{"id":289479,"date":"2026-02-24T09:45:59","date_gmt":"2026-02-24T00:45:59","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/wika-model-f1103-hydraulic-compression-force-transducer\/"},"modified":"2026-02-24T09:45:59","modified_gmt":"2026-02-24T00:45:59","slug":"wika-model-f1103-hydraulic-compression-force-transducer","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/wika-model-f1103-hydraulic-compression-force-transducer\/","title":{"rendered":"WIKA \/ Model F1103 Hydraulic compression force transducer"},"content":{"rendered":"<div class=\"column is-half\">\n<h4>Model F1103 Hydraulic compression force transducer<\/h4>\n<h6>3-jaw clamping force test instrument NS 3&#215;6 with Bourdon tube pressure gauge 232.57<\/h6>\n<div class=\"column is-half\">\n<p>The hydraulic force transducer model F1103, version NS 3 x 6, is suited for regular testing of the clamping force in 3-jaw chucks. It thereby ensures optimum use of the clamping jaws.<\/p>\n<p>Hydraulic force measurement is a simple way to capture and display the forces occurring in various applications.<\/p>\n<p>The force is measured using the principle of hydraulics: The force acting on a piston leads to a pressure increase that can be visualised on a connected display instrument. The scale of the display instrument can be defined in various units (e.g. N, kN, kg, t).<\/p>\n<\/div>\n<div class=\"column is-half\">\n<p><strong>Leak-tightness warranty<\/strong><br \/>\nThe warranty on leak tightness of the hydraulic force measuring unit was extended to 5 years. A force transducer that starts to leak within this period will be repaired free of charge.<\/p>\n<p>Use of the force measuring unit as intended \u00a0is a prerequisite for the extended 5-year warranty.<\/p>\n<p><strong>Specifications per VDI\/VDE\/DKD 2638<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Rated force (Fnom)<\/strong><\/td>\n<td>0 \u2026 1.1 kN up to 0 \u2026 180 kN<\/td>\n<\/tr>\n<tr>\n<td>Nominal size (NS)<\/td>\n<td>3 \u00d7 6<\/td>\n<\/tr>\n<tr>\n<td><strong>Display \u2013 Standard<\/strong><\/td>\n<td>Pressure gauge 232.57 (NS 100)<\/td>\n<\/tr>\n<tr>\n<td><strong>Display \u2013 Option<\/strong><\/td>\n<td>Digital pressure gauge DG-10<\/td>\n<\/tr>\n<tr>\n<td>Optional (on request)<\/td>\n<td>Pressure sensor<\/td>\n<\/tr>\n<tr>\n<td><strong>Relative linearity error (dlin)<\/strong> \u2013 Standard<\/td>\n<td>\u2264 \u00b11.6 % Fnom (analogue display)<\/td>\n<\/tr>\n<tr>\n<td><strong>Relative linearity error (dlin)<\/strong> \u2013 Option<\/td>\n<td>\u2264 \u00b10.5 % Fnom (pressure sensor \/ digital pressure gauge)<\/td>\n<\/tr>\n<tr>\n<td>Limit force (FL)<\/td>\n<td>100 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Breaking force (FB)<\/td>\n<td>&gt; 130 % Fnom<\/td>\n<\/tr>\n<tr>\n<td><strong>Force introduction \u2013 Standard<\/strong><\/td>\n<td>Total clamping force<\/td>\n<\/tr>\n<tr>\n<td><strong>Force introduction \u2013 Option<\/strong><\/td>\n<td>Clamping force per jaw<\/td>\n<\/tr>\n<tr>\n<td>Rated displacement (snom)<\/td>\n<td>&lt; 0.5 mm<\/td>\n<\/tr>\n<tr>\n<td>Rated temperature range (BT, nom)<\/td>\n<td>-10 \u2026 +50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ingress protection (EN\/IEC 60529)<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>Case material<\/td>\n<td>Stainless steel<\/td>\n<\/tr>\n<tr>\n<td>Piston material<\/td>\n<td>Stainless steel<\/td>\n<\/tr>\n<tr>\n<td><strong>Mounting type \u2013 Standard<\/strong><\/td>\n<td>Adapter L = 50 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>Mounting type \u2013 Option<\/strong><\/td>\n<td>Capillary \/ Measuring hose (\u201cseparation without any losses\u201d)<\/td>\n<\/tr>\n<tr>\n<td>Fill fluid<\/td>\n<td>Glycerine \/ water (70 % \/ 30 %)<\/td>\n<\/tr>\n<tr>\n<td><strong>Weight<\/strong><\/td>\n<td>2.4 kg (with pressure gauge 232.57 NS 100)<\/td>\n<\/tr>\n<tr>\n<td>&nbsp;<\/td>\n<td>2.2 kg (with digital pressure gauge DG-10)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>1) For rated forces below 500 N, the relative linearity error is \u00b11.6 % Fnom for all connected measuring instruments.<\/p>\n<p><strong>Dimensions in mm<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-289477\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1103.png\" alt=\"\" width=\"1146\" height=\"654\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1103.png 1146w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1103-701x400.png 701w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1103-768x438.