{"id":293939,"date":"2026-03-05T11:24:57","date_gmt":"2026-03-05T02:24:57","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/tedea-huntleigh-model-220-heavy-duty-compression-load-cell\/"},"modified":"2026-03-05T16:14:05","modified_gmt":"2026-03-05T07:14:05","slug":"tedea-huntleigh-model-220-heavy-duty-compression-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/tedea-huntleigh-model-220-heavy-duty-compression-load-cell\/","title":{"rendered":"Tedea Huntleigh \/ Model 220 Heavy Duty Compression Load Cell"},"content":{"rendered":"<h2>Model 220 Heavy Duty Compression Load Cell<\/h2>\n<p><strong>FEATURES<\/strong><br \/>\n\u2022 Capacities 5\u201350 t<br \/>\n\u2022 Stainless steel construction<br \/>\n\u2022 OIML R60 and NTEP approved<br \/>\n\u2022 IP68 protection<br \/>\n\u2022 Optional<br \/>\n\u2022 EEx ia IIC T6 hazardous area approval<br \/>\n\u2022 FM approval available<br \/>\n<strong>APPLICATIONS<\/strong><br \/>\n\u2022 Truck scales<br \/>\n\u2022 Hopper for process weighing<br \/>\n\u2022 Tank and silo weighing<br \/>\n\u2022 Harsh environment<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-293935\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/220.png\" alt=\"\" width=\"1272\" height=\"842\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/220.png 1272w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/220-604x400.png 604w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/220-1209x800.png 1209w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/220-768x508.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/220-285x190.png 285w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/220-600x397.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/220-64x42.png 64w\" sizes=\"(max-width: 1272px) 100vw, 1272px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"6\" width=\"650\">SPECIFICATIONS<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">PARAMETER<\/td>\n<td colspan=\"4\" width=\"329\">VALUE<\/td>\n<td width=\"129\">UNIT<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Rated capacity\u2014R.C. (Emax)<\/td>\n<td colspan=\"4\" width=\"329\">5000, 10000, 20000, 30000, 50000***<\/td>\n<td width=\"129\">kg<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">NTEP\/OIML accuracy class<\/td>\n<td width=\"82\">NTEP<\/td>\n<td width=\"82\">C1<\/td>\n<td width=\"82\">C3*<\/td>\n<td width=\"82\">C4**<\/td>\n<td width=\"129\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Maximum no. of intervals (n)<\/td>\n<td width=\"82\">10000 IIIL multiple<\/td>\n<td width=\"82\">1000<\/td>\n<td width=\"82\">3000<\/td>\n<td width=\"82\">4000<\/td>\n<td width=\"129\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Y = Emax\/Vmin<\/td>\n<td width=\"82\">11000<\/td>\n<td width=\"82\">5000<\/td>\n<td width=\"82\">14000<\/td>\n<td width=\"82\">14000<\/td>\n<td width=\"129\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Rated output\u2014R.O.<\/td>\n<td colspan=\"4\" width=\"329\">2.0<\/td>\n<td width=\"129\">mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Rated output tolerance<\/td>\n<td colspan=\"4\" width=\"329\">0.1<\/td>\n<td width=\"129\">\u00b1% of rated output<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Zero balance<\/td>\n<td colspan=\"4\" width=\"329\">2<\/td>\n<td width=\"129\">\u00b1% of rated output<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Zero return, 30 min.<\/td>\n<td width=\"82\">0.0330<\/td>\n<td width=\"82\">0.0500<\/td>\n<td width=\"82\">0.0170<\/td>\n<td width=\"82\">0.0125<\/td>\n<td width=\"129\">\u00b1% of applied load<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Total error (per OIMP R60)<\/td>\n<td width=\"82\">0.0200<\/td>\n<td width=\"82\">0.0500<\/td>\n<td width=\"82\">0.0200<\/td>\n<td width=\"82\">0.0150<\/td>\n<td width=\"129\">\u00b1% of rated output<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Temperature effect on zero<\/td>\n<td width=\"82\">0.0023<\/td>\n<td width=\"82\">0.0028<\/td>\n<td width=\"82\">0.0010<\/td>\n<td width=\"82\">0.0010<\/td>\n<td width=\"129\">\u00b1% of rated output\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Temperature effect on output<\/td>\n<td width=\"82\">0.001<\/td>\n<td width=\"82\">0.0020<\/td>\n<td width=\"82\">0.0010<\/td>\n<td width=\"82\">0.0008<\/td>\n<td width=\"129\">\u00b1% of applied load\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Temperature range, compensated<\/td>\n<td colspan=\"4\" width=\"329\">\u201310 to +40<\/td>\n<td width=\"129\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Temperature range, safe<\/td>\n<td colspan=\"4\" width=\"329\">\u201330 to +70<\/td>\n<td width=\"129\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Maximum safe central overload<\/td>\n<td colspan=\"4\" width=\"329\">150<\/td>\n<td width=\"129\">% of R.C.<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Ultimate central overload<\/td>\n<td colspan=\"4\" width=\"329\">300<\/td>\n<td width=\"129\">% of R.C.<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Excitation, recommended<\/td>\n<td colspan=\"4\" width=\"329\">10<\/td>\n<td width=\"129\">VDC or VAC RMS<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Excitation, maximum<\/td>\n<td colspan=\"4\" width=\"329\">20<\/td>\n<td width=\"129\">VDC or VAC RMS<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Input impedance<\/td>\n<td colspan=\"4\" width=\"329\">1065\u00b160<\/td>\n<td width=\"129\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Output impedance<\/td>\n<td colspan=\"4\" width=\"329\">1025\u00b120<\/td>\n<td width=\"129\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Insulation resistance<\/td>\n<td colspan=\"4\" width=\"329\">&gt;2000<\/td>\n<td width=\"129\">M\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Cable length<\/td>\n<td colspan=\"4\" width=\"329\">5 m (5 t), 10 m (10 and 20 t), 20 m (30 and 50 t)<\/td>\n<td width=\"129\">m<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Cable type<\/td>\n<td colspan=\"4\" width=\"329\">6-wire, braided, polyurethane, double loating screen<\/td>\n<td width=\"129\">Standard<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Construction<\/td>\n<td colspan=\"4\" width=\"329\">Stainless Steel<\/td>\n<td width=\"129\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"191\">Environmental protection<\/td>\n<td colspan=\"4\" width=\"329\">IP68<\/td>\n<td width=\"129\">\u00a0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* 20% utilization<br \/>\n** 40% utilization<br \/>\n*** Capacities 5\u201320 t available in C6 45% utilization<br \/>\nAll speciications subject to change without notice.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-293937\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/220-1.png\" alt=\"\" width=\"457\" height=\"317\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/220-1.png 457w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/220-1-64x44.png 64w\" sizes=\"(max-width: 457px) 100vw, 457px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The load cell model 220 is a stainless steel, low profile bending ring load cell, designed for high capacity weighing applications, including, hopper, tanks, silos, weighbridges, etc. Its high accuracy and low cost combined with its small dimension makes this load cell well suited for modern low-profile designs in both approved applications and process weighing. The 220 is OIML R60 approved to 6000 divisions. For hazardous environments the load cell is available in an EEx ia IIC T6 level approved version.<\/p>\n","protected":false},"featured_media":293934,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5571,5572],"product_cat":[3387],"product_tag":[4646],"class_list":{"0":"post-293939","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-tedea-huntleigh","7":"product_brand-vpgforcesensors","8":"product_cat-tension-compression-load-cell","9":"product_tag-compression-load-cell-en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/293939","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=293939"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/293934"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=293939"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=293939"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=293939"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=293939"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}