{"id":294114,"date":"2026-03-05T15:06:46","date_gmt":"2026-03-05T06:06:46","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/vpg-model-bsp-universal-load-cell\/"},"modified":"2026-03-05T16:05:21","modified_gmt":"2026-03-05T07:05:21","slug":"vpg-model-bsp-universal-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/vpg-model-bsp-universal-load-cell\/","title":{"rendered":"Revere Transducers \/ Model BSP Universal Load Cell"},"content":{"rendered":"<h2>Model BSP Universal Load Cell<\/h2>\n<p><strong>FEATURES<\/strong><br \/>\n\u2022 Capacities: 50\u20135000 kg, 100\u201310k lbs<br \/>\n\u2022 Fully welded, stainless steel construction<br \/>\n\u2022 Hermetically sealed, IP66 and IP68<br \/>\n\u2022 Certiied to OIML R-60, 3000d<br \/>\n\u2022 Integrated overload stop (50\u2013500 kg)<br \/>\n\u2022 Current calibration output (SC version) ensures easy<br \/>\nand accurate parallel connection of multiple load cells<br \/>\n\u2022 Optional<br \/>\n\u274d ATEX and FM certiied versions are available<\/p>\n<p><strong>APPLICATIONS<\/strong><br \/>\n\u2022 Hybrid scales<br \/>\n\u2022 Process weighing<br \/>\n\u2022 Belt checkweighers<br \/>\n\u2022 Dynamometers<br \/>\n\u2022 Material testing machines<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-294112\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/ACB-2.png\" alt=\"\" width=\"1417\" height=\"886\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/ACB-2.png 1417w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/ACB-2-640x400.png 640w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/ACB-2-1279x800.png 1279w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/ACB-2-768x480.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/ACB-2-600x375.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/ACB-2-64x40.png 64w\" sizes=\"(max-width: 1417px) 100vw, 1417px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"5\" width=\"648\"><strong>SPECIFICATIONS<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"252\">PARAMETER<\/td>\n<td colspan=\"3\" width=\"255\">VALUE<\/td>\n<td width=\"141\">UNIT<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Standard capacities (Emax)<\/td>\n<td colspan=\"3\" width=\"255\">50, 125, 250, 500, 1250, 2500, 5000<\/td>\n<td width=\"141\">kg<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Standard capacities (Emax)<\/td>\n<td colspan=\"3\" width=\"255\">100, 250, 500, 1000, 2500, 5000, 10000<\/td>\n<td width=\"141\">lbs<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Accuracy class according to OIML R-60 \/NTEP<\/td>\n<td width=\"85\">NTEP IIIL<\/td>\n<td width=\"85\">Non-Approved<\/td>\n<td width=\"85\">C3<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Maximum number of verfication intervals<\/td>\n<td width=\"85\">10000<\/td>\n<td width=\"85\">\u00a0<\/td>\n<td width=\"85\">3000<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Minimum verification interval = Vmin\/Emax\/Y)<\/td>\n<td colspan=\"2\" width=\"170\">\u00a0<\/td>\n<td width=\"85\">Emax\/10000<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Rated output (=S)<\/td>\n<td colspan=\"3\" width=\"255\">3 (2 for 2500 and 5000 kg)<\/td>\n<td width=\"141\">mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Rated output tolerance<\/td>\n<td colspan=\"3\" width=\"255\">0.03 (0.02 for 2500 and 5000 kg)<\/td>\n<td width=\"141\">\u00b1 mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Zero balance<\/td>\n<td colspan=\"3\" width=\"255\">1.0<\/td>\n<td width=\"141\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Combined error<\/td>\n<td width=\"85\">0.0200<\/td>\n<td width=\"85\">0.0500<\/td>\n<td width=\"85\">0.0200<\/td>\n<td width=\"141\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Non-repeatability<\/td>\n<td width=\"85\">0.0100<\/td>\n<td width=\"85\">0.0200<\/td>\n<td width=\"85\">0.0100<\/td>\n<td width=\"141\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Minimum dead load output return<\/td>\n<td width=\"85\">\u00a0<\/td>\n<td width=\"85\">0.0500<\/td>\n<td width=\"85\">0.0167<\/td>\n<td width=\"141\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Creep error (30 minutes)<\/td>\n<td width=\"85\">\u00a0<\/td>\n<td width=\"85\">0.0600<\/td>\n<td width=\"85\">0.0245<\/td>\n<td width=\"141\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Creep error (20\u201330 minutes)<\/td>\n<td width=\"85\">0.0300<\/td>\n<td width=\"85\">0.0200<\/td>\n<td width=\"85\">\u00a0<\/td>\n<td width=\"141\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Temp. effect on minimum dead load output<\/td>\n<td width=\"85\">(0.0008)<\/td>\n<td width=\"85\">0.0250<\/td>\n<td