{"id":294126,"date":"2026-03-05T15:15:46","date_gmt":"2026-03-05T06:15:46","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/vpg-model-hps-single-point-load-cell\/"},"modified":"2026-03-05T16:05:21","modified_gmt":"2026-03-05T07:05:21","slug":"vpg-model-hps-single-point-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/vpg-model-hps-single-point-load-cell\/","title":{"rendered":"Revere Transducers \/ Model HPS Single-Point Load Cell"},"content":{"rendered":"<h2>Model HPS Single-Point Load Cell<\/h2>\n<p><strong>FEATURES<\/strong><br \/>\n\u2022 Capacities: 10\u2013100 t<br \/>\n\u2022 Low proile, multi-column stainless steel construction<br \/>\n\u2022 Hermetically sealed, IP66, IP68, and IP69K<br \/>\n\u2022 Certiied to OIML R-60, 4000d and NTEP class IIIL 10000 divisions<br \/>\n\u274d Model CSP offers klb capacity, imperial thread and NTEP approval<br \/>\n\u274d Model CSP-M offers metric capacity, thread and OIML<br \/>\napproval<br \/>\n\u2022 Built-in surge protection tubes (GDTs)<br \/>\n\u2022 Current calibration output (SC version) ensures easy and accurate parallel connection of multiple load cells<br \/>\n\u2022 Optional<br \/>\n\u274d ATEX and FM certiied versions are available for use in potentially explosive atmospheres<br \/>\n\u274d Multi-interval and multiple range versions available<br \/>\n\u274d Imperial capacities (25k, 50k, 100k, 200k lbs) not OIML approved<\/p>\n<p><strong>APPLICATIONS<\/strong><br \/>\n\u2022 Truck and rail weighbridges<br \/>\n\u2022 Silo and hopper weighing<br \/>\n\u2022 Process weighing<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-294124\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/CSP2.png\" alt=\"\" width=\"1535\" height=\"830\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/CSP2.png 1535w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/CSP2-740x400.png 740w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/CSP2-1400x757.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/CSP2-768x415.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/CSP2-600x324.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/CSP2-64x35.png 64w\" sizes=\"(max-width: 1535px) 100vw, 1535px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"4\" width=\"648\"><strong>SPECIFICATIONS<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"243\">PARAMETER<\/td>\n<td colspan=\"2\" width=\"265\">VALUE<\/td>\n<td width=\"141\">UNIT<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Standard capacities (Emax)<\/td>\n<td colspan=\"2\" width=\"265\">6, 12, 30, 60<\/td>\n<td width=\"141\">kg<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Accuracy class according to OIML R-60<\/td>\n<td width=\"132\">Non-Approved<\/td>\n<td width=\"132\">C3<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Max. no. of verfication intervals<\/td>\n<td width=\"132\">\u00a0<\/td>\n<td width=\"132\">3000<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Min. verification interval (Vmin)<\/td>\n<td width=\"132\">\u00a0<\/td>\n<td width=\"132\">Emax\/12000<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Rated output (=S)<\/td>\n<td colspan=\"2\" width=\"265\">2<\/td>\n<td width=\"141\">mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Rated output tolerance<\/td>\n<td colspan=\"2\" width=\"265\">0.2<\/td>\n<td width=\"141\">\u00b1% mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Zero balance<\/td>\n<td colspan=\"2\" width=\"265\">1.0<\/td>\n<td width=\"141\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Combined error<\/td>\n<td width=\"132\">0.0500<\/td>\n<td width=\"132\">0.0200<\/td>\n<td width=\"141\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Non-repeatability<\/td>\n<td width=\"132\">0.0200<\/td>\n<td width=\"132\">0.0100<\/td>\n<td width=\"141\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Minimum dead load output return<\/td>\n<td width=\"132\">0.0500<\/td>\n<td width=\"132\">0.0167<\/td>\n<td width=\"141\">\u00b1% applied load<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Creep error (30 minutes)<\/td>\n<td width=\"132\">0.0600<\/td>\n<td width=\"132\">0.0245<\/td>\n<td width=\"141\">\u00b1% applied load<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Temperature effect on min. dead load output<\/td>\n<td width=\"132\">0.0250<\/td>\n<td width=\"132\">0.0058<\/td>\n<td width=\"141\">\u00b1% FSO\/5\u00b0C (\/\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Temperature effect