{"id":289378,"date":"2026-02-23T16:46:00","date_gmt":"2026-02-23T07:46:00","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/primosensor-s-type-load-cells-type-wsy\/"},"modified":"2026-02-23T16:46:00","modified_gmt":"2026-02-23T07:46:00","slug":"primosensor-s-type-load-cells-type-wsy","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/primosensor-s-type-load-cells-type-wsy\/","title":{"rendered":"Primosensor \/ S-Type load cells Type WSY"},"content":{"rendered":"<h4>S-Type load cells Type WSY<\/h4>\n<p>S-Type load cells are standard for industrial applications. They are used for measurement of tension and\/or compression. Force indroduction happens via swivel heads. The force transducers adjust themselves if they have enough freedom. As a consequence measurement is very accurate.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-289376\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/WSY_DataSheet-1.jpeg\" alt=\"\" width=\"941\" height=\"559\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/WSY_DataSheet-1.jpeg 941w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/WSY_DataSheet-1-673x400.jpeg 673w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/WSY_DataSheet-1-768x456.jpeg 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/WSY_DataSheet-1-600x356.jpeg 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/WSY_DataSheet-1-64x38.jpeg 64w\" sizes=\"(max-width: 941px) 100vw, 941px\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Nominal Load<\/th>\n<th>Output Signal<\/th>\n<th>Order Number<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>50 \u2013 250 kg<\/td>\n<td>2 mV\/V \u00b1 0.1 %<\/td>\n<td>On request<\/td>\n<\/tr>\n<tr>\n<td>500 kg<\/td>\n<td>2 mV\/V \u00b1 0.004<\/td>\n<td>WSY-500kg-m202<\/td>\n<\/tr>\n<tr>\n<td>1000 kg<\/td>\n<td>2 mV\/V \u00b1 0.004<\/td>\n<td>WSY-001to-m202<\/td>\n<\/tr>\n<tr>\n<td>2000 kg<\/td>\n<td>2 mV\/V \u00b1 0.004<\/td>\n<td>WSY-002to-m202<\/td>\n<\/tr>\n<tr>\n<td>3000 kg<\/td>\n<td>2 mV\/V \u00b1 0.004<\/td>\n<td>WSY-003to-m202<\/td>\n<\/tr>\n<tr>\n<td>4000 kg<\/td>\n<td>2 mV\/V \u00b1 0.004<\/td>\n<td>WSY-004to-m202<\/td>\n<\/tr>\n<tr>\n<td>5000 kg<\/td>\n<td>2 mV\/V \u00b1 0.004<\/td>\n<td>WSY-005to-m202<\/td>\n<\/tr>\n<tr>\n<td>7500 kg<\/td>\n<td>2 mV\/V \u00b1 0.004<\/td>\n<td>WSY-750dkg-m202<\/td>\n<\/tr>\n<tr>\n<td>10000 kg<\/td>\n<td>2 mV\/V \u00b1 0.1 %<\/td>\n<td>On request<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<thead>\n<tr>\n<th>Nominal Load<\/th>\n<th>W (mm)<\/th>\n<th>H (mm)<\/th>\n<th>Thread<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>500 \/ 1000 kg<\/td>\n<td>32<\/td>\n<td>25<\/td>\n<td>M12 \u00d7 1.75<\/td>\n<\/tr>\n<tr>\n<td>2000 \/ 3000 kg<\/td>\n<td>32<\/td>\n<td>25<\/td>\n<td>M20 \u00d7 1.5<\/td>\n<\/tr>\n<tr>\n<td>4000 kg<\/td>\n<td>36<\/td>\n<td>25<\/td>\n<td>M20 \u00d7 1.5<\/td>\n<\/tr>\n<tr>\n<td>5000 \/ 6000 \/ 7500 kg<\/td>\n<td>50<\/td>\n<td>24<\/td>\n<td>M24 \u00d7 2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Technical Data<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Technical Data<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Nominal Load (Fnom)<\/td>\n<td>500 \/ 1000 \/ 2000 \/ 3000 \/ 4000 \/ 5000 \/ 6000 \/ 7500 kg<\/td>\n<\/tr>\n<tr>\n<td>Limit Load<\/td>\n<td>150 %<\/td>\n<\/tr>\n<tr>\n<td>Breaking Load<\/td>\n<td>300 %<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>0.023 % F.S.<\/td>\n<\/tr>\n<tr>\n<td>Creep (20 min)<\/td>\n<td>0.016 % F.S.