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1103-600x342.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1103-64x37.png 64w\" sizes=\"(max-width: 1146px) 100vw, 1146px\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Rated Force (kN)<\/th>\n<th>System Pressure (bar)<\/th>\n<th>232.57<\/th>\n<th>DG-10<\/th>\n<th>Measuring Hose DN 2 (max. L m)<\/th>\n<th>Capillary (max. L m)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1.1<\/td>\n<td>6<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>0.5<\/td>\n<td>1.0<\/td>\n<\/tr>\n<tr>\n<td>1.8<\/td>\n<td>10<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>16<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>3.5<\/td>\n<td>20<\/td>\n<td>\u2013<\/td>\n<td>\u25cf<\/td>\n<td>1.5<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>4.8<\/td>\n<td>25<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.5<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>40<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.5<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>50<\/td>\n<td>\u2013<\/td>\n<td>\u25cf<\/td>\n<td>2.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td>60<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>2.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>18<\/td>\n<td>100<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>2.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>30<\/td>\n<td>160<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>2.0<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>45<\/td>\n<td>250<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>3.2<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>75<\/td>\n<td>400<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>3.2<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>110<\/td>\n<td>600<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>3.2<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>180<\/td>\n<td>1,000<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>6.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\uf06e = possible selection<br \/>\n1) For a rated force below 500 N, the relative linearity error is \u00b11.6 % Fnom for all connected measuring instruments.<br \/>\n2) Relative linearity error &lt; \u00b11.0 % Fnom<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<section>\n<h6>Applications<\/h6>\n<ul>\n<li>Measurement of clamping force in three-jaw chucks<\/li>\n<li>Equipment manufacturing<\/li>\n<li>Construction of jigs and fixtures<\/li>\n<li>Special machine building<\/li>\n<li>Measuring and control systems<\/li>\n<\/ul>\n<\/section>\n<section>\n<h6>Special features<\/h6>\n<ul>\n<li>Measuring ranges 0 &#8230; 1.1 kN to 0 &#8230; 180 kN<\/li>\n<li>Relative linearity error \u00b11.0 &#8230; 1.6 % F<sub>nom<\/sub>\u00a0with analogue pressure gauge, \u00b10.5 % F<sub>nom<\/sub>\u00a0with digital pressure gauge or pressure sensor<br \/>\n(For rated loads below 500 N, the accuracy is \u00b11.6 % F<sub>nom<\/sub>\u00a0for all connected measuring instruments.)<\/li>\n<li>Piston stroke \u2264 0.5 mm, force introduction as total clamping force<\/li>\n<li>Operates without supply voltage<\/li>\n<li>5-year leak-tightness warranty<br \/>\n(Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)<\/li>\n<\/ul>\n<\/section>\n","protected":false},"featured_media":289476,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5506],"product_cat":[3448],"product_tag":[5037,4938,5508],"class_list":{"0":"post-289479","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-wika","7":"product_cat-force-sensor","8":"product_tag-compression-en","9":"product_tag-transducer","10":"product_tag--en","12":"first","13":"instock","14":"taxable","15":"shipping-taxable","16":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/289479","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=289479"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/289476"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=289479"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=289479"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=289479"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=289479"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}