{"id":288573,"date":"2026-02-19T17:40:45","date_gmt":"2026-02-19T08:40:45","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/magtrol-zf-series-and-zf-s-series-force-transducers\/"},"modified":"2026-02-19T17:40:45","modified_gmt":"2026-02-19T08:40:45","slug":"magtrol-zf-series-and-zf-s-series-force-transducers","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/magtrol-zf-series-and-zf-s-series-force-transducers\/","title":{"rendered":"Magtrol \/ ZF Series and ZF-S Series \u2013 Force Transducers"},"content":{"rendered":"<h4 class=\"product_title entry-title\">ZC Series \u2013 Load Cells<\/h4>\n<h6>Product Description<\/h6>\n<p><strong><em>*Not available in the US.<\/em><\/strong><\/p>\n<p>The force transducers of the ZF \/ ZF-S Series have been designed for the measurement of static and dynamic tensile and pressure forces; they are characterized by their low assembly height at a high measuring accuracy. The force is introduced on one side through a central tapped hole, the other side of the force transducer has to be fixed to a sufficiently rigid plane surface by means of 8 high-strength hexagonal socket-head bolts to be tightened with a defined torque. A strain gauge bridge converts the elastic deformation of the sensing element into an electrical signal that can be evaluated. Compensation and adjustment elements are used to set the required technical data. As a standard, the transducers are equipped with a 3 m connection cable, which has free ends on the other side.<\/p>\n<h6>Features<\/h6>\n<ul>\n<li>\n<p>ZF Series<\/p>\n<ul>\n<li>1 kN to 200 kN<\/li>\n<li>High accuracy<\/li>\n<li>For tensile or pressure forces<\/li>\n<li>Made of stainless steel<\/li>\n<li>Enclosure protection IP 67<\/li>\n<\/ul>\n<p>ZF-S Series<\/p>\n<ul>\n<li>100 N to 10 kN<\/li>\n<li>High precision<\/li>\n<li>Low assembly dimensions<\/li>\n<li>For tensile or pressure forces<\/li>\n<li>Enclosure protection IP 42<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h6>ZF Series Specifications<\/h6>\n<table id=\"tablepress-225-no-2\" class=\"tablepress tablepress-id-225\">\n<thead>\n<tr class=\"row-1 odd\">\n<th class=\"column-1\">ACCURACY CLASS<\/th>\n<th class=\"column-2\">\u00a0<\/th>\n<th class=\"column-3\">0.1<\/th>\n<th class=\"column-4\">0.2<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n<td class=\"column-1\">Nominal force (=F<sup>N<\/sup>)<\/td>\n<td class=\"column-2\">kN<\/td>\n<td class=\"column-3\">1\/2\/5\/10\/20\/50\/100<\/td>\n<td class=\"column-4\">200<\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n<td class=\"column-1\">Max. permissible force<\/td>\n<td class=\"column-2\">%F<sub>N<\/sub><\/td>\n<td class=\"column-3\" colspan=\"2\">150<\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n<td class=\"column-1\">Ultimate overload<\/td>\n<td class=\"column-2\">%F<sub>N<\/sub><\/td>\n<td class=\"column-3\" colspan=\"2\">&gt;500<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n<td class=\"column-1\">Max. transverse force<\/td>\n<td class=\"column-2\">%F<sub>N<\/sub><\/td>\n<td class=\"column-3\" colspan=\"2\">10<\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n<td class=\"column-1\" colspan=\"4\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-7 odd\">\n<td class=\"column-1\">Reference temperature<\/td>\n<td class=\"column-2\">\u00b0C<\/td>\n<td class=\"column-3\" colspan=\"2\">+23<\/td>\n<\/tr>\n<tr class=\"row-8 even\">\n<td class=\"column-1\">Nominal temperature range<\/td>\n<td class=\"column-2\">\u00b0C<\/td>\n<td class=\"column-3\" colspan=\"2\">-20 to +50<\/td>\n<\/tr>\n<tr class=\"row-9 odd\">\n<td class=\"column-1\">Storage temperature range<\/td>\n<td class=\"column-2\">\u00b0C<\/td>\n<td class=\"column-3\" colspan=\"2\">-30 to +70<\/td>\n<\/tr>\n<tr class=\"row-10 even\">\n<td class=\"column-1\">Enclosure protection (DIN 40050)<\/td>\n<td class=\"column-2\">\u00a0<\/td>\n<td class=\"column-3\" colspan=\"2\">IP 67<\/td>\n<\/tr>\n<tr class=\"row-11 odd\">\n<td class=\"column-1\" colspan=\"4\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-12 even\">\n<td class=\"column-1\">Nominal sensitivity (=S)<\/td>\n<td class=\"column-2\">mV\/V<\/td>\n<td class=\"column-3\" colspan=\"2\">2.000 \u00b10.005<\/td>\n<\/tr>\n<tr class=\"row-13 odd\">\n<td class=\"column-1\">Zero tolerance