{"id":288577,"date":"2026-02-19T17:43:29","date_gmt":"2026-02-19T08:43:29","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/magtrol-zm-series-force-transducers\/"},"modified":"2026-02-19T17:43:29","modified_gmt":"2026-02-19T08:43:29","slug":"magtrol-zm-series-force-transducers","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/magtrol-zm-series-force-transducers\/","title":{"rendered":"Magtrol \/ ZM Series \u2013 Force Transducers"},"content":{"rendered":"<h4 class=\"product_title entry-title\">ZC Series \u2013 Load Cells<\/h4>\n<h6>Product Description<\/h6>\n<p><strong><em>Note: Not available in the US.<\/em><\/strong><\/p>\n<p>Magtrol\u2019s ZM Series Force Transducers are designed to measure static and dynamic pressure forces. They are characterized by their small dimensions.<\/p>\n<p>Manufactured in stainless steel or high-resistance aluminum, these transducers can be used in a wide variety of applications. In particular, the stainless steel versions with a high degree of protection can be used everywhere without restriction, even in harsh environments.<\/p>\n<p>The sensor element consists of a diaphragm body equipped with metal foil strain gauges, which forms a hermetically sealed chamber filled with dry nitrogen. In standard mounting, the transducers are fixed with screws on a flat surface. The force is introduced vertically (without transverse force) via the universal ball joint, either directly or via a metal adapter interface.<\/p>\n<p>All Magtrol ZM Series transducers are supplied with a 1.5 m long connection cable with loose ends.<\/p>\n<p>Optionally, they can be supplied with a built-in amplifier (ZM\u2011E). Then, an Output Signals of 0 \u2026 10 V DC or 4 \u2026 20 mA can be selected.<\/p>\n<h6>Features<\/h6>\n<ul>\n<li>Nominal Force: 0.1 \u2026 100 kN<\/li>\n<li>Small size; ideal for space-saving applications<\/li>\n<li>Cost effective, high accuracy and long service reliability<\/li>\n<li>Damage-resistant (no mechanically sensitive parts)<\/li>\n<li>Construction with high-strength aluminum alloy or stainless steel<\/li>\n<li>Depending on the model, chemical resistant (suitable for moist environments and chemical plants)<\/li>\n<li>Protection Class: IP 65 or IP 67<\/li>\n<li>Special designs available upon request<\/li>\n<\/ul>\n<h6>ZM Series Specifications<\/h6>\n<table id=\"tablepress-227-no-2\" class=\"tablepress tablepress-id-227\">\n<thead>\n<tr class=\"row-1 odd\">\n<th class=\"column-1\">ACCURACY CLASS\u00a0<sup>a)<\/sup><\/th>\n<th class=\"column-2\">0.5<\/th>\n<th class=\"column-3\">0.2<\/th>\n<th class=\"column-4\">0.1<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n<td class=\"column-1\" colspan=\"4\"><strong>MECHANICAL CHARACTERISTICS<\/strong><\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n<td class=\"column-1\">Nominal Force (=F<sub>N<\/sub>)<\/td>\n<td class=\"column-2\" colspan=\"2\">0.5 \/ 1 \/ 2 \/ 5 \/ 10 \/ 20 \/ 50 \/ 100 kN<\/td>\n<td class=\"column-4\">20 \/ 50 \/ 100 kN<\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n<td class=\"column-1\">Max. Permissible Force\u00a0<sup>b)<\/sup><\/td>\n<td class=\"column-2\" colspan=\"3\">150%<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n<td class=\"column-1\">Breaking Overload\u00a0<sup>b)<\/sup><\/td>\n<td class=\"column-2\" colspan=\"3\">&gt;300%<\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n<td class=\"column-1\">Max. Transverse Force\u00a0<sup>b)<\/sup><\/td>\n<td class=\"column-2\" colspan=\"3\">20%<\/td>\n<\/tr>\n<tr class=\"row-7 odd\">\n<td class=\"column-1\">Combined Error (Linearity &amp; Hysteresis)\u00a0<sup>a,c)<\/sup><\/td>\n<td class=\"column-2\">\u2264 0.5 %<\/td>\n<td class=\"column-3\">\u2264 0.2 %<\/td>\n<td class=\"column-4\">0.1 %<\/td>\n<\/tr>\n<tr class=\"row-8 even\">\n<td class=\"column-1\">Temperature Influence on Zero or Sensitivity\u00a0<sup>c)<\/sup><\/td>\n<td class=\"column-2\">\u2264 0.5 % \/ 10 K<\/td>\n<td class=\"column-3\">\u2264 0.2 % \/ 10 K<\/td>\n<td class=\"column-4\">0.1 % \/ 10 K<\/td>\n<\/tr>\n<tr class=\"row-9 odd\">\n<td