{"id":289496,"date":"2026-02-24T10:28:30","date_gmt":"2026-02-24T01:28:30","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/wika-model-f1115-hydraulic-compression-force-transducer\/"},"modified":"2026-02-24T10:28:30","modified_gmt":"2026-02-24T01:28:30","slug":"wika-model-f1115-hydraulic-compression-force-transducer","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/wika-model-f1115-hydraulic-compression-force-transducer\/","title":{"rendered":"WIKA \/ Model F1115 Hydraulic compression force transducer"},"content":{"rendered":"<div class=\"column is-half\">\n<h4>Model F1115 Hydraulic compression force transducer<\/h4>\n<p>Compact version up to 120 kN<\/p>\n<div class=\"column is-half\">\n<p>The compact hydraulic compression force transducer is available from a rated load of 320 N up to 120 kN. Hydraulic force measurement is a simple way to capture and display the forces occurring in various applications. Applications for hydraulic force measurement can be found in equipment manufacturing, in device and special machine building and also with measuring and control systems.<\/p>\n<p>The force is measured using the principle of hydraulics: The force acting on a piston leads to a pressure increase that can be visualised on a connected display instrument. The scale of the display instrument can be defined in various units (e.g. N, kN, kg, t).<\/p>\n<\/div>\n<div class=\"column is-half\">\n<p><strong>Leak-tightness warranty<\/strong><br \/>\nThe warranty on leak tightness of the hydraulic force measuring unit was extended to 5 years. A force transducer that starts to leak within this period will be repaired free of charge.<\/p>\n<p>Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.<\/p>\n<p><strong>Specifications per VDI\/VDE\/DKD 2638<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Rated force (Fnom)<\/strong><\/td>\n<td>0 \u2026 320 N up to 0 \u2026 120 kN<\/td>\n<\/tr>\n<tr>\n<td>Nominal size (NS)<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td><strong>Display \u2013 Standard<\/strong><\/td>\n<td>Pressure gauge 213.40 (NS 63)<\/td>\n<\/tr>\n<tr>\n<td><strong>Display \u2013 Option<\/strong><\/td>\n<td>Digital pressure gauge DG-10<\/td>\n<\/tr>\n<tr>\n<td>&nbsp;<\/td>\n<td>Pressure gauge 232.57 (NS 100), optionally with contacts<\/td>\n<\/tr>\n<tr>\n<td>Optional (on request)<\/td>\n<td>Pressure sensor<\/td>\n<\/tr>\n<tr>\n<td><strong>Relative linearity error (dlin)<\/strong> \u2013 Standard<\/td>\n<td>\u2264 \u00b11.6 % Fnom (analogue display)<\/td>\n<\/tr>\n<tr>\n<td><strong>Relative linearity error (dlin)<\/strong> \u2013 Option<\/td>\n<td>\u2264 \u00b10.5 % Fnom (pressure sensor \/ digital pressure gauge)<\/td>\n<\/tr>\n<tr>\n<td>Limit force (FL)<\/td>\n<td>100 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Breaking force (FB)<\/td>\n<td>&gt; 130 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Rated displacement (snom)<\/td>\n<td>&lt; 0.5 mm<\/td>\n<\/tr>\n<tr>\n<td>Rated temperature range (BT, nom)<\/td>\n<td>-25 \u2026 +50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ingress protection (EN\/IEC 60529)<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>Case material<\/td>\n<td>Stainless steel<\/td>\n<\/tr>\n<tr>\n<td>Piston material<\/td>\n<td>Stainless steel<\/td>\n<\/tr>\n<tr>\n<td><strong>Mounting type \u2013 Standard<\/strong><\/td>\n<td>Direct mounting<\/td>\n<\/tr>\n<tr>\n<td><strong>Mounting type \u2013 Option<\/strong><\/td>\n<td>Adapter \/ Capillary \/ Measuring hose (\u201cseparation without any losses\u201d)<\/td>\n<\/tr>\n<tr>\n<td>Fill fluid<\/td>\n<td>Glycerine \/ water (70 % \/ 30 %)<\/td>\n<\/tr>\n<tr>\n<td>Assembly aid<\/td>\n<td>Threaded holes on bottom of case<\/td>\n<\/tr>\n<tr>\n<td><strong>Weight<\/strong><\/td>\n<td>2.1 kg (with pressure gauge 213.40 NS 63)<\/td>\n<\/tr>\n<tr>\n<td>&nbsp;<\/td>\n<td>2.3 kg (with digital pressure gauge DG-10)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>1) For rated forces below 500 N, the relative linearity error is \u00b11.6 % Fnom for all connected measuring instruments.<\/p>\n<p><strong>Dimensions in mm<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-289494\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1115.png\" alt=\"\" width=\"1144\" height=\"646\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1115.png 1144w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1115-708x400.png 708w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1115-768x434.