{"id":288568,"date":"2026-02-19T16:53:31","date_gmt":"2026-02-19T07:53:31","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/magtrol-zc-series-load-cells\/"},"modified":"2026-02-19T16:53:31","modified_gmt":"2026-02-19T07:53:31","slug":"magtrol-zc-series-load-cells","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/magtrol-zc-series-load-cells\/","title":{"rendered":"Magtrol \/ ZC Series \u2013 Load Cells"},"content":{"rendered":"<h4 class=\"product_title entry-title\">ZC Series \u2013 Load Cells<\/h4>\n<h6>Product Description<\/h6>\n<p><em><strong>Note: Not available in the US.<\/strong><\/em><\/p>\n<p>The load cells of the ZC series have been designed for application in platform scales in the classes C1 to C3 according to OIML-RI 60 for platform sizes up to 600The load cells of the ZC series have been designed for application in platform scales in the classes C1 to C3 according to OIML-RI 60 for platform sizes up to 600 mm \u00d7 600 mm. They are made entirely of high strength low-hysteresis aluminum alloy with its outstanding measuring properties. The sensing element itself is a well-proven configuration of parallel benders. Metal-foil strain gauges transform the elastic deformation of the sensing element into a truly proportional electrical signal, which can be processed by an electronic weighing unit. The strain gauges are under a heavy-duty cover plate to protect them against climatic influences. As a standard, the load cells are equipped with a 1.5 m connection cable (different lengths or 6-wire connection are optional). In addition to the nominal loads given in the specification, intermediate load values can be delivered. It is a matter of course that these load cells, after calibration in N, can also be supplied as high-precision force transducers up to the accuracy class 0.05%. Due to their single-point configuration, these cells are largely insensitive to the off-center introduction of force. The load cells may also be supplied with an integrated amplifier (model ZC-E). Their electrical output can be chosen as either (0 to 10) V or (4 to 20) mA.<\/p>\n<h6>Features<\/h6>\n<ul>\n<li>5 kg to 1000 kg (50 N to 10 kN)<\/li>\n<li>Single-point-load-cells<\/li>\n<li>High-accuracy (classification according to OIML-RI 60)<\/li>\n<li>Very easy assembly<\/li>\n<li>Made of high-strength aluminum alloy<\/li>\n<li>Enclosure protection IP 42<\/li>\n<\/ul>\n<h6>Specifications<\/h6>\n<table id=\"tablepress-224-no-2\" class=\"tablepress tablepress-id-224\">\n<thead>\n<tr class=\"row-1 odd\">\n<th class=\"column-1\">ACCURACY CLASS<\/th>\n<th class=\"column-2\">\u00a0<\/th>\n<th class=\"column-3\">0.1<\/th>\n<th class=\"column-4\">0.05<\/th>\n<th class=\"column-5\">C1<\/th>\n<th class=\"column-6\">C2<\/th>\n<th class=\"column-7\">C3<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n<td class=\"column-1\">Nominal force (=F,<sub>N<\/sub>)<\/td>\n<td class=\"column-2\">kN<\/td>\n<td class=\"column-3\" colspan=\"2\">0.05\/0.1\/0.2\/0.5 1\/2\/5\/10<\/td>\n<td class=\"column-5\">\u00a0<\/td>\n<td class=\"column-6\">\u00a0<\/td>\n<td class=\"column-7\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n<td class=\"column-1\">Nominal load (=F<sub>N<\/sub>)<\/td>\n<td class=\"column-2\">kg<\/td>\n<td class=\"column-3\">\u00a0<\/td>\n<td class=\"column-4\">\u00a0<\/td>\n<td class=\"column-5\" colspan=\"3\">5\/10\/20\/50 1000 100\/200\/500<\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n<td class=\"column-1\">Max. permissible force\/load<\/td>\n<td class=\"column-2\">%F<sub>N<\/sub><\/td>\n<td class=\"column-3\" colspan=\"5\">150<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n<td class=\"column-1\">Ultimate overload<\/td>\n<td class=\"column-2\">%F<sub>N<\/sub><\/td>\n<td class=\"column-3\" colspan=\"5\">&gt;300<\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n<td class=\"column-1\">Max. transverse force\/load<\/td>\n<td class=\"column-2\">%F<sub>N<\/sub><\/td>\n<td