band<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\" colspan=\"2\">\u22643<\/td>\n<\/tr>\n<tr class=\"row-14 even\">\n<td class=\"column-1\">Max. supply voltage<\/td>\n<td class=\"column-2\">V<\/td>\n<td class=\"column-3\" colspan=\"2\">20<\/td>\n<\/tr>\n<tr class=\"row-15 odd\">\n<td class=\"column-1\">Input resistance<\/td>\n<td class=\"column-2\">\u03a9<\/td>\n<td class=\"column-3\" colspan=\"2\">770 \u00b140<\/td>\n<\/tr>\n<tr class=\"row-16 even\">\n<td class=\"column-1\">Output resistance<\/td>\n<td class=\"column-2\">\u03a9<\/td>\n<td class=\"column-3\" colspan=\"2\">700 \u00b110<\/td>\n<\/tr>\n<tr class=\"row-17 odd\">\n<td class=\"column-1\">Insulation resistance<\/td>\n<td class=\"column-2\">\u03a9<\/td>\n<td class=\"column-3\" colspan=\"2\">&gt;5 \u00d7 10<sup>9<\/sup><\/td>\n<\/tr>\n<tr class=\"row-18 even\">\n<td class=\"column-1\" colspan=\"4\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-19 odd\">\n<td class=\"column-1\">Combined error\u00a0<sup>a)<\/sup><\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">0.1<\/td>\n<td class=\"column-4\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-20 even\">\n<td class=\"column-1\">Linearity error<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">0.1<\/td>\n<td class=\"column-4\">0.2<\/td>\n<\/tr>\n<tr class=\"row-21 odd\">\n<td class=\"column-1\">Width of backlash<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">0.1<\/td>\n<td class=\"column-4\">0.2<\/td>\n<\/tr>\n<tr class=\"row-22 even\">\n<td class=\"column-1\">TC of zero per 10 K<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">0.1<\/td>\n<td class=\"column-4\">0.2<\/td>\n<\/tr>\n<tr class=\"row-23 odd\">\n<td class=\"column-1\">TC of sensitivity per 10 K<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">0.1<\/td>\n<td class=\"column-4\">0.2<\/td>\n<\/tr>\n<tr class=\"row-24 even\">\n<td class=\"column-1\">Creepage error (30 min)<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">0.1<\/td>\n<td class=\"column-4\">0.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>a) According to VDE \/ VDI 2638<\/p>\n<h6>ZF-S Series Specifications<\/h6>\n<table id=\"tablepress-226-no-2\" class=\"tablepress tablepress-id-226\">\n<thead>\n<tr class=\"row-1 odd\">\n<th class=\"column-1\">ACCURACY CLASS<\/th>\n<th class=\"column-2\">\u00a0<\/th>\n<th class=\"column-3\">0.2<\/th>\n<th class=\"column-4\">0.1<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n<td class=\"column-1\">Nominal force (=F<sub>N<\/sub>)<\/td>\n<td class=\"column-2\">kN<\/td>\n<td class=\"column-3\">0.1 \/ 0.2 \/ 0.5 \/ 1 \/ 2 \/ 5 \/ 10<\/td>\n<td class=\"column-4\">0.1 \/ 0.2 \/ 0.5 \/ 1 \/ 2<\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n<td class=\"column-1\">Max. permissible force<\/td>\n<td class=\"column-2\">%F<sub>N<\/sub><\/td>\n<td class=\"column-3\" colspan=\"2\">150<\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n<td class=\"column-1\">Ultimate overload<\/td>\n<td class=\"column-2\">%F<sub>N<\/sub><\/td>\n<td class=\"column-3\" colspan=\"2\">&gt;500<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n<td class=\"column-1\">Max. transverse force<\/td>\n<td class=\"column-2\">%F<sub>N<\/sub><\/td>\n<td class=\"column-3\" colspan=\"2\">10<\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n<td class=\"column-1\" colspan=\"4\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-7 odd\">\n<td class=\"column-1\">Reference temperature<\/td>\n<td class=\"column-2\">\u00b0C<\/td>\n<td class=\"column-3\" colspan=\"2\">+23<\/td>\n<\/tr>\n<tr class=\"row-8 even\">\n<td class=\"column-1\">Nominal temperature range<\/td>\n<td class=\"column-2\">\u00b0C<\/td>\n<td class=\"column-3\" colspan=\"2\">-20 to +50<\/td>\n<\/tr>\n<tr class=\"row-9 odd\">\n<td class=\"column-1\">Storage temperature range<\/td>\n<td class=\"column-2\">\u00b0C<\/td>\n<td class=\"column-3\" colspan=\"2\">-30 to +70<\/td>\n<\/tr>\n<tr class=\"row-10 even\">\n<td class=\"column-1\">Enclosure protection (DIN 40050)<\/td>\n<td class=\"column-2\">\u00a0<\/td>\n<td class=\"column-3\" colspan=\"2\">IP 42<\/td>\n<\/tr>\n<tr class=\"row-11 odd\">\n<td class=\"column-1\" colspan=\"4\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-12 even\">\n<td class=\"column-1\">Nominal sensitivity (=S)<\/td>\n<td class=\"column-2\">mV\/V<\/td>\n<td