{"id":313083,"date":"2026-08-05T10:43:42","date_gmt":"2026-08-05T01:43:42","guid":{"rendered":"https:\/\/casscale.net\/?post_type=product&#038;p=313083"},"modified":"2026-08-05T10:46:11","modified_gmt":"2026-08-05T01:46:11","slug":"kistler-morse-load-disc-ii-load-cell","status":"publish","type":"product","link":"https:\/\/casscale.net\/en\/products\/kistler-morse-load-disc-ii-load-cell\/","title":{"rendered":"Kistler Morse LOAD DISC II LOAD CELL"},"content":{"rendered":"<h3>LOAD DISC II LOAD CELL<\/h3>\n<h3>Technical Specification<\/h3>\n<table class=\"tableGrid\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>Average Accuracy<\/td>\n<td>0.02%<\/td>\n<\/tr>\n<tr>\n<td>Excitation Voltage<\/td>\n<td>10 to 30 VDC<\/td>\n<\/tr>\n<tr>\n<td>Excitation Current<\/td>\n<td>4 mA<\/td>\n<\/tr>\n<tr>\n<td>Defection<\/td>\n<td>0.004<\/td>\n<\/tr>\n<tr>\n<td>Functional Integrity<\/td>\n<td>2x rated load in compression<\/td>\n<\/tr>\n<tr>\n<td>Structural Integrity<\/td>\n<td>4x rated load in compression<\/td>\n<\/tr>\n<tr>\n<td>Operating Temperature<\/td>\n<td>0\u00b0 to 100\u00b0 F (-18\u00b0 to 38\u00b0 C)<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>Installed Height: 2.7 in. (69 mm) \u2013 15k to 25k; 5.5 in. (140 mm) \u2013 35k to 100k<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<a href=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/08\/km-load-disc-ii-load-cell-specification-sheet.pdf\" class=\"pdfemb-viewer\" style=\"\" data-width=\"max\" data-height=\"max\" data-toolbar=\"both\" data-toolbar-fixed=\"on\">km-load-disc-ii-load-cell-specification-sheet<\/a>\n","protected":false},"excerpt":{"rendered":"<div class=\"sfContentBlock\">\n<div>\n<h3>Low profile, High Capacity<\/h3>\n<p>The LDII load cell has the lowest profile for its load ranges in the industry, and uses the proven KM semiconductor strain gauge technology to continuously measure the weight of material for in-process inventory and bulk storage vessels.<\/p>\n<\/div>\n<div>\n<ul class=\"bullets\">\n<li>Suitable for use with mixing and blending vessels, surge hoppers, and vessels with agitators<\/li>\n<li>Standard load ranges are from 150 to 100,000 pounds (68 to 45,360 kg) per vessel support<\/li>\n<li>Vessel tipping, walking or overturning while agitating is eliminated<\/li>\n<li>No external vessel hold-downs are necessary, even in<br \/>\nareas of high wind or seismic activity<\/li>\n<li>Only 0.004 inch at rated output minimizes piping &amp; plumbing influences for reliable results<\/li>\n<li>Incorporates NEMA 4 &amp; 4X in a stainless steel hermetically sealed package for protection in high pressure, caustic wash downs<\/li>\n<li>Cable runs up to 2000 feet<\/li>\n<\/ul>\n<\/div>\n<\/div>\n","protected":false},"featured_media":313085,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[6271],"product_cat":[3386],"product_tag":[6275],"class_list":{"0":"post-313083","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-kistler-morse","7":"product_cat-cylindrical-pancake","8":"product_tag-load-disc-ii-load-cell-en","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Kistler Morse LOAD DISC II LOAD CELL - CAS Scale Korea Co., Ltd.<\/title>\n<meta name=\"description\" content=\"Low profile, High Capacity The LDII load cell has the lowest profile for its load ranges in the industry, and uses the proven KM semiconductor strain gauge technology to continuously measure the weight of material for in-process inventory and bulk storage vessels.     Suitable for use with mixing and blending vessels, surge hoppers, and vessels with agitators  Standard load ranges are from 150 to 100,000 pounds (68 to 45,360 kg) per vessel support  Vessel tipping, walking or overturning while agitating is eliminated  No external vessel hold-downs are necessary, even in areas of high wind or seismic activity  Only 0.004 inch at rated output minimizes piping &amp; plumbing influences for reliable results  Incorporates NEMA 4 &amp; 4X in a stainless steel hermetically sealed package for protection in high pressure, caustic wash downs  Cable runs up to 2000 feet\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/casscale.net\/en\/products\/kistler-morse-load-disc-ii-load-cell\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Kistler Morse LOAD DISC II LOAD CELL\" \/>\n<meta property=\"og:description\" content=\"Low profile, High Capacity The LDII load cell has the lowest profile for its load ranges in the industry, and uses the proven KM semiconductor strain gauge technology to continuously measure the weight of material for in-process inventory and bulk storage vessels.     Suitable for use with mixing and blending vessels, surge hoppers, and vessels with agitators  Standard load ranges are from 150 to 100,000 pounds (68 to 45,360 kg) per vessel support  Vessel tipping, walking or overturning while agitating is eliminated  No external vessel hold-downs are necessary, even in areas of high wind or seismic activity  Only 0.004 inch at rated output minimizes piping &amp; plumbing influences for reliable results  Incorporates NEMA 4 &amp; 4X in a stainless steel hermetically sealed package for protection in high pressure, caustic wash downs  Cable runs up to 2000 feet\" \/>\n<meta property=\"og:url\" content=\"https:\/\/casscale.net\/en\/products\/kistler-morse-load-disc-ii-load-cell\/\" \/>\n<meta property=\"og:site_name\" content=\"CAS Scale Korea Co., Ltd.\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-05T01:46:11+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/casscale.net\/wp-content\/uploads\/2026\/08\/load-disc-ii-load-cell_L3.