{"id":289515,"date":"2026-02-24T10:53:29","date_gmt":"2026-02-24T01:53:29","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/wika-model-f1122-hydraulic-compression-force-transducer\/"},"modified":"2026-02-24T10:53:29","modified_gmt":"2026-02-24T01:53:29","slug":"wika-model-f1122-hydraulic-compression-force-transducer","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/wika-model-f1122-hydraulic-compression-force-transducer\/","title":{"rendered":"WIKA \/ Model F1122 Hydraulic compression force transducer"},"content":{"rendered":"<div class=\"column is-half\">\n<h4>Model F1122 Hydraulic compression force transducer<\/h4>\n<p>NS 3 x 33, 3-jaw clamping force test instrument up to 1,000 kN<\/p>\n<div class=\"column is-half\">\n<p>The hydraulic force transducer model F1122, version NS 3 x 33, is suited for regular testing of the clamping force in 3-jaw chucks. It thereby ensures optimum use of the clamping jaws.<\/p>\n<p>Hydraulic force measurement is a simple way to capture and display the forces occurring in various applications.<\/p>\n<p>The force is measured using the principle of hydraulics: The force acting on a piston leads to a pressure increase that can be visualised on a connected display instrument. The scale of the display instrument can be defined in various units (e.g. N, kN, kg, t).<\/p>\n<\/div>\n<div class=\"column is-half\">\n<p><strong>Leak-tightness warranty<\/strong><br \/>\nThe warranty on leak tightness of the hydraulic force measuring unit was extended to 5 years. A force transducer that starts to leak within this period will be repaired free of charge.<\/p>\n<p>Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.<\/p>\n<p><strong>Specifications per VDI\/VDE\/DKD 2638<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Rated force (Fnom)<\/strong><\/td>\n<td>0 \u2026 6 kN to 0 \u2026 1,000 kN<\/td>\n<\/tr>\n<tr>\n<td>Nominal size (NS)<\/td>\n<td>3 \u00d7 16<\/td>\n<\/tr>\n<tr>\n<td><strong>Display \u2013 Standard<\/strong><\/td>\n<td>Pressure gauge 232.57 (NS 100)<\/td>\n<\/tr>\n<tr>\n<td><strong>Display \u2013 Option<\/strong><\/td>\n<td>Digital pressure gauge DG-10<\/td>\n<\/tr>\n<tr>\n<td>&nbsp;<\/td>\n<td>Pressure sensor (on request)<\/td>\n<\/tr>\n<tr>\n<td><strong>Relative linearity error (dlin) \u2013 Standard<\/strong><\/td>\n<td>\u2264 \u00b11.6 % Fnom (analogue display)<\/td>\n<\/tr>\n<tr>\n<td><strong>Relative linearity error (dlin) \u2013 Option<\/strong><\/td>\n<td>\u2264 \u00b10.5 % Fnom (pressure sensor \/ digital pressure gauge)<\/td>\n<\/tr>\n<tr>\n<td>Limit force (FL)<\/td>\n<td>100 % Fnom<\/td>\n<\/tr>\n<tr>\n<td>Breaking force (FB)<\/td>\n<td>&gt; 130 % Fnom<\/td>\n<\/tr>\n<tr>\n<td><strong>Force introduction \u2013 Standard<\/strong><\/td>\n<td>Total clamping force<\/td>\n<\/tr>\n<tr>\n<td><strong>Force introduction \u2013 Option<\/strong><\/td>\n<td>Clamping force per jaw<\/td>\n<\/tr>\n<tr>\n<td>Rated displacement (snom)<\/td>\n<td>&lt; 0.5 mm<\/td>\n<\/tr>\n<tr>\n<td>Rated temperature range (BT, nom)<\/td>\n<td>-10 \u2026 +50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ingress protection<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>Case<\/td>\n<td>Stainless steel<\/td>\n<\/tr>\n<tr>\n<td>Piston<\/td>\n<td>Stainless steel<\/td>\n<\/tr>\n<tr>\n<td><strong>Mounting type \u2013 Standard<\/strong><\/td>\n<td>Adapter L = 50 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>Mounting type \u2013 Option<\/strong><\/td>\n<td>Capillary<\/td>\n<\/tr>\n<tr>\n<td>&nbsp;<\/td>\n<td>Measuring hose (\u201cseparation without any losses\u201d)<\/td>\n<\/tr>\n<tr>\n<td>Fill fluid<\/td>\n<td>Glycerine \/ water (70 % \/ 30 %)<\/td>\n<\/tr>\n<tr>\n<td><strong>Weight<\/strong><\/td>\n<td>6.9 kg (with pressure gauge 232.57)<\/td>\n<\/tr>\n<tr>\n<td>&nbsp;<\/td>\n<td>6.7 kg (with digital pressure gauge DG-10)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>1) For rated forces below 500 N, the relative linearity error is \u00b11.6 % Fnom for all connected measuring instruments.<\/p>\n<p><strong>Dimensions in mm<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-289513\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1122.png\" alt=\"\" width=\"1141\" height=\"646\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1122.png 1141w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1122-707x400.png 707w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1122-768x435.