{"id":294039,"date":"2026-03-05T13:52:52","date_gmt":"2026-03-05T04:52:52","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/vpg-model-1250-aluminum-high-capacity-single-point-load-cell\/"},"modified":"2026-03-05T16:10:33","modified_gmt":"2026-03-05T07:10:33","slug":"vpg-model-1250-aluminum-high-capacity-single-point-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/vpg-model-1250-aluminum-high-capacity-single-point-load-cell\/","title":{"rendered":"Tedea Huntleigh \/ Model 1250 Aluminum High Capacity Single-Point Load Cell"},"content":{"rendered":"<h2>Model 1250 Aluminum High Capacity Single-Point Load Cell<\/h2>\n<p><strong>FEATURES<\/strong><br \/>\n\u2022 Capacities 50\u20131500 kg<br \/>\n\u2022 Aluminum construction<br \/>\n\u2022 Single-point 800 x 800 mm platform<br \/>\n\u2022 OIML R60 and NTEP approved<br \/>\n\u2022 IP65 protection<br \/>\n\u2022 Available with metric and UNC threads<br \/>\n\u2022 Optional<br \/>\n\u274d EEx ia IIC T4 hazardous area approval<br \/>\n\u274d FM approval available<br \/>\n\u274d IP67 option available<\/p>\n<p><strong>APPLICATIONS<\/strong><br \/>\n\u2022 Large platform scales<br \/>\n\u2022 Hanging scales<br \/>\n\u2022 Check weighing<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-294037\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1250.png\" alt=\"\" width=\"1428\" height=\"797\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1250.png 1428w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1250-717x400.png 717w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1250-1400x781.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1250-768x429.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1250-600x335.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1250-64x36.png 64w\" sizes=\"(max-width: 1428px) 100vw, 1428px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"5\" width=\"649\">SPECIFICATIONS<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">PARAMETER<\/td>\n<td colspan=\"3\" width=\"316\">VALUE<\/td>\n<td width=\"143\">UNIT<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Rated capacity\u2014R.C. (Emax)<\/td>\n<td colspan=\"3\" width=\"316\">50, 75, 100 , 150, 200, 250, 300, 500, 635, 750, 1000, 1500<\/td>\n<td width=\"143\">kg<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">NTEP\/OIML accuracy class<\/td>\n<td width=\"105\">NTEP<\/td>\n<td width=\"105\">Non-Approved<\/td>\n<td width=\"105\">C3*<\/td>\n<td width=\"143\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Maximum no. of intervals (n)<\/td>\n<td width=\"105\">5000 single<\/td>\n<td width=\"105\">1000<\/td>\n<td width=\"105\">3000<\/td>\n<td width=\"143\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Y = Emax\/Vmin<\/td>\n<td width=\"105\">10000<\/td>\n<td width=\"105\">1400<\/td>\n<td width=\"105\">10000<\/td>\n<td width=\"143\">Max. available<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Rated output\u2014R.O.<\/td>\n<td colspan=\"3\" width=\"316\">2.0<\/td>\n<td width=\"143\">mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Rated output tolerance<\/td>\n<td colspan=\"3\" width=\"316\">0.2<\/td>\n<td width=\"143\">\u00b1 mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Zero balance<\/td>\n<td colspan=\"3\" width=\"316\">0.2<\/td>\n<td width=\"143\">\u00b1 mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Zero return, 30 min.<\/td>\n<td width=\"105\">0.0250<\/td>\n<td width=\"105\">0.0300<\/td>\n<td width=\"105\">0.0170<\/td>\n<td width=\"143\">\u00b1% of applied load<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Total error (per OIML R60)<\/td>\n<td width=\"105\">0.0200<\/td>\n<td width=\"105\">0.0500<\/td>\n<td width=\"105\">0.0200<\/td>\n<td width=\"143\">\u00b1% of rated output<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Temperature effect on zero<\/td>\n<td width=\"105\">0.0023<\/td>\n<td width=\"105\">0.0100<\/td>\n<td width=\"105\">0.0023<\/td>\n<td width=\"143\">\u00b1% of rated output\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Temperature effect on output<\/td>\n<td width=\"105\">0.0010<\/td>\n<td width=\"105\">0.0030<\/td>\n<td width=\"105\">0.0010<\/td>\n<td width=\"143\">\u00b1% of applied load\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Eccentric loading error<\/td>\n<td width=\"105\">0.0033<\/td>\n<td width=\"105\">0.0050<\/td>\n<td width=\"105\">0.0033<\/td>\n<td width=\"143\">\u00b1% of rated load\/cm<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Temperature range, compensated<\/td>\n<td colspan=\"3\" width=\"316\">\u201310 to +40<\/td>\n<td width=\"143\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Temperature range, safe<\/td>\n<td colspan=\"3\" width=\"316\">\u201320 to +70<\/td>\n<td width=\"143\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Maximum safe central overload<\/td>\n<td colspan=\"3\" width=\"316\">150<\/td>\n<td width=\"143\">% of R.C.