class=\"column-3\" colspan=\"2\">2.000 \u00b10.005<\/td>\n<\/tr>\n<tr class=\"row-13 odd\">\n<td class=\"column-1\">Zero tolerance band<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\" colspan=\"2\">\u22643<\/td>\n<\/tr>\n<tr class=\"row-14 even\">\n<td class=\"column-1\">Max. supply voltage<\/td>\n<td class=\"column-2\">V<\/td>\n<td class=\"column-3\" colspan=\"2\">10<\/td>\n<\/tr>\n<tr class=\"row-15 odd\">\n<td class=\"column-1\">Input resistance<\/td>\n<td class=\"column-2\">\u03a9<\/td>\n<td class=\"column-3\">380 \u00b130<\/td>\n<td class=\"column-4\">760 \u00b160<\/td>\n<\/tr>\n<tr class=\"row-16 even\">\n<td class=\"column-1\">Output resistance<\/td>\n<td class=\"column-2\">\u03a9<\/td>\n<td class=\"column-3\">352 \u00b13<\/td>\n<td class=\"column-4\">704 \u00b16<\/td>\n<\/tr>\n<tr class=\"row-17 odd\">\n<td class=\"column-1\">Insulation resistance<\/td>\n<td class=\"column-2\">\u03a9<\/td>\n<td class=\"column-3\" colspan=\"2\">&gt;5 \u00d7 10<sup>9<\/sup><\/td>\n<\/tr>\n<tr class=\"row-18 even\">\n<td class=\"column-1\" colspan=\"4\">\u00a0<\/td>\n<\/tr>\n<tr class=\"row-19 odd\">\n<td class=\"column-1\">Combined error\u00a0<sup>a)<\/sup><\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">0.2<\/td>\n<td class=\"column-4\">0.1<\/td>\n<\/tr>\n<tr class=\"row-20 even\">\n<td class=\"column-1\">Linearity error\u00a0<sup>a)<\/sup><\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">0.2<\/td>\n<td class=\"column-4\">0.1<\/td>\n<\/tr>\n<tr class=\"row-21 odd\">\n<td class=\"column-1\">Width of backlash\u00a0<sup>a)<\/sup><\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">0.2<\/td>\n<td class=\"column-4\">0.1<\/td>\n<\/tr>\n<tr class=\"row-22 even\">\n<td class=\"column-1\">TC of zero per 10 K<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">0.2<\/td>\n<td class=\"column-4\">0.1<\/td>\n<\/tr>\n<tr class=\"row-23 odd\">\n<td class=\"column-1\">TC of sensitivity per 10 K<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">0.2<\/td>\n<td class=\"column-4\">0.1<\/td>\n<\/tr>\n<tr class=\"row-24 even\">\n<td class=\"column-1\">Creepage error (30 min)<\/td>\n<td class=\"column-2\">%S<\/td>\n<td class=\"column-3\">0.2<\/td>\n<td class=\"column-4\">0.1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>a) According to VDI 2637<\/p>\n","protected":false},"excerpt":{"rendered":"<p>ZC Series \u2013 Load Cells Product Description *Not available in the US. The force transducers of the ZF \/ ZF-S Series have been designed for the measurement of static and dynamic tensile and pressure forces; they are characterized by their low assembly height at a high measuring accuracy. The force is introduced on one side [&hellip;]<\/p>\n","protected":false},"featured_media":288572,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5477],"product_cat":[3448],"product_tag":[5030],"class_list":{"0":"post-288573","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-magtrol","7":"product_cat-force-sensor","8":"product_tag-force-sensor-en2","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Magtrol \/ ZF Series and ZF-S Series \u2013 Force Transducers - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"ZC Series \u2013 Load Cells Product Description *Not available in the US. The force transducers of the ZF \/ ZF-S Series have been designed for the measurement\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/product\/magtrol-zf-series-and-zf-s-series-force-transducers\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Magtrol \/ ZF Series and ZF-S Series \u2013 Force Transducers\" \/>\n<meta property=\"og:description\" content=\"ZC Series \u2013 Load Cells Product Description *Not available in the US. The force transducers of the ZF \/ ZF-S Series have been designed for the measurement\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/product\/magtrol-zf-series-and-zf-s-series-force-transducers\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/zf-s.