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1122-600x340.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1122-64x36.png 64w\" sizes=\"(max-width: 1141px) 100vw, 1141px\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Rated Force (kN)<\/th>\n<th>System Pressure (bar)<\/th>\n<th>232.57<\/th>\n<th>DG-10<\/th>\n<th>Measuring Hose DN 2 (max. L) [m]<\/th>\n<th>Capillary (max. L) [m]<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>6<\/td>\n<td>6<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>0.5<\/td>\n<td>1.0<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>10<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>16<\/td>\n<td>16<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>20<\/td>\n<td>20<\/td>\n<td>\u2013<\/td>\n<td>\u25cf<\/td>\n<td>1.5<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>25<\/td>\n<td>25<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.5<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>40<\/td>\n<td>40<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>1.5<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>50<\/td>\n<td>50<\/td>\n<td>\u2013<\/td>\n<td>\u25cf<\/td>\n<td>2.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>60<\/td>\n<td>60<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>2.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>100<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>2.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>160<\/td>\n<td>160<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>2.0<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>250<\/td>\n<td>250<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>3.2<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>400<\/td>\n<td>400<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>3.2<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>600<\/td>\n<td>600<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>3.2<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>1,000<\/td>\n<td>1,000<\/td>\n<td>\u25cf<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>6.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\uf06e = possible selection<br \/>\n1) For a rated force below 500 N, the relative linearity error is \u00b11.6 % Fnom for all connected measuring instruments.<br \/>\n2) Relative linearity error &lt; \u00b11.0 % Fnom<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<section>\n<h6>Applications<\/h6>\n<ul>\n<li>Measurement of clamping force in three-jaw chucks<\/li>\n<li>Equipment manufacturing<\/li>\n<li>Construction of jigs and fixtures<\/li>\n<li>Special machine building<\/li>\n<li>Measuring and control instruments<\/li>\n<\/ul>\n<\/section>\n<section>\n<h6>Special features<\/h6>\n<ul>\n<li>Measuring ranges 0 &#8230; 6 kN to 0 &#8230; 1,000 kN<\/li>\n<li>Relative linearity error \u00b11.0 &#8230; 1.6 % F<sub>nom<\/sub>\u00a0with analogue pressure gauge, \u00b10.5 % F<sub>nom<\/sub>\u00a0with digital pressure gauge or pressure sensor<br \/>\n(For rated loads below 500 N, the accuracy is \u00b11.6 % F<sub>nom<\/sub>\u00a0for all connected measuring instruments.)<\/li>\n<li>Piston stroke \u2264 0.5 mm, force introduction as total clamping force<\/li>\n<li>Operates without supply voltage<\/li>\n<li>5-year leak-tightness warranty<br \/>\n(Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)<\/li>\n<\/ul>\n<\/section>\n","protected":false},"featured_media":289512,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5506],"product_cat":[3448],"product_tag":[5037,4938,5508],"class_list":{"0":"post-289515","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-wika","7":"product_cat-force-sensor","8":"product_tag-compression-en","9":"product_tag-transducer","10":"product_tag--en","12":"first","13":"instock","14":"taxable","15":"shipping-taxable","16":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>WIKA \/ Model F1122 Hydraulic compression force transducer - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"Applications   Measurement of clamping force in three-jaw chucks  Equipment manufacturing  Construction of jigs and fixtures  Special machine building  Measuring and control instruments    Special features   Measuring ranges 0 ... 