class=\"column-1\">Relative Creep (30 min)\u00a0<sup>c)<\/sup><\/td>\n<td class=\"column-2\">\u2264 0.5 %<\/td>\n<td class=\"column-3\">\u2264 0.2 %<\/td>\n<td class=\"column-4\">0.1 %<\/td>\n<\/tr>\n<tr class=\"row-10 even\">\n<td class=\"column-1\">Material<\/td>\n<td class=\"column-2\" colspan=\"3\">Material Special Steel<\/td>\n<\/tr>\n<tr class=\"row-11 odd\">\n<td class=\"column-1\" colspan=\"4\"><strong>ELECTRICAL CHARACTERISTICS<\/strong><\/td>\n<\/tr>\n<tr class=\"row-12 even\">\n<td class=\"column-1\">Nominal Sensitivity (=S)<\/td>\n<td class=\"column-2\" colspan=\"3\">1 mV\/V \u00b10.5 %<\/td>\n<\/tr>\n<tr class=\"row-13 odd\">\n<td class=\"column-1\">Max. Supply Voltage<\/td>\n<td class=\"column-2\" colspan=\"3\">10 V DC<\/td>\n<\/tr>\n<tr class=\"row-14 even\">\n<td class=\"column-1\">Input Resistance<\/td>\n<td class=\"column-2\" colspan=\"3\">380 \u03a9 \u00b130<\/td>\n<\/tr>\n<tr class=\"row-15 odd\">\n<td class=\"column-1\">Output Resistance<\/td>\n<td class=\"column-2\" colspan=\"3\">352 \u03a9 \u00b11.5<\/td>\n<\/tr>\n<tr class=\"row-16 even\">\n<td class=\"column-1\">Insulation Resistance<\/td>\n<td class=\"column-2\" colspan=\"3\">&gt; 5 x 10<sup>9<\/sup>\u00a0\u03a9<\/td>\n<\/tr>\n<tr class=\"row-17 odd\">\n<td class=\"column-1\">Connection Cable<\/td>\n<td class=\"column-2\" colspan=\"3\">Cable, length 1.5 m\u00a0<sup>d)<\/sup><\/td>\n<\/tr>\n<tr class=\"row-18 even\">\n<td class=\"column-1\" colspan=\"4\"><strong>ENVIRONMENT<\/strong><\/td>\n<\/tr>\n<tr class=\"row-19 odd\">\n<td class=\"column-1\">Reference Temperature<\/td>\n<td class=\"column-2\" colspan=\"3\">+23 \u00b0C<\/td>\n<\/tr>\n<tr class=\"row-20 even\">\n<td class=\"column-1\">Nominal Temperature Range<\/td>\n<td class=\"column-2\" colspan=\"3\">-20 \u00b0C &#8230; +60 \u00b0C<\/td>\n<\/tr>\n<tr class=\"row-21 odd\">\n<td class=\"column-1\">Storage Temperature Range<\/td>\n<td class=\"column-2\" colspan=\"3\">-30 \u00b0C &#8230; +70 \u00b0C<\/td>\n<\/tr>\n<tr class=\"row-22 even\">\n<td class=\"column-1\">Protection Class<\/td>\n<td class=\"column-2\" colspan=\"3\">IP 67<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>a) According to VDI 2637<br \/>\nb) % of Nominal Force (Fn)<br \/>\nc) % of Nominal Sensitivity (S)<br \/>\nd) Other length available on request.<\/p>\n<h6>ZM-S Series Specifications<\/h6>\n<table id=\"tablepress-228-no-2\" class=\"tablepress tablepress-id-228\">\n<thead>\n<tr class=\"row-1 odd\">\n<th class=\"column-1\">ACCURACY CLASS<\/th>\n<th class=\"column-2\" colspan=\"3\">1<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n<td class=\"column-1\" colspan=\"4\"><strong>MECHANICAL CHARACTERISTICS<\/strong><\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n<td class=\"column-1\">Nominal Force (=F<sub>N<\/sub>)<\/td>\n<td class=\"column-2\">0.1 \/ 0.2 \/ 0.5 \/ 1 kN<\/td>\n<td class=\"column-3\">5 \/ 10 \/ 20 kN<\/td>\n<td class=\"column-4\">50 kN<\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n<td class=\"column-1\">Max. Permissible Force\u00a0<sup>a)<\/sup><\/td>\n<td class=\"column-2\" colspan=\"3\">150%<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n<td class=\"column-1\">Breaking Overload\u00a0<sup>a)<\/sup><\/td>\n<td class=\"column-2\" colspan=\"3\">&gt;300%<\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n<td class=\"column-1\">Max. Transverse Force\u00a0<sup>a)<\/sup><\/td>\n<td class=\"column-2\" colspan=\"3\">20%<\/td>\n<\/tr>\n<tr class=\"row-7 odd\">\n<td class=\"column-1\">Combined Error (Linearity &amp; Hysteresis)\u00a0<sup>b)<\/sup><\/td>\n<td class=\"column-2\" colspan=\"3\">1 %<\/td>\n<\/tr>\n<tr class=\"row-8 even\">\n<td class=\"column-1\">Temperature Influence on Zero or Sensitivity\u00a0<sup>b)<\/sup><\/td>\n<td class=\"column-2\" colspan=\"3\">\u2264 0.5 % \/ 10 K<\/td>\n<\/tr>\n<tr class=\"row-9 odd\">\n<td class=\"column-1\">Relative Creep (30 min)\u00a0<sup>b)<\/sup><\/td>\n<td class=\"column-2\" colspan=\"3\">\u2264 0.5 %<\/td>\n<\/tr>\n<tr class=\"row-10 even\">\n<td class=\"column-1\">Material<\/td>\n<td class=\"column-2\">High-strength Aluminum