{"id":289461,"date":"2026-02-24T09:17:10","date_gmt":"2026-02-24T00:17:10","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/wika-single-point-load-cell-model-f4881\/"},"modified":"2026-02-24T09:17:10","modified_gmt":"2026-02-24T00:17:10","slug":"wika-single-point-load-cell-model-f4881","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/wika-single-point-load-cell-model-f4881\/","title":{"rendered":"WIKA \/ Model F4822 Load cell For mobile elevating work platforms"},"content":{"rendered":"<h4>Model F4822 Load cell For mobile elevating work platforms<\/h4>\n<div class=\"column is-half\">\n<p><strong>Fatigue-proof measuring body<\/strong><br \/>\nThe model F4822 load cell for mobile elevating work platforms (MEWP) is designed for static and dynamic measuring requirements in both tension and compression force direction.<br \/>\nIt is made from coated aluminium, which has particularly suitable properties for overload protection in mobile elevating work platforms.<\/p>\n<p><strong>Diverse redundant electronics<\/strong><br \/>\nDue two redundant, opposing channels, the model F4822 ensures precise and reliable load monitoring of the cages of mobile elevating work platforms.<\/p>\n<p><strong>Special protective circuit for high EMC (electromagnetic<\/strong>\u00a0<strong>compatibility)<\/strong><br \/>\nThrough a special protective circuit, harmful high electrical voltages, which can occur in electromagnetic instruments through self-induction, are limited and the voltage rise rate<br \/>\nis reduced. This contributes to the increase of reliability, service life and immunity \u2013 EMC \u2013 and reduction of emitted interference. Its safe operation is crucial for the safety of personnel and machinery.<\/p>\n<\/div>\n<div class=\"column is-half\">\n<p>The model F4822 load cell enables carefree use of mobile elevating work platforms in the industry, logistics sector, facility cleaning and maintenance in public spaces as well as for energy utilities and buildings in indoor and outdoor areas.<\/p>\n<p>The measured force is output as a diverse redundant opposing electrical output signal (4 &#8230; 20 mA\/20 &#8230; 4 mA, 3-wire) to reduce possible sources of errors to an absolute minimum.<\/p>\n<p>Depending on the application, corresponding technical and regional approvals are available.<\/p>\n<p><strong>Technical data<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"662\"><strong>Basic information \/ Version per standard<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Standard<\/strong><\/td>\n<td width=\"379\">In accordance with directive VDI\/VDE\/DKD 2638<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Material of the measuring body<\/strong><\/td>\n<td width=\"379\">Aluminium<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Ingress protection (per IEC\/EN 60529)<\/strong><\/td>\n<td width=\"379\">IP67 and IP69K<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Screw quality<\/strong><\/td>\n<td width=\"379\">10.9 \/ M16 x 1.5 galvanized or chromated<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Weight<\/strong><\/td>\n<td width=\"379\">Approx. 4 kg [8.82 lb]<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"662\"><strong>Measuring element \/ Measurement principle \/ Sensor element<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Type of measuring element<\/strong><\/td>\n<td width=\"379\">Measuring spring (aluminium) with strain gauges<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Force introduction<\/strong><\/td>\n<td width=\"379\">Compression force<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"662\"><strong>Accuracy specifications \/ Repeatability<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Relative linearity error d<\/strong><strong>lin<\/strong><\/td>\n<td width=\"379\">\u2264 0.5 % Fnom<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Influence of torque on the measuring signal<\/strong><\/td>\n<td width=\"379\">\u2264 10 % Fnom<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Temperature effect on zero signal TC<\/strong><strong>0<\/strong><\/td>\n<td width=\"379\">\u2264 \u00b1 0.2 % Fnom\/10 K<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Temperature effect on characteristic value TC<\/strong><strong>C<\/strong><\/td>\n<td width=\"379\">\u2264 \u00b1 0.2 % Fnom\/10 K<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"662\"><strong>Reference conditions<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"283\">Load<\/td>\n<td width=\"379\">\u25a0 \u2264 (UB &#8211; 10 V) \/ 0.02 A (channel 1) \u25a0 \u2264 (UB &#8211; 7 V) \/ 0.02 A (channel 2)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"662\"><strong>Rated load F<\/strong><strong>nom<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>kg<\/strong><\/td>\n<td