6 kN to 0 ... 1,000 kN  Relative linearity error \u00b11.0 ... 1.6 % Fnom\u00a0with analogue pressure gauge, \u00b10.5 % Fnom\u00a0with digital pressure gauge or pressure sensor (For rated loads below 500 N, the accuracy is \u00b11.6 % Fnom\u00a0for all connected measuring instruments.)  Piston stroke \u2264 0.5 mm, force introduction as total clamping force  Operates without supply voltage  5-year leak-tightness warranty (Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/product\/wika-model-f1122-hydraulic-compression-force-transducer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"WIKA \/ Model F1122 Hydraulic compression force transducer\" \/>\n<meta property=\"og:description\" content=\"Applications   Measurement of clamping force in three-jaw chucks  Equipment manufacturing  Construction of jigs and fixtures  Special machine building  Measuring and control instruments    Special features   Measuring ranges 0 ... 6 kN to 0 ... 1,000 kN  Relative linearity error \u00b11.0 ... 1.6 % Fnom\u00a0with analogue pressure gauge, \u00b10.5 % Fnom\u00a0with digital pressure gauge or pressure sensor (For rated loads below 500 N, the accuracy is \u00b11.6 % Fnom\u00a0for all connected measuring instruments.)  Piston stroke \u2264 0.5 mm, force introduction as total clamping force  Operates without supply voltage  5-year leak-tightness warranty (Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/product\/wika-model-f1122-hydraulic-compression-force-transducer\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/f1122_en_co_rs_w410_h410_image.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"410\" \/>\n\t<meta property=\"og:image:height\" content=\"410\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1122-hydraulic-compression-force-transducer\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1122-hydraulic-compression-force-transducer\\\/\",\"name\":\"WIKA \\\/ Model F1122 Hydraulic compression force transducer - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1122-hydraulic-compression-force-transducer\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1122-hydraulic-compression-force-transducer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/f1122_en_co_rs_w410_h410_image.jpg\",\"datePublished\":\"2026-02-24T01:53:29+00:00\",\"description\":\"Applications Measurement of clamping force in three-jaw chucks Equipment manufacturing Construction of jigs and fixtures Special machine building Measuring and control instruments Special features Measuring ranges 0 ... 6 kN to 0 ... 1,000 kN Relative linearity error \u00b11.0 ... 1.6 % Fnom\u00a0with analogue pressure gauge, \u00b10.5 % Fnom\u00a0with digital pressure gauge or pressure sensor (For rated loads below 500 N, the accuracy is \u00b11.6 % Fnom\u00a0for all connected measuring instruments.) Piston stroke \u2264 0.5 mm, force introduction as total clamping force Operates without supply voltage 5-year leak-tightness warranty (Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1122-hydraulic-compression-force-transducer\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1122-hydraulic-compression-force-transducer\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1122-hydraulic-compression-force-transducer\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/f1122_en_co_rs_w410_h410_image.jpg\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/f1122_en_co_rs_w410_h410_image.jpg\",\"width\":410,\"height\":410},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1122-hydraulic-compression-force-transducer\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"WIKA \\\/ Model F1122 Hydraulic compression force transducer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/product\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"WIKA \/ Model F1122 Hydraulic compression force transducer - CAS Scale Korea Co., Ltd.","description":"Applications   Measurement of clamping force in three-jaw chucks  Equipment manufacturing  Construction of jigs and fixtures  Special machine building  Measuring and control instruments    Special features   Measuring ranges 0 ... 6 kN to 0 ... 1,000 kN  Relative linearity error \u00b11.0 ... 