{"id":289527,"date":"2026-02-24T11:17:31","date_gmt":"2026-02-24T02:17:31","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/wika-model-f1135-hydraulic-compression-force-transducer\/"},"modified":"2026-02-24T11:17:31","modified_gmt":"2026-02-24T02:17:31","slug":"wika-model-f1135-hydraulic-compression-force-transducer","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/wika-model-f1135-hydraulic-compression-force-transducer\/","title":{"rendered":"WIKA \/ Model F1135 Hydraulic compression force transducer"},"content":{"rendered":"<div class=\"column is-half\">\n<h4>Model F1135 Hydraulic compression force transducer<\/h4>\n<p>Compact version up to 480 kN<\/p>\n<div class=\"column is-half\">\n<p>The compact hydraulic compression force transducer model F1135 is available with a nominal size NS 80. Measurement of rated forces from 2 up to 480 kN are possible. Through the robust mechanical assembly of the hydraulic compression force transducers, they are ideally suited for use in harsh environmental conditions. Applications for this hydraulic force measurement can be found in equipment manufacturing, in device and special machine building and also with measuring and control systems.<\/p>\n<p>Hydraulic force transducers operate on the principle that the force acting on the piston is converted into a hydraulic pressure &#8211; in proportion to the piston surface area.<\/p>\n<\/div>\n<div class=\"column is-half\">\n<p>Via the connected measuring instrument, which can be either analogue or digital, the measured value is output. The scale of the connected pressure gauge can be defined in various units, e.g., in N, kN, kg, or even t.<\/p>\n<p><strong>Leak-tightness warranty<\/strong><br \/>\nThe warranty on leak tightness of the hydraulic force measuring unit was extended to 5 years. A force transducer that starts to leak within this period will be repaired free of charge.<\/p>\n<p>Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.<\/p>\n<p>1) For rated forces below 500 N, the relative linearity error is \u00b11.6 % Fnom for all connected<br \/>\nmeasuring instruments.<br \/>\n2) Use of the force measuring unit as intended is a prerequisite for the extended 5-year<br \/>\nwarranty.<\/p>\n<p><strong>Specifications per VDI\/VDE\/DKD 2638<\/strong><\/p>\n<div style=\"overflow: auto;\">\n<table style=\"width: 100%; border-collapse: collapse;\">\n<thead>\n<tr>\n<th style=\"text-align: left; padding: 10px; border-bottom: 2px solid #ddd; font-size: 1.05em;\" colspan=\"2\">Model F1135 \u2014 Product Specifications<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"width: 32%; padding: 8px; border-bottom: 1px solid #eee;\"><strong>Model<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">F1135<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Rated force Fnom<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">0 &#8230; 2 kN to 0 &#8230; 480 kN<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Nominal size\u00a0<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">NS 80<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Display\u00a0<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u25a0\u25a0 Standard: Pressure gauge 213.40 (NS 63)<br \/>\n\u25a0\u25a0 Option: Digital pressure gauge DG-10; Pressure gauge PSG23.160 (NS 100), optionally with contacts; Pressure sensor (on request)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Relative linearity error dlin<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u25a0\u25a0 Standard: \u2264 \u00b11.6 % Fnom (analogue display)1)<br \/>\n\u25a0\u25a0 Option: \u2264 \u00b10.5 % Fnom (pressure sensor\/digital pressure gauge)1)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Limit force FL<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">100 % Fnom<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Breaking force FB<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&gt; 130 % Fnom<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Rated displacement snom<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&lt; 0.5 mm<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Rated temperature range BT, nom<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">-25 \u2026 +50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Ingress protection (per EN\/IEC 60529)<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">IP65<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Case<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Stainless steel<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Piston<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Stainless steel<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Mounting type<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u25a0\u25a0 Standard: Direct<br \/>\n\u25a0\u25a0 Option: Adapter, capillary, measuring hose for &#8220;separation without any losses&#8221;<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Fill fluid<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Glycerine\/water 70 %\/30 %<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Assembly aid<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Threaded holes on the bottom of the case<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Options<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Spacer disc<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\"><strong>Weight in kg<\/strong><\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u25a0\u25a0 with pressure gauge 213.40 (NS 63): 4.6<br \/>\n\u25a0\u25a0 with digital pressure gauge DG-10: 4.8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><!-- Note --><\/p>\n<p>1) For rated forces below 500 N, the relative linearity error is \u00b11.6 % Fnom for all connected measuring instruments.<\/p>\n<p><strong>Dimensions in mm<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-289525\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1135.png\" alt=\"\" width=\"1146\" height=\"655\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1135.png 1146w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1135-700x400.png 700w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1135-768x439.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1135-600x343.