{"id":289413,"date":"2026-02-23T17:20:03","date_gmt":"2026-02-23T08:20:03","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/wika-single-point-load-cell-model-f4802\/"},"modified":"2026-02-23T17:20:03","modified_gmt":"2026-02-23T08:20:03","slug":"wika-single-point-load-cell-model-f4802","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/wika-single-point-load-cell-model-f4802\/","title":{"rendered":"WIKA \/ Single point load cell, model F4802"},"content":{"rendered":"<h4>Single point load cell, model F4802<\/h4>\n<p><strong>Description<br \/>\n<\/strong>The model F4802 single point load cells are a series of aluminium single point load cells suitable for a wide range of applications. Thanks to their standardised geometry and simple design, they can be easily installed in all types of scales.<br \/>\nThe model F4802 load cells are used in various areas such as industry, commerce, medicine and research. The most common application area is in precision, industry and bench scales as well as belt weighers, to measure the weight of products (e.g., food, bulk material, feed). Load cells are also used in the packaging industry, manufacturing as well as material testing.<br \/>\nThe single point load cells feature high accuracy and a quick reponse. Moreover, they are insensitive to lateral and corner loads. The load cells are easy to handle due to their simple force introduction. This is made perpendicular to the geometry.<\/p>\n<p><strong>Specifications per VDI\/VDE\/DKD 2638<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Technical Data<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>F4802<\/td>\n<\/tr>\n<tr>\n<td>Rated Load (Fnom) \u2013 kg<\/td>\n<td>0.3 \/ 0.5 \/ 1 \/ 1.5 \/ 2 \/ 3 \/ 4 \/ 5 \/ 10<\/td>\n<\/tr>\n<tr>\n<td>Rated Load (Fnom) \u2013 lbs<\/td>\n<td>0.7 \/ 1.1 \/ 2.2 \/ 3.3 \/ 4.4 \/ 7 \/ 9 \/ 11 \/ 22<\/td>\n<\/tr>\n<tr>\n<td>Relative Linearity Error (dlin)<\/td>\n<td>\u00b1 0.02 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Relative Creep (30 min)<\/td>\n<td>\u00b1 0.02 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Relative Reversibility Error (v)<\/td>\n<td>\u00b1 0.02 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Relative Deviation of Zero Signal (dS, 0)<\/td>\n<td>\u00b1 2 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Temperature Effect on Zero Signal (TK0)<\/td>\n<td>\u2264 \u00b1 0.02 % \/ 10 K<\/td>\n<\/tr>\n<tr>\n<td>Temperature Effect on Characteristic Value (TKC)<\/td>\n<td>\u2264 \u00b1 0.02 % \/ 10 K<\/td>\n<\/tr>\n<tr>\n<td>Force Limit (FL)<\/td>\n<td>150 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Breaking Force (FB)<\/td>\n<td>200 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Measuring Body Material<\/td>\n<td>Aluminium<\/td>\n<\/tr>\n<tr>\n<td>Rated Temperature Range (BT, nom)<\/td>\n<td>\u221210 \u2026 +40 \u00b0C [+14 \u2026 +104 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td>Operating Temperature Range (BT, G)<\/td>\n<td>\u221220 \u2026 +60 \u00b0C [\u22124 \u2026 +140 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td>Input Resistance (Re)<\/td>\n<td>410 \u00b1 10 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Output Resistance (Ra)<\/td>\n<td>350 \u00b1 5 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Insulation Resistance (Ris)<\/td>\n<td>\u2265 2,000 M\u03a9 \/ DC 100 V<\/td>\n<\/tr>\n<tr>\n<td>Output Signal (Cnom)<\/td>\n<td>2.0 \u00b1 0.2 mV\/V<\/td>\n<\/tr>\n<tr>\n<td>Electrical Connection<\/td>\n<td>Measuring cable \u2205 3 \u00d7 450 mm [\u2205 0.12 \u00d7 17.72 in]<\/td>\n<\/tr>\n<tr>\n<td>Supply Voltage (UB, nom)<\/td>\n<td>DC 10 V (max. 15 V)<\/td>\n<\/tr>\n<tr>\n<td>Ingress Protection (IEC\/EN 60529)<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>Platform Size<\/td>\n<td>200 \u00d7 200 mm [7.87 \u00d7 7.87 in]<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>0.1 kg [0.22 lbs]<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Dimensions in mm [in]<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-289411\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4802.png\" alt=\"\" width=\"1138\" height=\"591\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4802.png 1138w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4802-770x400.png 770w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4802-768x399.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4802-600x312.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4802-64x33.png 64w\" sizes=\"(max-width: 1138px) 100vw, 1138px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p><strong>Applications<\/strong><br \/>\n\u25a0 Precision scales<br \/>\n\u25a0 Industrial scales, medical engineering<br \/>\n\u25a0 Belt weighers<br \/>\n\u25a0 Bench scales<br \/>\n\u25a0 Dosing systems<br \/>\n<strong>Special features<\/strong><br \/>\n\u25a0 Measuring ranges 0 &#8230; 0.3 kg to 0 &#8230; 10 kg<br \/>\n[0 &#8230; 0.7 lbs to 0 &#8230; 22 lbs]<br \/>\n\u25a0 Load cell made from aluminium<br \/>\n\u25a0 High accuracy and quick reponse<br \/>\n\u25a0 Insensitive to lateral and corner load<br \/>\n\u25a0 Simple design, easy installation<\/p>\n","protected":false},"featured_media":289410,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5506],"product_cat":[3385],"product_tag":[4628],"class_list":{"0":"post-289413","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-wika","7":"product_cat-single-point-en","8":"product_tag-single-point-load-cell-en","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/289413","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=289413"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/289410"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=289413"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=289413"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=289413"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=289413"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}