{"id":294120,"date":"2026-03-05T15:12:25","date_gmt":"2026-03-05T06:12:25","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/vpg-model-csp-compression-load-cell\/"},"modified":"2026-03-05T16:05:21","modified_gmt":"2026-03-05T07:05:21","slug":"vpg-model-csp-compression-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/vpg-model-csp-compression-load-cell\/","title":{"rendered":"Revere Transducers \/ Model CSP Compression Load Cell"},"content":{"rendered":"<h2>Model CSP Compression Load Cell<\/h2>\n<p><strong>FEATURES<\/strong><br \/>\n\u2022 Capacities: 10\u2013100 t<br \/>\n\u2022 Low proile, multi-column stainless steel construction<br \/>\n\u2022 Hermetically sealed, IP66, IP68, and IP69K<br \/>\n\u2022 Certiied to OIML R-60, 4000d and NTEP class IIIL 10000 divisions<br \/>\n\u274d Model CSP offers klb capacity, imperial thread and NTEP approval<br \/>\n\u274d Model CSP-M offers metric capacity, thread and OIML<br \/>\napproval<br \/>\n\u2022 Built-in surge protection tubes (GDTs)<br \/>\n\u2022 Current calibration output (SC version) ensures easy and accurate parallel connection of multiple load cells<br \/>\n\u2022 Optional<br \/>\n\u274d ATEX and FM certiied versions are available for use in potentially explosive atmospheres<br \/>\n\u274d Multi-interval and multiple range versions available<br \/>\n\u274d Imperial capacities (25k, 50k, 100k, 200k lbs) not OIML approved<\/p>\n<p><strong>APPLICATIONS<\/strong><br \/>\n\u2022 Truck and rail weighbridges<br \/>\n\u2022 Silo and hopper weighing<br \/>\n\u2022 Process weighing<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-294118\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/CSP.png\" alt=\"\" width=\"1537\" height=\"970\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/CSP.png 1537w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/CSP-634x400.png 634w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/CSP-1268x800.png 1268w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/CSP-768x485.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/CSP-600x379.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/CSP-64x40.png 64w\" sizes=\"(max-width: 1537px) 100vw, 1537px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"6\" width=\"648\"><strong>SPECIFICATIONS<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"256\">PARAMETER<\/td>\n<td colspan=\"4\" width=\"291\">VALUE<\/td>\n<td width=\"100\">UNIT<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Standard capacities (Emax)<\/td>\n<td colspan=\"4\" width=\"291\">10, 25, 40, 60, 100<sup>(1)<\/sup>\u00a010<sup>(2)<\/sup>, 25, 40, 50, 60, 75, 100, 150, 200, 300<sup>(2)<\/sup>, 500<sup>(2)<\/sup><\/td>\n<td width=\"100\">t klb<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Accuracy class according to OIML R-60\/NTEP<\/td>\n<td width=\"69\">NTEP IIIL<\/td>\n<td width=\"79\">NTEP IIIL<\/td>\n<td width=\"72\">C3<\/td>\n<td width=\"72\">C4<\/td>\n<td width=\"100\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Maximum no. of verification intervals<\/td>\n<td width=\"69\">10000<\/td>\n<td width=\"79\">3000<\/td>\n<td width=\"72\">3000<\/td>\n<td width=\"72\">4000<\/td>\n<td width=\"100\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Minimum verification interval (Vmin=Emax\/Y)<sup>(3)<\/sup><\/td>\n<td width=\"69\">Emax\/5200<\/td>\n<td width=\"79\">Emax\/29000<\/td>\n<td width=\"72\">Emax\/12,500<\/td>\n<td width=\"72\">Emax\/12,500<\/td>\n<td width=\"100\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Minimum verification interval, type MR<\/td>\n<td width=\"69\">\u00a0<\/td>\n<td width=\"79\">\u00a0<\/td>\n<td width=\"72\">Emax\/17,500<\/td>\n<td width=\"72\">Emax\/17,500<\/td>\n<td width=\"100\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Rated output (=S)<\/td>\n<td colspan=\"4\" width=\"291\">2<\/td>\n<td width=\"100\">\u00b1mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Rated output tolerance<\/td>\n<td colspan=\"4\" width=\"291\">0.02<\/td>\n<td width=\"100\">\u00b1mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Zero balance<\/td>\n<td colspan=\"4\" width=\"291\">1.0<\/td>\n<td width=\"100\">mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Total error<\/td>\n<td width=\"69\">0.02<\/td>\n<td width=\"79\">0.05<\/td>\n<td width=\"72\">0.023<\/td>\n<td width=\"72\">0.017<\/td>\n<td width=\"100\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Nonrepeatability<\/td>\n<td width=\"69\">0.01<\/td>\n<td width=\"79\">0.01<\/td>\n<td width=\"72\">0.01<\/td>\n<td width=\"72\">0.009<\/td>\n<td width=\"100\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Zero return<\/td>\n<td width=\"69\">0.015<\/td>\n<td width=\"79\">0.0167<\/td>\n<td width=\"72\">0.0167<\/td>\n<td width=\"72\">0.0125<\/td>\n<td width=\"100\">\u00b1% applied load<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Creep error (30 minutes)<\/td>\n<td width=\"69\">0.05<\/td>\n<td width=\"79\">0.035<\/td>\n<td width=\"72\">0.0245<\/td>\n<td width=\"72\">0.0184<\/td>\n<td