Alloy<\/td>\n<td class=\"column-3\" colspan=\"2\">Stainless Steel<\/td>\n<\/tr>\n<tr class=\"row-11 odd\">\n<td class=\"column-1\" colspan=\"4\"><strong>ELECTRICAL CHARACTERISTICS<\/strong><\/td>\n<\/tr>\n<tr class=\"row-12 even\">\n<td class=\"column-1\">Nominal Sensitivity (=S)<\/td>\n<td class=\"column-2\" colspan=\"3\">1 mV\/V \u00b10.5 %<\/td>\n<\/tr>\n<tr class=\"row-13 odd\">\n<td class=\"column-1\">Zero Tolerance Band\u00a0<sup>b)<\/sup><\/td>\n<td class=\"column-2\" colspan=\"3\">\u2264 3 %<\/td>\n<\/tr>\n<tr class=\"row-14 even\">\n<td class=\"column-1\">Max. Supply Voltage<\/td>\n<td class=\"column-2\" colspan=\"3\">10 V DC<\/td>\n<\/tr>\n<tr class=\"row-15 odd\">\n<td class=\"column-1\">Input Resistance<\/td>\n<td class=\"column-2\" colspan=\"2\">380 \u03a9 \u00b130<\/td>\n<td class=\"column-4\">760 \u03a9 \u00b150<\/td>\n<\/tr>\n<tr class=\"row-16 even\">\n<td class=\"column-1\">Output Resistance<\/td>\n<td class=\"column-2\" colspan=\"2\">352 \u03a9 \u00b11.5<\/td>\n<td class=\"column-4\">710 \u03a9 \u00b110<\/td>\n<\/tr>\n<tr class=\"row-17 odd\">\n<td class=\"column-1\">Insulation Resistance<\/td>\n<td class=\"column-2\" colspan=\"3\">&gt;5 \u00d7 10<sup>9<\/sup><\/td>\n<\/tr>\n<tr class=\"row-18 even\">\n<td class=\"column-1\">Connection Cable<\/td>\n<td class=\"column-2\" colspan=\"3\">Cable, length 1.5 m\u00a0<sup>c)<\/sup><\/td>\n<\/tr>\n<tr class=\"row-19 odd\">\n<td class=\"column-1\" colspan=\"4\">ENVIRONMENT<\/td>\n<\/tr>\n<tr class=\"row-20 even\">\n<td class=\"column-1\">Reference Temperature<\/td>\n<td class=\"column-2\" colspan=\"3\">+23 \u00b0C<\/td>\n<\/tr>\n<tr class=\"row-21 odd\">\n<td class=\"column-1\">Nominal Temperature Range<\/td>\n<td class=\"column-2\" colspan=\"3\">-20 \u00b0C &#8230; +60 \u00b0C<\/td>\n<\/tr>\n<tr class=\"row-22 even\">\n<td class=\"column-1\">Storage Temperature Range<\/td>\n<td class=\"column-2\" colspan=\"3\">-30 \u00b0C &#8230; +70 \u00b0C<\/td>\n<\/tr>\n<tr class=\"row-23 odd\">\n<td class=\"column-1\">Protection Class<\/td>\n<td class=\"column-2\" colspan=\"3\">IP 65<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>a) % of Nominal Force (Fn)<br \/>\nb) % of Nominal Sensitivity (S)<br \/>\nc) Other length available on request<\/p>\n","protected":false},"excerpt":{"rendered":"<p>ZC Series \u2013 Load Cells Product Description Note: Not available in the US. Magtrol\u2019s ZM Series Force Transducers are designed to measure static and dynamic pressure forces. They are characterized by their small dimensions. Manufactured in stainless steel or high-resistance aluminum, these transducers can be used in a wide variety of applications. In particular, the [&hellip;]<\/p>\n","protected":false},"featured_media":288576,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5477],"product_cat":[3448],"product_tag":[5030],"class_list":{"0":"post-288577","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-magtrol","7":"product_cat-force-sensor","8":"product_tag-force-sensor-en2","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Magtrol \/ ZM Series \u2013 Force Transducers - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"ZC Series \u2013 Load Cells Product Description Note: Not available in the US. Magtrol\u2019s ZM Series Force Transducers are designed to measure static and dynamic\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/product\/magtrol-zm-series-force-transducers\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Magtrol \/ ZM Series \u2013 Force Transducers\" \/>\n<meta property=\"og:description\" content=\"ZC Series \u2013 Load Cells Product Description Note: Not available in the US. Magtrol\u2019s ZM Series Force Transducers are designed to measure static and dynamic\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/product\/magtrol-zm-series-force-transducers\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/ZM-Series.