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1115-600x339.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1115-64x36.png 64w\" sizes=\"(max-width: 1144px) 100vw, 1144px\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Rated Force (N\/kN)<\/th>\n<th>System Pressure (bar)<\/th>\n<th>213.40<\/th>\n<th>DG-10<\/th>\n<th>Measuring Hose DN 2 (max. L m)<\/th>\n<th>Capillary (max. L m)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>320 N<\/td>\n<td>1.6<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>500 N<\/td>\n<td>2.5<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>800 N<\/td>\n<td>4<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>1.0<\/td>\n<\/tr>\n<tr>\n<td>1.2 kN<\/td>\n<td>6<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>0.5<\/td>\n<td>1.0<\/td>\n<\/tr>\n<tr>\n<td>2 kN<\/td>\n<td>10<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>3.2 kN<\/td>\n<td>16<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>4 kN<\/td>\n<td>20<\/td>\n<td>\u2013<\/td>\n<td>\u25cf<\/td>\n<td>1.5<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>5 kN<\/td>\n<td>25<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.5<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>8 kN<\/td>\n<td>40<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.5<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>10 kN<\/td>\n<td>50<\/td>\n<td>\u2013<\/td>\n<td>\u25cf<\/td>\n<td>2.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>12 kN<\/td>\n<td>60<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>2.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>20 kN<\/td>\n<td>100<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>2.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>32 kN<\/td>\n<td>160<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>2.0<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>50 kN<\/td>\n<td>250<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>3.2<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>60 kN<\/td>\n<td>315<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>3.2<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>80 kN<\/td>\n<td>400<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>3.2<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>120 kN<\/td>\n<td>600<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>3.2<\/td>\n<td>6.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\uf06e = possible selection<br \/>\n1) For a rated force below 500 N, the relative linearity error is \u00b11.6 % Fnom for all connected measuring instruments.<br \/>\n2) Relative linearity error &lt; \u00b11.0 % Fnom<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<section>\n<h6>Applications<\/h6>\n<ul>\n<li>Equipment manufacturing<\/li>\n<li>Construction of jigs and fixtures<\/li>\n<li>Special machine building<\/li>\n<li>Measuring and control systems<\/li>\n<\/ul>\n<\/section>\n<section>\n<h6>Special features<\/h6>\n<ul>\n<li>Measuring ranges 0 &#8230; 320 N to 0 &#8230; 120 kN<\/li>\n<li>Relative linearity error \u00b11.0 &#8230; 1.6 % F<sub>nom<\/sub>\u00a0with analogue pressure gauge, \u00b10.5 % F<sub>nom<\/sub>\u00a0with digital pressure gauge or pressure sensor<br \/>\n(For rated loads below 500 N, the accuracy is \u00b11.6 % F<sub>nom<\/sub>\u00a0for all connected measuring instruments.)<\/li>\n<li>Piston stroke \u2264 0.5 mm<\/li>\n<li>Operates without supply voltage<\/li>\n<li>5-year leak-tightness warranty<br \/>\n(Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)<\/li>\n<li>\u00a0<\/li>\n<\/ul>\n<\/section>\n","protected":false},"featured_media":289493,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5506],"product_cat":[3448],"product_tag":[5037,4938,5508],"class_list":{"0":"post-289496","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-wika","7":"product_cat-force-sensor","8":"product_tag-compression-en","9":"product_tag-transducer","10":"product_tag--en","12":"first","13":"instock","14":"taxable","15":"shipping-taxable","16":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/289496","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=289496"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/289493"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=289496"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=289496"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=289496"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=289496"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}