{"id":293995,"date":"2026-03-05T13:21:30","date_gmt":"2026-03-05T04:21:30","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/vpg-model-1022-single-point-aluminum-load-cell\/"},"modified":"2026-03-05T16:12:22","modified_gmt":"2026-03-05T07:12:22","slug":"vpg-model-1022-single-point-aluminum-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/vpg-model-1022-single-point-aluminum-load-cell\/","title":{"rendered":"Tedea Huntleigh \/ Model 1022 Single-Point Aluminum Load Cell"},"content":{"rendered":"<h2>Model 1022 Single-Point Aluminum Load Cell<\/h2>\n<p><strong>FEATURES<\/strong><br \/>\n\u2022 Capacities: 3\u2013200 kg<br \/>\n\u2022 Only 22 mm high<br \/>\n\u2022 Aluminum construction<br \/>\n\u2022 Single-point 350 x 350 mm platform<br \/>\n\u2022 IP66 protection<br \/>\n\u2022 OIML R60 and NTEP approved<br \/>\n\u2022 Optional<br \/>\n\u274d ATEX, FM and IECEx approvals available<br \/>\n\u274d Symmetric coniguration available<\/p>\n<p><strong>APPLICATIONS<\/strong><br \/>\n\u2022 Bench scales<br \/>\n\u2022 Counting scales<br \/>\n\u2022 Grocery scales<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-293993\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1022.png\" alt=\"\" width=\"1423\" height=\"863\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1022.png 1423w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1022-660x400.png 660w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1022-1319x800.png 1319w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1022-768x466.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1022-495x300.png 495w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1022-600x364.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1022-64x39.png 64w\" sizes=\"(max-width: 1423px) 100vw, 1423px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"6\" width=\"648\">SPECIFICATIONS<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">PARAMETER<\/td>\n<td colspan=\"4\" width=\"303\">VALUE<\/td>\n<td width=\"141\">UNIT<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Rated capacity\u2014R.C. (Emax)<\/td>\n<td colspan=\"4\" width=\"303\">3, 5, 7, 10, 15, 20, 30, 35, 50, 100, 150, 200***<\/td>\n<td width=\"141\">kg<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">NTEP\/OIML accuracy class<\/td>\n<td width=\"74\">NTEP<\/td>\n<td width=\"86\">Non-Approved<\/td>\n<td width=\"72\">C3*<\/td>\n<td width=\"72\">C4<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Maximum no. of intervals (n)<\/td>\n<td width=\"74\">5000 single**<\/td>\n<td width=\"86\">1000<\/td>\n<td width=\"72\">3000<\/td>\n<td width=\"72\">4000<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Y = Emax\/Vmin<\/td>\n<td width=\"74\">10000<\/td>\n<td width=\"86\">1400<\/td>\n<td width=\"72\">6000<\/td>\n<td width=\"72\">10000<\/td>\n<td width=\"141\">Maximum available 12000<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Rated output\u2014R.O.<\/td>\n<td colspan=\"4\" width=\"303\">2.0<\/td>\n<td width=\"141\">mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Rated output tolerance<\/td>\n<td colspan=\"4\" width=\"303\">0.2<\/td>\n<td width=\"141\">\u00b1mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Zero balance<\/td>\n<td colspan=\"4\" width=\"303\">0.1<\/td>\n<td width=\"141\">\u00b1mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Zero return, 30 min.<\/td>\n<td width=\"74\">0.01<\/td>\n<td width=\"86\">0.05<\/td>\n<td width=\"72\">0.0170<\/td>\n<td width=\"72\">0.0125<\/td>\n<td width=\"141\">\u00b1% of applied load<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Total error (per OIML R60)<\/td>\n<td width=\"74\">0.0200<\/td>\n<td width=\"86\">0.03<\/td>\n<td width=\"72\">0.0200<\/td>\n<td width=\"72\">0.0150<\/td>\n<td width=\"141\">\u00b1% of rated output<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Temperature effect on zero<\/td>\n<td width=\"74\">0.0014<\/td>\n<td width=\"86\">0.0100<\/td>\n<td width=\"72\">0.0023<\/td>\n<td width=\"72\">0.0014<\/td>\n<td width=\"141\">\u00b1% of rated output\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Temperature effect on output<\/td>\n<td width=\"74\">0.0010<\/td>\n<td width=\"86\">0.0030<\/td>\n<td width=\"72\">0.0010<\/td>\n<td width=\"72\">0.00075<\/td>\n<td width=\"141\">\u00b1% of rated output\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Eccentric loading error<\/td>\n<td width=\"74\">0.0057<\/td>\n<td width=\"86\">0.0085<\/td>\n<td width=\"72\">0.0057<\/td>\n<td width=\"72\">0.0042<\/td>\n<td width=\"141\">\u00b1% of rated load\/cm<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Temperature range, compensated<\/td>\n<td colspan=\"4\" width=\"303\">\u201310 to +40<\/td>\n<td width=\"141\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Temperature range, safe<\/td>\n<td colspan=\"4\" width=\"303\">\u201330 to +70<\/td>\n<td width=\"141\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Maximum safe central overload<\/td>\n<td colspan=\"4\" width=\"303\">150<\/td>\n<td width=\"141\">% of R.C.