on sensitivity<\/td>\n<td width=\"132\">0.0250<\/td>\n<td width=\"132\">0.0045<\/td>\n<td width=\"141\">\u00b1% applied load\/5\u00b0C (\/\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Eccentric load effect*<\/td>\n<td colspan=\"2\" width=\"265\">0.03<\/td>\n<td width=\"141\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Minimum dead load<\/td>\n<td colspan=\"2\" width=\"265\">0<\/td>\n<td width=\"141\">% Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Maximum safe overload<\/td>\n<td colspan=\"2\" width=\"265\">150<\/td>\n<td width=\"141\">% Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Ultimate overload<\/td>\n<td colspan=\"2\" width=\"265\">300<\/td>\n<td width=\"141\">% Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Maximum safe side load<\/td>\n<td colspan=\"2\" width=\"265\">100<\/td>\n<td width=\"141\">% Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Deflection at Emax<\/td>\n<td colspan=\"2\" width=\"265\">0.24\u00b10.02 \/ 0.19\u00b10.01 \/ 0.15\u00b10.01 \/ 0.22\u00b10.03<\/td>\n<td width=\"141\">mm<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Excitation voltage<\/td>\n<td colspan=\"2\" width=\"265\">5 to 12<\/td>\n<td width=\"141\">V<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Maximum excitation voltage<\/td>\n<td colspan=\"2\" width=\"265\">15<\/td>\n<td width=\"141\">V<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Input resistance<\/td>\n<td width=\"132\">400\u00b16<\/td>\n<td width=\"132\">400\u00b16<\/td>\n<td width=\"141\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Output resistance<\/td>\n<td colspan=\"2\" width=\"265\">350\u00b17<\/td>\n<td width=\"141\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Insulation resistance<\/td>\n<td colspan=\"2\" width=\"265\">\u22655000<\/td>\n<td width=\"141\">M\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Compensated temperature range<\/td>\n<td colspan=\"2\" width=\"265\">\u201310 to +40<\/td>\n<td width=\"141\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Operating temperature range<\/td>\n<td colspan=\"2\" width=\"265\">\u201340 to +80<\/td>\n<td width=\"141\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Storage temperature range<\/td>\n<td colspan=\"2\" width=\"265\">\u201340 to +90<\/td>\n<td width=\"141\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Element material (DIN)<\/td>\n<td colspan=\"2\" width=\"265\">Stainless steel 1.4542<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Sealing (DIN 40.050 \/ EN60.529)<\/td>\n<td colspan=\"2\" width=\"265\">IP66 and IP68<\/td>\n<td width=\"141\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Recommended torque on fixation bolts<\/td>\n<td colspan=\"2\" width=\"265\">6<\/td>\n<td width=\"141\">N*m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* Applies at 50% x Rated Load at 150 mm radius<br \/>\nAll speciications subject to change without notice.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The HPS stainless steel single-point load cell is fully welded. The load cell is suitable for process weighing applications, low capacity platform scales, multi-head packaging machines, check weighers, loss-in-weight feeders belt scales and other applications. The unique construction ensures that the load cell is well suited for harsh environments found in the food, chemical and allied industries. It is available in an ATEX and FM approved version for use in hazardous areas. Certified to OIML R-60, 3000d. ATEX and FM certified versions are available for use in explosive atmospheres. Hermetically sealed, IP66 and IP68.<\/p>\n","protected":false},"featured_media":294123,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5584,5572],"product_cat":[3387],"product_tag":[4646],"class_list":{"0":"post-294126","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-revere-transducers","7":"product_brand-vpgforcesensors","8":"product_cat-tension-compression-load-cell","9":"product_tag-compression-load-cell-en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/294126","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=294126"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/294123"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=294126"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=294126"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=294126"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=294126"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}