class=\"column-3\" colspan=\"5\">100<\/td>\n<\/tr>\n<tr class=\"row-7 odd\">\n<td class=\"column-1\">Minimum application range<\/td>\n<td class=\"column-2\">%F<sub>N<\/sub><\/td>\n<td class=\"column-3\">\u00a0<\/td>\n<td class=\"column-4\" colspan=\"2\">\u00a0<\/td>\n<td class=\"column-6\" colspan=\"2\">25<\/td>\n<\/tr>\n<tr class=\"row-8 even\">\n<td class=\"column-1\" colspan=\"7\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-9 odd\">\n<td class=\"column-1\">Reference temperature<\/td>\n<td class=\"column-2\">\u00b0C<\/td>\n<td class=\"column-3\" colspan=\"4\">+23<\/td>\n<td class=\"column-7\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-10 even\">\n<td class=\"column-1\">Nominal temperature range<\/td>\n<td class=\"column-2\">\u00b0C<\/td>\n<td class=\"column-3\" colspan=\"2\">-20 to +60<\/td>\n<td class=\"column-5\" colspan=\"3\">-10 to +40<\/td>\n<\/tr>\n<tr class=\"row-11 odd\">\n<td class=\"column-1\">Operating temperature range<\/td>\n<td class=\"column-2\">\u00b0C<\/td>\n<td class=\"column-3\" colspan=\"5\">-30 to +70<\/td>\n<\/tr>\n<tr class=\"row-12 even\">\n<td class=\"column-1\">Storage temperature range<\/td>\n<td class=\"column-2\">\u00b0C<\/td>\n<td class=\"column-3\" colspan=\"5\">-40 to +70<\/td>\n<\/tr>\n<tr class=\"row-13 odd\">\n<td class=\"column-1\">Enclosure protection (DIN 40050)<\/td>\n<td class=\"column-2\">\u00a0<\/td>\n<td class=\"column-3\" colspan=\"5\">IP 42<\/td>\n<\/tr>\n<tr class=\"row-14 even\">\n<td class=\"column-1\" colspan=\"7\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-15 odd\">\n<td class=\"column-1\">Nominal sensitivity (=S)<\/td>\n<td class=\"column-2\">mV\/V<\/td>\n<td class=\"column-3\" colspan=\"2\">2.000 \u00b10.002<\/td>\n<td class=\"column-5\" colspan=\"3\">2.0 \u00b10.2<\/td>\n<\/tr>\n<tr class=\"row-16 even\">\n<td class=\"column-1\">Zero tolerance band<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\" colspan=\"5\">\u22641<\/td>\n<\/tr>\n<tr class=\"row-17 odd\">\n<td class=\"column-1\">Max. supply voltage<\/td>\n<td class=\"column-2\">V<\/td>\n<td class=\"column-3\" colspan=\"5\">12<\/td>\n<\/tr>\n<tr class=\"row-18 even\">\n<td class=\"column-1\">Input resistance<\/td>\n<td class=\"column-2\">\u03a9<\/td>\n<td class=\"column-3\" colspan=\"5\">410 \u00b130<\/td>\n<\/tr>\n<tr class=\"row-19 odd\">\n<td class=\"column-1\">Output resistance<\/td>\n<td class=\"column-2\">\u03a9<\/td>\n<td class=\"column-3\" colspan=\"5\">352 \u00b11.5<\/td>\n<\/tr>\n<tr class=\"row-20 even\">\n<td class=\"column-1\">Insulation resistance<\/td>\n<td class=\"column-2\">\u03a9<\/td>\n<td class=\"column-3\" colspan=\"5\">&gt;5 \u00d7 10<sup>9<\/sup><\/td>\n<\/tr>\n<tr class=\"row-21 odd\">\n<td class=\"column-1\" colspan=\"7\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-22 even\">\n<td class=\"column-1\">Combined error\u00a0<sup>a)<\/sup><\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u00a0<\/td>\n<td class=\"column-4\">\u00a0<\/td>\n<td class=\"column-5\">\u22640.030<\/td>\n<td class=\"column-6\">\u22640.023<\/td>\n<td class=\"column-7\">\u22640.021<\/td>\n<\/tr>\n<tr class=\"row-23 odd\">\n<td class=\"column-1\">Variability\u00a0<sup>b)<\/sup><\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u00a0<\/td>\n<td class=\"column-4\">\u00a0<\/td>\n<td class=\"column-5\">\u22640.030<\/td>\n<td class=\"column-6\">\u22640.010<\/td>\n<td class=\"column-7\">\u22640.010<\/td>\n<\/tr>\n<tr class=\"row-24 even\">\n<td class=\"column-1\">Linearity error\u00a0<sup>b)<\/sup><\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u22640.1<\/td>\n<td class=\"column-4\">\u22640.05<\/td>\n<td class=\"column-5\">\u00a0<\/td>\n<td class=\"column-6\">\u00a0<\/td>\n<td class=\"column-7\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-25 odd\">\n<td class=\"column-1\">Width of backlash<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u22640.1<\/td>\n<td class=\"column-4\">\u22640.05<\/td>\n<td class=\"column-5\">\u00a0<\/td>\n<td