{"id":289419,"date":"2026-02-23T17:24:08","date_gmt":"2026-02-23T08:24:08","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/wika-single-point-load-cell-model-f4801\/"},"modified":"2026-02-23T17:24:08","modified_gmt":"2026-02-23T08:24:08","slug":"wika-single-point-load-cell-model-f4801","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/wika-single-point-load-cell-model-f4801\/","title":{"rendered":"WIKA \/ Single point load cell, model F4801"},"content":{"rendered":"<h4>Single point load cell, model F4802<\/h4>\n<p><strong>Description<br \/>\n<\/strong>The model F4801 single point load cells are a series of aluminium single point load cells suitable for a wide range of applications. Thanks to their standardised geometry and simple design, they can be easily installed in all types of scales.<br \/>\nThe model F4801 load cells are used in various areas such as industry, commerce, medicine and research.<br \/>\nThe most common application area is in precision, industry and bench scales as well as belt weighers, to measure the weight of products (e.g., food, bulk material, feed). Load cells are also used in the packaging industry, manufacturing as well as material testing.<br \/>\nThe single point load cells feature high accuracy and a quick reponse. Moreover, they are insensitive to lateral and corner loads.<br \/>\nThe load cells are easy to handle due to their simple force introduction. This is made perpendicular to the geometry.<\/p>\n<p><strong>Specifications per VDI\/VDE\/DKD 2638<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Technical Data<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>F4801<\/td>\n<\/tr>\n<tr>\n<td>Rated Load (Fnom) \u2013 kg<\/td>\n<td>3 \/ 4 \/ 5 \/ 6 \/ 8 \/ 10 \/ 15 \/ 20 \/ 25 \/ 30 \/ 40 \/ 45 \/ 50 \/ 60 \/ 100 \/ 150 \/ 200 \/ 250<\/td>\n<\/tr>\n<tr>\n<td>Rated Load (Fnom) \u2013 lbs<\/td>\n<td>7 \/ 9 \/ 11 \/ 13 \/ 18 \/ 22 \/ 33 \/ 44 \/ 55 \/ 66 \/ 88 \/ 99 \/ 110 \/ 132 \/ 221 \/ 331 \/ 441 \/ 551<\/td>\n<\/tr>\n<tr>\n<td>Relative Linearity Error (dlin)<\/td>\n<td>\u00b1 0.02 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Relative Creep (30 min)<\/td>\n<td>\u00b1 0.02 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Relative Reversibility Error (v)<\/td>\n<td>\u00b1 0.02 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Relative Deviation of Zero Signal (dS, 0)<\/td>\n<td>\u00b1 2 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Temperature Effect on Zero Signal (TK0)<\/td>\n<td>\u2264 \u00b1 0.02 % \/ 10 K<\/td>\n<\/tr>\n<tr>\n<td>Temperature Effect on Characteristic Value (TKC)<\/td>\n<td>\u2264 \u00b1 0.02 % \/ 10 K<\/td>\n<\/tr>\n<tr>\n<td>Force Limit (FL)<\/td>\n<td>150 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Breaking Force (FB)<\/td>\n<td>200 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Measuring Body Material<\/td>\n<td>Aluminium<\/td>\n<\/tr>\n<tr>\n<td>Rated Temperature Range (BT, nom)<\/td>\n<td>\u221210 \u2026 +40 \u00b0C [+14 \u2026 +104 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td>Operating Temperature Range (BT, G)<\/td>\n<td>\u221220 \u2026 +60 \u00b0C [\u22124 \u2026 +140 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td>Input Resistance (Re)<\/td>\n<td>410 \u00b1 10 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Output Resistance (Ra)<\/td>\n<td>350 \u00b1 5 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Insulation Resistance (Ris)<\/td>\n<td>\u2265 2,000 M\u03a9 \/ DC 100 V<\/td>\n<\/tr>\n<tr>\n<td>Output Signal (Cnom)<\/td>\n<td>2.0 \u00b1 0.2 mV\/V<\/td>\n<\/tr>\n<tr>\n<td>Electrical Connection<\/td>\n<td>Measuring cable \u2205 4 \u00d7 450 mm [\u2205 0.16 \u00d7 17.72 in]<\/td>\n<\/tr>\n<tr>\n<td>Supply Voltage (UB, nom)<\/td>\n<td>DC 10 V (max. 15 V)<\/td>\n<\/tr>\n<tr>\n<td>Ingress Protection (IEC\/EN 60529)<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>Platform Size<\/td>\n<td>250 \u00d7 300 mm [9.84 \u00d7 11.81 in]<\/td>\n<\/tr>\n<tr>\n<td>Weight (3 \u2013 50 kg)<\/td>\n<td>0.3 kg [0.7 lbs]<\/td>\n<\/tr>\n<tr>\n<td>Weight (60 \u2013 250 kg)<\/td>\n<td>0.4 kg [0.9 lbs]<\/td>\n<\/tr>\n<tr>\n<td>Note<\/td>\n<td>Relative linearity error specified per VDI\/VDE\/DKD 2638 (3.2.6)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Dimensions in mm [in]<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-289417\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4801.png\" alt=\"\" width=\"1132\" height=\"528\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4801.png 1132w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4801-800x373.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4801-768x358.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4801-600x280.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4801-64x30.png 64w\" sizes=\"(max-width: 1132px) 100vw, 1132px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<section>\n<h6>Applications<\/h6>\n<ul>\n<li>Precision scales<\/li>\n<li>Industrial scales<\/li>\n<li>Belt weighers<\/li>\n<li>Bench scales<\/li>\n<li>Dosing systems<\/li>\n<\/ul>\n<\/section>\n<section>\n<h6>Special features<\/h6>\n<ul>\n<li>Measurement ranges 0 &#8230; 3 kg to 0 &#8230; 250 kg [0 &#8230; 7 lbs to 0 &#8230; 551 lbs]<\/li>\n<li>Load cell made from aluminium<\/li>\n<li>High accuracy and quick reponse<\/li>\n<li>Insensitive to lateral and corner load<\/li>\n<li>Simple design, easy installation<\/li>\n<\/ul>\n<\/section>\n","protected":false},"featured_media":289416,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5506],"product_cat":[3385],"product_tag":[4628],"class_list":{"0":"post-289419","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-wika","7":"product_cat-single-point-en","8":"product_tag-single-point-load-cell-en","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>WIKA \/ Single point load cell, model F4801 - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"Applications   Precision scales  Industrial scales  Belt weighers  Bench scales  Dosing systems    Special features   Measurement ranges 0 ... 