{"id":290687,"date":"2026-02-26T15:52:21","date_gmt":"2026-02-26T06:52:21","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/minebea-c2b1b-general-spec-c2b1b-c3-oiml-standard\/"},"modified":"2026-02-26T15:52:21","modified_gmt":"2026-02-26T06:52:21","slug":"minebea-c2b1b-general-spec-c2b1b-c3-oiml-standard","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/minebea-c2b1b-general-spec-c2b1b-c3-oiml-standard\/","title":{"rendered":"MINEBEA \/ C2B1B (General Spec.) \/ C2B1B-C3 (OIML standard)"},"content":{"rendered":"<h4>C2B1B (General Spec.) \/ C2B1B-C3 (OIML standard) Compression Measurement for Industrial Weighing Systems<\/h4>\n<div class=\"section section--page--all s-buttons-block\">\n<div class=\"container\n                            \"><\/p>\n<div class=\"row\">\n<div class=\"col  col--xl--12\"><span style=\"font-size: 22px; font-weight: 600;\">Features<\/span><\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"section section--page--all s-list\">\n<div class=\"container\n                            \"><\/p>\n<div class=\"row\">\n<div class=\"col  col--xl--12\">\n<div class=\"lists\">\n<ul class=\"list\">\n<li>High precision, hermetically sealed all stainless steel load cell<\/li>\n<li>Suitable for the weighing system to floor scale, tank scale and hopper scale<\/li>\n<li>Integrated locker pin for automatic aligning function enables the high precision measurement<\/li>\n<\/ul>\n<p><strong>C2B1B (General Spec.)<\/strong><\/p>\n<div class=\"section section--page--all s-table\">\n<div class=\"container\n                                container--small\n                            \"><\/p>\n<div class=\"row\">\n<div class=\"col  col--xl--12\">\n<table class=\"table table--left-header\">\n<caption>Specifications<\/caption>\n<tbody>\n<tr>\n<td>\n<div class=\"cell\">Rated capacity<\/div>\n<\/td>\n<td>\n<div class=\"cell\">200 kg (1.961 kN) ~ 2 ton (19.61 kN)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Safe overload<\/div>\n<\/td>\n<td>\n<div class=\"cell\">150% R.C.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Ultimate overload<\/div>\n<\/td>\n<td>\n<div class=\"cell\">200% R.C.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Rated output<\/div>\n<\/td>\n<td>\n<div class=\"cell\">2 mV\/V\u00b10.002 mV\/V (C2B1B-200K: 1.6 mV\/V\u00b10.002 mV\/V)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Non-linearity<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.025% R.O.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Hysteresis<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.025% R.O.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Repeatability<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.025% R.O.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Creep<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.03% R.O.\/30 min<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Creep recovery<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.03% R.O.\/30 min<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Excitation, recommended<\/div>\n<\/td>\n<td>\n<div class=\"cell\">12 V or less<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Excitation, maximum<\/div>\n<\/td>\n<td>\n<div class=\"cell\">20 V<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Zero balance<\/div>\n<\/td>\n<td>\n<div class=\"cell\">\u00b10.02 mV\/V<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Input resistance<\/div>\n<\/td>\n<td>\n<div class=\"cell\">380 \u03a9 ~ 460 \u03a9<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Output resistance<\/div>\n<\/td>\n<td>\n<div class=\"cell\">345 \u03a9 ~ 355 \u03a9<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Insulation resistance<\/div>\n<\/td>\n<td>\n<div class=\"cell\">2,000 M\u03a9 or more (DC50 V) (between bridge and main body)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Temp. range, compensated<\/div>\n<\/td>\n<td>\n<div class=\"cell\">-10 \u2103 ~ 70 \u2103<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Temp. range, safe<\/div>\n<\/td>\n<td>\n<div class=\"cell\">-20 \u2103 ~ 80 \u2103<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Temp. effect on zero<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.05% R.O.\/10 \u2103<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Temp. effect on output<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.02% LOAD\/10 \u2103<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Cable<\/div>\n<\/td>\n<td>\n<div class=\"cell\">\u03c64.7, 4-cores shielded 6 m cable directly attached with Y-type crimp terminal lugs at cable end<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Class of protection<\/div>\n<\/td>\n<td>\n<div class=\"cell\">IP68 or equivalent<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Material of element<\/div>\n<\/td>\n<td>\n<div class=\"cell\">Stainless steel<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Durability<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1,000,000 times with rated load applied<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"section section--page--all s-table\">\n<div class=\"container\n                                container--small\n                            \"><\/p>\n<div class=\"row\">\n<div class=\"col  col--xl--12\">\n<table class=\"table table--left-header\">\n<caption>List of Part Numbers<\/caption>\n<thead>\n<tr>\n<th>\n<div class=\"cell\">Part Number<\/div>\n<\/th>\n<th>\n<div class=\"cell\">Rated Capacity<\/div>\n<\/th>\n<th>\n<div class=\"cell\">Natural Frequency<\/div>\n<\/th>\n<th>\n<div class=\"cell\">Rated Displacement<\/div>\n<\/th>\n<th>\n<div class=\"cell\">Weight (Approx.)