{"id":294144,"date":"2026-03-05T15:38:29","date_gmt":"2026-03-05T06:38:29","guid":{"rendered":"https:\/\/casscale.net\/product\/sample-product\/vpg-5123-single-ended-beam-load-cell\/"},"modified":"2026-03-05T16:05:19","modified_gmt":"2026-03-05T07:05:19","slug":"vpg-5123-single-ended-beam-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/product\/sample-product\/vpg-5123-single-ended-beam-load-cell\/","title":{"rendered":"Revere Transducers \/ 5123 Single-Ended Beam Load Cell"},"content":{"rendered":"<h2>5123 Single-Ended Beam Load Cell<\/h2>\n<p><strong>FEATURES<\/strong><br \/>\n\u2022 Capacities: 500\u20135000 kg, 1k\u201310k lbs.<br \/>\n\u2022 Low proile construction<br \/>\n\u2022 Certiied to OIML R-60, 3000d and NTEP class III, 3000<br \/>\ndivisions<br \/>\n\u2022 Sealing: IP67 (DIN 40.050)<br \/>\n\u2022 Nickel-plated alloy steel construction<br \/>\n\u2022 Threaded load hole<br \/>\n\u2022 Optional<br \/>\n\u274d FM certiied for use in potentially explosive<br \/>\natmospheres<\/p>\n<p><strong>APPLICATIONS<\/strong><br \/>\n\u2022 Floor scales<br \/>\n\u2022 Tank weighing<br \/>\n\u2022 Bin and hopper weighing<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-294142\" src=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/5123-2.png\" alt=\"\" width=\"1540\" height=\"777\" srcset=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/5123-2.png 1540w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/5123-2-793x400.png 793w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/5123-2-1400x706.png 1400w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/5123-2-768x387.png 768w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/5123-2-1536x775.png 1536w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/5123-2-600x303.png 600w, https:\/\/casscale.net\/wp-content\/uploads\/2026\/03\/5123-2-64x32.png 64w\" sizes=\"(max-width: 1540px) 100vw, 1540px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"5\" width=\"648\"><strong>SPECIFICATIONS<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"221\">PARAMETER<\/td>\n<td colspan=\"3\" width=\"288\">VALUE<\/td>\n<td width=\"139\">UNIT<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Standard capacities (Emax)<\/td>\n<td colspan=\"3\" width=\"288\">500, 1000, 2000, 5000\u00a0<sup>(1)<\/sup><\/td>\n<td width=\"139\">kg<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Standard capacities (Emax)<\/td>\n<td colspan=\"3\" width=\"288\">1k, 2.5k, 4k, 5k, 10k\u00a0<sup>(1)<\/sup><\/td>\n<td width=\"139\">lbs.<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Accuracy class according to OIML R-60 \/NTEP<\/td>\n<td width=\"96\">NTEP III<\/td>\n<td width=\"96\">Non- Approved<\/td>\n<td width=\"96\">C3<\/td>\n<td width=\"139\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Max. no. of verfication intervals<\/td>\n<td width=\"96\">3000<\/td>\n<td width=\"96\">\u00a0<\/td>\n<td width=\"96\">3000<\/td>\n<td width=\"139\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Min. verification interval (Vmin=Emax\/Y)<\/td>\n<td width=\"96\">\u00a0<\/td>\n<td width=\"96\">\u00a0<\/td>\n<td width=\"96\">Emax\/6000<\/td>\n<td width=\"139\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Min. verification interval, type MR<\/td>\n<td width=\"96\">\u00a0<\/td>\n<td width=\"96\">\u00a0<\/td>\n<td width=\"96\">Emax\/10000<\/td>\n<td width=\"139\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Rated output (=S)<\/td>\n<td colspan=\"3\" width=\"288\">3<\/td>\n<td width=\"139\">mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Rated output tolerance<\/td>\n<td colspan=\"3\" width=\"288\">0.0075<\/td>\n<td width=\"139\">\u00b1mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Zero balance<\/td>\n<td colspan=\"3\" width=\"288\">1.0<\/td>\n<td width=\"139\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Combined error<\/td>\n<td width=\"96\">0.0200<\/td>\n<td width=\"96\">0.050<\/td>\n<td width=\"96\">0.023<\/td>\n<td width=\"139\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Minimum dead load output return<\/td>\n<td width=\"96\">0.0250<\/td>\n<td width=\"96\">0.050<\/td>\n<td width=\"96\">0.017<\/td>\n<td width=\"139\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Minimum dead load output return, type MI8<\/td>\n<td width=\"96\">\u00a0<\/td>\n<td width=\"96\">\u00a0<\/td>\n<td width=\"96\">0.0063<\/td>\n<td width=\"139\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Non-repeatability<\/td>\n<td width=\"96\">0.0100<\/td>\n<td width=\"96\">0.01<\/td>\n<td width=\"96\">0.01<\/td>\n<td width=\"139\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Creep error (30 minutes)<\/td>\n<td width=\"96\">\u00a0<\/td>\n<td width=\"96\">0.060<\/td>\n<td width=\"96\">0.025<\/td>\n<td width=\"139\">\u00b1% FSO<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Temp. effect on min. dead load output<\/td>\n<td width=\"96\">(0.0008)<\/td>\n<td width=\"96\">0.0250<\/td>\n<td