<\/td>\n<\/tr>\n<tr>\n<td>Output Signal<\/td>\n<td>2.0 mV\/V \u00b1 0.004<\/td>\n<\/tr>\n<tr>\n<td>Optional Outputs<\/td>\n<td>4\u202620 mA or 0\u202610 V (with optional in-line amplifier)<\/td>\n<\/tr>\n<tr>\n<td>Input Resistance<\/td>\n<td>350 \u00b1 3 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Output Resistance<\/td>\n<td>350 \u00b1 3 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Voltage Supply<\/td>\n<td>&lt; 12 V (standard); 11\u202630 VDC (with optional amplifier)<\/td>\n<\/tr>\n<tr>\n<td>Nominal Temperature Range<\/td>\n<td>\u221210 \u2026 +40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Service Temperature Range<\/td>\n<td>\u221235 \u2026 +65 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature Effect \u2013 Zero<\/td>\n<td>&lt; 0.015 % Fnom \/ 10 K<\/td>\n<\/tr>\n<tr>\n<td>Temperature Effect \u2013 Span<\/td>\n<td>&lt; 0.011 % Fnom \/ 10 K<\/td>\n<\/tr>\n<tr>\n<td>Nominal Deflection<\/td>\n<td>&lt; 0.4 mm<\/td>\n<\/tr>\n<tr>\n<td>Electrical Connector<\/td>\n<td>Cable outlet (PUR): 500 kg \u2192 3 m; &gt; 500 kg \u2192 6 m<\/td>\n<\/tr>\n<tr>\n<td>Protection Type (DIN 60529)<\/td>\n<td>IP 68<\/td>\n<\/tr>\n<tr>\n<td>Deformation Body Material<\/td>\n<td>Stainless Steel<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>0.5 \u2013 4 t: approx. 1.9 kg; 5 \u2013 7.5 t: approx. 3.1 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<ul class=\"elementor-icon-list-items\">\n<li class=\"elementor-icon-list-item\"><span class=\"elementor-icon-list-text\">Standard in the industry<\/span><\/li>\n<li class=\"elementor-icon-list-item\"><i class=\"fas fa-check\" aria-hidden=\"true\"><\/i><span class=\"elementor-icon-list-text\">High accuracy<\/span><\/li>\n<li class=\"elementor-icon-list-item\"><i class=\"fas fa-check\" aria-hidden=\"true\"><\/i><span class=\"elementor-icon-list-text\">Measurement of tensile and compressive forces<\/span><\/li>\n<li class=\"elementor-icon-list-item\"><i class=\"fas fa-check\" aria-hidden=\"true\"><\/i><span class=\"elementor-icon-list-text\">from 100 kg to 10,000 kg<\/span><\/li>\n<li class=\"elementor-icon-list-item\"><i class=\"fas fa-check\" aria-hidden=\"true\"><\/i><span class=\"elementor-icon-list-text\">Accuracy &lt;0,020 % F.S.<\/span><\/li>\n<\/ul>\n<p>S-Type load cells are standard for industrial applications. They are used for measurement of tension and\/or compression. Force indroduction happens via swivel heads. The advantages of S-Type load cells are their high level of accuracy, the ability to measure tensile and compressive forces, simple installation and the rotationally symmetrical design.<\/p>\n","protected":false},"featured_media":289375,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5505],"product_cat":[3368],"product_tag":[5368],"class_list":{"0":"post-289378","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-primosensor","7":"product_cat-s-type-load-cell","8":"product_tag-s-type-load-cell-2-en","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/289378","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=289378"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/289375"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=289378"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=289378"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=289378"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=289378"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}