{"id":290934,"date":"2026-02-27T12:57:17","date_gmt":"2026-02-27T03:57:17","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/minebea-pro-series\/"},"modified":"2026-02-27T12:57:17","modified_gmt":"2026-02-27T03:57:17","slug":"minebea-pro-series","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/minebea-pro-series\/","title":{"rendered":"MINEBEA \/ PRO Series"},"content":{"rendered":"<h4 class=\"title title--bold mb-4 \">PRO Series Strain Gauge-Type Pressure Transducer<\/h4>\n<p><span style=\"font-weight: 600;\">Features<\/span><\/p>\n<div class=\"section section--page--all s-list\">\n<div class=\"container \">\n<div class=\"row\">\n<div class=\"col col--xl--12\">\n<div class=\"lists\">\n<ul class=\"list\">\n<li>Compact and light weight \u03c615 mm x 33 mm, Approx. 25 g<\/li>\n<li>Compact flash diaphragm type (Bolt shape)<\/li>\n<li>High response, and no need to pulling out in the pressure inlet.<\/li>\n<\/ul>\n<h6 class=\"title title--medium-blue\">Applications<\/h6>\n<ul class=\"list\">\n<li>Industrial machines that measure pressure<\/li>\n<li>Hydraulic brake and air compressor testing<\/li>\n<\/ul>\n<\/div>\n<table class=\"table table--left-header\">\n<caption>Specifications<\/caption>\n<tbody>\n<tr>\n<td>\n<div class=\"cell\">Rated capacity<\/div>\n<\/td>\n<td>\n<div class=\"cell\">2 MPa~20 MPa<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Safe overload<\/div>\n<\/td>\n<td>\n<div class=\"cell\">150% R.C.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Ultimate overload<\/div>\n<\/td>\n<td>\n<div class=\"cell\">200% R.C.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Rated output<\/div>\n<\/td>\n<td>\n<div class=\"cell\">\u00b11.0 mV\/V\u00b10.3 mV\/V<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Non-linearity<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.5% R.O.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Hysteresis<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.5% R.O.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Excitation, recommended<\/div>\n<\/td>\n<td>\n<div class=\"cell\">DC 1.5 V \/ AC 2.0 V<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Excitation, maximum<\/div>\n<\/td>\n<td>\n<div class=\"cell\">DC 3 V<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Zero balance<\/div>\n<\/td>\n<td>\n<div class=\"cell\">\u00b11.6 mV\/V<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Input resistance<\/div>\n<\/td>\n<td>\n<div class=\"cell\">350 \u03a9 \u00b140 \u03a9<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Output resistance<\/div>\n<\/td>\n<td>\n<div class=\"cell\">350 \u03a9 \u00b140 \u03a9<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Insulation resistance<\/div>\n<\/td>\n<td>\n<div class=\"cell\">1,000 M\u03a9 or more (DC 50 V) (between bridge and main body)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Temp. range, compensated<\/div>\n<\/td>\n<td>\n<div class=\"cell\">-30 \u2103 ~ 150 \u2103<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Temp. range, safe<\/div>\n<\/td>\n<td>\n<div class=\"cell\">-40 \u2103 ~ 160 \u2103<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Temp. effect on zero<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.8% R.O.\/10 \u2103<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Temp. effect on output<\/div>\n<\/td>\n<td>\n<div class=\"cell\">0.8% LOAD\/10 \u2103<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Cable<\/div>\n<\/td>\n<td>\n<div class=\"cell\">\u03c63.8, 4-cores 30cm cable directly attached<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Class of protection<\/div>\n<\/td>\n<td>\n<div class=\"cell\">IP64 or equivalent<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Material of element<\/div>\n<\/td>\n<td>\n<div class=\"cell\">Stainless steel<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Mounting screw<\/div>\n<\/td>\n<td>\n<div class=\"cell\">M10 x P1.0<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"cell\">Weight<\/div>\n<\/td>\n<td>\n<div class=\"cell\">Approx. 25 g<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>PRO Series Strain Gauge-Type Pressure Transducer Features Compact and light weight \u03c615 mm x 33 mm, Approx. 25 g Compact flash diaphragm type (Bolt shape) High response, and no need to pulling out in the pressure inlet. Applications Industrial machines that measure pressure Hydraulic brake and air compressor testing Specifications Rated capacity 2 MPa~20 MPa [&hellip;]<\/p>\n","protected":false},"featured_media":290933,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5449,5531],"product_cat":[5418],"product_tag":[4642],"class_list":{"0":"post-290934","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-minebea-intec","7":"product_brand-minebeamitsumi","8":"product_cat--en","9":"product_tag-pressure-sensor","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/290934","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=290934"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/290933"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=290934"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=290934"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=290934"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=290934"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}