{"id":289674,"date":"2026-02-24T16:05:00","date_gmt":"2026-02-24T07:05:00","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/wika-models-f7301-f73c1-f73s1-tension-link\/"},"modified":"2026-02-24T16:21:40","modified_gmt":"2026-02-24T07:21:40","slug":"wika-models-f7301-f73c1-f73s1-tension-link","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/wika-models-f7301-f73c1-f73s1-tension-link\/","title":{"rendered":"WIKA \/ Models F7301, F73C1, F73S1 Tension link"},"content":{"rendered":"<h4>Models F7301, F73C1, F73S1 Tension link<\/h4>\n<p>With thin-film technology from 5 kN<\/p>\n<div class=\"column is-half\">\n<p>Tension links are designed for static and dynamic measurement tasks in the direct flux of force. As a load-bearing component in existing constructions, they determine the tension forces in a wide scope of applications.<\/p>\n<p>Tension links of these models are often used in hoist and crane systems as torque support or rope fix point for load measurements. Further application areas are special machine constructions, e. g. in polymer processing machines.<\/p>\n<p>Appropriate technical and regional approvals are available as an option.<\/p>\n<\/div>\n<div class=\"column is-half\">\n<p>The tension links of the model F73x1 are either made of high-strength, corrosion-resistant stainless steel 1.4542 or robust fine-grained steel with surface protection. Due to their properties, these materials are particularly suitable for the applications of tension links.<\/p>\n<p>As output signals, the common active current and voltage outputs are available (4 &#8230;. 20 mA, 0 &#8230; 10 V).<\/p>\n<p>Redundant output signals and CANopen<sup>\u00ae<\/sup>\u00a0protocols are also possible.<\/p>\n<p>These force transducers can be integrated into a certified WIKA overload protection with model ELMS1 (DIN EN ISO 13849-1 with PL d\/cat. 3).<\/p>\n<p><strong>Technical data in accordance with VDI\/VDE\/DKD 2638<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"204\">Models<\/td>\n<td width=\"257\">F7301 and F73C1 with UL<\/td>\n<td width=\"200\">F73S1<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Rated force Fnom\u00a0kN [lbf]<\/td>\n<td colspan=\"2\" width=\"457\">\u2265 5 [\u2265 1,124]<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Relative linearity error dlin\u00a01)<\/td>\n<td colspan=\"2\" width=\"457\">\u00b10.5 % Fnom<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Relative repeatability error in unchanged mounting position brg<\/td>\n<td colspan=\"2\" width=\"457\">\u00b10.5 % Fnom<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"661\">Temperature effect on<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">characteristic value TKc<\/td>\n<td colspan=\"2\" width=\"457\">0.2 % Fnom\/10 K<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">zero signal TK0<\/td>\n<td colspan=\"2\" width=\"457\">0.2 % Fnom\/10 K<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Force limit FL<\/td>\n<td colspan=\"2\" width=\"457\">150 % Fnom<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Breaking force FB<\/td>\n<td colspan=\"2\" width=\"457\">300 % Fnom<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Shear force influence dQ (Signal with 100 % Fnom\u00a0under 90\u00b0) 2)<\/td>\n<td colspan=\"2\" width=\"457\">\u00b12 % Fnom<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Rated displacement (typ.) snom<\/td>\n<td colspan=\"2\" width=\"457\">&lt; 0.1 mm [&lt; 0.004 in]<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Material of measuring device<\/td>\n<td colspan=\"2\" width=\"457\">\u25a0 Corrosion-resistant stainless steel, 1.4542, ultrasound-tested 3,1 material <br \/>\n\u25a0 Version with 3,2 material available<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Rated temperature BT, nom<\/td>\n<td colspan=\"2\" width=\"457\">-20 \u2026 +80 \u00b0C [-4 &#8230; +176 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Operating temperature BT,\u00a0G<\/td>\n<td width=\"257\">-30 \u2026 +80 \u00b0C [-22 &#8230; +176 \u00b0F]<\/td>\n<td width=\"200\">-30 \u2026 +80 \u00b0C [-22 &#8230; +176 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Storage temperature BT,\u00a0S<\/td>\n<td colspan=\"2\" width=\"457\">-40 \u2026 +85 \u00b0C [-40 &#8230; +185 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Electrical connection<\/td>\n<td width=\"257\">\u25a0 Circular connector M 12 x 1, 4-pin or 5-pin <br \/>\n\u25a0 CANopen\u00ae Circular connector M 12 x 1, 5-pin <br \/>\n\u25a0 MIL connector<\/td>\n<td width=\"200\">\u25a0 2-circular connector M 12&#215;1, 4-pin <br \/>\n\u25a0 MIL connector<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Output signal (rated output) Cnom<\/td>\n<td width=\"257\">\u25a0 4 \u2026 20 mA, 2-wire, <br \/>\n\u25a0 4 \u2026 20 mA, 3-wire <br \/>\n\u25a0 2 x 4 \u2026 20 mA, redundant <br \/>\n\u25a0 DC 0 \u2026 10 V, 3-wire <br \/>\n\u25a0 DC 2 x 0 \u2026 10 V redundant <br \/>\n\u25a0 Signal jump 4 &#8230; 16 mA, 2-wire 5) DC 2 &#8230; 8 V, 3-wire 5) <br \/>\n\u25a0 CANopen\u00ae Protocol in accordance with CiA\u00ae301, device profile CiA\u00ae404, communication services LSS (CiA\u00ae305), configuration of the instrument address and baud rate Sync\/Async, Node\/ Lifeguarding, heartbeat; zero and span \u00b110 % adjustable via entries in the object directory 3)<\/td>\n<td width=\"200\">Redundant opposing 4 \u2026 20 mA\/ 20 \u2026 4 mA Version in accordance with requirements for functional safety per machinery directive 2006\/42\/EC as WIKA overload protection with model ELMS1 (DIN EN ISO 13849-1 with PL d\/cat. 3).