<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Ultimate central overload<\/td>\n<td colspan=\"4\" width=\"303\">300<\/td>\n<td width=\"141\">% of R.C.<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Excitation, recommended<\/td>\n<td colspan=\"4\" width=\"303\">10<\/td>\n<td width=\"141\">VDC or VAC RMS<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Excitation, maximum<\/td>\n<td colspan=\"4\" width=\"303\">15<\/td>\n<td width=\"141\">VDC or VAC RMS<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Input impedance<\/td>\n<td colspan=\"4\" width=\"303\">415\u00b115<\/td>\n<td width=\"141\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Output impedance<\/td>\n<td colspan=\"4\" width=\"303\">350\u00b13<\/td>\n<td width=\"141\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Insulation resistance<\/td>\n<td colspan=\"4\" width=\"303\">&gt;2000<\/td>\n<td width=\"141\">M\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Cable length<\/td>\n<td colspan=\"4\" width=\"303\">0.5, other lengths available<\/td>\n<td width=\"141\">m<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Cable type<\/td>\n<td colspan=\"4\" width=\"303\">4 or 6 wire, PVC, single loating screen or grounded to element body<\/td>\n<td width=\"141\">Standard<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Construction<\/td>\n<td colspan=\"4\" width=\"303\">Aluminum<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Environmental protection<\/td>\n<td colspan=\"4\" width=\"303\">IP66<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Platform size (max.)<\/td>\n<td colspan=\"4\" width=\"303\">350 \u00d7 350<\/td>\n<td width=\"141\">mm<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Recommended torque<\/td>\n<td colspan=\"4\" width=\"303\">Up to 30 kg: 7.0 35 kg and up: 10.0<\/td>\n<td width=\"141\">N*m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* 50% utilization<br \/>\n** Also available at 50% utilization<br \/>\n*** 150\u2013200 kg are not approved by NTEP, 200 kg is not approved by OIML<\/p>\n<p>All speciications subject to change without notice.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-293971\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/616-1.png\" alt=\"\" width=\"472\" height=\"360\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/616-1.png 472w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/616-1-64x49.png 64w\" sizes=\"(max-width: 472px) 100vw, 472px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The aluminum single-point load cell model 1022 is designed for direct mounting of low-cost weighing platforms. Its small physical size, combined with high accuracy and low profile makes this low-cost load cell well suited for retail, bench scales and counting scales. OIML R60 approved to 4000d from 3-150 kg and OIML R60 approved to 6000d from 20-150 kg, while NTEP 5000d from 3 to 100 kg. Available in the capacities 3-200 kg. Environmental protection to IP66 is provided as standard. For hazardous environments the load cell is available in EEx ia IIC T4 and EX ia IIIC T135\u00b0C approved versions.<\/p>\n","protected":false},"featured_media":293992,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5571,5572],"product_cat":[3385],"product_tag":[5070],"class_list":{"0":"post-293995","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-tedea-huntleigh","7":"product_brand-vpgforcesensors","8":"product_cat-single-point-en","9":"product_tag---en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/293995","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=293995"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/293992"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=293995"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=293995"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=293995"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=293995"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}