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1135-64x37.png 64w\" sizes=\"(max-width: 1146px) 100vw, 1146px\" \/><\/p>\n<div style=\"overflow: auto;\">\n<table style=\"width: 100%; border-collapse: collapse;\">\n<thead>\n<tr>\n<th style=\"text-align: left; padding: 10px; border-bottom: 2px solid #ddd; font-size: 1.05em;\" colspan=\"6\">Version \u2014 Display Options<\/th>\n<\/tr>\n<tr>\n<th style=\"text-align: left; padding: 8px; border-bottom: 1px solid #eee;\">Rated force (kN)<\/th>\n<th style=\"text-align: left; padding: 8px; border-bottom: 1px solid #eee;\">System pressure (bar)<\/th>\n<th style=\"text-align: left; padding: 8px; border-bottom: 1px solid #eee;\">213.40<\/th>\n<th style=\"text-align: left; padding: 8px; border-bottom: 1px solid #eee;\">DG-10<\/th>\n<th style=\"text-align: left; padding: 8px; border-bottom: 1px solid #eee;\">Measuring hose DN 2 (max. L) (m)<\/th>\n<th style=\"text-align: left; padding: 8px; border-bottom: 1px solid #eee;\">Capillary (max. L) (m)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">2<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">2.5<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&#8211;<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&#8211;<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">3.2<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">4<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&#8211;<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&#8211;<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">1.0<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">5<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">6<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&#8211;<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">0.5<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">1.0<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">8<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">10<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&#8211;<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">1.0<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">2.0<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">12<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">16<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&#8211;<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">1.0<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">2.0<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">16<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">20<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&#8211;<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u27131)<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">1.5<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">2.0<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">20<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">25<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&#8211;<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">1.5<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">2.0<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">32<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">40<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&#8211;<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">1.5<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">2.0<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">40<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">50<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&#8211;<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">2.0<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">2.0<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">50<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">60<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&#8211;<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">2.0<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">2.0<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">80<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">100<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">2.0<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">2.0<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">120<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">160<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">2.0<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">4.0<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">200<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">250<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">3.2<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">4.0<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">250<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">315<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">&#8211;<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">3.2<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">4.0<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">320<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">400<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">3.2<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">6.0<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">480<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">600<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2713<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">3.2<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">6.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"font-size: 0.9em; margin-top: 8px;\">Other rated loads and versions on request.<br \/>\n1) See original documentation for details.<\/p>\n<p>\uf06e = possible selection<br \/>\n1) Relative linearity error &lt; \u00b11.0 % Fnom<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<section>\n<section>\n<h6>Applications<\/h6>\n<ul>\n<li>Equipment manufacturing<\/li>\n<li>Construction of jigs and fixtures<\/li>\n<li>Special machine building<\/li>\n<li>Measuring and control systems<\/li>\n<\/ul>\n<\/section>\n<section>\n<h6>Special features<\/h6>\n<ul>\n<li>Measuring ranges 0 &#8230; 2 kN to 0 &#8230; 480 kN<\/li>\n<li>Relative linearity error \u00b11.0 &#8230; 1.6 % with analogue pressure gauge, \u00b10.5 % with digital pressure gauge or pressure sensor<br \/>\n(For rated forces below 500 N, the relative linearity error is \u00b11.6 % F<sub>nom<\/sub>\u00a0for all connected measuring instruments.)<\/li>\n<li>Piston stroke \u2264 0.5 mm<\/li>\n<li>Operates without supply voltage<\/li>\n<li>5-year leak-tightness warranty<br \/>\n(Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)<\/li>\n<\/ul>\n<\/section>\n<\/section>\n","protected":false},"featured_media":289524,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5506],"product_cat":[3448],"product_tag":[5037,4938,5508],"class_list":{"0":"post-289527","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-wika","7":"product_cat-force-sensor","8":"product_tag-compression-en","9":"product_tag-transducer","10":"product_tag--en","12":"first","13":"instock","14":"taxable","15":"shipping-taxable","16":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>WIKA \/ Model F1135 Hydraulic compression force transducer - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"Applications   Equipment manufacturing  Construction of jigs and fixtures  Special machine building  Measuring and control systems    Special features   Measuring ranges 0 ... 2 kN to 0 ... 480 kN  Relative linearity error \u00b11.0 ... 1.6 % with analogue pressure gauge, \u00b10.5 % with digital pressure gauge or pressure sensor (For rated forces below 500 N, the relative linearity error is \u00b11.6 % Fnom\u00a0for all connected measuring instruments.)  Piston stroke \u2264 0.5 mm  Operates without supply voltage  5-year leak-tightness warranty (Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/product\/wika-model-f1135-hydraulic-compression-force-transducer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"WIKA \/ Model F1135 Hydraulic compression force transducer\" \/>\n<meta property=\"og:description\" content=\"Applications   Equipment manufacturing  Construction of jigs and fixtures  Special machine building  Measuring and control systems    Special features   Measuring ranges 0 ... 