class=\"column-6\">\u00a0<\/td>\n<td class=\"column-7\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-26 even\">\n<td class=\"column-1\">TC of zero per 10 K<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u22640.05<\/td>\n<td class=\"column-4\">\u22640.025<\/td>\n<td class=\"column-5\">\u22640.025<\/td>\n<td class=\"column-6\">\u22640.012<\/td>\n<td class=\"column-7\">\u22640.008<\/td>\n<\/tr>\n<tr class=\"row-27 odd\">\n<td class=\"column-1\">TC of sensitivity per 10 K<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u22640.1<\/td>\n<td class=\"column-4\">\u22640.05<\/td>\n<td class=\"column-5\">\u22640.017<\/td>\n<td class=\"column-6\">\u22640.010<\/td>\n<td class=\"column-7\">\u22640.008<\/td>\n<\/tr>\n<tr class=\"row-28 even\">\n<td class=\"column-1\">Zero recovery error (30 min)<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u22640.1<\/td>\n<td class=\"column-4\">\u22640.05<\/td>\n<td class=\"column-5\">\u22640.050<\/td>\n<td class=\"column-6\">\u22640.025<\/td>\n<td class=\"column-7\">\u22640.017<\/td>\n<\/tr>\n<tr class=\"row-29 odd\">\n<td class=\"column-1\">Creepage error (30 min)<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u22640.1<\/td>\n<td class=\"column-4\">\u22640.05<\/td>\n<td class=\"column-5\">\u22640.049<\/td>\n<td class=\"column-6\">\u22640.024<\/td>\n<td class=\"column-7\">\u22640.024<\/td>\n<\/tr>\n<tr class=\"row-30 even\">\n<td class=\"column-1\">Off-centre load error according to OIML R76<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">\u00a0<\/td>\n<td class=\"column-4\">\u00a0<\/td>\n<td class=\"column-5\">\u22640.06<\/td>\n<td class=\"column-6\">\u22640.03<\/td>\n<td class=\"column-7\">\u22640.02<\/td>\n<\/tr>\n<tr class=\"row-31 odd\">\n<td class=\"column-1\">Platform size<\/td>\n<td class=\"column-2\">mm<\/td>\n<td class=\"column-3\">\u00a0<\/td>\n<td class=\"column-4\">\u00a0<\/td>\n<td class=\"column-5\" colspan=\"3\">400\u00d7400 Configuration 1<br \/>\n600\u00d7600 Configuration 2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>a) According to VDE \/ VDI 2637<br \/>\nb) According to VDE \/ VDI 2638<\/p>\n<p><strong>Option :<\/strong>\u00a0The transducers can be delivered with an internal amplifier delivering an output signal of 0(4) \u2013 20 mA or 0 \u2013 10 V within precision classes 0.2 and 0.5.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>ZC Series \u2013 Load Cells Product Description Note: Not available in the US. The load cells of the ZC series have been designed for application in platform scales in the classes C1 to C3 according to OIML-RI 60 for platform sizes up to 600The load cells of the ZC series have been designed for application [&hellip;]<\/p>\n","protected":false},"featured_media":288567,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5477],"product_cat":[3448],"product_tag":[5030],"class_list":{"0":"post-288568","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-magtrol","7":"product_cat-force-sensor","8":"product_tag-force-sensor-en2","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Magtrol \/ ZC Series \u2013 Load Cells - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"ZC Series \u2013 Load Cells Product Description Note: Not available in the US. The load cells of the ZC series have been designed for application in platform\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/product\/magtrol-zc-series-load-cells\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Magtrol \/ ZC Series \u2013 Load Cells\" \/>\n<meta property=\"og:description\" content=\"ZC Series \u2013 Load Cells Product Description Note: Not available in the US. The load cells of the ZC series have been designed for application in platform\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/product\/magtrol-zc-series-load-cells\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/zc.