width=\"85\">0.0070<\/td>\n<td width=\"141\">\u00b1% FSO\/5\u00b0C (\/\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Temperature effect on sensitivity<\/td>\n<td width=\"85\">(0.0010)<\/td>\n<td width=\"85\">0.0250<\/td>\n<td width=\"85\">0.0050<\/td>\n<td width=\"141\">\u00b1% FSO\/5\u00b0C (\/\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Minimum dead load<\/td>\n<td colspan=\"3\" width=\"255\">0<\/td>\n<td width=\"141\">% Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Maximum safe overload<\/td>\n<td colspan=\"3\" width=\"255\">150<\/td>\n<td width=\"141\">% Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Ultimate overload<\/td>\n<td colspan=\"3\" width=\"255\">300<\/td>\n<td width=\"141\">% Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Maximum safe side load<\/td>\n<td colspan=\"3\" width=\"255\">100<\/td>\n<td width=\"141\">% Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Deflection at Emax<\/td>\n<td colspan=\"3\" width=\"255\">0.28 max.<\/td>\n<td width=\"141\">mm<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Excitation voltage<\/td>\n<td colspan=\"3\" width=\"255\">5 to 15<\/td>\n<td width=\"141\">V<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Maximum excitation voltage<\/td>\n<td colspan=\"3\" width=\"255\">18<\/td>\n<td width=\"141\">V<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Input resistance<\/td>\n<td colspan=\"3\" width=\"255\">350\u00b13.5<\/td>\n<td width=\"141\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Output resistance<\/td>\n<td colspan=\"3\" width=\"255\">350\u00b13.5<\/td>\n<td width=\"141\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Insulation resistance<\/td>\n<td colspan=\"3\" width=\"255\">\u22655000<\/td>\n<td width=\"141\">M\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Compensated temperature range<\/td>\n<td colspan=\"3\" width=\"255\">\u201310 to +40<\/td>\n<td width=\"141\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Operating temperature range<\/td>\n<td colspan=\"3\" width=\"255\">\u201340 to +80<\/td>\n<td width=\"141\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Storage temperature range<\/td>\n<td colspan=\"3\" width=\"255\">\u201340 to +90<\/td>\n<td width=\"141\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Element material (DIN)<\/td>\n<td colspan=\"3\" width=\"255\">Stainless steel 1.4542<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">Sealing (DIN 40.050 \/ EN60.529)<\/td>\n<td colspan=\"3\" width=\"255\">IP66 and IP68<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"252\">SC-Version (current calibration)<\/td>\n<td colspan=\"3\" width=\"255\">Standard<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>FSO\u2014Full Scale Output<br \/>\nSC-version: The rated output and the output resistance are balanced in such a way that the output current is calibrated to within 0.05%<br \/>\nof a reference value. This allows easy parallel connection of the load cells.<br \/>\nAll speciications subject to change without notice.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The load cell model BSP is a stainless steel S \u2013 type load cell designed for tension and compression. The load cell is well suited for hybrid scales, overhead track scales, belt scales and process weighing applications. The fully welded constructions and water block cable entry ensure that the BSP is suitable in a harsh environment found in the food, chemical and allied process industries. For hazardous environments it is available in an ATEX or FM approved version. Certified to OIML R-60, 3000d. Hermetically sealed, IP66 and IP68. The load cell is available in the capacities 50 -5000 kg and 100 -10 k lbs.<\/p>\n","protected":false},"featured_media":294111,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5584,5571,5572],"product_cat":[3368],"product_tag":[5580],"class_list":{"0":"post-294114","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-revere-transducers","7":"product_brand-tedea-huntleigh","8":"product_brand-vpgforcesensors","9":"product_cat-s-type-load-cell","10":"product_tag--en","12":"first","13":"instock","14":"taxable","15":"shipping-taxable","16":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/294114","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=294114"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/294111"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=294114"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=294114"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=294114"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=294114"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}