{"id":294073,"date":"2026-03-05T14:14:19","date_gmt":"2026-03-05T05:14:19","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/vpg-model-1510-hermetically-sealed-single-point-load-cell\/"},"modified":"2026-03-05T16:10:30","modified_gmt":"2026-03-05T07:10:30","slug":"vpg-model-1510-hermetically-sealed-single-point-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/vpg-model-1510-hermetically-sealed-single-point-load-cell\/","title":{"rendered":"Tedea Huntleigh \/ Model 1510 Hermetically Sealed Single-Point Load Cell"},"content":{"rendered":"<h2>Model 1510 Hermetically Sealed Single-Point Load Cell<\/h2>\n<p><strong>FEATURES<\/strong><br \/>\n\u2022 Capacity range: 100\u2013500 kg<br \/>\n\u2022 Stainless steel construction<br \/>\n\u2022 Single-point 600 x 600 mm platform<br \/>\n\u2022 OIML R60 and NTEP approved<br \/>\n\u2022 IP68 protection<br \/>\n\u2022 Optional<br \/>\n\u274d EEx ia IIC T6 hazardous area approval<br \/>\n\u274d FM approval available<br \/>\n\u274d Platform size 600 x 800 mm available<\/p>\n<p><strong>APPLICATIONS<\/strong><br \/>\n\u2022 Food industry platforms<br \/>\n\u2022 Marine and hybrid scales<br \/>\n\u2022 Process weighing hoppers<br \/>\n\u2022 Harsh environment<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-294071\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1510.png\" alt=\"\" width=\"1542\" height=\"872\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1510.png 1542w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1510-707x400.png 707w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1510-1400x792.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1510-768x434.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1510-1536x869.png 1536w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1510-600x339.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/1510-64x36.png 64w\" sizes=\"(max-width: 1542px) 100vw, 1542px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"6\" width=\"648\">SPECIFICATIONS<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">PARAMETER<\/td>\n<td colspan=\"4\" width=\"303\">VALUE<\/td>\n<td width=\"141\">UNIT<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Rated capacity\u2014R.C. (Emax)<\/td>\n<td colspan=\"4\" width=\"303\">100, 250, 500<\/td>\n<td width=\"141\">kg<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">NTEP\/OIML accuracy class<\/td>\n<td width=\"74\">NTEP<\/td>\n<td width=\"86\">Non-approved<\/td>\n<td width=\"72\">C3*<\/td>\n<td width=\"72\">C4*<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Maximum no. of intervals (n)<\/td>\n<td width=\"74\">5000 single<\/td>\n<td width=\"86\">1000<\/td>\n<td width=\"72\">3000<\/td>\n<td width=\"72\">4000<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Y = Emax\/Vmin<\/td>\n<td width=\"74\">11425<\/td>\n<td width=\"86\">1400<\/td>\n<td width=\"72\">10000<\/td>\n<td width=\"72\">12000<\/td>\n<td width=\"141\">Maximum available 12500<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Rated output\u2014R.O.<\/td>\n<td colspan=\"4\" width=\"303\">2.0<\/td>\n<td width=\"141\">mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Rated output tolerance<\/td>\n<td colspan=\"4\" width=\"303\">0.2<\/td>\n<td width=\"141\">\u00b1mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Zero balance<\/td>\n<td colspan=\"4\" width=\"303\">0.2<\/td>\n<td width=\"141\">\u00b1mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Zero return, 30 min.<\/td>\n<td width=\"74\">0.0170<\/td>\n<td width=\"86\">0.0060<\/td>\n<td width=\"72\">0.0170<\/td>\n<td width=\"72\">0.0130<\/td>\n<td width=\"141\">\u00b1% of applied load<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Total Error<\/td>\n<td width=\"74\">0.0200<\/td>\n<td width=\"86\">0.0300<\/td>\n<td width=\"72\">0.0200<\/td>\n<td width=\"72\">0.0150<\/td>\n<td width=\"141\">\u00b1% of rated output<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Temperature effect on zero<\/td>\n<td width=\"74\">0.0023<\/td>\n<td width=\"86\">0.010<\/td>\n<td width=\"72\">0.0014<\/td>\n<td width=\"72\">0.0011<\/td>\n<td width=\"141\">\u00b1% of rated output\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Temperature effect on output<\/td>\n<td width=\"74\">0.001<\/td>\n<td width=\"86\">0.0040<\/td>\n<td width=\"72\">0.0010<\/td>\n<td