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"591\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zm-series-force-transducers\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zm-series-force-transducers\\\/\",\"name\":\"Magtrol \\\/ ZM Series \u2013 Force Transducers - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zm-series-force-transducers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zm-series-force-transducers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/ZM-Series.jpg\",\"datePublished\":\"2026-02-19T08:43:29+00:00\",\"description\":\"ZC Series \u2013 Load Cells Product Description Note: Not available in the US. Magtrol\u2019s ZM Series Force Transducers are designed to measure static and dynamic\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zm-series-force-transducers\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zm-series-force-transducers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zm-series-force-transducers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/ZM-Series.jpg\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/ZM-Series.jpg\",\"width\":700,\"height\":591},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/magtrol-zm-series-force-transducers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Magtrol \\\/ ZM Series \u2013 Force Transducers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/product\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Magtrol \/ ZM Series \u2013 Force Transducers - CAS Scale Korea Co., Ltd.","description":"ZC Series \u2013 Load Cells Product Description Note: Not available in the US. Magtrol\u2019s ZM Series Force Transducers are designed to measure static and dynamic","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/product\/magtrol-zm-series-force-transducers\/","og_locale":"en_US","og_type":"article","og_title":"Magtrol \/ ZM Series \u2013 Force Transducers","og_description":"ZC Series \u2013 Load Cells Product Description Note: Not available in the US. Magtrol\u2019s ZM Series Force Transducers are designed to measure static and dynamic","og_url":"https:\/\/casscale.net\/en\/product\/magtrol-zm-series-force-transducers\/","og_site_name":"CAS Scale Korea Co., Ltd.","og_image":[{"width":700,"height":591,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/ZM-Series.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/product\/magtrol-zm-series-force-transducers\/","url":"https:\/\/casscale.net\/en\/product\/magtrol-zm-series-force-transducers\/","name":"Magtrol \/ ZM Series \u2013 Force Transducers - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/product\/magtrol-zm-series-force-transducers\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/product\/magtrol-zm-series-force-transducers\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/ZM-Series.jpg","datePublished":"2026-02-19T08:43:29+00:00","description":"ZC Series \u2013 Load Cells Product Description Note: Not available in the US. Magtrol\u2019s ZM Series Force Transducers are designed to measure static and dynamic","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/product\/magtrol-zm-series-force-transducers\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/product\/magtrol-zm-series-force-transducers\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/product\/magtrol-zm-series-force-transducers\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/ZM-Series.jpg","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/ZM-Series.jpg","width":700,"height":591},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/product\/magtrol-zm-series-force-transducers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"Magtrol \/ ZM Series \u2013 Force Transducers"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/product\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/288577","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=288577"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/288576"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=288577"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=288577"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=288577"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=288577"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}