{"id":289667,"date":"2026-02-24T15:50:44","date_gmt":"2026-02-24T06:50:44","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/wika-model-f5802-load-pin\/"},"modified":"2026-02-24T15:50:44","modified_gmt":"2026-02-24T06:50:44","slug":"wika-model-f5802-load-pin","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/wika-model-f5802-load-pin\/","title":{"rendered":"WIKA \/ Model F5802 Load pin"},"content":{"rendered":"<div class=\"column is-half\">\n<h4>Model F5802 Load pin<\/h4>\n<p>Rated force up to 10,000 kN<\/p>\n<div class=\"column is-half\">\n<p>Load pins of the model F5802 are suitable for static and dynamic measuring tasks as a replacement for non-measuring bolts. They serve for determining tension and \/ or compression forces under harsh operating conditions.<\/p>\n<p>The load pins are very often used in hoists and crane systems, e.g. used in construction cranes or in port and offshore cranes, as well as in the field of industrial weighing technology and special machine construction. There they are installed in particular in deflection pulleys, cable winches, fork or roller bearings.<\/p>\n<p>Load pins of this model serve as reliable overload protection in mechanical and plant engineering.<\/p>\n<p>The corresponding technical and regional approvals of these force transducers are, of course, available as options.<\/p>\n<\/div>\n<div class=\"column is-half\">\n<p>The load pins are made of high-strength, corrosion resistant 1.4542 stainless steel, the properties of which are ideal for the application areas.<\/p>\n<p>As output signals, the common active current and voltage outputs are available (4 \u2026 20 mA, 0 \u2026 10 V).<\/p>\n<p>Redundant output signals and CANopen<sup>\u00ae<\/sup>\u00a0protocols are also possible.<\/p>\n<p><strong>Technical data in accordance with VDI\/VDE\/DKD 2638<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"336\"><strong>Model<\/strong><\/td>\n<td width=\"325\"><strong>F5802<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Rated force F<\/strong><strong>nom\u00a0<\/strong><strong>kN [tf]<\/strong><\/td>\n<td width=\"325\">20 &#8230; 10,000 [204 &#8230; 101,972]<\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Relative linearity error d<\/strong><strong>lin\u00a0<\/strong><strong>d<\/strong><strong>lin<\/strong><strong>1)<\/strong><\/td>\n<td width=\"325\">0.5 % &#8230; 1 % Fnom<\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Relative Umkehrspanne v<\/strong><\/td>\n<td width=\"325\">0.5 % &#8230; 1 % Fnom<\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Relative repeatability error in unchanged mounting position b<\/strong><strong>rg<\/strong><\/td>\n<td width=\"325\">0.5 % &#8230; 1 % Fnom<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"661\"><strong>Temperature effect on<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"336\">characteristic value TKC<\/td>\n<td width=\"325\">0.2 % Fnom \/10 K<\/td>\n<\/tr>\n<tr>\n<td width=\"336\">zero signal TK0<\/td>\n<td width=\"325\">0.2 % Fnom \/10 K<\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Force limit F<\/strong><strong>L<\/strong><\/td>\n<td width=\"325\">150 % Fnom<\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Breaking force F<\/strong><strong>B<\/strong><\/td>\n<td width=\"325\">300 % Fnom<\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Material of measuring device<\/strong><\/td>\n<td width=\"325\">Corrosion-resistant stainless steel<\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Rated temperature B<\/strong><strong>T, nom<\/strong><\/td>\n<td width=\"325\">-10 \u2026 +40 \u00b0C [14 &#8230; +104 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Operating temperature B<\/strong><strong>T, G<\/strong><\/td>\n<td width=\"325\">-20 \u2026 +80 \u00b0C [-4 &#8230; +176 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Electrical connection<\/strong><\/td>\n<td width=\"325\">M12 x 1, 4-pin or 5-pin<\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Output signal (rated output) C<\/strong><strong>nom<\/strong><\/td>\n<td width=\"325\">\u25a0 4 \u2026 20 mA, 2-wire <br \/>\n\u25a0 4 \u2026 20 mA, 3-wire <br \/>\n\u25a0 2 x 4 \u2026 20 mA, redundant <br \/>\n\u25a0 DC 0 \u2026 10 V, 3-wire <br \/>\n\u25a0 2 x DC 0 \u2026 10 V redundant <br \/>\n\u25a0 1 &#8230; 2 mV\/V <br \/>\n\u25a0 CANopen\u00ae Protocol in accordance with CiA\u00ae301, device profile CiA\u00ae404, communication services LSS (CiA\u00ae305), configuration of the instrument address and baud rate Sync\/Async, Node\/ Lifeguarding, heartbeat; zero and span \u00b110 % adjustable via entries in the object directory 2)<\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Input resistance R<\/strong><strong>e<\/strong><\/td>\n<td