width=\"96\">0.0120<\/td>\n<td width=\"139\">\u00b1% FSO\/5\u00b0C (\/\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Temp. effect on min. dead load output, type MR<\/td>\n<td width=\"96\">\u00a0<\/td>\n<td width=\"96\">\u00a0<\/td>\n<td width=\"96\">0.0070<\/td>\n<td width=\"139\">\u00b1% FSO\/5\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Temperature effect on sensitivity<\/td>\n<td width=\"96\">(0.0010)<\/td>\n<td width=\"96\">0.0250<\/td>\n<td width=\"96\">0.0088<\/td>\n<td width=\"139\">\u00b1% FSO\/5\u00b0C (\/\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Minimum dead load<\/td>\n<td colspan=\"3\" width=\"288\">0<\/td>\n<td width=\"139\">% Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Maximum safe overload<\/td>\n<td colspan=\"3\" width=\"288\">150<\/td>\n<td width=\"139\">% Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Ultimate overload<\/td>\n<td colspan=\"3\" width=\"288\">300<\/td>\n<td width=\"139\">% Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Maximum safe side load<\/td>\n<td colspan=\"3\" width=\"288\">100<\/td>\n<td width=\"139\">% Emax<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Deflection at Emax<\/td>\n<td colspan=\"3\" width=\"288\">0.4 \/ 0.8 \/ 1.0 \/ 1.1\u2014kg 0.4 \/ 0.8 \/ 1.0 \/ 0.9 \/ 1.1\u2014lbs.<\/td>\n<td width=\"139\">mm<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Excitation voltage<\/td>\n<td colspan=\"3\" width=\"288\">5 to 12<\/td>\n<td width=\"139\">V<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Maximum excitation voltage<\/td>\n<td colspan=\"3\" width=\"288\">15<\/td>\n<td width=\"139\">V<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Input resistance<\/td>\n<td colspan=\"3\" width=\"288\">350\u00b17<\/td>\n<td width=\"139\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Output resistance<\/td>\n<td colspan=\"3\" width=\"288\">352\u00b13<\/td>\n<td width=\"139\">\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Insulation resistance<\/td>\n<td colspan=\"3\" width=\"288\">&gt;1000<\/td>\n<td width=\"139\">M\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Compensated temperature range<\/td>\n<td colspan=\"3\" width=\"288\">\u201310 to +40<\/td>\n<td width=\"139\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Operating temperature range<\/td>\n<td colspan=\"3\" width=\"288\">\u201318 to +65<\/td>\n<td width=\"139\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Storage temperature range<\/td>\n<td colspan=\"3\" width=\"288\">\u201350 to +85<\/td>\n<td width=\"139\">\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Element material<\/td>\n<td colspan=\"3\" width=\"288\">Nickel-plated alloy steel<\/td>\n<td width=\"139\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Sealing (DIN 40.050 \/ EN 60.529)<\/td>\n<td colspan=\"3\" width=\"288\">IP67<\/td>\n<td width=\"139\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"221\">Recommended torque on fixation bolts<\/td>\n<td colspan=\"3\" width=\"288\">0.5\u20132T and 1k\u20134k lbs.: 136 5k lbs. and 5T and over: 205<\/td>\n<td width=\"139\">N*m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><sup>(1)<\/sup> 5T and 10k lbs. are not approved by OIML FSO\u2014Full Scale Output<\/p>\n<p>Correct mounting of the load cell is essential to ensure optimum performance. Further information is available on request. All speciications are subject to change without notice<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The load cell model 5123 is a low-profile single-ended shear beam load cell. The load cell is available in the capacities 5 &#8211; 5000kg and 1k &#8211; 10k lbs in nickel-plated ally steel. 5123 is well suited for process weighing applications, bin and hopper scales, platforms scales, overhead track scales and tank weighing. The load cell is approved to OIML R60, 3000 division and NTEP III 3000 division and hermetically sealed to IP67. Easy installation due to the use of a partially threaded hole to accept levelling feet or load buttons. The Revere 5123 load cell is available in a FM approved version for use in potentially hazardous areas.<\/p>\n","protected":false},"featured_media":294141,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[5584,5572],"product_cat":[3382],"product_tag":[5436],"class_list":{"0":"post-294144","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-revere-transducers","7":"product_brand-vpgforcesensors","8":"product_cat-bending-shear-beam-en","9":"product_tag-----en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/294144","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=294144"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/294141"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=294144"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=294144"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=294144"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=294144"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}