colspan=\"5\">&gt;5 \u00d7 10<sup>9<\/sup><\/td>\n<\/tr>\n<tr class=\"row-21 odd\">\n<td class=\"column-1\" colspan=\"7\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-22 even\">\n<td class=\"column-1\">Combined error\u00a0<sup>a)<\/sup><\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u00a0<\/td>\n<td class=\"column-4\">\u00a0<\/td>\n<td class=\"column-5\">\u22640.030<\/td>\n<td class=\"column-6\">\u22640.023<\/td>\n<td class=\"column-7\">\u22640.021<\/td>\n<\/tr>\n<tr class=\"row-23 odd\">\n<td class=\"column-1\">Variability\u00a0<sup>b)<\/sup><\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u00a0<\/td>\n<td class=\"column-4\">\u00a0<\/td>\n<td class=\"column-5\">\u22640.030<\/td>\n<td class=\"column-6\">\u22640.010<\/td>\n<td class=\"column-7\">\u22640.010<\/td>\n<\/tr>\n<tr class=\"row-24 even\">\n<td class=\"column-1\">Linearity error\u00a0<sup>b)<\/sup><\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u22640.1<\/td>\n<td class=\"column-4\">\u22640.05<\/td>\n<td class=\"column-5\">\u00a0<\/td>\n<td class=\"column-6\">\u00a0<\/td>\n<td class=\"column-7\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-25 odd\">\n<td class=\"column-1\">Width of backlash<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u22640.1<\/td>\n<td class=\"column-4\">\u22640.05<\/td>\n<td class=\"column-5\">\u00a0<\/td>\n<td class=\"column-6\">\u00a0<\/td>\n<td class=\"column-7\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-26 even\">\n<td class=\"column-1\">TC of zero per 10 K<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u22640.05<\/td>\n<td class=\"column-4\">\u22640.025<\/td>\n<td class=\"column-5\">\u22640.025<\/td>\n<td class=\"column-6\">\u22640.012<\/td>\n<td class=\"column-7\">\u22640.008<\/td>\n<\/tr>\n<tr class=\"row-27 odd\">\n<td class=\"column-1\">TC of sensitivity per 10 K<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u22640.1<\/td>\n<td class=\"column-4\">\u22640.05<\/td>\n<td class=\"column-5\">\u22640.017<\/td>\n<td class=\"column-6\">\u22640.010<\/td>\n<td class=\"column-7\">\u22640.008<\/td>\n<\/tr>\n<tr class=\"row-28 even\">\n<td class=\"column-1\">Zero recovery error (30 min)<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u22640.1<\/td>\n<td class=\"column-4\">\u22640.05<\/td>\n<td class=\"column-5\">\u22640.050<\/td>\n<td class=\"column-6\">\u22640.025<\/td>\n<td class=\"column-7\">\u22640.017<\/td>\n<\/tr>\n<tr class=\"row-29 odd\">\n<td class=\"column-1\">Creepage error (30 min)<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u22640.1<\/td>\n<td class=\"column-4\">\u22640.05<\/td>\n<td class=\"column-5\">\u22640.049<\/td>\n<td class=\"column-6\">\u22640.024<\/td>\n<td class=\"column-7\">\u22640.024<\/td>\n<\/tr>\n<tr class=\"row-30 even\">\n<td class=\"column-1\">Off-centre load error according to OIML R76<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u00a0<\/td>\n<td class=\"column-4\">\u00a0<\/td>\n<td class=\"column-5\">\u22640.06<\/td>\n<td class=\"column-6\">\u22640.03<\/td>\n<td class=\"column-7\">\u22640.02<\/td>\n<\/tr>\n<tr class=\"row-31 odd\">\n<td class=\"column-1\">Platform size<\/td>\n<td class=\"column-2\">mm<\/td>\n<td class=\"column-3\">\u00a0<\/td>\n<td class=\"column-4\">\u00a0<\/td>\n<td class=\"column-5\" colspan=\"3\">400\u00d7400 Configuration 1<br \/>\n600\u00d7600 Configuration 2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>a) According to VDE \/ VDI 2637<br \/>\nb) According to VDE \/ VDI 2638<\/p>\n<p><strong>Option :<\/strong>\u00a0The transducers can be delivered with an internal amplifier delivering an output signal of 0(4) \u2013 20 mA or 0 \u2013 10 V within precision classes 0.2 and 0.5.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>ZC Series \u2013 Load Cells Product Description Note: Not available in the US. The load cells of the ZC series have been designed for application in platform scales in the classes C1 to C3 according to OIML-RI 60 for platform sizes up to 600The load cells of the ZC series have been designed for application [&hellip;]<\/p>\n","protected":false},"featured_media":288567,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5477],"product_cat":[3448],"product_tag":[5030],"class_list":{"0":"post-288568","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-magtrol","7":"product_cat-force-sensor","8":"product_tag-force-sensor-en2","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/288568","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=288568"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/288567"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=288568"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=288568"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=288568"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=288568"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}