{"id":289372,"date":"2026-02-23T16:30:57","date_gmt":"2026-02-23T07:30:57","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/primosensor-platform-load-cell-pz-7\/"},"modified":"2026-02-23T16:30:57","modified_gmt":"2026-02-23T07:30:57","slug":"primosensor-platform-load-cell-pz-7","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/primosensor-platform-load-cell-pz-7\/","title":{"rendered":"Primosensor \/ Platform load cell PZ 7"},"content":{"rendered":"<h4>Platform load cell PZ 7<\/p>\n<\/h4>\n<p><strong>Dimensions and Nominal Loads<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-289370\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/PZ7_DataSheet.jpeg\" alt=\"\" width=\"699\" height=\"571\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/PZ7_DataSheet.jpeg 699w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/PZ7_DataSheet-490x400.jpeg 490w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/PZ7_DataSheet-600x490.jpeg 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/PZ7_DataSheet-64x52.jpeg 64w\" sizes=\"(max-width: 699px) 100vw, 699px\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Nominal Load<\/th>\n<th>Output Signal<\/th>\n<th>Order Number<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>10 kg<\/td>\n<td>4\u202620 mA (3-wire)<\/td>\n<td>PZ7010kgA101<\/td>\n<\/tr>\n<tr>\n<td>20 kg<\/td>\n<td>4\u202620 mA (3-wire)<\/td>\n<td>PZ7020kgA101<\/td>\n<\/tr>\n<tr>\n<td>50 kg<\/td>\n<td>4\u202620 mA (3-wire)<\/td>\n<td>PZ7050kgA101<\/td>\n<\/tr>\n<tr>\n<td>100 kg<\/td>\n<td>4\u202620 mA (3-wire)<\/td>\n<td>PZ7100kgA101<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Technical Data<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Technical Data<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Nominal Load (Fnom)<\/td>\n<td>10 \/ 20 \/ 50 \/ 100 kg<\/td>\n<\/tr>\n<tr>\n<td>Platform Size<\/td>\n<td>200 \u00d7 200 mm<\/td>\n<\/tr>\n<tr>\n<td>Limit Load<\/td>\n<td>150 %<\/td>\n<\/tr>\n<tr>\n<td>Breaking Load<\/td>\n<td>300 %<\/td>\n<\/tr>\n<tr>\n<td>Output Signal<\/td>\n<td>4\u202620 mA (3-wire)<\/td>\n<\/tr>\n<tr>\n<td>Optional Outputs<\/td>\n<td>4\u202620 mA (2-wire) \/ 0\u202610 V \/ \u00b110 V (on request)<\/td>\n<\/tr>\n<tr>\n<td>Voltage Supply (UB)<\/td>\n<td>10\u202630 VDC<\/td>\n<\/tr>\n<tr>\n<td>Working Resistance (Rb)<\/td>\n<td>Rb = (UB \u2212 6 V) \/ 0.020 A, max. 500 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Max. Power Consumption<\/td>\n<td>40 mA<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>0.25 % F.S.<\/td>\n<\/tr>\n<tr>\n<td>Nominal Temperature Range<\/td>\n<td>\u221210 \u2026 +50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Service Temperature Range<\/td>\n<td>\u221230 \u2026 +80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature Effect \u2013 Zero<\/td>\n<td>&lt; 0.2 % Fnom \/ 10 K<\/td>\n<\/tr>\n<tr>\n<td>Temperature Effect \u2013 Span<\/td>\n<td>&lt; 0.1 % Fnom \/ 10 K<\/td>\n<\/tr>\n<tr>\n<td>Nominal Deflection<\/td>\n<td>&lt; 0.2 mm<\/td>\n<\/tr>\n<tr>\n<td>Dynamic Load (DIN 50100)<\/td>\n<td>\u00b1 80 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Vibration Resistance<\/td>\n<td>20 g, 100 h, 50 \u2026 150 Hz<\/td>\n<\/tr>\n<tr>\n<td>Protection Type (DIN 60529)<\/td>\n<td>IP 67<\/td>\n<\/tr>\n<tr>\n<td>Electrical Connector<\/td>\n<td>M12 \u00d7 1, 5-pin<\/td>\n<\/tr>\n<tr>\n<td>Deformation Body Material<\/td>\n<td>Aluminium<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>0.3 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<ul class=\"elementor-icon-list-items\">\n<li class=\"elementor-icon-list-item\"><span class=\"elementor-icon-list-text\">Platform scales with only one load cell positioned centrally under the platform<\/span><\/li>\n<li class=\"elementor-icon-list-item\"><i class=\"fas fa-check\" aria-hidden=\"true\"><\/i><span class=\"elementor-icon-list-text\">from 10 kg to 100 kg<\/span><\/li>\n<li class=\"elementor-icon-list-item\"><i class=\"fas fa-check\" aria-hidden=\"true\"><\/i><span class=\"elementor-icon-list-text\">Accuracy &lt;0,25 % v.E.<\/span><\/li>\n<li class=\"elementor-icon-list-item\"><i class=\"fas fa-check\" aria-hidden=\"true\"><\/i><span class=\"elementor-icon-list-text\">Platform size: 200 x 200 mm<\/span><\/li>\n<\/ul>\n<p>This platform force transducer with integrated amplifier electronics was specially developed for applications with eccentric force application or in small platform scales. The special geometry allows only one force transducer to be used under a platform. The sensor is mounted as centrally as possible.<\/p>\n","protected":false},"featured_media":289369,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5505],"product_cat":[3385],"product_tag":[4626],"class_list":{"0":"post-289372","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-primosensor","7":"product_cat-single-point-en","8":"product_tag-single-point-en-2","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/289372","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=289372"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/289369"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=289372"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=289372"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=289372"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=289372"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}