{"id":289765,"date":"2026-02-25T10:10:02","date_gmt":"2026-02-25T01:10:02","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/wika-model-f6804-ring-force-transducer\/"},"modified":"2026-02-25T10:10:02","modified_gmt":"2026-02-25T01:10:02","slug":"wika-model-f6804-ring-force-transducer","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/wika-model-f6804-ring-force-transducer\/","title":{"rendered":"WIKA \/ Model F6804 Ring force transducer"},"content":{"rendered":"<div class=\"column is-half\">\n<h4>Model F6804 Ring force transducer<\/h4>\n<p>For screw forces up to 450 kN<\/p>\n<div class=\"column is-half\">\n<p>The force transducers of the F6804 series are suitable for the measurement of compression forces and are available with nominal loads of 3 kN to 450 kN. This force transducer has been designed with a ring geometry and constructed, specifically, for the measurement of screw and preload forces.<\/p>\n<p>The field of application of this force transducer are applications such as measurement and test equipment in which, for example, screw or bolt forces are measured. In addition, the force on spindle drives or general force can be measured using a ring geometry.<\/p>\n<p>Fields of application include the simple determination of bolt preloads where the force transducer is used as a measuring washer.<\/p>\n<\/div>\n<div class=\"column is-half\">\n<p><strong>Note<\/strong><br \/>\nTo avoid overloading, it is advantageous to connect the force transducer electrically during assembly and to monitor the measured value.<\/p>\n<p>The measuring force must be introduced through the centre and free of transverse force. When assembling the force transducer, care should be taken that the support surface is flat, ground and sufficiently hard.<\/p>\n<p>Due to its small geometry, this force transducer reacts very sensitively to changing or different mounting positions.<\/p>\n<\/div>\n<p><strong>Specifications per VDI\/VDE\/DKD 2638<\/strong><\/p>\n<table>\n<tbody>\n<tr style=\"height: 21px;\">\n<td style=\"height: 21px;\" colspan=\"2\" width=\"661\"><strong>Model F6804<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"height: 21px;\" width=\"255\"><strong>Rated force F<\/strong><strong>nom\u00a0<\/strong><strong>kN<\/strong><\/td>\n<td style=\"height: 21px;\" width=\"406\">3, 5, 10, 20, 50, 100, 150, 200, 300, 450<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"height: 21px;\" width=\"255\"><strong>Relative linearity error d<\/strong><strong>lin<\/strong><\/td>\n<td style=\"height: 21px;\" width=\"406\">2 % Fnom<\/td>\n<\/tr>\n<tr style=\"height: 41px;\">\n<td style=\"height: 41px;\" width=\"255\"><strong>Relative creep, 30 min. at F<\/strong><strong>nom<\/strong><\/td>\n<td style=\"height: 41px;\" width=\"406\">0.5 % Fnom<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"height: 21px;\" width=\"255\"><strong>Relative reversibility error v<\/strong><\/td>\n<td style=\"height: 21px;\" width=\"406\">2 % Fnom<\/td>\n<\/tr>\n<tr style=\"height: 41px;\">\n<td style=\"height: 41px;\" width=\"255\"><strong>Relative span in unchanged mounting situation<\/strong>\u00a0<strong>b<\/strong><strong>rg<\/strong><\/td>\n<td style=\"height: 41px;\" width=\"406\">0.5 % Fnom<\/td>\n<\/tr>\n<tr style=\"height: 41px;\">\n<td style=\"height: 41px;\" width=\"255\"><strong>Relative deviation of zero signal d<\/strong><strong>S, 0<\/strong><\/td>\n<td style=\"height: 41px;\" width=\"406\">\u00b12 % Fnom<\/td>\n<\/tr>\n<tr style=\"height: 41px;\">\n<td style=\"height: 41px;\" width=\"255\"><strong>Temperature effect on the zero signal TK<\/strong><strong>0<\/strong><\/td>\n<td style=\"height: 41px;\" width=\"406\">0.05 % Fnom\/10 \u00b0C<\/td>\n<\/tr>\n<tr style=\"height: 41px;\">\n<td style=\"height: 41px;\" width=\"255\"><strong>Temperature effect on the characteristic value TK<\/strong><strong>C<\/strong><\/td>\n<td style=\"height: 41px;\" width=\"406\">0.05 % Fnom\/10 \u00b0C<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"height: 21px;\" width=\"255\"><strong>Limit force F<\/strong><strong>L<\/strong><\/td>\n<td style=\"height: 21px;\" width=\"406\">150 % Fnom<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"height: 21px;\" width=\"255\"><strong>Breaking force F<\/strong><strong>B<\/strong><\/td>\n<td style=\"height: 21px;\" width=\"406\">200 % Fnom<\/td>\n<\/tr>\n<tr style=\"height: 41px;\">\n<td style=\"height: 41px;\" width=\"255\"><strong>Material of the measuring body<\/strong><\/td>\n<td style=\"height: 41px;\" width=\"406\">Stainless steel<\/td>\n<\/tr>\n<tr style=\"height: 41px;\">\n<td