{"id":289473,"date":"2026-02-24T09:40:54","date_gmt":"2026-02-24T00:40:54","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/wika-model-f1102-hydraulic-compression-force-transducer\/"},"modified":"2026-02-24T09:40:54","modified_gmt":"2026-02-24T00:40:54","slug":"wika-model-f1102-hydraulic-compression-force-transducer","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/wika-model-f1102-hydraulic-compression-force-transducer\/","title":{"rendered":"WIKA \/ Model F1102 Hydraulic compression force transducer"},"content":{"rendered":"<div class=\"column is-half\">\n<h4>Model F1102 Hydraulic compression force transducer<\/h4>\n<p>The hydraulic force transducer model F1102 serves to easily capture and display forces in applications of limited mounting space. With its plastic piston, the transducer is especially suited to measure compression forces occurring during closing of welding tongs.<\/p>\n<p>Hydraulic force measurement is a simple way to capture and display the forces occurring in various applications.<\/p>\n<\/div>\n<div class=\"column is-half\">\n<p>The force measurement is made using the principle of hydraulics: The force acting on a piston leads to a pressure increase which can be visualised on a connected display instrument. The scale of the display instrument can be defined in various units (e.g. N, kN, kg, t).<\/p>\n<p><strong>Leak-tightness warranty<\/strong><br \/>\nThe warranty on leak tightness of the hydraulic force measuring unit was extended to 5 years. A force transducer that starts to leak within this period will be repaired free of charge.<\/p>\n<p><strong>Specifications per VDI\/VDE\/DKD 2638<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Rated force (Fnom)<\/strong><\/td>\n<td>0 \u2026 100 N up to 0 \u2026 36 kN<\/td>\n<\/tr>\n<tr>\n<td>Nominal size (NS)<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td><strong>Display \u2013 Standard<\/strong><\/td>\n<td>Pressure gauge 213.40 (NS 63)<\/td>\n<\/tr>\n<tr>\n<td><strong>Display \u2013 Option<\/strong><\/td>\n<td>Digital pressure gauge DG-10<\/td>\n<\/tr>\n<tr>\n<td>Optional (on request)<\/td>\n<td>Pressure sensor<\/td>\n<\/tr>\n<tr>\n<td><strong>Relative linearity error (dlin)<\/strong> \u2013 Standard<\/td>\n<td>\u2264 \u00b11.6 % Fnom (analogue display)<\/td>\n<\/tr>\n<tr>\n<td><strong>Relative linearity error (dlin)<\/strong> \u2013 Option<\/td>\n<td>\u2264 \u00b10.5 % Fnom (pressure sensor \/ digital pressure gauge)<\/td>\n<\/tr>\n<tr>\n<td>Limit force (FL)<\/td>\n<td>100 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Breaking force (FB)<\/td>\n<td>&gt; 130 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Rated displacement (snom)<\/td>\n<td>&lt; 0.5 mm<\/td>\n<\/tr>\n<tr>\n<td>Rated temperature range (BT, nom)<\/td>\n<td>-25 \u2026 +50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ingress protection (EN\/IEC 60529)<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>Case material<\/td>\n<td>Stainless steel<\/td>\n<\/tr>\n<tr>\n<td>Piston material<\/td>\n<td>Plastic (Delrin\u00ae)<\/td>\n<\/tr>\n<tr>\n<td><strong>Mounting type \u2013 Standard<\/strong><\/td>\n<td>Adapter L = 50 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>Mounting type \u2013 Option<\/strong><\/td>\n<td>Capillary \/ Measuring hose (\u201cseparation without any losses\u201d)<\/td>\n<\/tr>\n<tr>\n<td>Fill fluid<\/td>\n<td>Glycerine \/ water (70 % \/ 30 %)<\/td>\n<\/tr>\n<tr>\n<td><strong>Weight<\/strong><\/td>\n<td>0.6 kg (with pressure gauge 213.40 NS 63)<\/td>\n<\/tr>\n<tr>\n<td>&nbsp;<\/td>\n<td>1 kg (with digital pressure gauge DG-10)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>1) For rated forces below 500 N, the relative linearity error is \u00b11.6 % Fnom for all connected measuring instruments.<\/p>\n<p><strong>Dimensions in mm<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-289471\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1102.png\" alt=\"\" width=\"1150\" height=\"654\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1102.png 1150w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1102-703x400.png 703w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1102-768x437.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1102-600x341.