<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Ultimate central overload<\/td>\n<td colspan=\"3\" width=\"316\">300<\/td>\n<td width=\"143\">% of R.C.<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Excitation, recommended<\/td>\n<td colspan=\"3\" width=\"316\">10<\/td>\n<td width=\"143\">VDC or VAC RMS<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Excitation, maximum<\/td>\n<td colspan=\"3\" width=\"316\">15<\/td>\n<td width=\"143\">VDC or VAC RMS<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Input impedance<\/td>\n<td colspan=\"3\" width=\"316\">415\u00b115<\/td>\n<td width=\"143\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Output impedance<\/td>\n<td colspan=\"3\" width=\"316\">350\u00b13<\/td>\n<td width=\"143\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Insulation resistance<\/td>\n<td colspan=\"3\" width=\"316\">&gt;5000<\/td>\n<td width=\"143\">M\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Cable length<\/td>\n<td colspan=\"3\" width=\"316\">3.0<\/td>\n<td width=\"143\">m<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Cable type<\/td>\n<td colspan=\"3\" width=\"316\">6-wire, braided, Polyurethane, loating screen<\/td>\n<td width=\"143\">Standard<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Construction<\/td>\n<td colspan=\"3\" width=\"316\">Plated (anodized) aluminum<\/td>\n<td width=\"143\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Environmental protection<\/td>\n<td colspan=\"3\" width=\"316\">IP65**<\/td>\n<td width=\"143\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Platform size (max)<\/td>\n<td colspan=\"3\" width=\"316\">800 x 800***<\/td>\n<td width=\"143\">mm<\/td>\n<\/tr>\n<tr>\n<td width=\"190\">Recommended torque<\/td>\n<td colspan=\"3\" width=\"316\">Up to 1000 kg: 16.0 1500 kg: 32.0<\/td>\n<td width=\"143\">N*m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* 50% utilization<br \/>\n3500 divisions also available<br \/>\n** Available also in IP67<br \/>\n*** 635\u20131500 kg capacities: platform size 600 x 600 mm<br \/>\nAll speciications subject to change without notice.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-293971\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/616-1.png\" alt=\"\" width=\"472\" height=\"360\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/616-1.png 472w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/616-1-64x49.png 64w\" sizes=\"(max-width: 472px) 100vw, 472px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The load cell model 1250 is an aluminum single-point load cell designed for direct mounting of large platform scales. The 1250 is a cost-effective load cell for use on counting, weighing, bench or floor scale products as well as in hanging scales and check weighing. These high accuracy load cells are OIML R60 and NTEP approved. The load cell has IP65 protection as standard but for wash-down protection an optional IP67 encapsulation protection is available. For use in hazardous environments the 1250 is available in an EEx ia IIC T4 approved version. FM approved to class I, II, III, Division I.<\/p>\n","protected":false},"featured_media":294036,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5571,5572],"product_cat":[3385],"product_tag":[5070],"class_list":{"0":"post-294039","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-tedea-huntleigh","7":"product_brand-vpgforcesensors","8":"product_cat-single-point-en","9":"product_tag---en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/294039","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=294039"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/294036"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=294039"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=294039"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=294039"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=294039"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}