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"270\" \/>\n\t<meta property=\"og:image:height\" content=\"260\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/kistler-morse-load-disc-ii-load-cell\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/kistler-morse-load-disc-ii-load-cell\\\/\",\"name\":\"Kistler Morse LOAD DISC II LOAD CELL - CAS Scale Korea Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/kistler-morse-load-disc-ii-load-cell\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/kistler-morse-load-disc-ii-load-cell\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/load-disc-ii-load-cell_L3.jpg\",\"datePublished\":\"2026-08-05T01:43:42+00:00\",\"dateModified\":\"2026-08-05T01:46:11+00:00\",\"description\":\"Low profile, High Capacity The LDII load cell has the lowest profile for its load ranges in the industry, and uses the proven KM semiconductor strain gauge technology to continuously measure the weight of material for in-process inventory and bulk storage vessels. Suitable for use with mixing and blending vessels, surge hoppers, and vessels with agitators Standard load ranges are from 150 to 100,000 pounds (68 to 45,360 kg) per vessel support Vessel tipping, walking or overturning while agitating is eliminated No external vessel hold-downs are necessary, even in areas of high wind or seismic activity Only 0.004 inch at rated output minimizes piping &amp; plumbing influences for reliable results Incorporates NEMA 4 &amp; 4X in a stainless steel hermetically sealed package for protection in high pressure, caustic wash downs Cable runs up to 2000 feet\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/kistler-morse-load-disc-ii-load-cell\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/kistler-morse-load-disc-ii-load-cell\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/kistler-morse-load-disc-ii-load-cell\\\/#primaryimage\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/load-disc-ii-load-cell_L3.jpg\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/load-disc-ii-load-cell_L3.jpg\",\"width\":270,\"height\":260},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/casscale.net\\\/en\\\/products\\\/kistler-morse-load-disc-ii-load-cell\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/casscale.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/casscale.net\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Kistler Morse LOAD DISC II LOAD CELL\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#website\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"description\":\"A specialized company in weighing and measurement solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\"},\"alternateName\":\"Casscale\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/casscale.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#organization\",\"name\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"alternateName\":\"Casscale Korea\",\"url\":\"https:\\\/\\\/casscale.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"contentUrl\":\"https:\\\/\\\/casscale.net\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cropped-logo4.png\",\"width\":512,\"height\":512,\"caption\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\"},\"image\":{\"@id\":\"https:\\\/\\\/casscale.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.\",\"email\":\"sales@casscale.co.kr\",\"telephone\":\"02-3665-8158\",\"legalName\":\"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544\",\"foundingDate\":\"2003-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/casscale.net\\\/products\\\/\",\"ownershipFundingInfo\":\"https:\\\/\\\/casscale.net\\\/introduce\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Kistler Morse LOAD DISC II LOAD CELL - CAS Scale Korea Co., Ltd.","description":"Low profile, High Capacity The LDII load cell has the lowest profile for its load ranges in the industry, and uses the proven KM semiconductor strain gauge technology to continuously measure the weight of material for in-process inventory and bulk storage vessels.     Suitable for use with mixing and blending vessels, surge hoppers, and vessels with agitators  Standard load ranges are from 150 to 100,000 pounds (68 to 45,360 kg) per vessel support  Vessel tipping, walking or overturning while agitating is eliminated  No external vessel hold-downs are necessary, even in areas of high wind or seismic activity  Only 0.004 inch at rated output minimizes piping &amp; plumbing influences for reliable results  Incorporates NEMA 4 &amp; 4X in a stainless steel hermetically sealed package for protection in high pressure, caustic wash downs  Cable runs up to 2000 feet","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/casscale.net\/en\/products\/kistler-morse-load-disc-ii-load-cell\/","og_locale":"en_US","og_type":"article","og_title":"Kistler Morse LOAD DISC II LOAD CELL","og_description":"Low profile, High Capacity The LDII load cell has the lowest profile for its load ranges in the industry, and uses the proven KM semiconductor strain gauge technology to continuously measure the weight of material for in-process inventory and bulk storage vessels.     