3 kg to 0 ... 250 kg  Load cell made from aluminium  High accuracy and quick reponse  Insensitive to lateral and corner load  Simple design, easy installation\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/product\/wika-single-point-load-cell-model-f4801\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"WIKA \/ Single point load cell, model F4801\" \/>\n<meta property=\"og:description\" content=\"Applications   Precision scales  Industrial scales  Belt weighers  Bench scales  Dosing systems    Special features   Measurement ranges 0 ... 3 kg to 0 ... 250 kg  Load cell made from aluminium  High accuracy and quick reponse  Insensitive to lateral and corner load  Simple design, easy installation\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/product\/wika-single-point-load-cell-model-f4801\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/f4801_en_co_rs_w410_h410_image.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"410\" \/>\n\t<meta property=\"og:image:height\" content=\"410\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-single-point-load-cell-model-f4801\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-single-point-load-cell-model-f4801\\\/\",\"name\":\"WIKA \\\/ Single point load cell, model F4801 - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-single-point-load-cell-model-f4801\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-single-point-load-cell-model-f4801\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/f4801_en_co_rs_w410_h410_image.jpg\",\"datePublished\":\"2026-02-23T08:24:08+00:00\",\"description\":\"Applications Precision scales Industrial scales Belt weighers Bench scales Dosing systems Special features Measurement ranges 0 ... 3 kg to 0 ... 250 kg Load cell made from aluminium High accuracy and quick reponse Insensitive to lateral and corner load Simple design, easy installation\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-single-point-load-cell-model-f4801\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-single-point-load-cell-model-f4801\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-single-point-load-cell-model-f4801\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/f4801_en_co_rs_w410_h410_image.jpg\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/f4801_en_co_rs_w410_h410_image.jpg\",\"width\":410,\"height\":410},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-single-point-load-cell-model-f4801\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"WIKA \\\/ Single point load cell, model F4801\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/product\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"WIKA \/ Single point load cell, model F4801 - CAS Scale Korea Co., Ltd.","description":"Applications   Precision scales  Industrial scales  Belt weighers  Bench scales  Dosing systems    Special features   Measurement ranges 0 ... 3 kg to 0 ... 250 kg  Load cell made from aluminium  High accuracy and quick reponse  Insensitive to lateral and corner load  Simple design, easy installation","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/product\/wika-single-point-load-cell-model-f4801\/","og_locale":"en_US","og_type":"article","og_title":"WIKA \/ Single point load cell, model F4801","og_description":"Applications   Precision scales  Industrial scales  Belt weighers  Bench scales  Dosing systems    Special features   Measurement ranges 0 ... 3 kg to 0 ... 250 kg  Load cell made from aluminium  High accuracy and quick reponse  Insensitive to lateral and corner load  Simple design, easy installation","og_url":"https:\/\/casscale.net\/en\/product\/wika-single-point-load-cell-model-f4801\/","og_site_name":"CAS Scale Korea Co., Ltd.","og_image":[{"width":410,"height":410,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/f4801_en_co_rs_w410_h410_image.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/product\/wika-single-point-load-cell-model-f4801\/","url":"https:\/\/casscale.net\/en\/product\/wika-single-point-load-cell-model-f4801\/","name":"WIKA \/ Single point load cell, model F4801 - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/product\/wika-single-point-load-cell-model-f4801\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/product\/wika-single-point-load-cell-model-f4801\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/f4801_en_co_rs_w410_h410_image.jpg","datePublished":"2026-02-23T08:24:08+00:00","description":"Applications Precision scales Industrial scales Belt weighers Bench scales Dosing systems Special features Measurement ranges 0 ... 3 kg to 0 ... 250 kg Load cell made from aluminium High accuracy and quick reponse Insensitive to lateral and corner load Simple design, easy installation","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/product\/wika-single-point-load-cell-model-f4801\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/product\/wika-single-point-load-cell-model-f4801\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/product\/wika-single-point-load-cell-model-f4801\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/f4801_en_co_rs_w410_h410_image.jpg","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/f4801_en_co_rs_w410_h410_image.jpg","width":410,"height":410},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/product\/wika-single-point-load-cell-model-f4801\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"WIKA \/ Single point load cell, model F4801"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/product\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/289419","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=289419"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/289416"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=289419"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=289419"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=289419"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=289419"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}