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1102-64x36.png 64w\" sizes=\"(max-width: 1150px) 100vw, 1150px\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Rated Force (N\/kN)<\/th>\n<th>System Pressure (bar)<\/th>\n<th>213.40<\/th>\n<th>DG-10<\/th>\n<th>Measuring Hose DN2 (max. L m)<\/th>\n<th>Capillary (max. L m)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>100 N<\/td>\n<td>1.6<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>160 N<\/td>\n<td>2.5<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>250 N<\/td>\n<td>4<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>1.0<\/td>\n<\/tr>\n<tr>\n<td>400 N<\/td>\n<td>6<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>0.5<\/td>\n<td>1.0<\/td>\n<\/tr>\n<tr>\n<td>600 N<\/td>\n<td>10<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>1 kN<\/td>\n<td>16<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>1.2 kN<\/td>\n<td>20<\/td>\n<td>\u2013<\/td>\n<td>\u25cf<\/td>\n<td>1.5<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>1.6 kN<\/td>\n<td>25<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.5<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>2.5 kN<\/td>\n<td>40<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.5<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>3.2 kN<\/td>\n<td>50<\/td>\n<td>\u2013<\/td>\n<td>\u25cf<\/td>\n<td>2.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>4 kN<\/td>\n<td>60<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>2.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>6 kN<\/td>\n<td>100<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>2.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>10 kN<\/td>\n<td>160<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>2.0<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>16 kN<\/td>\n<td>250<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>3.2<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>20 kN<\/td>\n<td>315<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>3.2<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>25 kN<\/td>\n<td>400<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>3.2<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>36 kN<\/td>\n<td>600<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>3.2<\/td>\n<td>6.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Other rated loads and versions on request<br \/>\n\uf06e = possible selection<br \/>\n1) For a rated forces below 500 N, the relative linearity error is \u00b11.6 % Fnom for all connected measuring instruments.<br \/>\n2) Relative linearity error &lt; \u00b11.0 % Fnom<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<section>\n<h6>Applications<\/h6>\n<ul>\n<li>Equipment manufacturing<\/li>\n<li>Construction of jigs and fixtures<\/li>\n<li>Special-purpose machine building<\/li>\n<li>Measuring and control instruments<\/li>\n<\/ul>\n<\/section>\n<section>\n<h6>Special features<\/h6>\n<ul>\n<li>Measuring ranges 0 &#8230; 100 N to 0 &#8230; 36 kN<\/li>\n<li>Relative linearity error \u00b11.0 &#8230; 1.6% F<sub>nom<\/sub>\u00a0with analogue pressure gauge, \u00b10.5 % F<sub>nom<\/sub>\u00a0with digital pressure gauge or pressure sensor<br \/>\n(For rated forces below 500 N, the relative linearity error is \u00b11.6% F<sub>nom<\/sub>\u00a0for all connected measuring instruments.)<\/li>\n<li>Piston stroke \u2264 0.5 mm<\/li>\n<li>Operates without supply voltage<\/li>\n<li>5-year leak-tightness warranty<br \/>\n(Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)<\/li>\n<\/ul>\n<\/section>\n","protected":false},"featured_media":289470,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5506],"product_cat":[3448],"product_tag":[5037,4938,5508],"class_list":{"0":"post-289473","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-wika","7":"product_cat-force-sensor","8":"product_tag-compression-en","9":"product_tag-transducer","10":"product_tag--en","12":"first","13":"instock","14":"taxable","15":"shipping-taxable","16":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/289473","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=289473"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/289470"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=289473"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=289473"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=289473"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=289473"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}