<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\n<div class=\"cell\">C2B1B-200K<\/div>\n<\/td>\n<td>\n<div class=\"cell\">200 kg (1.961 kN)<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1,000 Hz<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.15 mm<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.8 kg<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">C2B1B-250K<\/div>\n<\/td>\n<td>\n<div class=\"cell\">250 kg (2.452 kN)<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1,000 Hz<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.15 mm<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.8 kg<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">C2B1B-500K<\/div>\n<\/td>\n<td>\n<div class=\"cell\">500 kg (4.903 kN)<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1,000 Hz<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.2 mm<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.8 kg<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">C2B1B-1T<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1 t (9.807 kN)<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1,000 Hz<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.3 mm<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.8 kg<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">C2B1B-2T<\/div>\n<\/td>\n<td>\n<div class=\"cell\">2 ton (19.61 kN)<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1,500 Hz<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.5 mm<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1.5 kg<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p><strong>C2B1B-C3 (OIML standard)<\/strong><\/p>\n<div class=\"section section--page--all s-table\">\n<div class=\"container\n                                container--small\n                            \"><\/p>\n<div class=\"row\">\n<div class=\"col  col--xl--12\">\n<table class=\"table table--left-header\">\n<caption>Specifications<\/caption>\n<tbody>\n<tr>\n<td>\n<div class=\"cell\">OIML Accuracy class<\/div>\n<\/td>\n<td>\n<div class=\"cell\">OIML R60 C3<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Maximum scale interval<\/div>\n<\/td>\n<td>\n<div class=\"cell\">3,000<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Rated capacity<\/div>\n<\/td>\n<td>\n<div class=\"cell\">200 kg ~ 2 T<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Minimum detected scale (Vmin)<\/div>\n<\/td>\n<td>\n<div class=\"cell\">20 g ~ 200 g<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Safe overload<\/div>\n<\/td>\n<td>\n<div class=\"cell\">150% R.C.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Ultimate overload<\/div>\n<\/td>\n<td>\n<div class=\"cell\">200% R.C.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Rated output<\/div>\n<\/td>\n<td>\n<div class=\"cell\">2 mV\/V\u00b10.002 mV\/V (C2B1B-200K-C3: 1.6 mV\/V\u00b10.002 mV\/V)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Non-linearity<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.023% R.O.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Hysteresis<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.023% R.O.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Repeatability<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.010% R.O.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Creep<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.016% R.O.\/30 min<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Creep recovery<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.016% R.O.\/30 min<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Excitation, recommended<\/div>\n<\/td>\n<td>\n<div class=\"cell\">12 V or less<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Excitation, maximum<\/div>\n<\/td>\n<td>\n<div class=\"cell\">20 V<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Zero balance<\/div>\n<\/td>\n<td>\n<div class=\"cell\">\u00b10.02 mV\/V<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Input resistance<\/div>\n<\/td>\n<td>\n<div class=\"cell\">380 \u03a9 ~ 460 \u03a9<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Output resistance<\/div>\n<\/td>\n<td>\n<div class=\"cell\">345 \u03a9 ~ 355 \u03a9<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Insulation resistance<\/div>\n<\/td>\n<td>\n<div class=\"cell\">2,000 M\u03a9 or more (DC50 V) (between bridge and main body)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Temp. range, compensated<\/div>\n<\/td>\n<td>\n<div class=\"cell\">-10 \u2103 ~ 40 \u2103<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Temp. range, safe<\/div>\n<\/td>\n<td>\n<div class=\"cell\">-20 \u2103 ~ 80 \u2103<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Temp. effect on zero balance<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.014% R.O.