width=\"100\">\u00b1% applied load<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Temp. effect on min. dead load output<\/td>\n<td width=\"69\">0.00144<\/td>\n<td width=\"79\">0.0027<\/td>\n<td width=\"72\">0.0011<\/td>\n<td width=\"72\">0.0011<\/td>\n<td width=\"100\">\u00b1% FSO\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Temp. effect on min. dead load output, type MR<\/td>\n<td width=\"69\">\u00a0<\/td>\n<td width=\"79\">\u00a0<\/td>\n<td width=\"72\">0.0008<\/td>\n<td width=\"72\">0.008<\/td>\n<td width=\"100\">\u00b1% FSO\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Temperature effect on sensitivity<\/td>\n<td width=\"69\">0.00144<\/td>\n<td width=\"79\">0.00144<\/td>\n<td width=\"72\">0.001<\/td>\n<td width=\"72\">0.0007<\/td>\n<td width=\"100\">\u00b1% applied load\/5<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Maximum safe static overload<\/td>\n<td colspan=\"4\" width=\"291\">150<\/td>\n<td width=\"100\">% Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Ultimate static overload<\/td>\n<td colspan=\"4\" width=\"291\">400<\/td>\n<td width=\"100\">% Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Maximum safe side load<\/td>\n<td colspan=\"4\" width=\"291\">10<\/td>\n<td width=\"100\">% Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Excitation voltage<\/td>\n<td colspan=\"4\" width=\"291\">5 to 20<\/td>\n<td width=\"100\">V<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Excitation recommended<\/td>\n<td colspan=\"4\" width=\"291\">10<\/td>\n<td width=\"100\">V<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Input resistance<\/td>\n<td colspan=\"4\" width=\"291\">450 \u00b14.5<\/td>\n<td width=\"100\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Output resistance<\/td>\n<td colspan=\"4\" width=\"291\">480 \u00b14.8<\/td>\n<td width=\"100\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Insulation resistance<\/td>\n<td colspan=\"4\" width=\"291\">&gt;5000<\/td>\n<td width=\"100\">M\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Compensated temperature range<\/td>\n<td colspan=\"4\" width=\"291\">\u201310 to +40<\/td>\n<td width=\"100\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Operating temperature range<\/td>\n<td colspan=\"4\" width=\"291\">\u201340 to +80<\/td>\n<td width=\"100\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Storage temperature range<\/td>\n<td colspan=\"4\" width=\"291\">\u201350 to +90<\/td>\n<td width=\"100\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Element material<\/td>\n<td colspan=\"4\" width=\"291\">Stainless steel 1.4542<\/td>\n<td width=\"100\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Sealing (DIN 40.050 \/ EN60.529)<\/td>\n<td colspan=\"4\" width=\"291\">IP66 and IP68<\/td>\n<td width=\"100\">\u00a0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><sup>(1)<\/sup> 100 t only has C1 grade of OIML<\/p>\n<p><sup>(2)<\/sup> 10, 300, 500 klb are not NTEP approved<\/p>\n<p><sup>(3)<\/sup> Approval limit: Class III Vmin=Emax\/10000 (0.0014%Of FSO\/\u00b0C); Class IIIL Vmin=E<sup>max<\/sup>\/30000 (0.0014%Of FSO\/\u00b0C)<\/p>\n<p>FSO\u2014Full Scale Output<\/p>\n<p>SC-version: The rated output and the output resistance are balanced in such a way, that the output current is calibrated to within 0.05% of a reference value. This allows easy parallel connection of the load cells.<\/p>\n<p>All speciications subject to change without notice.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The load cell model CSP is a stainless steel, low profile multi-column, compression load cell. The fully welded construction, advanced cable entry and built-in surge protection tubes ensure that this product can be used successfully in harsh environments. This heavy-duty load cell is suited for hopper, tank, silo weighing and many other large-scale industrial applications, including weighbridges for truck weighing, it is available in the capacities 10 \u2013 100 tons. It is sealed to IP68. Certified to OIML R-60, 4000d and NTEP class IIIL 10000 divisions. ATEX and FM certified versions are available for use in explosive atmospheres.<\/p>\n","protected":false},"featured_media":294117,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5584,5572],"product_cat":[3387],"product_tag":[4646],"class_list":{"0":"post-294120","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-revere-transducers","7":"product_brand-vpgforcesensors","8":"product_cat-tension-compression-load-cell","9":"product_tag-compression-load-cell-en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/294120","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=294120"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/294117"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=294120"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=294120"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=294120"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=294120"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}