1.6 % Fnom\u00a0with analogue pressure gauge, \u00b10.5 % Fnom\u00a0with digital pressure gauge or pressure sensor (For rated loads below 500 N, the accuracy is \u00b11.6 % Fnom\u00a0for all connected measuring instruments.)  Piston stroke \u2264 0.5 mm, force introduction as total clamping force  Operates without supply voltage  5-year leak-tightness warranty (Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/product\/wika-model-f1122-hydraulic-compression-force-transducer\/","og_locale":"en_US","og_type":"article","og_title":"WIKA \/ Model F1122 Hydraulic compression force transducer","og_description":"Applications   Measurement of clamping force in three-jaw chucks  Equipment manufacturing  Construction of jigs and fixtures  Special machine building  Measuring and control instruments    Special features   Measuring ranges 0 ... 6 kN to 0 ... 1,000 kN  Relative linearity error \u00b11.0 ... 1.6 % Fnom\u00a0with analogue pressure gauge, \u00b10.5 % Fnom\u00a0with digital pressure gauge or pressure sensor (For rated loads below 500 N, the accuracy is \u00b11.6 % Fnom\u00a0for all connected measuring instruments.)  Piston stroke \u2264 0.5 mm, force introduction as total clamping force  Operates without supply voltage  5-year leak-tightness warranty (Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)","og_url":"https:\/\/casscale.net\/en\/product\/wika-model-f1122-hydraulic-compression-force-transducer\/","og_site_name":"CAS Scale Korea Co., Ltd.","og_image":[{"width":410,"height":410,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/f1122_en_co_rs_w410_h410_image.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/product\/wika-model-f1122-hydraulic-compression-force-transducer\/","url":"https:\/\/casscale.net\/en\/product\/wika-model-f1122-hydraulic-compression-force-transducer\/","name":"WIKA \/ Model F1122 Hydraulic compression force transducer - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/product\/wika-model-f1122-hydraulic-compression-force-transducer\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/product\/wika-model-f1122-hydraulic-compression-force-transducer\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/f1122_en_co_rs_w410_h410_image.jpg","datePublished":"2026-02-24T01:53:29+00:00","description":"Applications Measurement of clamping force in three-jaw chucks Equipment manufacturing Construction of jigs and fixtures Special machine building Measuring and control instruments Special features Measuring ranges 0 ... 6 kN to 0 ... 1,000 kN Relative linearity error \u00b11.0 ... 1.6 % Fnom\u00a0with analogue pressure gauge, \u00b10.5 % Fnom\u00a0with digital pressure gauge or pressure sensor (For rated loads below 500 N, the accuracy is \u00b11.6 % Fnom\u00a0for all connected measuring instruments.) Piston stroke \u2264 0.5 mm, force introduction as total clamping force Operates without supply voltage 5-year leak-tightness warranty (Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/product\/wika-model-f1122-hydraulic-compression-force-transducer\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/product\/wika-model-f1122-hydraulic-compression-force-transducer\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/product\/wika-model-f1122-hydraulic-compression-force-transducer\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/f1122_en_co_rs_w410_h410_image.jpg","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/f1122_en_co_rs_w410_h410_image.jpg","width":410,"height":410},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/product\/wika-model-f1122-hydraulic-compression-force-transducer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"WIKA \/ Model F1122 Hydraulic compression force transducer"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/product\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/289515","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=289515"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/289512"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=289515"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=289515"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=289515"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=289515"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}