width=\"72\">0.0008<\/td>\n<td width=\"141\">\u00b1% of applied load\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Eccentric loading error<\/td>\n<td width=\"74\">0.0016<\/td>\n<td width=\"86\">0.0035<\/td>\n<td width=\"72\">0.0011<\/td>\n<td width=\"72\">0.0008<\/td>\n<td width=\"141\">\u00b1% of rated load\/cm<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Temperature range, compensated<\/td>\n<td colspan=\"4\" width=\"303\">\u201310 to +40<\/td>\n<td width=\"141\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Temperature range, safe<\/td>\n<td colspan=\"4\" width=\"303\">\u201320 to +70<\/td>\n<td width=\"141\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Maximum safe central overload<\/td>\n<td colspan=\"4\" width=\"303\">150<\/td>\n<td width=\"141\">% of R.C.<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Ultimate central overload<\/td>\n<td colspan=\"4\" width=\"303\">300<\/td>\n<td width=\"141\">% of R.C.<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Excitation, recommended<\/td>\n<td colspan=\"4\" width=\"303\">10<\/td>\n<td width=\"141\">VDC or VAC RMS<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Excitation, maximum<\/td>\n<td colspan=\"4\" width=\"303\">15<\/td>\n<td width=\"141\">VDC or VAC RMS<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Input impedance<\/td>\n<td colspan=\"4\" width=\"303\">380\u00b110<\/td>\n<td width=\"141\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Output impedance<\/td>\n<td colspan=\"4\" width=\"303\">350\u00b12<\/td>\n<td width=\"141\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Insulation resistance<\/td>\n<td colspan=\"4\" width=\"303\">&gt;1000<\/td>\n<td width=\"141\">M\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Cable length<\/td>\n<td colspan=\"4\" width=\"303\">3<\/td>\n<td width=\"141\">m<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Cable type<\/td>\n<td colspan=\"4\" width=\"303\">6-wire, braided, polyurethane, dual loating screen<\/td>\n<td width=\"141\">Standard<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Construction<\/td>\n<td colspan=\"4\" width=\"303\">Stainless steel<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Environmental protection<\/td>\n<td colspan=\"4\" width=\"303\">IP68<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Recommended torque<\/td>\n<td colspan=\"4\" width=\"303\">22.0<\/td>\n<td width=\"141\">N*m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>All speciications subject to change without notice.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-293971\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/616-1.png\" alt=\"\" width=\"472\" height=\"360\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/616-1.png 472w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/616-1-64x49.png 64w\" sizes=\"(max-width: 472px) 100vw, 472px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The load cell model 1510 is a high accuracy stainless steel single-point load cell suitable to industrial application which undergo regular washdown, typically platforms, wall scales and other process weighing applications in the food industry. Hermetically sealed to IP68 against moisture, the all welded construction of the 1510 enables continuous operation in harsh environments while maintaining a high operating specification. The load cell is OIML R60 and NTEP approved. For hazardous environments this load cell has EEx ia IIC T6 level approved version available.<\/p>\n","protected":false},"featured_media":294070,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5571,5572],"product_cat":[3385],"product_tag":[5070],"class_list":{"0":"post-294073","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-tedea-huntleigh","7":"product_brand-vpgforcesensors","8":"product_cat-single-point-en","9":"product_tag---en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/294073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=294073"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/294070"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=294073"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=294073"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=294073"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=294073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}