2 kN to 0 ... 480 kN  Relative linearity error \u00b11.0 ... 1.6 % with analogue pressure gauge, \u00b10.5 % with digital pressure gauge or pressure sensor (For rated forces below 500 N, the relative linearity error is \u00b11.6 % Fnom\u00a0for all connected measuring instruments.)  Piston stroke \u2264 0.5 mm  Operates without supply voltage  5-year leak-tightness warranty (Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/product\/wika-model-f1135-hydraulic-compression-force-transducer\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/f1135_en_co_rs_w410_h410_image.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"410\" \/>\n\t<meta property=\"og:image:height\" content=\"410\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1135-hydraulic-compression-force-transducer\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1135-hydraulic-compression-force-transducer\\\/\",\"name\":\"WIKA \\\/ Model F1135 Hydraulic compression force transducer - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1135-hydraulic-compression-force-transducer\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1135-hydraulic-compression-force-transducer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/f1135_en_co_rs_w410_h410_image.jpg\",\"datePublished\":\"2026-02-24T02:17:31+00:00\",\"description\":\"Applications Equipment manufacturing Construction of jigs and fixtures Special machine building Measuring and control systems Special features Measuring ranges 0 ... 2 kN to 0 ... 480 kN Relative linearity error \u00b11.0 ... 1.6 % with analogue pressure gauge, \u00b10.5 % with digital pressure gauge or pressure sensor (For rated forces below 500 N, the relative linearity error is \u00b11.6 % Fnom\u00a0for all connected measuring instruments.) Piston stroke \u2264 0.5 mm Operates without supply voltage 5-year leak-tightness warranty (Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1135-hydraulic-compression-force-transducer\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1135-hydraulic-compression-force-transducer\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1135-hydraulic-compression-force-transducer\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/f1135_en_co_rs_w410_h410_image.jpg\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/f1135_en_co_rs_w410_h410_image.jpg\",\"width\":410,\"height\":410},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/product\\\/wika-model-f1135-hydraulic-compression-force-transducer\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"WIKA \\\/ Model F1135 Hydraulic compression force transducer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/product\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"WIKA \/ Model F1135 Hydraulic compression force transducer - CAS Scale Korea Co., Ltd.","description":"Applications   Equipment manufacturing  Construction of jigs and fixtures  Special machine building  Measuring and control systems    Special features   Measuring ranges 0 ... 2 kN to 0 ... 480 kN  Relative linearity error \u00b11.0 ... 1.6 % with analogue pressure gauge, \u00b10.5 % with digital pressure gauge or pressure sensor (For rated forces below 500 N, the relative linearity error is \u00b11.6 % Fnom\u00a0for all connected measuring instruments.)  Piston stroke \u2264 0.5 mm  Operates without supply voltage  5-year leak-tightness warranty (Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/product\/wika-model-f1135-hydraulic-compression-force-transducer\/","og_locale":"en_US","og_type":"article","og_title":"WIKA \/ Model F1135 Hydraulic compression force transducer","og_description":"Applications   Equipment manufacturing  Construction of jigs and fixtures  Special machine building  Measuring and control systems    Special features   Measuring ranges 0 ... 2 kN to 0 ... 480 kN  Relative linearity error \u00b11.0 ... 1.6 % with analogue pressure gauge, \u00b10.5 % with digital pressure gauge or pressure sensor (For rated forces below 500 N, the relative linearity error is \u00b11.6 % Fnom\u00a0for all connected measuring instruments.)  Piston stroke \u2264 0.5 mm  Operates without supply voltage  5-year leak-tightness warranty (Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)","og_url":"https:\/\/casscale.net\/en\/product\/wika-model-f1135-hydraulic-compression-force-transducer\/","og_site_name":"CAS Scale Korea Co., Ltd.","og_image":[{"width":410,"height":410,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/f1135_en_co_rs_w410_h410_image.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/product\/wika-model-f1135-hydraulic-compression-force-transducer\/","url":"https:\/\/casscale.net\/en\/product\/wika-model-f1135-hydraulic-compression-force-transducer\/","name":"WIKA \/ Model F1135 Hydraulic compression force transducer - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/product\/wika-model-f1135-hydraulic-compression-force-transducer\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/product\/wika-model-f1135-hydraulic-compression-force-transducer\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/f1135_en_co_rs_w410_h410_image.jpg","datePublished":"2026-02-24T02:17:31+00:00","description":"Applications Equipment manufacturing Construction of jigs and fixtures Special machine building Measuring and control systems Special features Measuring ranges 0 ... 2 kN to 0 ... 480 kN Relative linearity error \u00b11.0 ... 1.6 % with analogue pressure gauge, \u00b10.5 % with digital pressure gauge or pressure sensor (For rated forces below 500 N, the relative linearity error is \u00b11.6 % Fnom\u00a0for all connected measuring instruments.) Piston stroke \u2264 0.5 mm Operates without supply voltage 5-year leak-tightness warranty (Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/product\/wika-model-f1135-hydraulic-compression-force-transducer\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/product\/wika-model-f1135-hydraulic-compression-force-transducer\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/product\/wika-model-f1135-hydraulic-compression-force-transducer\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/f1135_en_co_rs_w410_h410_image.jpg","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/f1135_en_co_rs_w410_h410_image.jpg","width":410,"height":410},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/product\/wika-model-f1135-hydraulic-compression-force-transducer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"WIKA \/ Model F1135 Hydraulic compression force transducer"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/product\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/289527","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=289527"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/289524"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=289527"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=289527"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=289527"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=289527"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}