style=\"height: 41px;\" width=\"255\"><strong>Rated temperature range B<\/strong><strong>T, nom<\/strong><\/td>\n<td style=\"height: 41px;\" width=\"406\">-10 \u2026 +60 \u00b0C<\/td>\n<\/tr>\n<tr style=\"height: 41px;\">\n<td style=\"height: 41px;\" width=\"255\"><strong>Service temperature range B<\/strong><strong>T, G<\/strong><\/td>\n<td style=\"height: 41px;\" width=\"406\">-20 \u2026 +80 \u00b0C<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"height: 21px;\" width=\"255\"><strong>Input resistance R<\/strong><strong>e<\/strong><\/td>\n<td style=\"height: 21px;\" width=\"406\">385 \u00b130 \u03a9<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"height: 21px;\" width=\"255\"><strong>Output resistance R<\/strong><strong>a<\/strong><\/td>\n<td style=\"height: 21px;\" width=\"406\">350 \u00b15 \u03a9<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"height: 21px;\" width=\"255\"><strong>Insulation resistance Ris<\/strong><\/td>\n<td style=\"height: 21px;\" width=\"406\">\u2265 5,000 M\u03a9\/DC 100 V<\/td>\n<\/tr>\n<tr style=\"height: 41px;\">\n<td style=\"height: 41px;\" width=\"255\"><strong>Output signal (rated characteristic value) C<\/strong><strong>nom<\/strong><\/td>\n<td style=\"height: 41px;\" width=\"406\">1.0 \u00b110 % mV\/V<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"height: 21px;\" width=\"255\"><strong>Electrical connection<\/strong><\/td>\n<td style=\"height: 21px;\" width=\"406\">Cable \u00d83 \u00d7 3,000 mm<\/td>\n<\/tr>\n<tr style=\"height: 21.6133px;\">\n<td style=\"height: 21.6133px;\" width=\"255\"><strong>Voltage<\/strong>\u00a0<strong>supply<\/strong><\/td>\n<td style=\"height: 21.6133px;\" width=\"406\">DC 5 V (max. 10 V)<\/td>\n<\/tr>\n<tr style=\"height: 41px;\">\n<td style=\"height: 41px;\" width=\"255\"><strong>Ingress protection (per IEC\/EN 60529)<\/strong><\/td>\n<td style=\"height: 41px;\" width=\"406\">IP65<\/td>\n<\/tr>\n<tr style=\"height: 41px;\">\n<td style=\"height: 41px;\" width=\"255\"><strong>Weight<\/strong>\u00a03 kN &#8211; 20 kN 50 kN &#8211; 200 kN 100 kN &#8211; 450 kN<\/td>\n<td style=\"height: 41px;\" width=\"406\">0.1 kg 1.1 kg 1.9 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-289763\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F6804.png\" alt=\"\" width=\"1510\" height=\"1638\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F6804.png 1510w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F6804-369x400.png 369w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F6804-737x800.png 737w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F6804-768x833.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F6804-1416x1536.png 1416w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F6804-600x651.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/02\/F6804-64x69.png 64w\" sizes=\"(max-width: 1510px) 100vw, 1510px\" \/><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<section>\n<section>\n<section>\n<section>\n<section>\n<section>\n<section>\n<section>\n<section>\n<section>\n<section>\n<section>\n<section>\n<section>\n<h6>Applications<\/h6>\n<ul>\n<li>Determining bolt preloads<\/li>\n<li>Measuring and control systems<\/li>\n<li>Testing and production equipment<\/li>\n<li>Press and jointing force measurement<\/li>\n<li>Clamping force measurement and tension force measurement on rods<\/li>\n<\/ul>\n<\/section>\n<section>\n<h6>Special features<\/h6>\n<ul>\n<li>Measuring ranges 0 &#8230; 3 kN to 0 &#8230; 450 kN<\/li>\n<li>Relative linearity error 2 % F<sub>nom<\/sub><\/li>\n<li>Material: Stainless steel<\/li>\n<li>Ingress protection IP65<\/li>\n<\/ul>\n<\/section>\n<\/section>\n<\/section>\n<\/section>\n<\/section>\n<\/section>\n<\/section>\n<\/section>\n<\/section>\n<\/section>\n<\/section>\n<\/section>\n<\/section>\n<\/section>\n","protected":false},"featured_media":289762,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5506],"product_cat":[3448],"product_tag":[5500,5508],"class_list":{"0":"post-289765","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-wika","7":"product_cat-force-sensor","8":"product_tag--en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/289765","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=289765"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/289762"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=289765"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=289765"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=289765"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=289765"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}