width=\"379\"><strong>lb<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>2,000<\/strong><\/td>\n<td width=\"379\">4,409<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"662\"><strong>Further information to rated load F<\/strong><strong>nom<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Force limit F<\/strong><strong>L<\/strong><\/td>\n<td width=\"379\">\u2192 See chapter\u00a0<a href=\"#_bookmark0\">\u201eWork load limit (WLL)\u201c<\/a><\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Breaking force F<\/strong><strong>B<\/strong><\/td>\n<td width=\"379\">\u2192 See chapter\u00a0<a href=\"#_bookmark0\">\u201eWork load limit (WLL)\u201c<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"661\"><strong>Output signal<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Rated characteristic value C<\/strong><strong>nom<\/strong><\/td>\n<td width=\"378\">4 &#8230; 20 mA \/20 &#8230; 4 mA, 3-wire, diverse redundant opposing<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"661\"><strong>Auxiliary power<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"283\">Supply voltage UB<\/td>\n<td width=\"378\">DC 9 &#8230; 32 V<\/td>\n<\/tr>\n<tr>\n<td width=\"283\">Current\/power consumption<\/td>\n<td width=\"378\">Voltage output: &lt; 8 mA per channel<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"661\"><strong>Time response\/Dynamic behaviour<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"283\">Response time<\/td>\n<td width=\"378\">&lt; 2 ms (within 10 % &#8230; 90 % Fnom) \u2192 Further response times on request<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"662\"><strong>Voltage supply and performance data<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Electrical safety<\/strong><\/td>\n<td width=\"379\">Reverse polarity and surge protection and short-circuit resistance<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"662\"><strong>Electrical connection<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Connection type<\/strong><\/td>\n<td width=\"379\">Cable outlet, flying leads<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Cable diameter<\/strong><\/td>\n<td width=\"379\">6.6 mm [0.260 in]<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Cable length<\/strong><\/td>\n<td width=\"379\">3 m [9.84 ft]<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Insulation resistance R<\/strong><strong>is<\/strong><\/td>\n<td width=\"379\">&gt; 2 G\u03a9 \/ 100 V<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Material<\/strong><\/td>\n<td width=\"379\">PUR<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Pin assignment<\/strong><br \/>\n<strong>Electrical connection: <\/strong>cable outlet, flying lead<br \/>\n<strong>Output signal: <\/strong>4 &#8230; 20 mA\/20 &#8230; 4 mA, 3-wire, diverse redundant opposing<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"283\"><strong>Signal<\/strong><\/td>\n<td width=\"94\"><strong>channel<\/strong><\/td>\n<td width=\"283\"><strong>Cable colour<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"94\"><strong>UB<\/strong><strong>+\u00a0<\/strong><strong>(CH1)<\/strong><\/td>\n<td width=\"189\">Sensor voltage supply (+)<\/td>\n<td width=\"94\">1<\/td>\n<td width=\"283\">Brown<\/td>\n<\/tr>\n<tr>\n<td width=\"94\"><strong>UB<\/strong><strong>+\u00a0<\/strong><strong>(CH2)<\/strong><\/td>\n<td width=\"189\">Sensor voltage supply (+)<\/td>\n<td width=\"94\">2<\/td>\n<td width=\"283\">White<\/td>\n<\/tr>\n<tr>\n<td width=\"94\"><strong>0 V\/S<\/strong><strong>&#8211;\u00a0<\/strong><strong>(CH1)<\/strong><\/td>\n<td width=\"189\">0-V-potential\/output signal (-)<\/td>\n<td width=\"94\">1<\/td>\n<td width=\"283\">Green<\/td>\n<\/tr>\n<tr>\n<td width=\"94\"><strong>0 V\/S<\/strong><strong>&#8211;\u00a0<\/strong><strong>(CH2)<\/strong><\/td>\n<td width=\"189\">0-V-potential\/output signal (-)<\/td>\n<td width=\"94\">2<\/td>\n<td width=\"283\">Grey<\/td>\n<\/tr>\n<tr>\n<td width=\"94\"><strong>S<\/strong><strong>+\u00a0<\/strong><strong>(CH1)<\/strong><\/td>\n<td width=\"189\">Output signal (+)<\/td>\n<td width=\"94\">1<\/td>\n<td width=\"283\">Yellow<\/td>\n<\/tr>\n<tr>\n<td width=\"94\"><strong>S<\/strong><strong>+\u00a0<\/strong><strong>(CH2)<\/strong><\/td>\n<td width=\"189\">Output signal (+)<\/td>\n<td width=\"94\">2<\/td>\n<td width=\"283\">Pink<\/td>\n<\/tr>\n<tr>\n<td width=\"94\"><strong>Shield<\/strong><\/td>\n<td width=\"189\">Grounding<\/td>\n<td width=\"94\">&#8211;<\/td>\n<td width=\"283\">Green-yellow<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"661\"><strong>Operating conditions<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Rated temperature range B<\/strong><strong>T, nom<\/strong><\/td>\n<td width=\"378\">-20 &#8230; +80 \u00b0C [-4 &#8230; +176 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Operating temperature range B<\/strong><strong>T, G<\/strong><\/td>\n<td width=\"378\">-40 &#8230; +80 \u00b0C [-40 &#8230; +176 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Storage temperature range B<\/strong><strong>T, S<\/strong><\/td>\n<td width=\"378\">-40 &#8230; +85 \u00b0C [-40 &#8230; +185 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Humidity<\/strong><\/td>\n<td width=\"378\">35 &#8230; 85 % relative humidity (non-condensing)<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Vibration resistance F<\/strong><strong>rb\u00a0<\/strong><strong>(per DIN 50100)<\/strong><\/td>\n<td width=\"378\">50 % Fnom<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Operating altitude<\/strong><\/td>\n<td width=\"378\">Up to 2,500 m [6,562 ft] above sea level<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Pollution degree in accordance with UL certification<\/strong><\/td>\n<td width=\"378\">Degree 4: \u201cElectrical equipment for outdoor use\u201d<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"661\"><strong>Packaging and instrument labelling<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Packaging<\/strong><\/td>\n<td width=\"378\">\u25a0 Individual packaging \u25a0 Multiple packaging (up to 20 pieces possible)<\/td>\n<\/tr>\n<tr>\n<td width=\"283\"><strong>Instrument labelling (product label)<\/strong><\/td>\n<td width=\"378\">\u25a0 WIKA product label, glued \u25a0 Customer-specific product label on request<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Work load limit (WLL)<br \/>\n<\/strong>The instrument\u2018s permissible working load was determined based on the safety against breaking load. A factor of 2 was assumed for this, meaning that the equivalent stress in the critical cross-section is at most half the tensile strength of the material.<br \/>\nThis results in the WLL as follows:<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-289457\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4822.png\" alt=\"\" width=\"1147\" height=\"1030\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4822.png 1147w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4822-445x400.png 445w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4822-891x800.png 891w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4822-768x690.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4822-600x539.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4822-64x57.png 64w\" sizes=\"(max-width: 1147px) 100vw, 1147px\" \/><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-289459\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4822_2.png\" alt=\"\" width=\"1149\" height=\"921\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4822_2.png 1149w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4822_2-499x400.png 499w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4822_2-998x800.png 998w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4822_2-768x616.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4822_2-600x481.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F4822_2-64x51.png 64w\" sizes=\"(max-width: 1149px) 100vw, 1149px\" \/><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<section>\n<section>\n<section>\n<section>\n<section>\n<h6>Applications<\/h6>\n<ul>\n<li>Overload protection in mobile elevating work platforms<\/li>\n<li>Industry<\/li>\n<li>Logistics sector<\/li>\n<li>Facility cleaning and maintenance<\/li>\n<li>Energy utilities in indoor and outdoor areas<\/li>\n<\/ul>\n<\/section>\n<section>\n<h6>Special features<\/h6>\n<ul>\n<li>Measuring ranges 0 &#8230; 2,000 kg [0 &#8230; 4,409 lb]<\/li>\n<li>Diverse redundant electronics<\/li>\n<li>Easy mounting by means of a defined hole pattern<\/li>\n<li>Special protective circuit for high EMC<\/li>\n<li>Fatigue-proof measuring body<\/li>\n<\/ul>\n<\/section>\n<\/section>\n<\/section>\n<\/section>\n<\/section>\n","protected":false},"featured_media":289455,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5506],"product_cat":[3385],"product_tag":[4628],"class_list":{"0":"post-289461","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-wika","7":"product_cat-single-point-en","8":"product_tag-single-point-load-cell-en","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/289461","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=289461"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/289455"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=289461"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=289461"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=289461"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=289461"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}