<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Current consumption<\/td>\n<td width=\"257\">\u25a0 Current output 4 \u2026 20 mA, 2-wire: signal current <br \/>\n\u25a0 Current output 4 \u2026 20 mA, 3-wire: &lt; 8 mA <br \/>\n\u25a0 Voltage output: &lt; 8 mA <br \/>\n\u25a0 CANopen\u00ae: &lt; 1 W<\/td>\n<td width=\"200\">Current output 4 \u2026 20 mA, 2-wire: signal current<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Supply voltage UB<\/td>\n<td width=\"257\">\u25a0 DC 9 &#8230; 36 V for current output \u25a0 DC 13 &#8230; 36 V for voltage output \u25a0 DC 9 &#8230; 36 V for CANopen\u00ae<\/td>\n<td width=\"200\">DC 10 \u2026 30 V for current output<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Burden<\/td>\n<td width=\"257\">\u25a0 \u2264 (UB \u2013 10 V) \/ 0.024 A for current output <br \/>\n\u25a0 &gt; 10 k\u03a9 for voltage output<\/td>\n<td width=\"200\">\u25a0 \u2264 (UB \u2013 10 V) \/ 0.020 A (channel 1) for current output <br \/>\n\u25a0 \u2264 (UB \u2013 7 V) \/ 0.020 A (channel 2) for current output<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Response time<\/td>\n<td colspan=\"2\" width=\"457\">\u2264 2 ms (within 10 &#8230; 90 % Fnom) 4)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"661\">Protection (per EN\/IEC 60529)<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Unplugged condition<\/td>\n<td width=\"257\">IP66, IP67<\/td>\n<td rowspan=\"2\" width=\"200\">IP67<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Plugged condition<\/td>\n<td width=\"257\">IP68, IP69, IP69K<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Electrical protection<\/td>\n<td colspan=\"2\" width=\"457\">Reverse voltage, overvoltage and short-circuit protection<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Vibration resistance<\/td>\n<td colspan=\"2\" width=\"457\">20 g, 100 h, 50&#8230;150 Hz (acc. to DIN EN 60068-2-6)<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Shock resistance<\/td>\n<td colspan=\"2\" width=\"457\">In accordance with DIN EN 60068-2-27<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Immunity<\/td>\n<td colspan=\"2\" width=\"457\">\u25a0 In accordance with DIN EN 61326-1\/DIN EN 61326-2-3 <br \/>\n\u25a0 EMC-strengthened version<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>1) Relative linearity error is specified in accordance with Directive VDI\/VDE\/DKD 2638 chapter 3.2.6<br \/>\n2) This value can result if 100 % Fnom acts at 90\u00b0 to the axis.<br \/>\n3) Protocol in accordance with CiA\u00ae301, device profile CiA\u00ae404, communication service LSS (CiA\u00ae305)<br \/>\n4) Further reponse times possible on request.<br \/>\n5) Further signal jumps are realisable on request.<br \/>\nCANopen\u00ae and CiA\u00ae are registered community trademarks of CAN\u00ae in Automation e. V.<\/p>\n<p><strong>Technical data in accordance with VDI\/VDE\/DKD 2638<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"204\">Models<\/td>\n<td width=\"457\">F73C1 ATEX\/IECEx EX ib 1)<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Rated force Fnom\u00a0kN [lbf]<\/td>\n<td width=\"457\">\u2265 5 [\u2265 1,124]<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Relative linearity error dlin\u00a02)<\/td>\n<td width=\"457\">\u00b10.5 % Fnom<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Relative repeatability error in unchanged mounting position brg<\/td>\n<td width=\"457\">\u00b10.5 % Fnom<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"661\">Temperature effect on<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">characteristic value TKc<\/td>\n<td width=\"457\">0.2 % Fnom\/10 K<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">zero signal TK0<\/td>\n<td width=\"457\">0.2 % Fnom\/10 K<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Force limit FL<\/td>\n<td width=\"457\">150 % Fnom<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Breaking force FB<\/td>\n<td width=\"457\">300 % Fnom<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Shear force influence dQ (Signal with 100% Fnom\u00a0under 90\u00b0) 3)<\/td>\n<td width=\"457\">\u00b12 % Fnom<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Rated displacement (typ.) snom<\/td>\n<td width=\"457\">&lt; 0.1 mm [&lt; 0.004 in]<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Material of measuring device<\/td>\n<td width=\"457\">\u25a0 Corrosion-resistant stainless steel, 1.4542, ultrasound-tested 3,1 material <br \/>\n\u25a0 Version with 3,2 material available<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Rated temperature BT, nom<\/td>\n<td width=\"457\">-20 \u2026 +80 \u00b0C [-4 &#8230; +176 