Suitable for use with mixing and blending vessels, surge hoppers, and vessels with agitators  Standard load ranges are from 150 to 100,000 pounds (68 to 45,360 kg) per vessel support  Vessel tipping, walking or overturning while agitating is eliminated  No external vessel hold-downs are necessary, even in areas of high wind or seismic activity  Only 0.004 inch at rated output minimizes piping &amp; plumbing influences for reliable results  Incorporates NEMA 4 &amp; 4X in a stainless steel hermetically sealed package for protection in high pressure, caustic wash downs  Cable runs up to 2000 feet","og_url":"https:\/\/casscale.net\/en\/products\/kistler-morse-load-disc-ii-load-cell\/","og_site_name":"CAS Scale Korea Co., Ltd.","article_modified_time":"2026-08-05T01:46:11+00:00","og_image":[{"width":270,"height":260,"url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/08\/load-disc-ii-load-cell_L3.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/casscale.net\/en\/products\/kistler-morse-load-disc-ii-load-cell\/","url":"https:\/\/casscale.net\/en\/products\/kistler-morse-load-disc-ii-load-cell\/","name":"Kistler Morse LOAD DISC II LOAD CELL - CAS Scale Korea Co., Ltd.","isPartOf":{"@id":"https:\/\/casscale.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/casscale.net\/en\/products\/kistler-morse-load-disc-ii-load-cell\/#primaryimage"},"image":{"@id":"https:\/\/casscale.net\/en\/products\/kistler-morse-load-disc-ii-load-cell\/#primaryimage"},"thumbnailUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/08\/load-disc-ii-load-cell_L3.jpg","datePublished":"2026-08-05T01:43:42+00:00","dateModified":"2026-08-05T01:46:11+00:00","description":"Low profile, High Capacity The LDII load cell has the lowest profile for its load ranges in the industry, and uses the proven KM semiconductor strain gauge technology to continuously measure the weight of material for in-process inventory and bulk storage vessels. Suitable for use with mixing and blending vessels, surge hoppers, and vessels with agitators Standard load ranges are from 150 to 100,000 pounds (68 to 45,360 kg) per vessel support Vessel tipping, walking or overturning while agitating is eliminated No external vessel hold-downs are necessary, even in areas of high wind or seismic activity Only 0.004 inch at rated output minimizes piping &amp; plumbing influences for reliable results Incorporates NEMA 4 &amp; 4X in a stainless steel hermetically sealed package for protection in high pressure, caustic wash downs Cable runs up to 2000 feet","breadcrumb":{"@id":"https:\/\/casscale.net\/en\/products\/kistler-morse-load-disc-ii-load-cell\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/casscale.net\/en\/products\/kistler-morse-load-disc-ii-load-cell\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/en\/products\/kistler-morse-load-disc-ii-load-cell\/#primaryimage","url":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/08\/load-disc-ii-load-cell_L3.jpg","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2026\/08\/load-disc-ii-load-cell_L3.jpg","width":270,"height":260},{"@type":"BreadcrumbList","@id":"https:\/\/casscale.net\/en\/products\/kistler-morse-load-disc-ii-load-cell\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/casscale.net\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/casscale.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"Kistler Morse LOAD DISC II LOAD CELL"}]},{"@type":"WebSite","@id":"https:\/\/casscale.net\/#website","url":"https:\/\/casscale.net\/","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","description":"A specialized company in weighing and measurement solutions","publisher":{"@id":"https:\/\/casscale.net\/#organization"},"alternateName":"Casscale","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/casscale.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/casscale.net\/#organization","name":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","alternateName":"Casscale Korea","url":"https:\/\/casscale.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/","url":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","contentUrl":"https:\/\/casscale.net\/wp-content\/uploads\/2025\/07\/cropped-logo4.png","width":512,"height":512,"caption":"\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544"},"image":{"@id":"https:\/\/casscale.net\/#\/schema\/logo\/image\/"},"description":"\uce74\uc2a4\uc2a4\ucf00\uc77c\uc740 \uc0b0\uc5c5\uc6a9 \uacc4\ub7c9 \ubc0f \uacc4\uce21 \uc194\ub8e8\uc158\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uae30\uc5c5\uc73c\ub85c, \ub85c\ub4dc\uc140, \uc0b0\uc5c5\uc6a9 \uc800\uc6b8, \uc815\ubc00 \uce21\uc815 \uc2dc\uc2a4\ud15c \ub4f1\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc815\ud655\uc131\uacfc \ub0b4\uad6c\uc131\uc744 \uae30\ubc18\uc73c\ub85c \uc0b0\uc5c5 \ud604\uc7a5\uc5d0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc81c\ud488\uacfc \uc194\ub8e8\uc158\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.","email":"sales@casscale.co.kr","telephone":"02-3665-8158","legalName":"(\uc8fc)\uce74\uc2a4\uc2a4\ucf00\uc77c\ucf54\ub9ac\uc544","foundingDate":"2003-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/casscale.net\/products\/","ownershipFundingInfo":"https:\/\/casscale.net\/introduce\/"}]}},"_links":{"self":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product\/313083","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/comments?post=313083"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media\/313085"}],"wp:attachment":[{"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/media?parent=313083"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_brand?post=313083"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_cat?post=313083"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.net\/en\/wp-json\/wp\/v2\/product_tag?post=313083"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}