{"id":289426,"date":"2026-02-24T09:00:09","date_gmt":"2026-02-24T00:00:09","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/wika-single-point-load-cell-model-f4818\/"},"modified":"2026-02-24T09:00:09","modified_gmt":"2026-02-24T00:00:09","slug":"wika-single-point-load-cell-model-f4818","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/wika-single-point-load-cell-model-f4818\/","title":{"rendered":"WIKA \/ Single point load cell, Model F4818"},"content":{"rendered":"<h4>Single point load cell, Model F4818<\/h4>\n<div class=\"column is-half\">\n<p>The model F4818 single point load cells are a series of aluminium single point load cells suitable for a wide range of applications. Thanks to their standardised geometry and simple design, they can be easily installed in all types of scales.<\/p>\n<p>The model F4818 load cells are used in various are as such as industry, commerce, medicine and research.<\/p>\n<p>The most common application area is in precision, industry and bench scales as well as belt weighers, to measure the weight of products (e.g., food, bulk material, feed). Load cells are also used in the packaging industry, manufacturing as well as material testing.<\/p>\n<\/div>\n<div class=\"column is-half\">\n<p>The single point load cells feature high accuracy and a quick reponse. Moreover, they are insensitive to lateral and corner loads.<\/p>\n<p>The load cells are easy to handle due to their simple force introduction. This is made perpendicular to the geometry.<\/p>\n<p><strong>Specifications per VDI\/VDE\/DKD 2638<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Rated load (Fnom)<\/strong><\/td>\n<td>20 \/ 30 \/ 50 \/ 60 \/ 100 \/ 150 \/ 200 \/ 250 \/ 300 \/ 350 \/ 500 kg<\/td>\n<\/tr>\n<tr>\n<td><strong>Rated load (Fnom)<\/strong><\/td>\n<td>44 \/ 66 \/ 110 \/ 132 \/ 221 \/ 331 \/ 441 \/ 551 \/ 661 \/ 772 \/ 1,102 lbs<\/td>\n<\/tr>\n<tr>\n<td>Relative linearity error (dlin)<\/td>\n<td>\u00b10.02 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Relative creep, 30 min<\/td>\n<td>\u00b10.02 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Relative reversibility error (v)<\/td>\n<td>\u00b10.02 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Relative deviation of zero signal (dS\u2080)<\/td>\n<td>\u00b12 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Temperature effect on zero signal (TK\u2080)<\/td>\n<td>\u2264 \u00b10.025 % \/ 10 K<\/td>\n<\/tr>\n<tr>\n<td>Temperature effect on characteristic value (TKC)<\/td>\n<td>\u2264 \u00b10.025 % \/ 10 K<\/td>\n<\/tr>\n<tr>\n<td>Force limit (FL)<\/td>\n<td>120 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Breaking force (FB)<\/td>\n<td>200 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Material of measuring body<\/td>\n<td>Aluminium<\/td>\n<\/tr>\n<tr>\n<td>Rated temperature range (BT, nom)<\/td>\n<td>-10 \u2026 +40 \u00b0C [+14 \u2026 +104 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature range (BT, G)<\/td>\n<td>-20 \u2026 +60 \u00b0C [-4 \u2026 +140 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td>Input resistance (Re)<\/td>\n<td>410 \u00b110 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Output resistance (Ra)<\/td>\n<td>350 \u00b15 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Insulation resistance (Ris)<\/td>\n<td>\u2265 2,000 M\u03a9 \/ DC 100 V<\/td>\n<\/tr>\n<tr>\n<td>Output signal (Cnom)<\/td>\n<td>2.0 \u00b10.2 mV\/V<\/td>\n<\/tr>\n<tr>\n<td>Electrical connection<\/td>\n<td>Measuring cable \u2205 5 \u00d7 1,500 mm [\u2205 0.19 \u00d7 59.06 in]<\/td>\n<\/tr>\n<tr>\n<td>Supply voltage (UB, nom)<\/td>\n<td>DC 10 V (max. 15 V)<\/td>\n<\/tr>\n<tr>\n<td>Ingress protection<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>Platform size<\/td>\n<td>450 \u00d7 450 mm [17.72 \u00d7 17.72 in]<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>0.6 kg [1.3 lbs]<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>1) Relative linearity error is specified in accordance with guideline VDI\/VDE\/DKD 2638 chapter 3.2.6.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-289424\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4818.png\" alt=\"\" width=\"1150\" height=\"1243\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4818.png 1150w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4818-370x400.png 370w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4818-740x800.png 740w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4818-768x830.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4818-600x649.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4818-64x69.png 64w\" sizes=\"(max-width: 1150px) 100vw, 1150px\" \/><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<section>\n<section>\n<h6>Applications<\/h6>\n<ul>\n<li>Precision scales<\/li>\n<li>Industrial scales, test devices<\/li>\n<li>Belt weighers<\/li>\n<li>Bench scales<\/li>\n<li>Dosing systems<\/li>\n<\/ul>\n<\/section>\n<section>\n<h6>Special features<\/h6>\n<ul>\n<li>Measuring ranges 0 &#8230; 20 kg to 0 &#8230; 500 kg [0 &#8230; 44 lbs to 0 &#8230; 1,102 lbs]<\/li>\n<li>Load cell made from aluminium<\/li>\n<li>High accuracy and quick reponse<\/li>\n<li>Insensitive to lateral and corner load<\/li>\n<li>Simple design, easy installation<\/li>\n<\/ul>\n<\/section>\n<\/section>\n","protected":false},"featured_media":289423,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5506],"product_cat":[3385],"product_tag":[4628],"class_list":{"0":"post-289426","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-wika","7":"product_cat-single-point-en","8":"product_tag-single-point-load-cell-en","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/289426","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=289426"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/289423"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=289426"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=289426"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=289426"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=289426"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}