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"400\" \/>\n\t<meta property=\"og:image:height\" content=\"323\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zf-series-and-zf-s-series-force-transducers\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zf-series-and-zf-s-series-force-transducers\\\/\",\"name\":\"Magtrol \\\/ ZF Series and ZF-S Series \u2013 Force Transducers - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zf-series-and-zf-s-series-force-transducers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zf-series-and-zf-s-series-force-transducers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/zf-s.jpg\",\"datePublished\":\"2026-02-19T08:40:45+00:00\",\"description\":\"ZC Series \u2013 Load Cells Product Description *Not available in the US. The force transducers of the ZF \\\/ ZF-S Series have been designed for the measurement\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zf-series-and-zf-s-series-force-transducers\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zf-series-and-zf-s-series-force-transducers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zf-series-and-zf-s-series-force-transducers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/zf-s.jpg\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/zf-s.jpg\",\"width\":400,\"height\":323},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zf-series-and-zf-s-series-force-transducers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Magtrol \\\/ ZF Series and ZF-S Series \u2013 Force Transducers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/product\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Magtrol \/ ZF Series and ZF-S Series \u2013 Force Transducers - CAS Scale Korea Co., Ltd.","description":"ZC Series \u2013 Load Cells Product Description *Not available in the US. The force transducers of the ZF \/ ZF-S Series have been designed for the measurement","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/product\/magtrol-zf-series-and-zf-s-series-force-transducers\/","og_locale":"en_US","og_type":"article","og_title":"Magtrol \/ ZF Series and ZF-S Series \u2013 Force Transducers","og_description":"ZC Series \u2013 Load Cells Product Description *Not available in the US. The force transducers of the ZF \/ ZF-S Series have been designed for the measurement","og_url":"https:\/\/casscale.net\/en\/product\/magtrol-zf-series-and-zf-s-series-force-transducers\/","og_site_name":"CAS Scale Korea Co., Ltd.","og_image":[{"width":400,"height":323,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/zf-s.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/product\/magtrol-zf-series-and-zf-s-series-force-transducers\/","url":"https:\/\/casscale.net\/en\/product\/magtrol-zf-series-and-zf-s-series-force-transducers\/","name":"Magtrol \/ ZF Series and ZF-S Series \u2013 Force Transducers - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/product\/magtrol-zf-series-and-zf-s-series-force-transducers\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/product\/magtrol-zf-series-and-zf-s-series-force-transducers\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/zf-s.jpg","datePublished":"2026-02-19T08:40:45+00:00","description":"ZC Series \u2013 Load Cells Product Description *Not available in the US. The force transducers of the ZF \/ ZF-S Series have been designed for the measurement","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/product\/magtrol-zf-series-and-zf-s-series-force-transducers\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/product\/magtrol-zf-series-and-zf-s-series-force-transducers\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/product\/magtrol-zf-series-and-zf-s-series-force-transducers\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/zf-s.jpg","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/zf-s.jpg","width":400,"height":323},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/product\/magtrol-zf-series-and-zf-s-series-force-transducers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"Magtrol \/ ZF Series and ZF-S Series \u2013 Force Transducers"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/product\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/288573","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=288573"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/288572"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=288573"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=288573"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=288573"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=288573"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}