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Operating temperature BT,\u00a0G<\/td>\n<td width=\"457\">Ex II 2G Ex ib IIC T4 Gb -25 \u00b0C &lt; Tamb &lt; +85 \u00b0C Ex II 2G Ex ib IIC T3 Gb -25 \u00b0C &lt; Tamb &lt; +100 \u00b0C Ex I M2 Ex ib I Mb -25 \u00b0C &lt; Tamb &lt; +85 \u00b0C Ex II 2G Ex ib IIC T4 Gb -40 \u00b0C &lt; Tamb &lt; +85 \u00b0C Ex I M2 Ex ib I Mb<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Storage temperature BT,\u00a0S<\/td>\n<td width=\"457\">-40 \u2026 +85 \u00b0C [-40 &#8230; +185 \u00b0F]<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Electrical connection<\/td>\n<td width=\"457\">\u25a0 Circular connector M 12&#215;1, 4-pin <br \/>\n\u25a0 MIL connector <br \/>\n\u25a0 Cable gland<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Output signal (rated output) Cnom<\/td>\n<td width=\"457\">4 \u2026 20 mA, 2-wire<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Current consumption<\/td>\n<td width=\"457\">Current output 4 \u2026 20 mA 2-wire: signal current<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Supply voltage UB<\/td>\n<td width=\"457\">DC 10 &#8230; 30 V for current output<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Burden<\/td>\n<td width=\"457\">\u25a0 &lt; (UB \u2013 10 V) \/ 0,024 A for current output <br \/>\n\u25a0 &gt; 10 k\u03a9 for voltage output<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Response time<\/td>\n<td width=\"457\">\u2264 2 ms (within 10 &#8230; 90 % Fnom) 4)<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Protection (acc. to EN\/IEC 60529)<\/td>\n<td width=\"457\">IP67<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Electrical protection<\/td>\n<td width=\"457\">Reverse voltage, overvoltage and short-circuit protection<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Shock resistance<\/td>\n<td width=\"457\">20 g, 100 h, 50&#8230;150 Hz acc. to DIN EN 60068-2-6<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Immunity<\/td>\n<td width=\"457\">\u25a0 In accordance with DIN EN 61326-1\/DIN EN 61326-2-3 <br \/>\n\u25a0 EMC-strengthened version<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>1) The load pin with ignition protection type \u201cib\u201d should only be powered using galvanically isolated repeater power supplies.<br \/>\nSuitable repeater power supplies can be offered as an option, e.g. order number: 14255084.<br \/>\n2) Relative linearity error is specified in accordance with Directive VDI\/VDE\/DKD 2638 chapter 3.2.6.<br \/>\n3) This value can result if 100 % Fnom acts at 90\u00b0 to the axis.<br \/>\n4) Further reponse times possible on request.<\/p>\n<p><strong>Dimensions\/Mounting situation<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-289672\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F7301.png\" alt=\"\" width=\"1413\" height=\"480\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F7301.png 1413w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F7301-800x272.png 800w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F7301-1400x476.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F7301-768x261.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F7301-600x204.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F7301-64x22.png 64w\" sizes=\"(max-width: 1413px) 100vw, 1413px\" \/><\/p>\n<p>Dimensions: The customer-specific load pin drawing of the respective order number has priority.<br \/>\nInsert the corresponding bolts into the corresponding holes \uf081 and \uf082 on both sides. Load the tension link with tension force (F).<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<section>\n<h6>Applications<\/h6>\n<ul>\n<li>Crawler cranes, mobile cranes, harbour cranes, for recording load and torque<\/li>\n<li>Conveyor systems<\/li>\n<li>Drives and winches<\/li>\n<li>Cable winch measurement<\/li>\n<li>Ship-lifting facilities<\/li>\n<\/ul>\n<\/section>\n<section>\n<h6>Special features<\/h6>\n<ul>\n<li>Measurement ranges from 0 &#8230; 5 kN [0 &#8230; 1,124 lbf]<\/li>\n<li>Fine-grained structural steel with high-quality surface protection or in corrosion-resistant stainless steel version<\/li>\n<li>High long-term stability, high shock and vibration resistance, excellent reproducibility<\/li>\n<li>For dynamic and static measurements<\/li>\n<li>Redundant output signal is possible<\/li>\n<\/ul>\n<\/section>\n","protected":false},"featured_media":289671,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5506],"product_cat":[3387],"product_tag":[5512],"class_list":{"0":"post-289674","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-wika","7":"product_cat-tension-compression-load-cell","8":"product_tag--en","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/289674","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=289674"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/289671"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=289674"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=289674"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=289674"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=289674"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}