\/10 \u2103<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Temp. effect on output<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.012% LOAD\/10 \u2103<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Cable<\/div>\n<\/td>\n<td>\n<div class=\"cell\">\u03c64.7, 4-cores shielded 6m cable directly attached with Y-type crimp terminal lugs at cable end<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Class of protection<\/div>\n<\/td>\n<td>\n<div class=\"cell\">IP68 or equivalent<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Material of element<\/div>\n<\/td>\n<td>\n<div class=\"cell\">Stainless steel<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Weight<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.8 kg (C2B1B-2T-C3: 1.5 kg)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Durability<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1,000,000 times with rated load applied<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"section section--page--all s-table\">\n<div class=\"container\n                                container--small\n                            \"><\/p>\n<div class=\"row\">\n<div class=\"col  col--xl--12\">\n<table class=\"table table--left-header\">\n<caption>List of Part Numbers<\/caption>\n<thead>\n<tr>\n<th>\n<div class=\"cell\">Part Number<\/div>\n<\/th>\n<th>\n<div class=\"cell\">Rated Capacity<\/div>\n<\/th>\n<th>\n<div class=\"cell\">Minimum Detected Scale (Vmin)<\/div>\n<\/th>\n<th>\n<div class=\"cell\">Natural Frequency<\/div>\n<\/th>\n<th>\n<div class=\"cell\">Rated Displacement<\/div>\n<\/th>\n<th>\n<div class=\"cell\">Weight (Approx.)<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\n<div class=\"cell\">C2B1B-200K-C3<\/div>\n<\/td>\n<td>\n<div class=\"cell\">200 kg<\/div>\n<\/td>\n<td>\n<div class=\"cell\">20 g<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1,000 Hz<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.15 mm<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.8 kg<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">C2B1B-250K-C3<\/div>\n<\/td>\n<td>\n<div class=\"cell\">250 kg<\/div>\n<\/td>\n<td>\n<div class=\"cell\">25 g<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1,000 Hz<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.15 mm<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.8 kg<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">C2B1B-500K-C3<\/div>\n<\/td>\n<td>\n<div class=\"cell\">500 kg<\/div>\n<\/td>\n<td>\n<div class=\"cell\">50 g<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1,000 Hz<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.2 mm<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.8 kg<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">C2B1B-1T-C3<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1 t<\/div>\n<\/td>\n<td>\n<div class=\"cell\">100 g<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1,000 Hz<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.3 mm<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.8 kg<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">C2B1B-2T-C3<\/div>\n<\/td>\n<td>\n<div class=\"cell\">2 t<\/div>\n<\/td>\n<td>\n<div class=\"cell\">200 g<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1,500 Hz<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.5 mm<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1.5 kg<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"section section--page--all s-table\">\n<div class=\"container\n                                container--small\n                            \"><\/p>\n<div class=\"row\">\n<div class=\"col  col--xl--12\">\n<div class=\"section section--page--all s-table\">\n<div class=\"container\n                                container--small\n                            \"><\/p>\n<div class=\"row\">\u00a0<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>C2B1B (General Spec.) \/ C2B1B-C3 (OIML standard) Compression Measurement for Industrial Weighing Systems Features High precision, hermetically sealed all stainless steel load cell Suitable for the weighing system to floor scale, tank scale and hopper scale Integrated locker pin for automatic aligning function enables the high precision measurement C2B1B (General Spec.) Specifications Rated capacity 200 [&hellip;]<\/p>\n","protected":false},"featured_media":290686,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5531],"product_cat":[3383],"product_tag":[4528,5037],"class_list":{"0":"post-290687","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-minebeamitsumi","7":"product_cat-beam-type-load-cell","8":"product_tag-beam-type","9":"product_tag-compression-en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/290687","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=290687"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/290686"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=290687"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=290687"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=290687"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=290687"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}