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"854\" \/>\n\t<meta property=\"og:image:height\" content=\"856\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zc-series-load-cells\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zc-series-load-cells\\\/\",\"name\":\"Magtrol \\\/ ZC Series \u2013 Load Cells - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zc-series-load-cells\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zc-series-load-cells\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/zc.jpg\",\"datePublished\":\"2026-02-19T07:53:31+00:00\",\"description\":\"ZC Series \u2013 Load Cells Product Description Note: Not available in the US. The load cells of the ZC series have been designed for application in platform\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zc-series-load-cells\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zc-series-load-cells\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zc-series-load-cells\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/zc.jpg\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/zc.jpg\",\"width\":854,\"height\":856},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zc-series-load-cells\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Magtrol \\\/ ZC Series \u2013 Load Cells\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/product\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Magtrol \/ ZC Series \u2013 Load Cells - CAS Scale Korea Co., Ltd.","description":"ZC Series \u2013 Load Cells Product Description Note: Not available in the US. The load cells of the ZC series have been designed for application in platform","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/product\/magtrol-zc-series-load-cells\/","og_locale":"en_US","og_type":"article","og_title":"Magtrol \/ ZC Series \u2013 Load Cells","og_description":"ZC Series \u2013 Load Cells Product Description Note: Not available in the US. The load cells of the ZC series have been designed for application in platform","og_url":"https:\/\/casscale.net\/en\/product\/magtrol-zc-series-load-cells\/","og_site_name":"CAS Scale Korea Co., Ltd.","og_image":[{"width":854,"height":856,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/zc.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/product\/magtrol-zc-series-load-cells\/","url":"https:\/\/casscale.net\/en\/product\/magtrol-zc-series-load-cells\/","name":"Magtrol \/ ZC Series \u2013 Load Cells - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/product\/magtrol-zc-series-load-cells\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/product\/magtrol-zc-series-load-cells\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/zc.jpg","datePublished":"2026-02-19T07:53:31+00:00","description":"ZC Series \u2013 Load Cells Product Description Note: Not available in the US. The load cells of the ZC series have been designed for application in platform","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/product\/magtrol-zc-series-load-cells\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/product\/magtrol-zc-series-load-cells\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/product\/magtrol-zc-series-load-cells\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/zc.jpg","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/zc.jpg","width":854,"height":856},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/product\/magtrol-zc-series-load-cells\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"Magtrol \/ ZC Series \u2013 Load Cells"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/product\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/288568","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=288568"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/288567"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=288568"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=288568"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=288568"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=288568"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}