width=\"325\">750 \u00b1 30 \u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Output resistance R<\/strong><strong>a<\/strong><\/td>\n<td width=\"325\">700 \u00b1 5 \u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Isulation resistance R<\/strong><strong>iS<\/strong><\/td>\n<td width=\"325\">\u2265 5,000 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Supply voltage UB<\/strong><\/td>\n<td width=\"325\">\u25a0 DC 9 &#8230; 36 V for current output <br \/>\n\u25a0 DC 13 &#8230; 36 V for voltage output <br \/>\n\u25a0 DC 5 &#8230; 10 V for mV\/V <br \/>\n\u25a0 DC 9 &#8230; 36 V for CANopen\u00ae<\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Ingress protection (acc. to IEC\/EN 60529)<\/strong><\/td>\n<td width=\"325\">IP67<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>1) Relative linearity error accordance with VDI\/VDE\/DKD 2638 chapter 3.2.6.<br \/>\n2) Protocol in accordance with CiA\u00ae301, device profile CiA\u00ae404, communication service LSS (CiA\u00ae305)<br \/>\nCANopen\u00ae and CiA\u00ae are registered community trademarks of CAN\u00ae in Automation e. V.<\/p>\n<p><strong>Dimensions\/mounting situation of the load pin<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-289663\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/2638_2.png\" alt=\"\" width=\"1519\" height=\"646\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/2638_2.png 1519w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/2638_2-800x340.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/2638_2-1400x595.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/2638_2-768x327.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/2638_2-600x255.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/2638_2-64x27.png 64w\" sizes=\"(max-width: 1519px) 100vw, 1519px\" \/><\/p>\n<p>Exemplary illustration.<br \/>\nDimensioning: The customer-specific load pin drawing of the respective order number has priority.<\/p>\n<p><strong>Pin assignment cable<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"3\" width=\"321\"><strong>Electrical connection<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"136\"><strong>Supply voltage +<\/strong><\/td>\n<td width=\"57\">Exc+<\/td>\n<td width=\"128\">Red<\/td>\n<\/tr>\n<tr>\n<td width=\"136\"><strong>Supply voltage &#8211;<\/strong><\/td>\n<td width=\"57\">Exc-<\/td>\n<td width=\"128\">Black<\/td>\n<\/tr>\n<tr>\n<td width=\"136\"><strong>Signal +<\/strong><\/td>\n<td width=\"57\">Sig+<\/td>\n<td width=\"128\">Green<\/td>\n<\/tr>\n<tr>\n<td width=\"136\"><strong>Signal &#8211;<\/strong><\/td>\n<td width=\"57\">Sig-<\/td>\n<td width=\"128\">White<\/td>\n<\/tr>\n<tr>\n<td width=\"136\"><strong>Shield<\/strong><\/td>\n<td width=\"57\">Shield<\/td>\n<td width=\"128\">Yellow-green<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" class=\"alignnone  wp-image-289584\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1811_2.png\" alt=\"\" width=\"437\" height=\"170\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1811_2.png 751w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1811_2-600x233.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F1811_2-64x25.png 64w\" sizes=\"(max-width: 437px) 100vw, 437px\" \/><\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<section>\n<section>\n<section>\n<h6>Applications<\/h6>\n<ul>\n<li>Crane systems and hoists<\/li>\n<li>Industrial weighing technology<\/li>\n<li>Machine building and plant construction<\/li>\n<li>Manufacturing automation<\/li>\n<\/ul>\n<\/section>\n<section>\n<h6>Special features<\/h6>\n<ul>\n<li>Measuring ranges 20 &#8230; 10,000 kN [204 tf &#8230; 101,972 tf]<\/li>\n<li>Corrosion-resistant stainless steel version<\/li>\n<li>Existing non-measuring bolts are simply replaced by the load pins<\/li>\n<li>For overload protection in cranes and hoists<\/li>\n<li>Good reproducibility, easy installation<\/li>\n<\/ul>\n<\/section>\n<\/section>\n<\/section>\n","protected":false},"featured_media":289666,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5506],"product_cat":[5433],"product_tag":[4991],"class_list":{"0":"post-289667","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-wika","7":"product_cat---en","8":"product_tag-pin-load-cell-en","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/289667","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=289667"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/289666"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=289667"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=289667"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=289667"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=289667"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}